1 1 TC-IIS Series Up to 11 LPM Free Flow TC-IIS Miniature Diaphragm Pumps are a series of brush and brushless DC motor driven pumps which are tailored to meet the specific application performance requirements. The innovative compact designs incorporate leading edge technologies that allow them to operate more efficiently than existing pump designs. TC-IIS Pumps offer multiple component configurations allowing them to be used for either vacuum, pressure, or alternating vacuum and pressure operations. TC-IIS is ideal for compact, high flow, wide pressure ranges, long-life, low noise applications. Typical Applications Patient Monitoring Compression Therapy Hemodialysis Peritoneal Dialysis Respiratory Care Wound Therapy Medical/Training Mannequins Degassing Product Specifications Physical Properties Operating Environment 1 : 1 to 2 F (5 to 5 C) Storage Environment: - to 2 F (- to 1 C) Media: Air, Argon, Helium, Nitrogen, Oxygen, and other non-reacting gases Humidity: % Relative Humidity Noise Level 2 : As low as 5 in ( cm) Muffler recommended for additional noise reduction (see accessories) Pump Assembly Rated Life 3 : PMDC Iron Core rush - 3, hrs - 1, hrs (High Torque) - 1, hrs - 1, hrs Weight:. oz. (227 g) PMDC Iron Core rush 6. oz. (17 g) 11.6 oz. (3 g) (High Torque). oz. (25 g) Features The TC-IIS Series pump sets the highest benchmark for servicefree performance with our unique brushless DC motor design and advanced proprietary diaphragm elastomer. Incorporating the lightweight EZ Mount accessory facilitates simple system assembly while dampening vibration and reducing noise levels. The TC-IIS maximizes flexibility by offering several mount options, Our 1% oil and grease-free pump and compressor design maintains the purity of your system and are commonly used in FDA-approved systems. RoHS compliant. Electrical Motor Type (DC): PMDC Iron Core rush, (High Torque), Nominal Motor Voltages : 6,, or VDC Other voltages available upon request Electrical Termination: PMDC Iron Core rush: 22 AWG Wire Leads, Length 1 (25 mm) Motor: 22 AWG Wire Leads, Length (5 mm) Motor (High Torque): 22 AWG Wire Leads, Length (5 mm) : 22 AWG Wire Leads, Length (5 mm) Current Range 5 : - 1 ma Wetted Materials Diaphragm: EPDM, AEPDM, FKM Valves: EPDM, FKM Pump Head: Vectra (Liquid Crystal Polymer) Pneumatic Head Configuration: Dual Maximum Unrestricted Flow: 6 LPM (Series) 11 LPM (Parallel) Pressure Range: - ( bar) Series - 2 ( bar) Parallel Vacuum Range: - 25 (635 ) (Series) - (5 ) (Parallel) Filtration: microns - recommended Efficiency at Free Flow 6 PMDC Iron Core rush:.9lpm/watt (PN: D ) : 1.1LPM/Watt (PN: D ) : 1.LPM/Watt (PN: D ) : 1.3LPM/Watt (PN: D ) * See Appendix A for details.

2 5 2 Performance Specifications Flow (LPM) TC-IIS - PMDC Iron Core rush Motor TC-IIS - PMDC IRON CORE RUSH MOTOR Vacuum () - Pressure (bar) TC-IIS Series Power Usage (W) Vacuum () - Pressure () Max Flow Max Power Min Flow Min Power - Flow (LPM) TC-IIS - Motor TC-IIS - RUSHLESS SLOTTED MOTOR Vacuum () - Pressure (bar) Flow (LPM) Vacuum () - Pressure () Max Flow Max Power Min Flow Min Power TC-IIS - Motor TC-IIS - RUSHLESS SLOTLESS MOTOR Vacuum () - Pressure (bar) Vacuum () - Pressure () Max Flow Max Power Min Flow Min Power Power Usage (W) Power Usage (W) The above graph represents an example of performance for the pumps series handling air at feet (m) above sea level at 75 F ( C). Performance will vary depending on barometric pressure and media temperature. Curves are representative of standard pump configurations. Pump configurations could be customized for higher or lower flows, depending on specific customer requirements. Please contact Parker Precision Fluidics Applications Engineering for other considerations.

3 6 3 TC-IIS Series Sizing and Selection TC-IIS Series PMDC Iron Core rush Motor Motor (High Torque) Motor Efficiency Life 1 Cost Noise PMDC Iron Core rush (High Torque) Good etter - Up to 6% motor efficiency at low loads Good - 3, hrs est Good est - 1, hrs etter etter etter - up to 6% motor efficiency at high power levels with high torque capability est - 1, hrs Good est est - Up to 75% motor efficiency at high power levels est - 1, hrs Premium est Mounting Guidelines: racket options available for mounting consideration (See EZ Mount catalog pages). Hole in the center of the bottom of housing is for manufacturing only not to be used for mounting. Mounting holes are drilled for #6- self-tapping screws with 1/ (6 mm) thread engagement torque to in-lbs. (.5 N-m). Dimensions Port Connections: arbs are sized for 1/" (3 mm) ID tubing, 7- durometer recommended. Flow direction is marked on the pump head with arrows. 1/" ID OR 3/" ID TUING TC-IIS RUSH 1.1 PMDC Iron Core rush NOT TO E USED FOR MOUNTING "G" MOUNTING PATTERN SHOWN (OTHER MOUNTING OPTIONS AVAILALE) X.5 [3.2] MOUNTING HOLES

4 7 Mechanical Integration Dimensions 1/" ID OR 3/" ID TUING 1.1 TC-IIS Series Motor "G" MOUNTING PATTERN SHOWN (OTHER MTG OPTIONS AVAILALE) NOT TO E USED FOR MOUNTING X.5 [3.2] MOUNTING HOLES /" ID OR 3/" ID TUING 1.1 Motor (High Torque) NOT TO E USED FOR MOUNTING "G" MOUNTING PATTERN SHOWN (OTHER MOUNTING OPTIONS AVAILALE) X.5[3.2] MOUNTING HOLES

5 5 TC-IIS Series Dimensions 1/" ID OR 3/" ID TUING 1.1 Motor NOT TO E USED FOR MOUNTING "G" MOUNTING PATTERN SHOWN (OTHER MTG OPTIONS AVAILALE) X.5 [3.2] MOUNTING HOLES Electrical Integration and Motor Control PMDC Iron Core rush Motor 2 Wire Red (+), lack (-) Wire specification Other Motor Control Considerations 22AWG, Insulation OD.51 in (1. mm), 1 (25 mm) Wire Leads Motor Control Options 2 Wire Red (+), lack (-) 3 Wire (Speed Control) Red (+), lack (-), White (PWM) or Yellow (Analog) Wire (Speed Control & Feedback) Red(+), lack (-), White (PWM) or Yellow (Analog), lue (Tachometer) Wire specification 22AWG, Insulation OD.51 in (1. mm), (5 mm) Wire Leads The drive electronics for the LDC motors are integrated into the motor itself, all that is needed is a power supply with the sufficient voltage and current. Key Things to Remember The pump is not a pressure holding device. An external check valve is recommended, if there is a pressure holding requirement. Pump orientation does not affect performance or life.

6 9 6 Pulse Width Modulation (PWM) Pulse-width modulation is a commonly used technique for controlling DC motors. TC-IIS Series The average value of the voltage fed to the motor is controlled by turning a switch between the voltage supply and the motor on-and-off at a fast pace. The longer the switch is on compared to the off time, the higher the power supplied to the motor. The PWM switching frequency varies for different types of devices, and is selected based on how it affects the device. For example, some applications require a faster switching frequency to prevent audible noise or electrical noise. The term duty cycle describes the ratio of on-time to the period (one complete on-and-off cycle). Duty cycle is normally expressed as a percentage of on-time, 1% being full-power and 5% being half-power. The advantage of PWM is the reduction of power-loss due to switching versus other control methods. Parker Hannifin recommends controlling the pump using 15kHz - khz frequency range. Typical Flow Diagram Negative Pressure Wound Therapy FILTER OUT TO ATMOSPHERE X-VALVE CHECK VALVE TC-IIS PUMP VENT TO ATMOSPHERE PNEUMATIC PUMP LIQUID ISOLATION FILTER WOUND DRESSING WASTE CANISTER

7 5 7 TC-IIS Series Typical Flow Diagram Pick-up Head FILTER OUT TO ATMOSPHERE TC-IIS PUMP PNEUMATIC PUMP FILTER PICK-UP HEAD (ACTIVATED) PART Accessory Information Filter-Mufflers also available to assist with filtration and optimize noise reduction..7 [19.]. 5 [5] Part Number: (Filters to 1 microns) 2.39 [6.7]

8 51 Accessory Information EZ Mount available TC-IIS Series EZ Mount provides ease of installation and effective control of vibration transfer. EZ Mount was designed to mount easily to the Precision Fluidic TC-IIS Family of diaphragm pumps. Features Isolation feet on the EZ mount can be rotated in any one of three ninetydegree planes and is designed for top-down or bottom-up mounting providing simple installation. EZ Mount was designed to minimize weight added to the pump assembly. Approximate weights are: Style A -.63 oz (1 g), Style -.71 oz ( g). Effectively absorbs vibration to minimize most vibration-induced noise and vibration transfer into an instrument. Designed to keep height and size to a minimum. Engineered for Parker TC-IIS pumps to ease integration into your system. Physical Properties Operating Environment: 1-15 F (5-7 C) Humidity: - 95% Relative Humidity ase Plate: Noryl GTX Feet: Silicone Feet Insert: rass Hardware: Zinc-Plated Steel Dimensions Style A - Motor POSITIONS IN 9 DEGREE INCREMENTS EZ Mount kits include all necessary hardware and detailed instructions. Isolation Feet are available in either threaded or thru-hole clearance for standard #- or #6-32 (M3 for clearance hole only) hardware and can be mounted in any of three ninety-degree planes. Style - PMDC Iron Core rush Motor POSITIONS IN 9 DEGREE INCREMENTS

9 52 9 TC-IIS Series Chemical Compatibility Chart * Chemical Compatibility of Wetted Path Materials Chemical FKM EPDM AEPDM Vectra A1 Air Ozone (1 ppm) 2 Oxygen Ethylene (Ethene) Acetylene Propane 1 1 Methane 1 1 Nitrogen Carbon Dioxide Halothane (Up to 5%) 1 1 *The above is an Abbreviated Chemical Compatibility Chart. Please consult factory for details. Compatibility Legend 1. EXCELLENT Minimal or no effect 2. GOOD Possible swelling and/or loss of physical properties 3. DOUTFUL Moderate or severe swelling and loss of physical properties. NOT RECOMMENDED Severe effect and should not be considered Note: Consult factory for other gases. Ordering Information TC-IIS Dual Head Pumps - General Purpose Part No Free Flow D D7A D D D D D7A D D D Part No Vacuum: TC-IIS Dual Head Pumps - High Flow Vacuum: Free Flow D736A D D D D D D D Pressure: Pressure: Vac Vac Max Max Press Press Motor Type rush PMDC rush PMDC Motor Type VDC PCD* ma Wetted Materials 7 AEPDM, EPDM, EPDM AEPDM, EPDM, EPDM AEPDM, EPDM, EPDM 3 AEPDM, EPDM, EPDM 51 AEPDM, EPDM, EPDM 7 AEPDM, EPDM, EPDM AEPDM, EPDM, EPDM AEPDM, AEPDM, EPDM 5 AEPDM, EPDM, EPDM 37 AEPDM, EPDM, EPDM VDC PCD* ma Diaphragm, Valves, Gasket *PCD: Peak Current Draw Wetted Materials Diaphragm, Valves, Gasket 75 AEPDM, AEPDM, EPDM 15 AEPDM, AEPDM, EPDM 1 AEPDM, AEPDM, EPDM 55 AEPDM, AEPDM, EPDM 1 AEPDM, AEPDM, EPDM 75 AEPDM, AEPDM, EPDM 6 AEPDM, AEPDM, EPDM 5 AEPDM, AEPDM, EPDM TC-IIS Dual Head - High Pressure or Vacuum Vacuum: Pressure: Part No. FF Max PCD* Wetted Materials

10 D D D D7A Ordering Information D D D PMDC rush PMDC 3 AEPDM, EPDM, EPDM 51 AEPDM, EPDM, EPDM 7 AEPDM, EPDM, EPDM AEPDM, EPDM, EPDM TC-IIS Series AEPDM, AEPDM, EPDM 5 AEPDM, EPDM, EPDM 37 AEPDM, EPDM, EPDM 53 1 TC-IIS Dual Head Pumps - High Flow Part No Free Flow D736A D D D D D D D PCD* Wetted Materials 75 AEPDM, AEPDM, EPDM 15 AEPDM, AEPDM, EPDM 1 AEPDM, AEPDM, EPDM 55 AEPDM, AEPDM, EPDM 1 AEPDM, AEPDM, EPDM 75 AEPDM, AEPDM, EPDM 6 AEPDM, AEPDM, EPDM 5 AEPDM, AEPDM, EPDM Vacuum: Pressure: Part No. FF Max PCD* Wetted Materials 69 5 Vacuum: TC-IIS Dual Head - High Pressure or Vacuum D D76A D75C Pressure: Note: The Ordering Information Section includes a few selected part numbers for the product line. Other performances and configurations are available. Please contact your Sales Representative or an Application Engineer to discuss your application needs Vac Vac Max Press Press Motor Type Motor Type VDC VDC ma ma Diaphragm, Valves, Gasket *PCD: Peak Current Draw Diaphragm, Valves, Gasket 6 AEPDM, EPDM, EPDM AEPDM, AEPDM, EPDM 5 AEPDM, AEPDM, EPDM *PCD: Peak Current Draw Accessory Information Part No. Rev Date_5/9/ Filtering Level (Micron) Filter Area 1.71 in 2 (11 cm 2 ) Internal Volume. in 3 (3.9 cm 3 ) Max Temperature C Filter-Mufflers: To assist with filtration and optimize noise reduction. Tubing: Recommendation 1/" (3mm) ID. Operating Limitations: Min Temperature 32 C Max Pressure Pressure 65 PSI (. 65 PSI bar) Wetted Materials Polypropylene

11 5 11 TC-IIS Series Ordering Information EZ Mount for TC-IIS with PMDC Iron Core rush Motor Part Number Style Description A5S S D5S C5S EZ Mount for TC-IIS with (High Torque) Motor Part Number Style Description A5S S D5S C5S #- Threaded # Clearance #6-32 Threaded #6 / M3 Clearance #- Threaded # Clearance #6-32 Threaded #6 / M3 Clearance EZ Mount for TC-IIS with Motor Part Number Style 32-1-A5S S 32-1-D5S 32-1-C5S EZ Mount for TC-IIS with Motor Part Number 17-1-A5S S 17-1-D5S 17-1-C5S Style A A A A Description #- Threaded # Clearance #6-32 Threaded #6 / M3 Clearance Description #- Threaded # Clearance #6-32 Threaded #6 / M3 Clearance Please click on the Order On-line button below (or go to to configure the TC-IIS Miniature Diaphragm Pump for your application. Serviceable PPF products are designed for use through the rated life and Parker does not sell replacement parts, nor is it recommended to service these in the field Note: In addition to Parker s innovative and flexible pump designs, we offer applications engineering expertise to our customers in order to configure and recommend the optimal pump for the application. Contact Parker Applications Engineering to discuss and configure alternate pump configurations to meet your specific application requirements. Providing information on the following requirements will assist us in developing an optimal solution for your application: Noise Operating Pressure / Vacuum Power Consumption Life Requirement Description of pump function in the application Size Motor Control Media Voltage ORDER ON-LINE

12 55 TC-IIS Series Appendix A All performance data is typical based on standard conditions: 7 F and 1.7 psia (21 C and 1 bar). 1. Duty Dependent. For operation above 2 F (5 C) consult factory 2. Noise is dependent on the configuration and operation of the pump in the application. Parker has the ability to tailor the pump configuration when noise is a critical criterion in the effort to meet the performance requirements of the application. Noise level is tested to Parker protocol P Life rating can vary depending on application and operating conditions.. Custom motor options available. Custom motors may require a significant application potential. The standard motors can be configured with a special winding to meet a particular operation point at a specified voltage 5. Current range is dependent on motor type, voltage, pressure/vacuum and flow requirement. Lower levels possible depending on application. 6. Pump efficiency is a measure of the flow rate generated per unit of power consumed. Efficiency may change dependent on application and operating condition at free flow. 13 Parker Hannifin Corporation PPF MDP - 2/US October 13 Parker Hannifin Corporation Precision Fluidics Division 26 Clinton Dr., Unit 13 Hollis, NH 9 phone: [email protected]

TTC-IIS Series Up to 11 LPM Free Flow

TTC-IIS Series Up to 11 LPM Free Flow 66 Up to 11 LPM Free Flow Typical Applications Gas Analysis Anesthesia Monitors CO 2 Monitors Patient Monitoring Wound Therapy Urinalysis Trace Detection Medical/Training Mannequins Degassing Product Specifications

More information

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC 8mm Solenoid Valve Typical Applications Portable Equipment Blood Pressure Monitoring Wound Therapy Air and Oxygen Delivery Sensor Zeroing Product Specifications Mechanical Valve Type: 3-Way, Solenoid-actuated

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

OEM-EP Pressure Controllers

OEM-EP Pressure Controllers Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

T U R B I N E G A S M E T E R

T U R B I N E G A S M E T E R TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss

More information

QR12 (1.22 ) Diameter Optical Encoder

QR12 (1.22 ) Diameter Optical Encoder Improving the Quality of Life through the Power in Light QPhase QR12 (1.22 ) Diameter Optical Encoder Design Features: Low profile assembled height of Bearing design simplifies encoder attachment Resolutions

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: [email protected] Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

EFC 3600. Frequency converters

EFC 3600. Frequency converters 2 Bosch Rexroth AG Electric Drives and Controls Documentation Compact and complete: space saving side-by-side assembly, plug-in I/O terminals, with brake chopper and mains filter for ultra-simple installation

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

KNC Model 3666 Automatic Pressure Calibration System

KNC Model 3666 Automatic Pressure Calibration System KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

SYSTEM 45. C R H Electronics Design

SYSTEM 45. C R H Electronics Design SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

DCP Fan Controller. Version 01/2009. The engineer s choice

DCP Fan Controller. Version 01/2009. The engineer s choice Version 01/2009 The engineer s choice Index Page 1. Introduction... 3 2. Technical specification... 4 3. Connection diagrams... 9 4. Configuration... 10 5. Compatible ebm-papst Fan List... 11 2 1. Introduction

More information

Description. Dimensions. Features. www.pwb-encoders.com. precision works better

Description. Dimensions. Features. www.pwb-encoders.com. precision works better Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

SYSTEM 4C. C R H Electronics Design

SYSTEM 4C. C R H Electronics Design SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25

More information

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by

More information

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request. LEAKVALVE: HIGHLIGHTS The core of this valve is a diaphragm in stainless steel 316L, gold plated. Robust, it cannot be damaged with any normal methods. The dead volume is kept as small as possible. There

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Encoders. the incremental encoders format such as relective optical technology, transmissive optical technology

Encoders. the incremental encoders format such as relective optical technology, transmissive optical technology the incremental encoders format such as relective optical technology, transmissive optical technology back devices, brakes and gearboxes at no extra cost to you. USA: +1 267 933 2105 Europe: +33 20928751

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Micro GC Fusion Pre-Installation Checklist

Micro GC Fusion Pre-Installation Checklist Site Preparation Proper site preparation prior to installing is very important. Contact INFICON (www.inficon.com) with any questions regarding site preparation. NOTE: Checkboxes ( ) identify hardware that

More information

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Pipe Cutting and Beveling Clamshells

Pipe Cutting and Beveling Clamshells Pipe Cutting and Beveling Clamshells Who We Are One Company, Total Support, Complete Solutions For more than a century, Hydratight has provided world-class bolted joint solutions and continues to set international

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Three Channel Optical Incremental Encoder Modules Technical Data

Three Channel Optical Incremental Encoder Modules Technical Data Three Channel Optical Incremental Encoder Modules Technical Data HEDS-9040 HEDS-9140 Features Two Channel Quadrature Output with Index Pulse Resolution Up to 2000 CPR Counts Per Revolution Low Cost Easy

More information

Gas Custody Transfer Calibration

Gas Custody Transfer Calibration Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform

More information

Miniature High-Torque, DC Servomotors and DC Gearmotors

Miniature High-Torque, DC Servomotors and DC Gearmotors typical applications Robotics Factory automation Medical equipment Computer peripherals and office equipment Portable, battery-operated equipment Textile machinery Packaging machinery Actuators Miniature

More information

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where

More information

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY

More information

PROXIMITY CARD READERS C-10, C-20, C60, C70

PROXIMITY CARD READERS C-10, C-20, C60, C70 Installation Manual PROXIMITY CARD READERS C-10, C-20, C60, C70 VERSION 1.0 CONTENTS 1. General information................................. 3 2. Technical data......................... 4 3. Connection

More information

167D Series Switching Valves

167D Series Switching Valves June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are

More information

Borstlösa DC-motorer. Promoco Scandinavia AB

Borstlösa DC-motorer. Promoco Scandinavia AB Borstlösa DC-motorer Promoco Scandinavia AB BL Series Brushless DC Motors with Integral Drive 24, 54, 68, and 70 mm diameters, 2W up to 110W output power Allied Motion s BL series of small brushless DC

More information

Laserlyte-Flex Alignment System

Laserlyte-Flex Alignment System Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning

More information

O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications

O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51 DC Input BLH Series Brushless DC Motors Intro duction BLF BLU BLH Installation C Input DC Input Page BLH Series B-52 B-51 RoHS-Compliant Brushless DC Motor and Package BLH Series The BLH Series combines

More information

SECTION 13. Multipliers. Outline of Multiplier Design Process:

SECTION 13. Multipliers. Outline of Multiplier Design Process: SECTION 13 Multipliers VMI manufactures many high voltage multipliers, most of which are custom designed for specific requirements. The following information provides general information and basic guidance

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) FBR46 SERIES RoHS compliant FEATURES Miniature size About 50% smaller in volume compared with the FBR240 series used mainly in communication equipment.

More information

API Marine. BMS Presentation. Ballast Measurement Systems

API Marine. BMS Presentation. Ballast Measurement Systems API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented

More information

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...

More information

DC Motor control Reversing

DC Motor control Reversing January 2013 DC Motor control Reversing and a "Rotor" which is the rotating part. Basically there are three types of DC Motor available: - Brushed Motor - Brushless Motor - Stepper Motor DC motors Electrical

More information

Vacuum chucking. MDAE Woodturning Center Course Number 95537001

Vacuum chucking. MDAE Woodturning Center Course Number 95537001 Purpose of vacuum chucking Vacuum chucking MDAE Woodturning Center Course Number 95537001 Completing the foot of a vessel Re chucking a completed object Quick securing for additional steps (sanding) How

More information

15/40/80CN Series Coreless Medium Pressure Filters

15/40/80CN Series Coreless Medium Pressure Filters //8CN Series Coreless Medium Pressure Filters //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment Pilot

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference

More information

Analog Servo Drive 25A8

Analog Servo Drive 25A8 Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas SFS81 Series Servo Finishing Stand PUSHCORP, INC. Dallas, Texas May, 2012 NEVER OPERATE THE SFS81 MANUALLY NEVER OPERATE THE SFS81 WITH PERSONEL IN THE WORKCELL DO NOT USE LUBRICATED AIR. This device requires

More information

Technical Specification. Generating Set with Waukesha engine burning natural gas

Technical Specification. Generating Set with Waukesha engine burning natural gas Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the

More information

Installation, Operation, Repair and Parts Manual

Installation, Operation, Repair and Parts Manual 2088 Agricultural Series Pumps Installation, Operation, Repair and Parts Manual Form 911-396 6/11, Rev. A Description Model 2088-343-135 Automatic-Demand Pumps / 12 VDC These SHURflo 2088 Series diaphragm

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS PORTER MASS MEASUREMENT AND CONTROL SYSTEMS PORTER: THE STANDARD OF EXCELLENCE IN MASS Porter Mass Flow products reflect nearly three decades of experience in the design and manufacture of precision instruments

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET: SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the

More information

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

Permanent Magnet DC Motors

Permanent Magnet DC Motors typical applications Robotics and factory automation Pick-and-place robots Positioning tables Welding wire feeders Automatic guided vehicles Barcoding equipment Computer and office equipment Copier and

More information

XL PREMIUM OIL COOLER KIT

XL PREMIUM OIL COOLER KIT -J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English

More information

Regulator Options and Accessories

Regulator Options and Accessories Regulator Options and Accessories Regulator accessories are available separately or mounted on Swagelok regulators. Some accessories limit regulator pressure or temperature ratings. Additional materials,

More information

PIEZOMETER AIRFLOW MEASURING RING

PIEZOMETER AIRFLOW MEASURING RING PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

Mitos P-Pump. product datasheet

Mitos P-Pump. product datasheet product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. 7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND

More information

T a b l e o f C o n t e n t s

T a b l e o f C o n t e n t s w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company

More information

Types 66R and 66RR Low-Pressure Relief Valves

Types 66R and 66RR Low-Pressure Relief Valves November 2009 Types 66R and 66RR Low-Pressure Relief Valves W1953 W1908 TYPE 66R RELIEF VALVE TYPE 66RR RELIEF VALVE Figure 1. Typical Constructions Introduction Types 66R and 66RR low-pressure throttling

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Vert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table

Vert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table Version MH-C MH-C2 Electrical data Measuring range 0... 360 - Indep. linearity % meas. range ±0.3 - Max. hysteresis 0.1 - Resolution bit 12 - Max. repeatability 0.1 - Sample rate fast mode khz (5) - Sample

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information