VSO MAX HP High Flow Proportional Valve



Similar documents
Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

OEM-EP Pressure Controllers

TTC-IIS Series Up to 11 LPM Free Flow

4 Posiflow Proportional Solenoid Valves

Model 111 Mass Flow Instruments

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

3/2-way pneumatic cartridge solenoid valve

BTC-IIS Series Miniature Diaphragm Pumps (air/gas)

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Assisted lift operated 2/2-way solenoid valves Type EV250B

3/2-way Mini Solenoid Valve

Confidential. Proportional reducer D386 ATEX. Male base connector View from weld side

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Single sub-base valve

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Centro-Matic Automatic Lubrication Systems System Controls

Cable Plug acc. to DIN EN , Form A

3/2-way Solenoid Valve, direct-acting, NC or NO

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

2/2 and 3/2 Way Size 6 Seat Valves

3/2- and 2/2-way cartridge valve type BVE

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

2.12. page Products for Explosion hazardous Environment

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

3 Port Solenoid Valve

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Digital inductive conductivity transmitter

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Sporlan V-Series Ruby Seat Solenoid Valves

SOLENOID VALVES AND PNEUMATIC VALVES

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Mono-Block II Installation & Operation Manual

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

Pressure transmitter For general industrial applications Model A-10

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers.

Electro-pneumatic control valves

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Typical Aluminum GFM Mass Flow Meter

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

System 8. ü ( System 8

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

API Marine. BMS Presentation. Ballast Measurement Systems

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Ball Valves (HB Series) Catalog 4121-HB Revised, April 2005

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Proportional Relief Valves

Chapter 5: Flow Valves

Proximity Switches RS (Reed Switch)

Many Products...One Source

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for Gases

Data sheet ECC 12 and 22

Electro-Pneumatic Bus Door Control Mechanism

Duct Humidity Transmitter

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Inductive sensor NI10-M18-Y1X-H1141

Electronic Pressure Monitoring New Products

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Valves. Sub-Base Mounted Valves to ISO 5599/2

Gas Mass Flow Control Products

167D Series Switching Valves

IOM SERIES 820-E/P Electro-Pneumatic Positioner

Solenoid valves 2/2-way direct-operated Type EV210A

DCP Fan Controller. Version 01/2009. The engineer s choice

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

AIR LINE VALVES AND GAUGES

type V46, solenoid or pneumatic operated

Veriflo Pressure Regulators

Solenoid Valve Island Type 3965

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Regulator Options and Accessories

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

PRODUCT PROFILE FEATURES

Chapter 6: Check Valves

Type 3353 Angle Seat Valve

Airflow Sensors Line Guide

HL Series - Commercial Heaters Tankless Water Heating Solutions

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Transcription:

VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties Valve Type: 2-Way Normally Closed Media: Air, argon, helium, hydrogen, methane, nitrogen, oxygen, & others Operating Environment: 41 to 131 F (5 to 55 C) Storage Temperature: -40 to 158 F (-40 to 70 C) Length: 2.02 in (51.4 mm) Width: 0.63 in (15.9 mm) Height: 0.69 in (17.4 mm) Porting: Manifold mount Weight: 2.45 oz (69.5 g) Body: Miniature High Flow Proportional Valve The VSO MAX HP is a miniature high flow proportional valve that provides maximum flow capabilities greater than 200 slpm @ 45 psi (8.27 bar), while consuming less than two watts of power. The valve delivers a high range of controllable flow while consuming 25% less power than comparable miniature proportional valves. In today s medical device industry, size is an important element. VSO MAX HP s operating pressure of up to 120 psi (8.27 bar) eliminates the need for an inlet regulator. This translates to a smaller, sleek medical device design and offers potential savings and features three standard control voltage ranges (5, 12 and 24 VDC). Features Delivers a wide range of controllable flow Provides repeatable flow performance over its rated life Cleaned for Oxygen service use Low power consumption generates less heat Proven performance tested to 25 million life cycles Reach and RoHS compliant Electrical Power: 2.0 Watts Maximum @ 20 C Voltage: See Table 1 Electrical Termination: 18 in Wire Leads Wetted Materials C36000 Brass Stem Base: 430 FR Stainless Steel C36000 Brass All Others: FKM; 430 FR Stainless Steel; Stainless Steel Performance Characteristics Leak Rate: The leakage shall not exceed the following values: Internal: 5.0 sccm of Air up to 120 psi (8.27 bar) External: 0.5 sccm of Air up to 120 psi (8.27 bar) Pressure: Operating: 0-120 psi (0-8.27 bar) Proof: 300 psi (20.7 bar) Orifice Sizes: 0.116 (2.95 mm) effective 0.200 (5.08 mm) actual Hysteresis: 7% of full scale current (Typical) 15% of full scale current (Max) Recommended Filtration: 40 Micron (not supplied) Response time: 10 ms Typical Reliability: 25 Million Cycles VSO is a registered trademark of Parker Hannifin Corporation.

VSO MAX HP Miniature High Flow Proportional Valve Typical Flow Curves Typical Air Flow with 12VDC 68 Ohm Coil (Tested w/air 20 C) Flow Rate (slpm) 300 275 250 225 200 175 150 125 100 75 50 25 0 120 psi / 8.27 bar 100 psi / 6.89 bar 60 psi / 4.14 bar 45 psi / 3.10 bar 30 psi / 2.07 bar 20 psi / 1.38 bar 10 psi / 0.69 bar 0 20 40 60 80 100 Current (ma) Flow Rate (slpm) 300 250 200 150 100 50 0 Pressure vs Flow 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 0.116" (2.95 mm) effective orifice Pressure (bar) 0 25 50 75 100 125 Pressure (psi)

Pneumatic Interface VSO MAX HP Manifold Mount Mechanical Integration Dimensions VSO MAX HP Manifold Body Basic Valve Dimensions VSO-MAX Basic Valve Dimensions.625 [15.88] MAX..67 [17.0] 2X Ø.128 [Ø3.25].830 [21.08] 2.024 [51.41] PORT 2 (OUTLET).345 [8.76].165 [4.19].329 [8.36] UNITS IN. [mm.].625 [15.88].625 [15.88].685 [17.40].313 [7.95].200 [5.08].400 [10.16] PORT 1 (INLET)

Electrical Interface VSO MAX HP Manifold Mount COIL TYPE: WIRE LEADS 2X #26 AWG. BLACK WIRES 18 1/2" ± 1/2" [469.9 ± 12.7] LG. Coil Type: 18 Wire Lead.625 [15.88] MAX. 1.77 [45.0] APPROX. Electrical Requirements Table 2: Electrical Table Requirements 1 Maximum Supply Voltage (VDC) Nominal Coil Resistance (Ohms) @ 20 C Control Current at Maximum Flow (ma) 5 11.9 423 12 68.4 170 24 273.6 85

Installation and Use INLET VSO MAX HP VALVE PRESSURE REGULATOR INPUT SIGNAL Typical Valve Set-up VSO MAX HP CURRENT DRIVER FLOW OR PRESSURE SENSOR/METER OUTLET VALVE DRIVER CIRCUIT Valve Electrical Control Basic Control: The VSO MAX HP valve can be controlled by either voltage or current; however, it is highly recommended that current control be employed to ensure the most repeatable valve flow performance. PWM Control: For PWM control, the signal applied to the valve should have a frequency of 5 khz or greater. Optimal frequency will be application dependent. Suggested VSO MAX HP Current Driver Schematic This simple current driver circuit draws only 1 ma at the input control (0-5VDC) and provides control for any VSO MAX HP configuration regardless of valve voltage or resistance. Table 2 (below) describes the recommended R1 and R2 resistor values based upon the full shut-off current. Table 2: Selectable Resistor Values for a Low Current (1mA) LM358-Based Current Driver Maximum Solenoid Voltage (VDC) Circuit Supply Voltage (VDC) Nominal Coil Resistance @ 20ᵒC (Ohms) Maximum Output Current from Circuit (ma) R1 (Ohms) R2 (Ohms) 5 7 11.9 425 4990 464 12 14 68.4 172 4990 178 24 26 273.6 85 4990 86.6

Installation and Use.240 [6.10] VSO MAX HP Manifold Dimensions 2X 4-40 UNC-2B.350 [8.89] CHAMFER.010 [0.25] X 45.475 [12.07] VSO-MAX 890-009034-001 Manifold Dimensions 2X Ø.25.52 [Ø6.35 13.2] TAP 1/8-27 NPT.33 [8.4] CHAMFER.010 [0.25] X 45.400 [10.16].164 [4.17].329 [8.36].300 [7.62] 1.00 [25.4].710 [18.03].300 [7.62].62 [15.7].200 [5.08].313 [7.95] 1.00 [25.4] (Ø.625 [Ø15.88]) THIS AREA TO HAVE A 63 FINISH 2X Ø.234.52 [Ø5.94 13.2] UNITS IN. [mm.] Ordering Information Sample Part ID 921 2 1 1 05 1 000 Description Series Type Pneumatic Interface Body /Elastomer Coil Voltage Electrical Interface Options 2: 120 PSI 1: Manifold Mount 1: Brass / FKM 05: 5 VDC 1: Wire Leads, 18" (45.7 cm) 12: 12 VDC 24: 24 VDC Accessories 191-000214-002: Screw 4-40 x 7/8" Stainless Steel, Socket Head Cap** **Not supplied with the valve. Used to mount the valve to a manifold. 190-007060-001: Spare Manifold Gasket, Quad Ring FKM* *Supplied with the valve. Used as a seal between the valve body and manifold. (2 Required) 890-009034-001: Manifold, Single Station, 1/8" NPT NOTE: In order to provide the best possible solution for your application, please provide the following requirements when contacting Applications Engineering: Media, Inlet & Outlet Pressures Minimum Required Flow Rate System Supply Voltage Media & Ambient Temperature Range ORDER ON-LINE Please click on the Order On-line button (or go to www.parker.com/precisionfluidics/vsomaxhp) to configure your VSO Max HP Non-Thermally Compensated Proportional Valve. For more detailed information, visit us on the Web, or call and refer to Performance Spec. #790-002506-001 and Drawing #890-003423-001. For more information call +1 603 595 1500 or email ppfinfo@parker.com Visit www.parker.com/precisionfluidics PPF-MPV-002/US March 2016