LDCDP EPC50ACU.SR6. L force Controls. Ä.SR6ä. Software Manual. Industrial PC. ACU UPS software for Industrial PCs



Similar documents
LDCDP GdW. L force Controls. Ä.GdWä. Software Manual. Industrial PC. WindowsR CE Thin Client. Operating system

AC500. Software Description. Scalable PLC for Individual Automation. Installation of the AC500 Control Builder PS501

AIM SOFTWARE AND USB DRIVER INSTALLATION PROCEDURE

Procedure for updating Firmware of EZ4 W or ICC50 W

Changing Your Cameleon Server IP

Quick Start to Evaluating. HP t5630w, HP t5730w, HP gt7720

1 Minimum system requirements

HP ThinShell. Administrator Guide

Guide to Installing BBL Crystal MIND on Windows 7

Image Backup and Recovery Procedures

Firmware & Software update procedures Amicroe TouchTAB IV.

User Guide Win7Zilla

Back-up Server DOC-OEMSPP-S/2014-BUS-EN-10/12/13

Installing PowerLink on Windows 7 64-bit

WPA-LON Series WPA-LON-1. Application. Model Chart WPA-LON-2 WPA-LON-3. Adapter Card Software

RAID Option Installation

How to install and use the File Sharing Outlook Plugin

Backup Server DOC-OEMSPP-S/6-BUS-EN

L-force Controls SHPBCKNREST Ezf. Software Manual. PC-based Automation. Backup & Restore

STEP BY STEP IIS, DotNET and SQL-Server Installation for an ARAS Innovator9x Test System

Virtual CD v10. Network Management Server Manual. H+H Software GmbH

Centurion PLUS CPC4 Download Guide

Virtual Office Remote Installation Guide

DUKANE Intelligent Assembly Solutions

Allworx OfficeSafe Operations Guide Release 6.0

Quick start to evaluating HP Windows Embedded Standard 2009 Thin Clients. HP t5630w, HP t5730w, HP t5740, HP gt7720

XF Extracellular Flux Analyzer. Installation and Troubleshooting Guide

SA-9600 Surface Area Software Manual

How To Upgrade Your Microsoft SQL Server for Accounting CS Version

Transmitter Interface Program

FrenzelSoft Stock Ticker

How To Install And Run Cesview Iii (For New Users)

SQL Server 2008 R2 Express Edition Installation Guide

Moxa Device Manager 2.0 User s Guide

Accounting Manager. User Guide A31003-P1030-U

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

Dell OptiPlex XE Watchdog Timer

Automation License Manager

Installation and Configuration Guide

...2. Standard Installation...4. Example Installation Scenarios...5. Network Installation...8. Advanced Settings Product Requirements

Human Resources Installation Guide

Shearwater Research Dive Computer Software Manual

Chapter 1 Downloading Images to Your Computer (Windows)

Scan to PC Desktop: Image Retriever 5.2 for Xerox WorkCentre C2424

Iridium Extreme TM Satellite Phone. Data Services Manual

MDM Mass Configuration Tool User s Manual

Installing the USB driver for Firmware 7 or later For use with E-blocks programmer boards and PICmicro Development boards.

Installation Guide - Client. Rev 1.5.0

Installing the Microsoft Network Driver Interface

VirtualXP Users Guide

Colorfly Tablet Upgrade Guide

Image Backup and Recovery Procedures

Image Assistant. User Guide. Image Assistant. Laplink Software, Inc. User Guide. The ONLY Way to Restore an Old Image to a New PC!

Division of Administration (DOA) Desktop Support

Global VPN Client Getting Started Guide

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Getting Started. rp5800, rp5700 and rp3000 Models

HP External Hard Disk Drive Backup Solution by Seagate User Guide. November 2004 (First Edition) Part Number

Infinity C Reference Guide

Note: The USTInstaller does check for and installs *if needed* Adobe Reader and MS.NET Framework. Topics covered in this Manual:

User Guide. Windows 8 Upgrade Assistant. Laplink Software, Inc. MN-PCM-UpgdAssist-EN-08 (REV. 10/2012)

Verizon Remote Access User Guide

SOFTWARE INSTALLATION INSTRUCTIONS

N600 WiFi USB Adapter

VERITAS Backup Exec TM 10.0 for Windows Servers

Volume AIG. AGKSOFT ActiveSync Inventory Guide. ActiveSync Inventory Guide

Moxa Device Manager 2.3 User s Manual

Administrator s Guide

Windows XP.. ELITE Firmware Update procedures.. v1.41

HP MediaSmart Server Software Upgrade from v.2 to v.3

ServerView Integration Pack for Microsoft SCCM

The following pages will help you to solve issues linked to the installation and first use of the Wintech Manager software and Wintech USB computer.

WINDOWS PROCESSES AND SERVICES

Manuals for This Product

Nortel Networks Call Center Reporting Set Up and Operation Guide

SQL EXPRESS INSTALLATION...

Use Remote Desktop capabilities to Access your Work PC from home over VPN

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

Monitor Wall 4.0. Installation and Operating Manual

Qbox User Manual. Version 7.0

IX Support Tool Setting Manual

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

USB DRIVER INSTALLATION GUIDE

Installation Instructions Release Version 15.0 January 30 th, 2011

Diamond II v2.3 Service Pack 4 Installation Manual

Windows XP Home Edition / Windows XP Professional

Pro-Watch Software Suite Installation Guide Honeywell Release 3.81

Version 2.10 Installation and Configuration Guide

For Windows XP 64 bit

CashFlow Programming Module CPM

TM Online Storage: StorageSync

USB DRIVER INSTALLATION GUIDE

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples

TestManager Administration Guide

WhatsUp Gold v16.1 Installation and Configuration Guide

User Installation Guide

User Manual. Thermo Scientific Orion

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

User s Guide for version 5 Page

DeviceNet Communication Card

Transcription:

LDCDP EPC50ACU.SR6 L force Controls Ä.SR6ä Software Manual Industrial PC ACU UPS software for Industrial PCs

Please read these instructions before you start working! Follow the enclosed safety instructions.

Validity information These instructions are valid for ƒ ACU UPS software for Lenze Industrial PCs Trademark Windows XP, Windows XP Embedded and Windows Embedded Standard 2009 are registered trademarks or trademarks of Microsoft Corporation in the USA and/or other countries. Any additional trade names given in this documentation are trademarks of their corresponding owners. Document history Material number Version Description 13218873 1.0 11/2007 TD29 First edition 13303164 2.0 08/2009 TD29 Revision 13348913 3.0 08/2010 TD29 Extension by the description of software versions V3.x and V4.x 13411916 4.0 06/2012 TD29 Revision of ACU control register.sr6 5.0 12/2015 TD09 Extension by the description of software version V5.x 0Fig. 0Tab. 0 Tip! Information and auxiliary devices related to the Lenze products can be found in the download area at http://www.lenze.com 3

i Contents 1 Software Description...................................................... 5 1.1 Operating mode...................................................... 5 1.2 System Requirements................................................. 5 1.3 Messages........................................................... 6 1.3.1 Message in case of a voltage failure............................. 6 1.3.2 Message after a change in ACU UPS state......................... 6 2 Software Operation........................................................ 7 2.1 Start and Close Software.............................................. 7 2.2 Open User Interface.................................................. 9 2.3 User Interface Dialogs................................................ 10 2.3.1 Registry "ACU State" Show UPS State........................... 10 2.3.2 Registry "ACU Control" Configure UPS.......................... 12 2.3.3 Registry "Time Set" Time Before Shutdown...................... 14 2.3.4 Registry "Application" Start External Programs................... 15 2.3.5 Registry "Shutdown" Force Shutdown.......................... 15 2.3.6 Registry "LogFile" View Program Messages...................... 16 3 Software Installation....................................................... 17 4

Software description Operating mode 1 1 Software Description The industrial PC option "ACU UPS Control Unit" in combination with a battery/capacitor pack extends the industrial PC (IPC) by one UPS function.the ACU UPS software controls the behaviour of the IPC in this process as soon as the hardware identifies a supply voltage failure. The ACU UPS control unit is a factory set pre equipment if you chose this option when placing your purchase order. However, it can also be upgraded later on by Lenze service personnel. If you purchased the preinstalled operating system on a storage medium at Lenze, the ACU UPS software is already installed and configured according to your hardware. Alternatively, you can find the software on the driver CD for your IPC. Then, install the software as described in the chapter "Software Installation". ( 17 1.1 Operating mode During the boot phase of the operating system, the ACU UPS is in a permanent buffer operation which means that it already provides protection against data loss in the boot phase, even before the ACU software has started. The ACU software starts automatically after the operating system has been booted and monitorsthe voltage supply from the background until it is closed along with the operating system. 1.2 System Requirements Note! Software versions Vx.x must only be used in conjunction with specific devices and are incompatible. ACU UPS version Device Operating system V2.x IPC CPC 2700, EL 870 9700 or CS 5700 9700 with ACU UPS control Windows XP or Windows XP Embedded unit V3.x L force Controller 3241 C Windows XP or Windows Embedded Standard 2009 V4.x V5.x IPC CPC 2800, EL 1800 9800 or CS 5800 9800 with ACU USV Control Unit IPC CPC 2800, EL 1800 9800 oder CS 5800 9800 mit ACU USV Control Unit Windows XP or Windows Embedded Standard 2009 Windows Embedded Standard 7 P 64bit 5

1 Software description Messages Message in case of a voltage failure 1.3 Messages 1.3.1 Message in case of a voltage failure In the case of a voltage failure, the ACU UPS takes charge of the IPC supply. The remaining time to the IPC shutdown is displayed on the desktop. ( 14). Fig. 1 1 Desktop message in the event of a voltage failure EPC50ACU 003 1.3.2 Message after a change in ACU UPS state Changes in ACU UPS state are indicated by a change in colour of the ACU symbol on the Windows task bar. Fig. 1 2 Windows task bar with ACU UPS symbol Legend: Green: Battery/capacitor pack loaded and active Yellow: Battery/capacitor pack is being loaded Red: Indicates one or more of the following faults: ACU UPS is buffering the system Short circuit in the battery/capacitor pack Battery/capacitor pack is not connected Battery/capacitor pack is damaged Non defined battery/capacitor packstatus Charging connection of the ACU UPS is defective EPC50ACU 001 6

Software operation Start and Close Software 2 2 Software Operation 2.1 Start and Close Software Start After the IPC has been booted, the software starts automatically and then runs in the background. A symbol pops up in the information bar. Fig. 2 1 Windows task bar with ACU UPS symbol EPC50ACU 001 Note! If an L force Controller is delivered with ACU UPS but without a battery pack, the ACU UPS software is installed but UPS support is deactivated. In this case, there will be no ACU symbol in the information bar of the Windows task bar. In the "ACU Control" registry, UPS support can be( 12)activated and deactivated. Double click the ACU symbol in the control panel to start the software manually. Fig. 2 2 Control panel with opened ACU software window (in our example: ACU UPS V3.x) EPC50ACU 011 7

2 Software operation Start and Close Software Close Usually, the software is automatically closed by Windows. If you want to close the software manually, right click the ACU symbol in the information bar of the Windows task bar and select Exit from the context menu. Fig. 2 3 Windows task bar with opened context menu EPC50ACU 002 ACU UPS V2.x: UPS functionality is switched off until it is switched on again via the context menu. ACU UPS V3.x/V4.x/V5.x: UPS functionality is switched off until the next system start up. 8

Software operation Open User Interface 2 2.2 Open User Interface Note! For configuring the ACU software, administrator rights are required. Otherwise, only actual states can be displayed. ƒ If you want to View ACU UPS Configuration, double click the ACU symbol in the information bar of the Windows task bar. The ACU software dialog is displayed. The registries of this dialog show the ACU UPS software settings. Various settings which affect software only can be made (e.g. the period of time from identifying a voltage failure to the shutdown of the IPC). Settings affecting the ACU UPS control unit hardware cannot be made. Fig. 2 4 ƒ Example: ACU software dialog ACU UPS V2.x EPC50ACU 005 If you want to Configure the ACU UPS Control Unit, double click on the ACU symbol in the Windows control panel. The ACU software dialog is also displayed. Unlike the process described above, the ACU control registry is displayed as well which helps you configure the behaviour of the ACU UPS control unit in the case of a voltage failure. Fig. 2 5 Example: ACU software dialog ACU UPS V2.x EPC50ACU 004 Information on the registries of the user interface of the various ACU UPS versions is provided in the following chapter. 9

2 Software operation User Interface Dialogs Registry "ACU State" Show UPS State 2.3 User Interface Dialogs 2.3.1 Registry "ACU State" Show UPS State ACU USV V2.x: Type Hardware Type Power OK/Fail Input Voltage State; OK or Failure UPS On/Off On: UPS functionality activated Buffer Time [s] 0.00... 64.00 s Period of time to wait until a voltage failure is reported by the ACU UPS control unit. Thus, voltage fluctuations are filtered out. Delay Time [s] 0... 240 s; infinite Maximum period of time the industrial PC can be fed by the battery/capacitor pack, depending on the hardware. ACU State Current ACU State Display Firmware Version Displays the current ACU firmware version Note! A change in the UPS State is displayed with a delay. 10

Software operation User Interface Dialogs Registry "ACU State" Show UPS State 2 ACU USV V3.x/V4.x/V5.x: Type Hardware Type Power OK/Fail Input Voltage State; OK or Failure UPS On/Off On: UPS functionality activated Delay Time [s] 0.00... 64.00 s Period of time to wait until a voltage failure is reported by the ACU UPS control unit. Thus, voltage fluctuations are filtered out. Buffer Time 4 min.; infinite Maximum period of time the industrial PC can be fed by the battery/capacitor pack, depending on the hardware. ACU State Current ACU State Display Firmware Version Displays the current ACU firmware version Note! A change in the UPS State is displayed with a delay. 11

2 Software operation User Interface Dialogs Registry "ACU Control" Configure UPS 2.3.2 Registry "ACU Control" Configure UPS Note! This registry is only shown when the ACU software has been called up via the system panel. It is not shown when the software is called up by double clicking the symbol in the information bar of the Windows task bar. ACU USV V2.x: Buffer Time [s] 0.00... 64.00 s Period of time to wait until a voltage failure is reported by the ACU UPS control unit. Thus, voltage fluctuations are filtered out. Delay Time 0... 240 s; infinite Maximum period of time the industrial PC can be fed by the battery/capacitor pack, depending on the hardware. Restart after Delay Time On/Off On: Restart or shutdown of the system when the delay time is up. UPS Activated On/Off On: UPS support activated Off: UPS support deactivated Auto off after shutdown On/Off On: The ACU UPS control unit is switched off right after the shutdown of the system. This function requires a system with ACPI support (ETX CD). Backlight off after Power Fail On/Off On: Deactivates the backlight of the TFT display in case of a voltage failure. 12

Software operation User Interface Dialogs Registry "ACU Control" Configure UPS 2 ACU USV V3.x: Delay Time [s] 0.00... 64.00 s Period of time to wait until a voltage failure is reported by the ACU UPS control unit. Thus, voltage fluctuations are filtered out. Buffer Time 4 min.; infinite Maximum period of time the industrial PC can be fed by the battery/capacitor pack, depending on the hardware. UPS Activated On/Off On: UPS support activated Off: UPS support deactivated ACU USV V4.x: Buffer Time [s] 0.00... 64.00 s Period of time to wait until a voltage failure is reported by the ACU UPS control unit. Thus, voltage fluctuations are filtered out. Delay Time 4 min.; infinite Maximum period of time the industrial PC can be fed by the battery/capacitor pack, depending on the hardware. Restart after Delay Time On/Off On: Restart or shutdown of the system when the delay time is up. UPS Activated On/Off On: UPS support activated Off: UPS support deactivated Backlight off after Power Fail On/Off On: Deactivates the backlight of the TFT display in case of a voltage failure. 13

2 Software operation User Interface Dialogs Registry "Time Set" Time Before Shutdown ACU USV V5.x: Delay Time [s] 0.00... 64.00 s Period of time to wait until a voltage failure is reported by the ACU UPS control unit. Voltage fluctuations are therefore filtered out. Buffer Time 4 min.; infinite Maximum period of time the industrial PC can be fed by the battery/capacitor pack, depending on the hardware. Restart On/Off On: Restart or shutdown of the system when the delay time is up. UPS Activated On/Off On: UPS support activated Off: UPS support deactivated Backlight off after Power Fail On/Off On: Deactivates the backlight of the TFT display in the event of a voltage failure. 2.3.3 Registry "Time Set" Time Before Shutdown ACU UPS Vx.x: Time Before Shutdown 0... 60 s Period of time from identifying a mains failure by the ACU UPS control unit until shutting down the IPC. This period of time must be shorter than the delay time ( 12) plus the period of time needed by the IPC to shut down. Example: The IPC can be supplied for 100 s by the battery pack and needs a maximum of 20 s for a safe shutdown. Delay time = 100 s Time before shutdown = < 80 s 14

Software operation User Interface Dialogs Registry "Application" Start External Programs 2 2.3.4 Registry "Application" Start External Programs ACU UPS Vx.x: While the ACU software counts down the seconds until the IPC is shut down after a voltage failure, an external program can be started. Executable Application Path of the executable program file of the application [Browse] Search executable program file Execute Application On/Off On: The program file specified in "Executable Application" is executed. 2.3.5 Registry "Shutdown" Force Shutdown ACU UPS Vx.x: Shutdown On/Off Default Setting Force Shutdown On/Off If you are using the default setting and an application prompts you to make a user entry when shutting down the PC, the PC cannot be shut down automatically. If the "Force Shutdown" option is activated, all programs are closed before the shutdown without considering feedbacks. Caution: This setting may lead to data loss. 15

2 Software operation User Interface Dialogs Registry "LogFile" View Program Messages 2.3.6 Registry "LogFile" View Program Messages ACU UPS Vx.x: All ACU software messages are recorded in the ACU.log file and can be viewed there. [Position Log File] Select the folder the ACU.log file shall be written to. [Show Log File] Display ACU.log File Note! The log file data is moved to the "ACU.bak" file when the file size reaches 64 KB so that the log file does not become too big. If you delete the "ACU.log" log file through the Windows Explorer, a new log file will be created as soon as a new log entry is available. It may be impossible to write the log file if the software is run under a user account with restricted access rights and if a folder other than the preconfigured folder has been assigned. So please ensure that the user account has the corresponding write permissions with regard to the log file folder. If a write filter (EWF or FBWF) is used: The log file need not be in a write protected area. 16

Software installation 3 3 Software Installation The ACU UPS control unit software is a factory set pre equipment if you chose this option when placing your purchase order and if you obtained the operating system via a Lenze storage medium. In other cases, start the setup program on the program CD and follow the instructions of the setup assistent. Note! After the ACU UPS software has been reinstalled, UPS functionality is deactivated for versions V3.x/V4.x/V5.x and activated for version V2.x. 17

12/2015 Lenze Automation GmbH Postfach 10 13 52, 31763 Hameln Hans Lenze Str. 1, 31855 Aerzen GERMANY HR Hannover B 205381 Service Lenze Service GmbH Breslauer Straße 3, 32699 Extertal GERMANY +49 5154 82 0 008000 2446877 (24 h helpline) +49 5154 82 2800 +49 5154 82 1112 lenze@lenze.com service@lenze.com www.lenze.com LDCDP EPC50ACU.SR6 EN 5.0 TD09 10 9 8 7 6 5 4 3 2 1