COMITÉ EUROPÉEN DES ASSURANCES



Similar documents
CO 2. fire extinguishing systems

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Conventional Fire Detection and Extinguishant Control System Specification

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM RECORD OF COMPLETION

KEMPER Leak Detection System

GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS. Argotec Liquid Argon Gas Extinguishing Technology (LAR)

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

COMITÉ EUROPÉEN DES ASSURANCES

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

BRANCH SOLUTION. Fire protection for wind turbines. Safe for certain

Module 4, Lesson 12 Fire Alarm Systems

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Module 5. Fire and Emergency Alarm System Part I- Basics

OZW30. Central Unit SYNERGYR

COMITÉ EUROPÉEN DES ASSURANCES

COMITÉ EUROPÉEN DES ASSURANCES

Performance Specification for Pedestrian Facilities at Temporary Standalone Traffic Signals

EXHIBIT A SCOPE OF WORK

Control and Indicating Equipment

Alarm and Detection/Suppression

BERMAD Fire Protection

RRV934. Multi-controller. Synco living

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Safety Requirements Specification Guideline

Remote Monitoring and Control of Traffic Control Equipment via a Telecommunications Network

BERMAD Fire Protection

SELECTION, APPLICATION AND MAINTENANCE

CEA Base requirements for Installers of Automatic Fire Detection and Alarm Systems (AFDS), Intruder Alarm Systems (IAS) and/or CCTV-Systems

IMO. 8 June 1998 *** I:\CIRC\MSC\848.WPD INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

ECHM Recommendations for Safety in multiplace medical hyperbaric chambers

Drayton Digistat +2RF/+3RF

Diesel Engine Driven Generators Page 1 of 6

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

NATIONAL FIRE ALARM AND SIGNALING CODE

Thyristor-controlled power supplies and battery chargers

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Fire suppression system for engine compartments USER MANUAL

MARULENG LOCAL MUNICIPALITY

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Heating Controller. Building Technologies HVAC Products

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

Ammonia Detection System Codes and Design Specifications

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

Australian Standard. Intruder alarm systems. Part 1: Systems installed in client s premises AS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ŠkodaOctavia Supplement - for vehicles with LPG drive

City of Bettendorf Fire Alarm System Requirements

Utility Distribution Systems

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

SECURIT 800L+ CONTROL PANEL

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

BACK PRESSURE MONITOR Operator Display with Exhaust Temperature KIT

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

VR8. User Guide Intruder Alarm System

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

Fire alarm system EBL512 G3

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

FIRE-FIGHTING DESIGN BRIEF REPORT

Heating and Hot Water Services Controls General Technical Specification

BS5839 Part 1:2002 Overview

R.C.C.B. s two-pole LEXIC

PROFIBUS fault finding and health checking

PLAN REVIEW GUIDE FOR FIRE ALARM

Programming Logic controllers

Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

Understanding Emergency Power Off (EPO)

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)


Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

RAD-SYS-NEMA4X-SMS Control Cabinet. Solution guide for SMS-based remote access control and intrusion detection system

HERNANDO COUNTY FIRE ALARM GUIDELINES

Bold items are particular to the City of Euless

ETZGAR CONVEYOR COMPANY Controls Section v12.05

conventional system operation

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

COMITÉ EUROPÉEN DES ASSURANCES

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.


Operational Overview and Controls Guide

A/C-HEATER SYSTEM - AUTOMATIC

Transcription:

COMITÉ EUROPÉEN DES ASSURANCES SECRETARIAT GENERAL 3bis, rue de la Chaussée d'antin F 75009 Paris Tél. : +33 1 44 83 11 73 Fax : +33 1 44 83 11 85 Web : cea.assur.org DELEGATION A BRUXELLES Square de Meeûs, 29 B 1000 Bruxelles Tél. : +32 2 547 58 11 Fax : +32 2 547 58 19 Web : cea.assur.org PROPERTY INSURANCE COMMITTEE Prevention Specifications Monitoring of CO2 Systems CEA 4019: May 1998 (en) (EFSAC endorsed) Copyright by CEA 3 bis, rue de la Chaussée d Antin 75009 PARIS

Monitoring of CO2 Systems 1. General CO 2 systems shall be automatically monitored for their availability in the case of: low-pressure systems, high-pressure systems with more than 500 kg supply quantity (not including the reserve quantity), high-pressure systems with more than 250 kg supply quantity (not including the reserve quantity) where a delay time is required for life safety aspects, 1 Components shall be monitored continuously for their availability, if their failing or a wrong operating position can prevent the emission of the extinguishing medium or the functioning of the alarm and delay device in case of triggering, or if it can cause an emission into a not-triggered extinguishing zone. Testing of the monitoring system must always be possible. The monitoring system shall not affect the correct function of the CO 2 system. 2. Low-pressure systems 2.1 Valves, disable and control devices The correct operating position of the following components shall be monitored: valves installed in the extinguishant flow, such as isolating valves and selector valves, manually operated valves which are not located in the extinguishant flow, but which can jeopardise the function of the installation, as valves in pneumatic pilot lines, etc., disable devices, non-electrical control devices. 2.2 Quantity of extinguishing medium The quantity of available extinguishant shall be monitored. Any loss of more than 10 % of the content of any container shall be indicated. 1 There may be aspects of value of the protected risks like consequential losses which needs to be considered. 2

2.3 Pressure Deviations from the regular working pressure of the following components shall be monitored: low-pressure CO 2 container (minimum pressure 18 bars, maximum pressure 22 bars), pneumatic detection pipework which is constantly under pressure (not necessary if the correct operating position of a valve upstream of the device is monitored). 3. High-pressure systems 3.1 Disable and triggering devices and selector valves The correct operating position of the following components shall be monitored: Non-electrical control devices, Disable devices, Selector valves, Switch devices for main/ reserve supply container, In the case of mechanical control using wire cables: the position of the triggering device. 3.2 Quantity of extinguishing medium and pilot gas The quantity of available extinguishant and pilot gas shall be monitored. Any loss of more than 10 % of the content of any container shall be indicated : all containers of the main supply and of the reserve supply permanently connected to the pipe system, containers for the supply of the alarm devices and /or pilot containers. 4. Electrical lines Electrical lines transmitting alarm and fault signals or signals for the monitoring and control of the installation and alarm devices (monitored first alarm with two independent energy supplies) shall be monitored for line break, short circuit and earth fault. The CEA specifications for fire detection installations shall be taken into account. Necessary additional controlling signals (e.g. shut-off of ventilation systems, closing or opening of the enclosure) may be transmitted by non-monitored lines. 3

5. Electrically operated components The power supply of electrically-operated components of CO 2 installation shall be monitored for normal condition and power failure as far as they cannot be monitored by the fire detection installation. 6. Monitoring and control lines 6.1 Monitoring lines Each monitoring device shall have a separate indicator. A maximum of 60 monitoring devices may be connected to one detection line. 6.2 Monitoring lines for disable devices The actuation of the disable device shall be transmitted and indicated separately. A maximum of 20 monitoring devices for disable devices may be connected to one line. The disabled condition of the system shall not cause a fault indication but the disabled condition of the system shall be indicated separately. 6.3 Control lines All electrically-controlled components for the release of the installation, operation of selector valves, delay devices and alarm devices shall be connected to lines monitored for line break, short circuit and earth fault. The devices shall be attached to the control lines so that in the case of a fault indication an unequivocal and quick identification of the components of the installation causing this fault indication is possible. This is relevant for: Triggering devices of pilot containers, container batteries, isolating valves and selector valves, electromagnetic locking devices for triggering devices and/or selector valves and solenoid valves for controlling the CO 2 stop device and / or secondary flooding function. 7. Storage area The CO 2 storage area shall be monitored for the allowable maximum and minimum ambient temperature in the case of high-pressure systems and for the allowable maximum temperature in the case of low-pressure systems where a dedicated heating or cooling system is installed. 4

8. Fault indication 8.1 Indication and transmission Faults of the CO 2 installation shall be indicated visually and audibly at a location on the premises, which is continuously manned. It must be possible to switch off the audible signal, but the visual signal may only be switched off if the fault is removed. If the plant does not have a continuously manned location, the fault indication shall be transmitted automatically to an employee in the plant (e.g. by the help of a telephone transmitter). 8.2 Further indications The fault indication of the following shall be indicated separately: monitoring system of the CO 2 system other monitoring systems fire detection system control devices. Faults in CO 2 installation and faults in the monitoring installation shall be indicated separately. As long as a fire detection signal on the CO 2 installation is present, no fault detection shall be indicated at the monitoring control panel or at the monitoring insertion of the c.i.e. of the fire detection installation. 9. Power supply of the monitoring installation The power supply of the monitoring installation shall be installed accordingly to the CEA specifications for fire detection installations. 10. Requirements for components of the monitoring installation 10.1 Protection class The components of the monitoring installation shall at least meet the protection class IP 54 (IEC 529 - Degrees of protection provided by enclosures - IP code). 10.2 Switching way In case of valves the fault indications shall depend on the moving way of the component under monitoring. The switching way is the way from the just still closed to the totally opened position of the valve. 5

10.3 Switching way of normally open devices The fault indication for valves which are situated in the extinguishant flow and in the pneumatic pilot lines, and the fault indication for other blocking devices which are continuously opened when the CO 2 installation is ready for service, shall be activated at the latest when the components are closed 20% of the switching way. 10.4 Switching way of normally closed devices In case of valves in the extinguishant flow and in case of valves which are not situated directly in the extinguishant flow and which are closed when the CO 2 installation is ready for service, the fault indication shall be activated immediately when the opening procedure starts. 10.5 Blocking devices of alarm devices, pressure or pneumatic switches In case of blocking devices of alarm devices and pressure or pneumatic switches, the fault indication shall be effective already in intermediate positions. 10.6 Non-electrical control devices Non-electrical control devices shall be monitored. The requirement is fulfilled if the room with the non-electrical control device is only accessible to authorised persons and if opening the door causes a fault indication. Components may not be monitored if they are automatically reset into their operating position by the triggering energy of the installation itself. 6