B.D.I. The B.D.I. (Burst Disc Indicator) Alarm System is designed for use with Continental Disc



Similar documents
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Electronic Flow Switches

Continental Disc Corporation Rupture Disc Selection Guide

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Sanitary Type Electronic Flow Switches

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Ammonia Detection System Codes and Design Specifications

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

OIL & GAS EXPERTS RIGHT PRESSURE RELIEF SOLUTION WE ARE THE & PRESSURE ACTIVATION BRAND PRODUCTS

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Fire Alarm System Accessories

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

In-Line Electronic Flow Switches

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Medical Air Systems: Scroll

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

SITRANS F flowmeters SITRANS F M

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

WD-AMX Water Detection Controllers

Technical Data. Dimensions

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Cable Plug acc. to DIN EN , Form A

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

In-Line Electronic Flow Switches

DC400 Dispensing Cutoff System

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

AlarmLine Addressable Linear Heat Detector

Advantium 2 Plus Alarm

Mobrey Hydrastep and Hydratect

Reliability Accuracy Performance

3500/22M Transient Data Interface

Fire & Security DETECTORS

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Inductive sensor NI10-M18-Y1X-H1141

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

DUCT SMOKE DETECTOR D4120

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Triple Waveband Infra-Red Flame Detection

for ALL your Rupture Disk needs...

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Plastic tube flowmeters Series PT/PS

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Model 3051 Pressure Transmitter with HART Protocol

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Fire Pump Controllers Remote Alarm Panels

Water Leak Detection System

PBX Series Quick Fit Connector Bimetallic Steam Traps

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

B-Series Switches Pressure, Differential Pressure & Hydraulic

CO2 Alarm. Operation. Application

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Technical Data. Dimensions

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

PRODUCT PROFILE FEATURES

How To Make A Pressure Relief Valve

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Solenoid Valve Island Type 3965

Scraper Passage Indicator. Electrical Indicator. Features

Micro Motion 3098 Gas Specific Gravity Meter

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

3/2-way Solenoid Valve, direct-acting, NC or NO

AUTOMATIC CHANGEOVER MANIFOLD Series 915

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Inductive Proximity Sensors

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Instructions for Safe Use

Controller Automation, Model II+

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

MS41-22Ex0-R/24VDC MS41-22Ex0-R/115VAC MS41-22Ex0-R/230VAC

Flow switches Series AD/VH

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Cooling Channel Optimization

Heating Cable. Construction

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Worcester DS/DM Series UltraSwitch Switch box

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

ALARMLINE ANALOGUE Linear Heat Detection System

Intrinsically Safe Barrier Relays NY2 and 8501TO

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

CQM1-SF200/CS1W-SF200

Electronic, Digital and Mechanical Vibration Switches

BERMAD Fire Protection

Thermatel Model TA1 Mass Flow Transmitter

Manual for Fire Suppression & Methane Detection System

NGC-30-CR -CRM -CRMS -CTM -CVM

Element D Services Plumbing

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Terminal Box. Specifications TNCN

Transcription:

B.D.I. BURST DISC INDICATOR The B.D.I. (Burst Disc Indicator) Alarm System is designed for use with Continental Disc rupture discs. The B.D.I. Alarm System signals the system operator when a rupture disc has burst to relieve an overpressure or vacuum condition. WHEN NOTIFICATION OF PRESSURE RELIEF IS ESSENTIAL Continental Disc Rupture Discs with the B.D.I. Alarm System The heart of the system is the B.D.I. Alarm Strip. Upon disc rupture, the B.D.I. Alarm Strip is severed, disrupting the flow of electric current through the strip. The change in the electric circuit status can be monitored in a control room, or an optional alarm monitor is available from Continental Disc to warn of a rupture disc burst and/or activate appropriate equipment. The B.D.I. Alarm System should be specified: When warning of pressure relief is essential for plant safety When immediate notice is needed of relief of an overpressure or vacuum condition to indicate process malfunction When indication is vital that a rupture disc has burst and toxic substances are venting When a signal is required to initiate an automatic function, process change or shut down procedure When loss or contamination of product will occur if a rupture disc is not replaced immediately When monitoring of rupture discs is important in hard-to-reach locations Proven Design The B.D.I. Alarm Strip is designed to break when its correspond ing rupture disc bursts. Continental Disc s design has been proven through years of testing, both in the field and in our ASME accepted flow testing laboratory. This testing has proved the reliability of the alarm strip when used with Continental Disc Corporation rupture discs. The B.D.I. Alarm Strip does not affect the life or performance of the rupture disc. The B.D.I. Alarm Strip is carefully designed and manufactured with the following features in mind: Resistant to chemical attack and corrosion Usable over a wide range of temperatures Easily replaceable upon disc rupture Compatible with standard design Continental Disc Corporation rupture discs B.D.I. with shielded cable ATEX Directive Compliant The B.D.I. Alarm Strip and the MTB 700 Alarm Monitor have been certified for use in potentially explosive atmospheres according to the requirements of the European Union, ATEX Directive 94/9/EC. ATEX type approval and quality assurance notification certificates are available on our website at www.contdisc.com.

B.D.I. ALARM SYSTEM DATASHEET // PAGE 2 B.D.I. Alarm System // Operating Schematic B.D.I. Alarm Strip Normal Closed State Open State Connector Lead Wire B.D.I. ALARM MONITOR B.D.I. ALARM MONITOR Optional Switching Connection Annunciator or Control Panel Annunciator or Control Panel Visual Warning Audio Warning TYPICAL APPLICATIONS Rupture disc applications which can incorporate a B.D.I. Alarm System are limitless and found across a broad spectrum of industries and processes, and where an instant notification of an overpressure or vacuum event is required Relief Valves Isolating relief valves with a rupture disc protects internal valve parts from corrosive media. The B.D.I. Alarm System signals when a disc rupture relieves an overpressure condition, enabling the operator to correct the process and restore protection to the relief valve. Installing a rupture disc with a B.D.I. Alarm Strip on the outlet side of a relief valve notifies the operator when a valve has relieved. This is an especially important application when handling toxic or corrosive substances. Processing Vessels Rupture discs with the B.D.I. Alarm System are used on processing tanks and vessels requiring protection from overpressure or vacuum conditions. The system warns when a disc ruptures. Chemical Reactors When processing temperatures and pressures are critical, the B.D.I. Alarm System gives immediate warning when service is interrupted due to relief of an overpressure condition. Tank Transports The B.D.I. Alarm System signals immediately when a rupture disc has burst, thereby releasing product to the atmosphere. Pipeline Pumping Stations Rupture discs relieve pressure buildup in pumping stations caused by blocked pipelines. The system signals as relief occurs and can trigger shutdown of pumping systems. Fermentation Vessels Products requiring gaseous blankets to prevent spoilage or product contamination must be protected from the atmosphere. Immediate warning of disc rupture permits quick corrective action, reducing loss of product and expensive gases. Storage/Silo Tanks Storage tanks which damage easily from overpressure or vacuum conditions are protected with the CAL-VAC Rupture Disc or POS-A-SET Rupture Disc. Often these discs are located in hard-to-reach areas. The B.D.I. Alarm System warns immediately when the rupture disc bursts. Distillation Equipment Distilled products must be free from contamination. Operator warning is vital when a product batch is contaminated from the intake of an outside atmosphere during vacuum relief. The B.D.I. Alarm System provides the needed warning.

B.D.I. ALARM SYSTEM DATASHEET // PAGE 3 THE HEART OF THE SYSTEM...THE B.D.I. ALARM STRIP The B.D.I. Alarm Strip is designed to break when its correspond ing rupture disc bursts. This creates an open circuit which is detected by the B.D.I. Alarm Monitor, or other suitable monitoring device. Design Specifications Maximum current: 50 milliamps Maximum voltage: 24 VDC RMS Operating temperature range: -40 F to +400 F (-40 C to +204 C) Minimum relieving pressures: MINIMUM PRESSURE FOR UNIVERSAL B.D.I. NOMINAL SIZE PRESSURE in mm psig barg 1" 25 15 1,03 1½" 40 10 0,69 2" 50 4 0,28 3" 80 2.5 0,17 4" 100 2.5 0,17 6" - 36" 150-900 1 0,07 The UNIVERSAL Low Pressure B.D.I. is available for sizes 1" - 4" for pressures down to 1 psig (0,07 barg) Components The B.D.I. Alarm Strip is composed of copper conductors adhered to a thin strip of KAPTON film. Tantalum conductors are available for applications that require corrosion resistance. The conductors pass through the rupture disc seating area for Integral B.D.I. designs or flange gasket facing for Universal B.D.I. designs, terminating with your choice of a molded plug or bare leads. Integral B.D.I. on Rupture Disc with Sanitary Design Holder The B.D.I. Alarm Strip is manufactured as either an Integral B.D.I. or a Universal B.D.I. design, dependent upon the rupture disc product it is to mate with (See Table 1 on next page). The Universal B.D.I. design is compatible with rupture disc/ holder assemblies designed to install between bolted flange standards including ASME, DIN, JIS, see Table 2 for available flange classes. Custom designs are also available, contact the factory for details. Standard gaskets are asbestos free fiber-bound material or an optional GYLON 3500 silica filled PTFE material. Insert Design Assembly

B.D.I. ALARM SYSTEM DATA SHEET // PAGE 4 Table 1 Table 2 RUPTURE DISC / B.D.I. ALARM STRIP TYPE SELECTION INTEGRAL B.D.I. SANITRX HPX HPX SANITRX HPX II UNIVERSAL B.D.I. HPX -Ta CAL-VAC LOTRX POS-A -SET RCS ENVIRO SEAL MICRO X Vent Panel GRAFSERT SEALSERT CDC, CDCV for (SF) PL, PLV for (SF) Composite Standard (all others not listed) BOLTING CLASSES AVAILABLE FOR UNIVERSAL B.D.I. ALARMS SIZE ASME DIN JIS 1" - 1½" 2" - 3" 150#, 300#/600# 150#, 300#/600# 4", 6" 150#, 300# 8" - 12" 150#, 300# PN 10/40 2/5K, 10/20K, 30/40K PN 10/40 2/5K, 10K, 16/20K, 30/40K PN 10/16, PN 25/40 PN 10, PN 16, PN 25, PN 40 2/5K, 10K, 16/20K, 30K, 40K 2/5K, 10K, 16/20K, 30K, 40K 14", 16" 150# PN 10, PN 16 2/5K, 10K, 16/20K, 30K, 40K 18" 150# 5K, 10K, 16/20K 20", 24" 150# PN 10, PN 16 5K, 10K, 16/20K 28" 150# PN 10, PN 16 5K, 10K, 16K, 20K 30" 150# 5K, 10K, 16K, 20K 32", 36" 150# PN 10, PN 16 5K, 10K, 16K, 20K Components continued... The Sanitary (IS) B.D.I. design is compatible with rupture disc/ holder assemblies designed to be install between industry standard ferrules. Standard gaskets are Platinum or Peroxide Cured Silicone, Black and White VITON, Black and White EPDM, PTFE and steel reinforced PTFE materials. Additional information regarding gasket materials and temperature limits for the Sanitary (IS) B.D.I. design can be found in the GASKET MATERIALS & TEMPERATURES table in the SANITARY ACCESSORIES section of the HPX PRODUCT FAMILY brochure. MINIMUM PRESSURE FOR SANITARY (IS) B.D.I. NOMINAL SIZE PRESSURE in mm psig barg 1½" 40 10 0,69 2" 50 4 0,28 3" 80 2.5 0,17 4" 100 2.5 0,17 Linking the B.D.I. Alarm Strip to the monitoring system is the B.D.I. Lead Wire Assembly. A two-pin bullet plug protects the terminals at the connecting point against moisture. It is abrasion resistant, flexible and highly weather-resistant. An alternate bare leads end of shielded cable is also available in 6 ft (2m), 10 ft (3m) and 20 ft (6m) lengths. Use the B.D.I. Lead Wire Assembly to connect the B.D.I. Alarm Strip with a Standard Plug B.D.I. Connection to the B.D.I. Alarm Monitor. The B.D.I. Lead Wire Assembly is available in 6, 10, 20, 50, 75, 100, 200 and 300 foot lengths with a Standard Plug B.D.I. Connector and a Lead Wire Strain Relief Device on one end and bare leads on the other. End User Suggestions When there is a distance of 15 feet or more of unsupported cable between the B.D.I. Alarm Strip and the B.D.I. Alarm Monitor, a junction box is recommended. This box protects the alarm strip from the weight of the long cable, as well as protecting the cable connection from environmental elements. Shielded cable should be used for cable runs between a junction box and the B.D.I. Alarm Monitor to prevent triggering of a false alarm.

B.D.I. ALARM SYSTEM DATASHEET // PAGE 5 HPX RUPTURE DISC ASSEMBLY WITH UNIVERSAL B.D.I. B.D.I. ALARM STRIP GASKET STRAIN BRACE SHIELDED CABLE BARE LEADS CONNECTION IDENTIFICATION TAG B.D.I. LEAD WIRE ASSEMBLY AND CAL-VAC RUPTURE DISC WITH INTEGRAL B.D.I. IDENTIFICATION TAG B.D.I. ALARM STRIP LEAD WIRE STRAIN RELIEF DEVICE STANDARD PLUG B.D.I. CONNECTION

B.D.I. ALARM SYSTEM DATA SHEET // PAGE 6 B.D.I. ALARM MONITOR FUNCTIONS, FEATURES & OPTIONS The B.D.I. Alarm System uses a normally closed electrical circuit. A continuous signal flows between the B.D.I. Alarm Strip and the Alarm Monitor under normal conditions. Once the rupture disc bursts, the Alarm Strip breaks, opening the electrical circuit. B.D.I. Alarm Monitors contain replaceable modules with individual channel relays. Each channel relay connects to one alarm strip. As the rupture disc and B.D.I. Alarm Strip break, a specific relay is actuated, sending a signal to the control panel. Control panels, annunciators, light panels or other signalling devices can be used to warn of a ruptured disc. The B.D.I. Alarm System is versatile to adapt to a variety of warning devices. Individual relay circuitry allows the user to monitor several B.D.I. Alarm Strips at once. Pumps, valves, and other systems may also be activated to respond to an overpressure or vacuum situation by the break of a specific B.D.I. Alarm Strip. Definitions As used in the MTB-700, BB-100A and BB-400A Alarm Monitor descriptions: INTRINSICALLY SAFE is defined as: Apparatus, including wiring, in which any spark or thermal effect produced either normally or in specified fault conditions...is incapable under test conditions of causing ignition of a specified mixture of flammable or combustible material in air. MTB-700 ALARM MONITOR WITH HPX ASSEMBLY AND UNIVERSAL B.D.I. The MTB-700 Alarm Monitor incorporates intrinsically safe galvanically isolated barriers, approved for use in many countries worldwide. An MTL5018AC barrier is utilized on the MTB-700 Alarm Monitor with a 120/240 VAC input power option. An MTL5018 barrier is utilized on the MTB-700 Alarm Monitor with the 24 VDC input power option. Upon disc rupture, these barriers activate signals and/or output relays to warn operators and actuate pumps, valves or other equipment connected to the system.

B.D.I. ALARM SYSTEM DATA SHEET // PAGE 7 Model Overview MODELS AVAILABLE MTB-700 BB-100A BB-400A Dry contacts for remote alarms YES YES YES Output relay type DPDT Form C SPDT Form C SPDT Form C Relay max current 5 A @ 240 VAC Resistive 2 A @ 120 VAC Resistive 2 A @ 120 VAC Resistive 5 A @ 24 VDC Resistive 1 A @ 120 VAC Inductive 1 A @ 120 VAC Inductive 1/8 HP @ 120/240 VAC, 2 A @ 24 VDC Inductive 2 A @ 24 VDC Inductive 7 A maximum carry current Intrinsically safe field circuit YES YES YES Barrier type galvanically isolated zener diode zener diode Enclosure rating NEMA 4, 4X, 12, 13 NONE NONE Operating temperature range -4 F to +113ºF (-20ºC to +45ºC) -40ºF to +104ºF (-40ºC to +40ºC) -40ºF to +104ºF (-40ºC to +40ºC) Reset mode (latching, non-latching) latching only either available either available Output current to BDI Strip 7 VDC @ 22 MA 6 VDC @ 0.1 MA 6 VDC @ 0.1 MA Remote master test contacts YES NO NO Remote master reset contacts YES YES YES Barrier Certifications FM, ATEX, CSA, IECEx None None Model Options Monitor Model # of Discreet Channels Audio/Visual Alarm Yes 2 No MTB-700 Yes 4 No BB-100A 2 No BB-400A 8 No Input Power Part Number 24 VDC +/- 2 V M2A0000V024 120 VAC 50/60 Hz M2A0000V120 240 VAC 50/60 Hz M2A0000V240 24 VDC +/- 2 V M2S0000V024 120 VAC 50/60 Hz M2S0000V120 240 VAC 50/60 Hz M2S0000V240 24 VDC +/- 2 V M4A0000V024 120 VAC 50/60 Hz M4A0000V120 240 VAC 50/60 Hz M4A0000V240 24 VDC +/- 2 V M4S0000V024 120 VAC 50/60 Hz M4S0000V120 240 VAC 50/60 Hz M4S0000V240 115 VAC 50/60 Hz, 230 VAC 50/60 Hz or 12 VDC +/- 2 V 520000300 115 VAC 50/60 Hz, 230 VAC 50/60 Hz or 12 VDC +/- 2 V 520000400

CERTIFICATIONS Available When Specified B.D.I. ALARM SYSTEM DATA SHEET // PAGE 8 UNIVERSAL B.D.I. WITH STANDARD PLUG CONNECTION ATEX Directive Compliant INTEGRAL B.D.I. WITH SHIELDED CABLE AND BARE LEADS INTEGRAL B.D.I. WITH STANDARD PLUG CONNECTION NOTE: Product parameters are based on United States customary units. Values in metric units are provided for reference only. FOR MORE INFORMATION ON OUR OTHER BURST DISC INDICATION PRODUCTS, PLEASE SEE THE BDI-FLX BURST DISC SENSOR SYSTEM DATASHEET. VITON is a registered trademark of E.I. du Pont de Nemours and Company used under license GYLON is a registered trademark of Garlock Sealing Technologies // KAPTON is a registered trademark of E.I. Du Pont de Nemours and Company HEADQUARTERS // 3160 W. Heartland Drive Liberty, MO 64068 USA Ph (816) 792 1500 Fax (816) 792 2277 sales@contdisc.com contdisc.com THE NETHERLANDS Energieweg 20 2382 NJ Zoeterwoude-Rijndijk The Netherlands Ph +(31) 71 5412221 Fax +(31) 71 5414361 cdcnl@contdisc.com CHINA Room 1312, Tower B, COFCO Plaza No. 8 JianGuoMenNei Avenue Beijing (10005), P.R. China Ph +(86) 10 522 4885 Fax +(86) 10 6522 2885 cdcchina@contdisc.com INDIA 423/P/11, Mahagujarat Industrial Estate, Moraiya, Sarkhej-Bavla Road, Ahmedabad (GJ) 382213 INDIA Ph +(91) 2717 619 333 Fax +(91) 2717 619 345 gcmpl@contdisc.com Continental Disc Corporation reserves the right to alter the information in this publication without notice. // 2014 Continental Disc Corporation Reproduction without written permission is prohibited. PRINTED IN U.S.A. TCH1284DS TEF TMR // 1114