1 WATERFLUX - Comparisonon COO 2010-08-17. Rectangular Magmeter in water applications



Similar documents
IFC 070 Technical Datasheet

Electromagnetic Flow Meter

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

VAD Variable Area Desuperheaters

Hydraulic Control Solutions

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

VAD. Variable Area Desuperheaters

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

SITRANS F M MAG 8000 Precise Metering with battery powered water meters. sitrans f

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Water Loss Auditing and Water Leak Detection: How Much is Being Lost and Where Does it Go? PNWS-AWWA Annual Conference Michael W. Grimm, P.E.

The Unique Accelabar Flow Meter

COMBIMASS. Technical Data COMBIMASS eco-bio +

Series DFMT Digital Paddlewheel Flowmeter

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

THERMA-TUBE preinsulated pipes and fittings Catalogue of products

Underground Storage Tanks

APPLICATION SAMPLES. Measurement solutions for water applications

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

How To Use A Flowmeter

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

WATER METER CALIBRATION, REPAIR, AND REPLACEMENT PROGRAM

Energy and Flow Measurement for Hydronic Systems

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

Solar Hot Water Heaters

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

Reduce Leaks Using water audits and leak detection surveys

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

Open channel & partially filled pipe Ultrasonic flow meters

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

FLUID FLOW Introduction General Description

Frequently Asked Questions

SIZING AND CAPACITIES OF GAS PIPING

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Specifications for Residential Property Owners Connection to New Public Sewer

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW ASME Fluids Engineering Division Summer Meeting

API Marine. BMS Presentation. Ballast Measurement Systems

Engineering & Expertise Designing Pump Sumps

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

District Cooling Best Practices Piping Systems

DSRQ - DSRSQ - DSRSQ-THERM

SOIL RESISTIVITY MEASUREMENTS

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

This will also provide you with the knowledge to insure long life for your Investment

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE

Pipe Bursting. Case Study at Zeeland, MI Collections Seminar September 6, Presentation Agenda. What is Pipe Bursting? What is Pipe Bursting?

Emergency Spillways (Sediment basins)

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

Various Technics of Liquids and Solids Level Measurements. (Part 3)

SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

SHOWERS SHOWERS

T U R B I N E G A S M E T E R

Fluxi 2000/TZ Turbine Gas Meter

Fundamentals of Mass Flow Control

How To Use A Corona Mdi 110

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

The Axial Flow Valve. Class 300/ SERIES

SANITARY SEWER SPECIFICATIONS

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Water Metering System SmartMeter Prepayment. SmartMeter Prepayment. Water Metering System

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Oil and Gas Custody Transfer

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Recommendations for Marking Communication Facilities with Use of 3M EMS Electronic Markers

Measurement & Analytics. VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Meeting the Challenge of Pipeline Emergency Repair

Flow Measurement Options for Pipeline and Open Channel Flow

Understanding the Flo-Dar Flow Measuring System

swimming pool accessories

Leakage Management & Control

Comparison of Bearings --- For the Bearing Choosing of High-speed Spindle Design. Xiaofan Xie. Dept. of Mechanical Engineering, University of Utah

AMTRON E-30 Compact heat and cooling meter

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND TELECOMMUNICATION CABLES IN THE VICINITY OF TRANSPORTATION FACILITIES

BB-18 Black Body High Vacuum System Technical Description

RITTER Multiple Sonic Nozzle Calibration System

How To Read A Pipe From A Sensor

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

TRENCHLESS TECHNOLOGY GUIDELINES CLOSE FIT THERMOPLASTIC LINING

HEAVY OIL FLOW MEASUREMENT CHALLENGES

environment briefing02

Pool technologies and solutions. swimming pool update

1. The diagram below represents magnetic lines of force within a region of space.

Trace Layer Import for Printed Circuit Boards Under Icepak

Mandatory Part 1.4 BUILD OVER OR NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

Transcription:

1 WATERFLUX - Comparisonon COO 2010-08-17 Rectangular Magmeter in water applications Jef Neven KROHNE

WATERMETERS $3000 EMF Price C&I (mechanical) water meters Residential water meters $30

Water Metering Costs of water metering Costs Include Capital costs Purchase of water meters (Prefabricated) Shafts Engineering & Installation Planning, drawings, soil reports Major and costly plumbing work for new installations: Site set-up, Excavation & disposal, Dewatering Meter reading Recurrent costs to read meters Bills based on consumption instead on monthly flat fees Pressure loss Higher pumping costs = Higher energy costs Maintenance Wear of meters, break down, Repairs or replacements Verification Inaccuracy Low flows, large variations in flow, flow disturbances Non revenue metering Apparent losses due to inaccurate measurements, etc Real losses e.g. due to pipeline leakages, etc

Development Constraints for Batterymag

Development Constraints for Batterymag Stable measurement (Low Noise) MID and OIML compatible Rangeability 400!!!!( 1% accuracy between 8m/s and 20 mm/s) Battery live time, install and forget Installation conditions Potable water approvals, worldwide Neglegible pressure dropp Low Cost

To make the above happen we need 1.The physics (Square shaped tube) 2.Optimal flow-tube construction 3.Adapted water contacting materials 4.Optimized magnetic system

EMF principle

1 The physics The square shaped measuring section, reason and advantages: 1.Flow profile independency: B v everywhere in the tube, pole plates parallel close to each other B Homogeneous over the measuring section B-field picture next page Signal contribution homogeneous over the measuring section 2.Flow profile disturbances squeezed out by contraction PTB picture next page 3.Velocity doubling. 4.Magnetic yoke distance decreased by 2 Magnetic Field multiplied by 2!!!

Flowtube development in cooperation with PTB

Rectangular cross-section PTB report: Calculations on flow profile behaviour demonstrate: WATERFLUX has a superior uniform flow profile, also with disturbances Ideal / Reference conditions (during calibration) - Full bore meter (a) Increasing in flow velocity from wall to the centre - WATERFLUX (b) Uniform flow velocity over pipe cross section Disturbed flow (elbow before & after meter) - Full bore meter (c) Large differences in flow profile distribution - WATERFLUX (d) Almost flat flow profile. Reacts 5 times better than full bore meter a c b d 10 WATERFLUX 3070 - Introduction 2010-08-01

Placeholder for Details square section

0D inlet, 0D outlet Test results Meter under test: WATERFLUX 3070 C DN50: Measurement results of meter in 3 configurations compared to results of a master meter 1. Without disturbances 2. With 2pcs. 90 bends before & after sensor; sensor in horizontal position 3. With 2pcs. 90 bends before & after sensor; sensor tilted Results Flow variations: 1 m3/h (0.14m/s) to 57 m3/h (8m/s) < 0.2%! Straight in-/outlet lengths can be reduced to 0 DN

Engineering & Installation (1) Lay-out Mechanical meters WATERFLUX 3070 Diameter Woltman Compound DN50-DN300/500 2"- 2 /20 DN50 - DN200 2" - 8 Inlet 10D to 20D 0D Outlet 3D to 5D 0D Filter Yes, recommended No Strainer Yes, in case of insufficient inlet No DN25 - DN600 1" - 24"

2 Optimal flow tube Moulded metal construction Predictable temperature and pressure behavior. Low Cost production Highly repetitive form ( Repetitive results) Integrated mechanics features for free (Electrodes, fixtures) No machining Same concept from DN25 up to DN200

3 Adapted water contacting materials Specifications: Green Easy low cost and robust coating process on curved surfaces Worldwide Potable Water approvals High abrasion resistance High corrosion resistance (Especially for water industry and seawater) Worldwide references in water industry

Rilsan Green

Rilsan coating

4 Optimized magnetic system Magnetic calculations: High density magnetic material Low coil currents adapted to best performance of battery High N of windings Simple robust connections, a no-stress design Ultra Compact coil design (Photo next page) Avoid useless Magnetic flux (Outer shells)

Rectangular Magmeter Typical field applications

Under ground installation Simple underground installation of meter can replace building of manholes Costs of made-to-measure manholes Engineering Planning Drawings Soil report Construction Site set-up Excavation & disposal Dewatering Investments (Prefabricated) Shaft Emergency bypass + valve

WATERFLUX 3070 for District Metering Features & Benefits High accuracy at low flow rates during nights High turndown ratio (1 : >400) Excellent repeatability for comparing usage patterns during nights High reliability, nothing to break down, no wear No straight length required (0D inlet / 0D outlet) Sensor can be buried Submersible (IP68) Battery powered Minimal pressure drop Easy data collection with KGA 42

WATERFLUX 3070 for Revenue metering / Billing Features & Benefits Reliable measurement data Large turndown ratio (1:400) for high accuracies day & night Not sensitive to flow disturbances or installation conditions Certified to MID MI-001 & OIML R49 Option: Verification to MID MI-001 0 D inlet, 0D outlet Bi-directional, installation in any position Option: threat end connection for small sizes Battery powered, savings on power & cabling No pressure loss No scaling

WATERFLUX 3070 Remote Distribution Stations Solution: WATERFLUX 3070 2 x DN 150, 1 x DN 200 Battery power Large turndown ratio (1:400) Measuring error: < 0.5 % of MV (also @ flow rates of <10m3/h) 0D inlet, 0D outlet Bi-directional Reference electrode No separate grounding IP 68 (sensor)

Rectangular Magmeters Questions? 26 WATERFLUX - Comparisonon COO 2010-08-17