Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for Gases
|
|
|
- Sabrina Wheeler
- 10 years ago
- Views:
Transcription
1 Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for Gases Type 8746 can be combined with Inline MFC/MFM for full scale rates from 2 l N /min to 15 l N /min, MFM up to 25 l N /min High accuracy and repeatability Protection class IP65 Communication via fieldbus based on CNopen Optional: TEX Zone 2 compliance Type ME2X System Control Unit with Gateway functionality Type 8746 for high flow rates can be configured either as MFC or MFM and is intended for the use in a büs or CNopen network. The büs network technology which is based on CN physics was developed by Bürkert especially for applications with quite a number of control loops run by Industrial Ethernet or other fieldbuses. The System Control Unit (SCU) Type ME2X (please see datasheet) transfers a customer s PLC fieldbus into the proprietary büs communication and operates all connected electronic devices. The communication of the devices can be switched from büs to CNopen. Given that, Type 8746 can also be integrated into an existing CNopen infrastructure. Type 8746 meters (MFM) or controls (MFC) the mass flow of gases using an inline sensor. The sensor works according to the thermal principle (constanttemperature anemometer). The measurement is made in the main channel and therefore reaches very fast response times of a few hundred milliseconds. The MFC/MFM can be optionally calibrated for two different gases, the user is able to switch between them. direct-acting solenoid control valve as regulating unit ensures high sensitivity and good flow control of the device. Type 8746 is especially designed for use in harsh environments due to a low sensitivity to contamination, high IP and explosion protection (see p. 2). Technical data Nominal flow range (Q nom ) 2 to 15 l N /min (N 2 ), MFM up to 25 l N /min (N 2 ) Turn-down ratio 5:1 1) Operating medium Neutral, non-contaminated gases, (others on request) Calibration medium Operating gas or air Max. operating 1 bar (with MFCs the max. pressure pressure depends on the orifi ce of the valve) optional up to 25 bar for MFM Medium temperature -1 C to +7 C (-1 C to +6 C with oxygen) mbient temperature -1 C to +45 C (higher temperatures on request) ccuracy ±1.5% v.m. ±.3% v.e. (after 1 min. warm up time) Repeatability ±.1% v.e. Settling (MFC)/ < 5 ms response(mfm) time (t 95% ) Materials Body Stainless steel or aluminium Housing luminium die casting (coated) Seals FKM or EPDM (depending on gas) Port connection G 1/4, 3/8, 1/2, 3/4, 1, NPT 1/4, 3/8, 1/2, 3/4, 1 1) With vertical installation and fl ow downwards the turn-down ratio is 1:1 Technical data Control valve (prop. normally closed valve) Valve orifi ce range.8 to 12 mm k v s value range.2 to 2.5 m 3 /h Electr. connection M12 plug, 5-pin Operating voltage 24V DC Voltage tolerance ± 1% Power consumption Max W (as MFM), Max. 19 to 37 W (as MFC, independent from Proportional valve Type) Residual ripple ± 2% Digital Comm. CNopen or CN based büs Removable memory EEPROM (SIM card: büs relevant data and information about spec. control loop in order to ease replacement) Input-/ Output signals none, communication via bus Protection class IP65 and IP67 TEX compliance II 3G Ex n IIC T4 Gc 2) Dimensions See drawings on p. 4-7 Total weight ca. 1.8 kg (l, 16 W-valve), ca. 3.1 kg (V, 16 W-valve) Installation Horizontal or vertical Device status RGB-LED based on NMUR NE17 2) acc. to DIN EN 679-:21-3 and DIN EN :21 p. 1/9
2 Nom. flow ranges of typical Gase (Other gases on request) Gas Min. Q Nom [l N /min] Max. Q Nom [l N /min] cetylene mmoniac rgon 2 15 Carbon dioxide 2 8 ir 2 15 (MFM 25) Methane 2 75 Propane 2 4 Oxygen 2 15 (MFM 25) Nitrogen 2 15 (MFM 25) Features to fulfill the TEX requirements The operation of Type 8746 without restrictions in Zone 2, Kat. 3 is ensured by the following features: Impact protection cap prevents damage of the M12 plug and all connected elements if mechanical stress is applied. No particular TEX sockets are required Standard requirements for cable glands are fulfilled for versions with external valve Screws prevent uncoupling of the M12 connection under tension Diecast housing maintains IP protection under high mechanical stress LED display protected against mechanical stress M12 plug achieves protection class IP65 and IP67 with and without mounted counterpart Pressure Loss Diagram of a MFM (ref. to air, with 25μm inlet filter) p [mbar] G1/4 G3/8 G1/2 G3/4 G Q [ln/min] The diagram shows exemplarily the pressure loss characteristics when air flowing through. For determining the pressure loss with another gas it needs to calculate the air equivalent and respect the fluidics needed with the other gas. Notes Regarding the Configuration For the proper choice of the actuator orifice within the MFC, not only the required maximum flow rate Q nom, but also the pressure values directly before and after the MFC (p 1, p 2 ) at this flow rate Q nom should be known. In general, these pressures are not the same as the overall inlet and outlet pressures of the whole plant, because usually there are additional flow resistors (tubing, additional shut-off valves, nozzles etc.) present both before and after the controller. Please use the request for quotation form on p. 8 to indicate the pressures directly before and after the MFC. If these should be unknown or not accessible to a measurement, estimates are to be made by taking into account the approximate pressure drops over the flow resistors before and after the MFC, respectively, at a flow rate of Q nom. In addition, please quote the maximum inlet pressure p 1max to be encountered. This data is needed to make sure the actuator is able to provide a close-tight function within all the specified modes of operation. The request form on page 8 contains the relevant fluid specification. Using the experience of Bürkert engineers already in the design phase provide us with a copy of the request containing the necessary data together with your inquiry or order. p. 2/9
3 Measuring Principle This sensor works as a hot-film anemometer in the so-called CT operational mode (Constant Temperature nemometer). To do this, two resistors with precisely specified temperature coefficients located directly in the media flow and three resistors located outside the flow are connected together to form a bridge. The first resistor in the gas flow (RT) measures the fluid temperature, while the second, low-value resistor (RS) is heated so that it is maintained at a fixed, predefi ned over-temperature with respect to the fl uid temperature. The heating current required to maintain this is a measure of the heat being removed by the fl owing gas, and represents the primary measurement. n adequate flow conditioning within the MFC and the calibration with high-quality flow standards ensure that the mass of gas flowing per time unit can be derived from the primary signal with high accuracy. Software Bürkert Communicator Part of Bürkert s new EDIP program (Efficient Device Integration Platform) is the Bürkert Communicator. This software can be run under MS-Windows and allows users to program further parameters in MFCs or watch process controls. It is freely available on Bürkert s website. n accessory part, the büs stick please see ordering chart for accessories, serves as the interface between computer and process instrument I want to connect to. It transfers USB data to CN data. The Communicator allows: - Diagnosis - Parameterization - Registration and storage of process data - Data logging - To watch graph of process - To update firmware of the büs device connected - To program system controls by User-f(x) e.g. gas blending - Pin Configuration M12 Plug, 5-pin (-coded) Pin Configuration 1 SHIELD V Coding 3 DGND 4 CN_H 5 CN_L p. 3/9
4 Dimensions [mm] MFC with valve type 2873 (9 W-coil) 4 x M4 1 4 ca G 1/4; NPT 1/4 G 3/8; NPT 3/8 p. 4/9
5 Dimensions [mm] MFC with valve type 2875 (16 W-coil) 4 x M Version with standard base block ca G 1/4; NPT 1/4 G 3/8; NPT 3/ Version with base block for large nominal flow rates ca G 1; NPT 1 p. 5/9
6 Dimensions [mm] MFC with valve type 2836 (24 W-coil) 4 x M4 1 ca Version with standard base block G 1/4; NPT 1/4 G 3/8; NPT 3/ Version with base block for large nominal flow rates G 1; NPT 1 p. 6/9
7 Dimensions [mm] MFM version 4 x M Version with standard base block G 1/4; NPT 1/4 G 3/8; NPT 3/8 Version with base block for large nominal flow rates G 1; NPT 1 p. 7/9
8 Ordering Chart for ccessories rticle Item no. büs cable extension M12.1m büs cable extension M12.2m büs cable extension M12.5m büs cable extension M12 1m büs cable extension M12 3m Connector M12, female, straight 1) Connector M12, male, straight 1) Connector M12, female, angled 1) Connector M12, male, angled 1) Y junction Y junctionr for connecting two separately powered segments of a büs network Termination resistor 12 Ohm M12 male Termination resistor 12 Ohm M12 female büs-stick Set 1 (incl. cable (M12)) büs-stick Set 2(incl. cable (M12), büs termination, power supply, and software) SIM card on request Software Bürkert Communicator Download from 1) It is possible that the M12 connectors cannot be used together on the same side of a Y-junction. If that is the case, please use a prefabricated cable which uses typically a thinner connector. Male M Female M OR termination resistor male termination resistor female Y junction Y junction Power interrupt The coding of the M12 plug (see p.3) and the housing limit the orientation of the Y or T-junctions. If you select and use your own junctions, please consider these limitations. Female M12 with cable Male M12 with cable Female M p. 8/9
9 MFC/MFM-applications - Request for quotation Please complete and send to your nearest Bürkert sales centre Company Contact person Customer No ddress Postcode/Town Department Tel./Fax MFC-pplication MFM-pplication Quantity Required delivery date TEX compliance Medium data Type of gas (or gas proportion in mixtures) Density kg/m 3 8) Gas temperature [ºC or ºF] ºC ºF Moisture content g/m 3 brasive components/solid particles no yes, as follows: Fluidic data Flow range Q nom Min. l N /min 8) l S /min (slpm) 9) Max. m N3 /h 8) kg/h cm N3 /min 8) cm S3 /min (sccm) 9) l N /h 8) l S /h 9) 1) Inlet pressure at Q nom p 1 = bar(g) Outlet pressure at Q nom p 2 = bar(g) Max. inlet pressure P 1max bar(g) MFC/MFM port connection without screw-in fitting 1/4 G-thread (DIN ISO 228/1) 1/4 NPT-thread (NSI B1.2) with screw-in fitting (acc. to specification for pipeline) mm Pipeline (external Ø) inch Pipeline (external Ø) Flange version Installation horizontal vertical, flow upwards mbient temperature C vertical, flow downwards Material data Body base luminium Stainless steel Seal FKM EPDM Electrical data Signals for set point CNopen or büs and actual value Please quote all pressure values as overpressures with respect to atmospheric pressure bar(ü) 8) 9) 1) at: 1,13 bar(a) and ºC at: 1.13 bar (a) and 2 ºC matches with calibration pressure To find your nearest Bürkert facility, click on the orange box g In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 155/2_EU-en_89528 p. 9/9
Control- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
3/2-way Mini Solenoid Valve
3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
Battery Powered Digital Mass Flow Meters for Gases
Next Generation red-y compact: AA Battery Powered Touch Technology Micro-UB Port red-y compact series product information Battery Powered Digital Mass Flow Meters for Gases Independent digital convenience:
VSO MAX HP High Flow Proportional Valve
VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
Battery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized
Battery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized
Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and ontrollers for Gases Reliable and accurate: Thermal Mass Flow Meters and ontrollers Reliable technology and standardized interfaces make
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
OPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
3/2-way pneumatic cartridge solenoid valve
3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
Proportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
OPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
Thermal Mass Flow Meter (Series MST)
Overview MaxiFlo TM MST series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate measurement of mass flows for various gases. It measures the mass flow of gas based on constant
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured
Typical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
T U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
The Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers. www.sierrainstruments.com
Process Gas Mass Flow Meters and Controllers Features n Direct monitoring of mass flow eliminates need for ancillary pressure and temperature sensing n Patented straight sensor tube with access ports permits
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
Model 111 Mass Flow Instruments
111 Mass Instruments Porter Mass products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement and control of gas flow. They incorporate design
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters M-4270/0707, pg. 2 of 29 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Gas Mass Flow Control Products
Gas Mass Flow Control Products The Standard of Excellence in Mass Flow Porter Mass Flow products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
In semiconductor applications, the required mass flows
Model-Based Multi-GasMulti-Range Mass Flow Controllers With Single Gas Calibration and Tuning JOOST LÖTTERS A model has been developed that accurately predicts the behavior of the flow sensor combined
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
OEM-EP Pressure Controllers
Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS
PORTER MASS MEASUREMENT AND CONTROL SYSTEMS PORTER: THE STANDARD OF EXCELLENCE IN MASS Porter Mass Flow products reflect nearly three decades of experience in the design and manufacture of precision instruments
DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: 0.05 40376 m 3 /h. Accuracy: ± 0.3% of reading ± 0.
Magnetic Inductive Flowmeter for conductive fluids measuring monitoring analysing MH Measuring range: 0.05 40376 m 3 /h ccuracy: ± 0.3% of reading ± 0.01% x Q max p max : PN40; t max : -20... +150 C O
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters
Data Sheet Brooks Digital MFC's & MFM's Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters GENERAL FEATURES Wide FS flow range for measurement
Solenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
Single sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
Precision Mass Flow Meters / Controllers for Liquids and Gases
CORI-FLOW Precision Mass Flow Meters / Controllers for Liquids and Gases > Introduction Bronkhorst High-Tech B.V., the European market leader in thermal Mass Flow Meters/Controllers and Electronic Pressure
Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32
www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC
8mm Solenoid Valve Typical Applications Portable Equipment Blood Pressure Monitoring Wound Therapy Air and Oxygen Delivery Sensor Zeroing Product Specifications Mechanical Valve Type: 3-Way, Solenoid-actuated
2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
VAD. Variable Area Desuperheaters
Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
Fundamentals of Mass Flow Control
Fundamentals of Mass Flow Control Critical Terminology and Operation Principles for Gas and Liquid MFCs A mass flow controller (MFC) is a closed-loop device that sets, measures, and controls the flow of
Solenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
2/2 and 3/2 Way Size 6 Seat Valves
2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL
Solenoid Valve Type 3962
Solenoid Valve Type 362 x d, x em or without explosion protection, for controlling pneumatic actuators General The Type 362 Solenoid Valve ensures a high level of operational reliability for controlling
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Relative and absolute pressure switch type 529
Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20
Actuators and positioning drives
Actuators and positioning drives distributed by www.laumans.com Actuators and positioning drives FlexiDrive product range type MDBA 42 MSQA 46 MSAA 42 Actuator Actuator Actuator motor brush DC motor brush
OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
Variable Area Flowmeters
www.swagelok.com Variable Area Flowmeters G Series and M Series Glass and metal (armored) tube models, including miniature armored model Highly accurate measurement with individually calibrated scales
Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve
Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective
System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
Pressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
Mass Flow Meters & Controllers
HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2% of Full Scale) 0-5 VDC or 4-20
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Laminar Flow Elements
Laminar Flow Elements Meriam Laminar Flow Elements (LFEs) are excellent for measuring low gas flow rates from 0.2 SCCM up to 2250 SCFM. They are inherently accurate and repeatable and are calibrated traceable
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
VAD Variable Area Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.
LEAKVALVE: HIGHLIGHTS The core of this valve is a diaphragm in stainless steel 316L, gold plated. Robust, it cannot be damaged with any normal methods. The dead volume is kept as small as possible. There
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8
Type code Ident no. 1545007 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm Cable max. 50 m between interface and read/write head 2 decimal rotary coding switches for the adjustment
HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES. Page 1 Version no.: V0-090902
Page 1 HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES Page 2 Heavy-Duty Hand Cutting Torch HCT 663: With lever-operated valve for cutting oxygen, for cutting duties involving high thermal loads on slabs,
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD
INGOLD Leading Process Analytics Retractable Housings InTrac Retractable Sensor Housings for Harsh Applications Wide Range of Options Intelligent Sensor Locking System Highly Efficient Sensor Cleaning
Flow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual
Directional seated valves type VP 1
Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual
Turbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
Precision Mass Flow Metering For CVD Applications.
Precision Mass Flow Metering For CVD Applications. Ir. H.J. Boer Research Department of Bronkhorst High-Tech B.V. Nijverheidsstraat 1A, 7261 AK Ruurlo The Netherlands. Tel: +31 (0)573 458800 Fax: +31 (0)573
Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article
F e a t u r e A r t i c l e Feature Article Development of a High Accuracy, Fast Response Mass Flow Module Utilizing Pressure Measurement with a Laminar Flow Element (Resistive Element) Criterion D200