City of Dallas 1.5 MGD WWTP



Similar documents
ANAEROBIC/ANOXIC TANKS

Equipment and Instrument Tagging Requirements

Trouble Shooting Guide

POSITIVE DISPLACEMENT BLOWERS & VACUUM PUMPS. Water & Wastewater Treatment Solutions

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Description of the Water Conserv II Facility

WATER/WASTEWATER: ACHIEVING THE THREE LEVELS OF REDUNDANCY

Phosphorus Removal. Wastewater Treatment

Aeration Efficiency Guide

Operation & Maintenance Manual SYSTEM NAME

Prime Power Services, Inc. Georgia, Carolinas NFPA 110 Standards for Emergency & Stand by Generators June 1, 2010

William E. Dunn Water Reclamation Facility. Facility Overview & Information

Small Wastewater Treatment Systems

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

Advanced Wastewater Treatment and Disposal Systems. Water and Wastewater Utility Operation and

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Holistic Aeration and Chemical Optimization Saves Big Money from 1 MGD to 600 MGD. Trevor Ghylin, PE PhD

Cat Electronic Technician 2015C v1.0 Product Status Report 2/20/2016 4:34 PM

Diesel Engine Driven Generators Page 1 of 6

Diagnostic Fault Codes For Cummins Engines

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Advanced_O&M_Task_List_Example_Tool_06_02_16: O&M Example

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

SMS GSM Alarm Messenger

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

PANASONIC TROUBLE SHOOTING GUIDE

ngenieros Ingenieros Asociados De Control S.L.

Raptor Septage Acceptance Plant. For Municipal Wastewater, Septage and Grease Trap Applications

Ann Arbor Wastewater Treatment Plant Facilities Renovations Project September 2015

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

Manual. MegaTron Controller Supplemental. Modbus / TCP Communications Manual

Control and Remote Supervision of Sewage Pump Station. AutoLog GSM-RTU and AutoLog ControlMan Web-SCADA Service. Specification V1.

Operational Overview and Controls Guide

Cooling Channel Optimization

DC-8706K Auto Dial Alarm System

OPTIMIZING BIOLOGICAL PHOSPHORUS REMOVAL FROM AN SBR SYSTEM MIDDLEBURY, VT. Paul Klebs, Senior Applications Engineer Aqua-Aerobic Systems, Inc.

FIRE ALARM SYSTEM RECORD OF COMPLETION

MWEA Infrastructure Project Funding

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

FIRE ALARM SYSTEM RECORD OF COMPLETION

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

MIDNITE SOLAR AND SOLAR WASHINGTON

May, ArACBMENT I. Review of. Diesel Generator Alan and Control Circuitry. Indian Point Units No. 2 and 3. Docket Nos.

OPERATIONS & MAINTENANCE FY Adopted Budget

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

FIREDEX Conventional Fire Panels

MODELING WASTEWATER AERATION SYSTEMS TO DISCOVER ENERGY SAVINGS OPPORTUNITIES By Steven A. Bolles Process Energy Services, LLC

OZW30. Central Unit SYNERGYR

Temperature & Humidity SMS Alert Controller

Inova SV125 Machine Number

BODY ELECTRICAL TOYOTA ELECTRICAL WIRING DIAGRAM WORKBOOK. ASSIGNMENT Version 1.8 WORKSHEETS.

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Water Priming Mode Purge air from plumbing system. How do I solve ER-3 WATER PRIME: TIPS ON FILLING SPA IMPORTANT NOTE WARNING

Bay Park Sewage Treatment Plant Super Storm Sandy Recovery

S4000TH HART. HART Communication Manual

Nutrient Removal at Wastewater Treatment Facilities. Nitrogen and Phosphorus. Gary M. Grey HydroQual, Inc X 7167

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

THE MARSHALL STREET ADVANCED POLLUTION CONTROL FACILITY (CLEARWATER, FLORIDA) CONVERSION TO 4-STAGE BARDENPHO TO IMPROVE BIOLOGICAL NITROGEN REMOVAL

Features and Benefits

Project Test Plans Preparation Guide. Advanced Wastewater Treatment Plant. Version 1.0

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

1. EXTERNAL ALARM MESSAGE

Specifying a Variable Frequency Drive s

Cambridge Wastewater Treatment Facility

Heating Controller. Building Technologies HVAC Products

2.24. Pump Controller 704. Data Sheet

MUNICIPAL WASTEWATER TREATMENT PLANT ENERGY EVALUATION FOR ITHACA AREA WASTEWATER TREATMENT FACILITY

Contact ID Codes. UNDEFINED DSC CONTACT ID CODE 104 RESTORE Zone Test/Misc. DSC CID RESTORE. 103 TECHNICIAN Unknown Test/Misc.

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

MAJORSINE Power Inverter

Recovery Boiler Combustion control system(ccs) & Emergency shutdown(esd).

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Rev 0 25-AUG ipro HVAC and Lighting Installation and Operation Manual

SCADA and Monitoring for Solar Energy Plant

Northport/Leelanau Township Wastewater Treatment Facility

Study on the Auto Air Conditioning Controller Testing System Based on Lab Windows/CVI

CB200W Water Leak Detection Panel Application Guide

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

SNMP Web Management. User s Manual For SNMP Web Card/Box

Spark-ignited generator set

Module 16: The Activated Sludge Process - Part II Instructor Guide Answer Key

Oil and Coolant Circulating Heating System. Model - OCSM

Electronic faucets for every occasion, every application

EDI Distributor Control Interface Wiring and Setup Instructions

Process and Energy Audits at Water and Wastewater Facilities. Thomas Devine, CAP, CEM, LEED AP April

NAYADIC TROUBLE-SHOOTING CHECKLIST

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

5. TREATMENT FACILITIES

Transfer Equipment Controls

Transcription:

LCP NO. EQUIPMENT DESCRIPTION SIGNAL OPERATOR NOTE REV NO TYPE INTERFACE DATE SCADA LCP1 LE751 EXISTING DIGESTER LEVEL AI I, R, C SCADA LCP1 FIT548 RAS FLOW RATE AI I, R, C SCADA LCP1 FIT549 WAS FLOW RATE AI I, R, C SCADA LCP1 AIT402 AERATION BASIN TRAIN 1 SUSPENDED SOLIDS AI I, R, C SCADA LCP1 AIT404 AERATION BASIN TRAIN 2 SUSPENDED SOLIDS AI I, R, C SCADA LCP1 LCP400 ANAEROBIC MIXER NO. 1 (MX 301) RUNNING ETHERNET I SCADA LCP1 LCP400 ANAEROBIC MIXER NO. 1 (MX 301) FAULT ETHERNET I SCADA LCP1 LCP400 ANAEROBIC MIXER NO. 1 (MX 301) HIGH TEMP ETHERNET I SCADA LCP1 LCP400 ANAEROBIC MIXER NO. 1 (MX 301) LEAK ETHERNET I SCADA LCP1 LCP400 ANAEROBIC MIXER NO. 2 (MX 302) RUNNING ETHERNET I SCADA LCP1 LCP400 ANAEROBIC MIXER NO. 2 (MX 302) FAULT ETHERNET I SCADA LCP1 LCP400 ANAEROBIC MIXER NO. 2 (MX 302) HIGH TEMP ETHERNET I SCADA LCP1 LCP400 ANAEROBIC MIXER NO. 2 (MX 302) LEAK ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 1 (MX 401) RUNNING ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 1 (MX 401) FAULT ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 1 (MX 401) HIGH TEMP ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 1 (MX 401) LEAK ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 2 (MX 402) RUNNING ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 2 (MX 402) FAULT ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 2 (MX 402) HIGH TEMP ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 2 (MX 402) LEAK ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 3 (MX 403) RUNNING ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 3 (MX 403) FAULT ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 3 (MX 403) HIGH TEMP ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 3 (MX 403) LEAK ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO.4 (MX 404) RUNNING ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 4 (MX 404) FAULT ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 4 (MX 404) HIGH TEMP ETHERNET I SCADA LCP1 LCP400 ANOXIC MIXER NO. 4 (MX 404) LEAK ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 1 (A 401) RUNNING ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 1 VFD401 FAULT ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 1 (A 401) HIGH TEMP ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 1 (A 401) LOW OIL PRESSURE ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 1 (A 401) LCP401 IN AUTO ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 1 VFD401 IN AUTO ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 1 VFD401 SPEED ETHERNET I, R SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 1 VFD401 CURRENT ETHERNET I, R SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 2 (A 402) RUNNING ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 2 VFD402 FAULT ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 2 (A 402) HIGH TEMP ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 2 (A 402) LOW OIL PRESSURE ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 2 (A 402) LCP402 IN AUTO ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 2 VFD402 IN AUTO ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 2 VFD402 SPEED ETHERNET I, R SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 2 VFD402 CURRENT ETHERNET I, R SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 3 (A 403) RUNNING ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 3 VFD403 FAULT ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 3 (A 403) HIGH TEMP ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 3 (A 403) LOW OIL PRESSURE ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 3 (A 403) LCP403 IN AUTO ETHERNET I

SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 3 VFD403 IN AUTO ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 3 VFD 403 SPEED ETHERNET I, R SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 3 VFD 403 CURRENT ETHERNET I, R SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 4 (A 404) RUNNING ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 4 VFD404 FAULT ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 4 (A 404) HIGH TEMP ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 4 (A 404) LOW OIL PRESSURE ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 4 (A 404) LCP404 IN AUTO ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 4 VFD404 IN AUTO ETHERNET I SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 4 VFD 404 SPEED ETHERNET I, R SCADA LCP1 LCP400 AEROBIC ZONE AERATOR NO. 4 VFD 404 CURRENT ETHERNET I, R SCADA LCP1 LCP400 AERATION BASIN TRAIN 1 DISSOLVED OXYGEN (AIT 401) ETHERNET I, R SCADA LCP1 LCP400 AERATION BASIN TRAIN 1 TEMPERATURE (AIT 401) ETHERNET I, R SCADA LCP1 LCP400 AERATION BASIN TRAIN 2 DISSOLVED OXYGEN (AIT 403) ETHERNET I, R SCADA LCP1 LCP400 AERATION BASIN TRAIN 2 TEMPERATURE (AIT 403) ETHERNET I, R SCADA LCP1 LCP 210 SEPTAGE RECEIVING STATION SYSTEM READY DI I SCADA LCP1 LCP 210 SEPTAGE RECEIVING STATION SYSTEM FAULT DI I SCADA LCP1 LCP 210 SEPTAGE RECEIVING STATION FLOW DI I SCADA LCP1 LCP 210 SEPTAGE RECEIVING STATION LOCK OUT DO C SCADA LCP1 LCP 210 SEPTAGE RECEIVING STATION RECORDER RS 485 I SCADA LCP1 LCP 210 SEPTAGE RECEIVING STATION GRINDER RUNNING DI I SCADA LCP1 LCP 210 SEPTAGE RECEIVING STATION GRINDER FAULT DI I SCADA LCP1 LCP 210 SEPTAGE RECEIVING STATION CONVEYOR RUNNING DI I SCADA LCP1 LCP 210 SEPTAGE RECEIVING STATION CONVEYOR FAULT DI I SCADA LCP1 MCC A CLARIFIER #1 CL521 RUNNING DI I SCADA LCP1 LCP 521 CLARIFIER #1 CL521 HIGH TORQUE DI I SCADA LCP1 LCP 521 CLARIFIER #1 CL521 DRIVE CUTOUT DI I SCADA LCP1 MCC A CLARIFIER #2 CL52 RUNNING DI I SCADA LCP1 LCP 522 CLARIFIER #2 CL522 HIGH TORQUE DI I SCADA LCP1 LCP 522 CLARIFIER #2 CL522 DRIVE CUTOUT DI I SCADA LCP1 VFD 541 WAS VFD AUTO POSITION DI I SCADA LCP1 VFD 541 WAS VFD RUNNING DI I SCADA LCP1 VFD 541 WAS VFD CALL TO RUN DO C SCADA LCP1 VFD 541 WAS VFD FAULT DI I SCADA LCP1 VFD 541 WAS VFD SPEED CONTROL AO I, C SCADA LCP1 VFD 541 WAS VFD CURRENT AI I, R SCADA LCP1 VFD 541 WAS VFD SPEED REFERENCE AI I, R SCADA LCP1 VFD 542 WAS/RAS VFD AUTO POSITION DI I SCADA LCP1 VFD 542 WAS/RAS VFD RUNNING DI I SCADA LCP1 VFD 542 WAS/RAS VFD CALL TO RUN DO C SCADA LCP1 VFD 542 WAS/RAS VFD FAULT DI I SCADA LCP1 VFD 542 WAS/RAS VFD SPEED CONTROL AO I, C SCADA LCP1 VFD 542 WAS/RAS VFD CURRENT AI I, R SCADA LCP1 VFD 542 WAS/RAS VFD SPEED REFERENCE AI I, R SCADA LCP1 VFD 543 RAS VFD AUTO POSITION DI I SCADA LCP1 VFD 543 RAS VFD RUNNING DI I SCADA LCP1 VFD 543 RAS VFD CALL TO RUN DO C SCADA LCP1 VFD 543 RAS VFD FAULT DI I SCADA LCP1 VFD 543 RAS VFD SPEED CONTROL AO I, C SCADA LCP1 VFD 543 RAS VFD CURRENT AI I, R

SCADA LCP1 VFD 543 RAS VFD SPEED REFERENCE AI I, R SCADA LCP1 HS 541 HS 541 PUMP REMOTE POSITION DI I, C SCADA LCP1 HS 541 HS 541 PUMP HAND POSITION DI I, C SCADA LCP1 HS 541 HS 541 SOLENOID AUTO POSITION DI I, C SCADA LCP1 HS 541 HS 541 SOLENOID OPEN POSITION DI I, C SCADA LCP1 SV 541 CALL TO ENERGIZE (120V) DO I, C SCADA LCP1 FS 541 SEAL WATER FLOWING DI I, C SCADA LCP1 HS 542 HS 542 PUMP REMOTE POSITION DI I, C SCADA LCP1 HS 542 HS 542 PUMP HAND POSITION DI I, C SCADA LCP1 HS 542 HS 542 SOLENOID AUTO POSITION DI I, C SCADA LCP1 HS 542 HS 542 SOLENOID OPEN POSITION DI I, C SCADA LCP1 SV 542 CALL TO ENERGIZE (120V) DO I, C SCADA LCP1 FS 542 SEAL WATER FLOWING DI I, C SCADA LCP1 HS 543 HS 543 PUMP REMOTE POSITION DI I, C SCADA LCP1 HS 543 HS 543 PUMP HAND POSITION DI I, C SCADA LCP1 HS 543 HS 543 SOLENOID AUTO POSITION DI I, C SCADA LCP1 HS 543 HS 543 SOLENOID OPEN POSITION DI I, C SCADA LCP1 SV 543 CALL TO ENERGIZE (120V) DO I, C SCADA LCP1 FS 543 SEAL WATER FLOWING DI I, C SCADA LCP1 LCP040 PLANT SCUMP PUMP P041 FAIL DI I SCADA LCP1 LCP040 PLANT SCUMP PUMP P041 RUN DI I SCADA LCP1 LCP040 PLANT SCUMP PUMP P042 FAIL DI I SCADA LCP1 LCP040 PLANT SCUMP PUMP P042 RUN DI I SCADA LCP1 LCP040 PLANT SCUMP PUMP STATION COMMON ALARM DI I SCADA LCP1 LCP040 PLANT SCUMP PUMP STATION HIGH HIGH LEVEL ALARM DI I SCADA LCP1 M 545 RAS VALVE CALL TO OPEN DO I, C SCADA LCP1 M 545 RAS VALVE CALL TO CLOSE DO I, C SCADA LCP1 M 545 RAS VALVE 100% OPEN DI I SCADA LCP1 M 545 RAS VALVE 100% CLOSED DI I SCADA LCP1 M 545 RAS VALVE REMOTE POSITION DI I SCADA LCP1 M 546 WAS VALVE CALL TO OPEN DO I, C SCADA LCP1 M 546 WAS VALVE CALL TO CLOSE DO I, C SCADA LCP1 M 546 WAS VALVE 100% OPEN DI I SCADA LCP1 M 546 WAS VALVE 100% CLOSED DI I SCADA LCP1 M 546 WAS VALVE REMOTE POSITION DI I SCADA LCP1 SWBD SWBD METER POWER ETHERNET I, R SCADA LCP1 SWBD SWBD METER POWER FACTOR ETHERNET I, R SCADA LCP1 SWBD SWBD METER VOLTAGE / PHASE 1 ETHERNET I, R SCADA LCP1 SWBD SWBD METER VOLTAGE / PHASE 2 ETHERNET I, R SCADA LCP1 SWBD SWBD METER VOLTAGE / PHASE 3 ETHERNET I, R SCADA LCP1 SWBD SWBD METER CURRRENT / PHASE 1 ETHERNET I, R SCADA LCP1 SWBD SWBD METER CURRENT / PHASE 2 ETHERNET I, R SCADA LCP1 SWBD SWBD METER CURRENT / PHASE 3 ETHERNET I, R SCADA LCP1 SWBD SWBD METER THD ETHERNET I, R SCADA LCP1 SWBD SWBD METER PF ETHERNET I, R SCADA LCP1 SWBD SWBD METER ALARM ETHERNET I SCADA LCP1 ATS AUTOMATIC TRANSFER SWITCH NORMAL POSITION DI I SCADA LCP1 ATS AUTOMATIC TRANSFER SWITCH EMERGENCY POSITION DI I SCADA LCP1 ATS AUTOMATIC TRANSFER SWITCH OPEN POSITION DI I SCADA LCP1 GENERATOR GENERATOR RUNNING DI I SCADA LCP1 GENERATOR GENERATOR FAULT DI I

SCADA LCP1 GENERATOR GENERATOR FUEL LEAK DI I SCADA LCP1 GENERATOR GENERATOR PRE LOW OIL PRESSURE RS 485 I SCADA LCP1 GENERATOR GENERATOR PRE HIGH WATER TEMP RS 485 I SCADA LCP1 GENERATOR GENERATOR PRE LOW WATER TEMP RS 485 I SCADA LCP1 GENERATOR GENERATOR PRE LOW FUEL RS 485 I SCADA LCP1 GENERATOR GENERATOR BATTERY CHARGER AC FAIL RS 485 I SCADA LCP1 GENERATOR GENERATOR LOW BATTERY VOLTAGE RS 485 I SCADA LCP1 GENERATOR GENERATOR HIGH BATTERY VOLTAGE RS 485 I SCADA LCP1 GENERATOR GENERATOR NOT IN AUTO RS 485 I SCADA LCP1 GENERATOR GENERATOR PM SENSOR LOSS RS 485 I SCADA LCP1 GENERATOR GENERATOR OVERCRANK RS 485 I SCADA LCP1 GENERATOR GENERATOR OVER SPEED RS 485 I SCADA LCP1 GENERATOR GENERATOR LOW OIL PRESSURE RS 485 I SCADA LCP1 GENERATOR GENERATOR HI WATER TEMP RS 485 I SCADA LCP1 GENERATOR GENERATOR LO WATER LEVEL RS 485 I SCADA LCP1 GENERATOR GENERATOR EMERGENCY STOP RS 485 I SCADA LCP1 GENERATOR GENERATOR RUNNING RS 485 I SCADA LCP1 GENERATOR GENERATOR POWER (ATS) RS 485 I SCADA LCP1 GENERATOR GENERATOR LINE POWER (ATS) RS 485 I SCADA LCP1 GENERATOR GENERATOR SYSTEMS READY RS 485 I SCADA LCP1 GENERATOR GENERATOR COMMUNICATIONS OK RS 485 I SCADA LCP1 AIT 521 CLARIFIER #1 SLUDGE BLANKE T LEVEL AI I, R SCADA LCP1 AIT 521 CLARIFIER #1 SLUDGE FLUFF LEVEL AI I, R SCADA LCP1 AIT 522 CLARIFIER #2 SLUDGE BLANKE T LEVEL AI I, R SCADA LCP1 AIT 522 CLARIFIER #2 SLUDGE FLUFF LEVEL AI I, R SCADA LCP1 AIT 531A CLARIFIER #1 SUSPENDED SOLIDS AI I, R SCADA LCP1 AIT 531B CLARIFIER #2 SUSPENDED SOLIDS AI I, R SCADA LCP1 MCC A DIGESTER BLOWER 1 RUNNING DI I SCADA LCP1 MCC A DIGESTER BLOWER 1 FAULT DI I SCADA LCP1 MCC A DIGESTER BLOWER 1 CALL TO RUN DO I, C SCADA LCP1 MCC A DIGESTER BLOWER 1 REMOTE MODE DI I SCADA LCP1 HS 761 HS 761 IN REMOTE POSITION DI I SCADA LCP1 MCC A DIGESTER BLOWER 2 RUNNING DI I SCADA LCP1 MCC A DIGESTER BLOWER 2 FAULT DI I SCADA LCP1 MCC A DIGESTER BLOWER 2 CALL TO RUN DO I, C SCADA LCP1 MCC A DIGESTER BLOWER 2 REMOTE MODE DI I SCADA LCP1 HS 762 HS 762 IN REMOTE POSITION DI I SCADA LCP1 FIT 940 PLANT DRAIN FLOW RATE AI I, R, C SCADA LCP1 LCP161 SCREEN RUNNING DI I SCADA LCP1 LCP161 SCREEN FAIL DI I SCADA LCP1 LCP161 SCREEN EMERGENCY STOP DI I SCADA LCP1 LCP161 SCREEN DOOR OPEN DI I SCADA LCP1 LCP161 AUTO POSITION DI I SCADA LCP1 LCP161 HIGH LEVEL DI I SCADA LCP1 LCP162 CONVEYOR RUNNING DI I SCADA LCP1 LCP162 CONVEYOR FAIL DI I SCADA LCP1 LCP162 AUTO POSITION DI I SCADA LCP1 LCP162 CONVEYOR EMERGENCY STOP DI I SCADA LCP1 LCP170 GRIT PADDLE DRIVE RUNNING DI I SCADA LCP1 LCP170 GRIT PADDLE DRIVE FAULT DI I

SCADA LCP1 LCP170 GRIT PUMP RUNNING DI I SCADA LCP1 LCP170 GRIT PUMP FAULT DI I SCADA LCP1 LCP170 GRIT SCREW CONVEYOR RUNNING DI I SCADA LCP1 LCP170 GRIT SCREW CONVEYOR FAULT DI I SCADA LCP1 LCP170 GRIT SYSTEM E STOP DI I SCADA LCP1 LCP170 GRIT SYSTEM PRIMING FAIL DI I SCADA LCP1 LCP170 GRIT CONVEYOR MOTION FAIL DI I SCADA LCP1 LCP170 GRIT SYSTEM AUTO POSITION DI I SCADA LCP1 LSHH 161 SCREEN INFLUENT CHANNEL HIGH HIGH LEVEL DI I SCADA LCP1 FIT 101 INFLUENT FLOW METER AI I,R,C SCADA LCP1 INF. SAMPLER FLOW RATE TO INFLUENT SAMPLER AO I, C SCADA LCP1 INF. SAMPLER INFLUENT SAMPLER SAMPLE DO I, C SCADA LCP1 INF. SAMPLER INFLUENT SAMPLER ALARM DI I SCADA LCP1 EX. DIG PV #1 EXISTING DIGESTER PLUG VALVE #1 CALL TO OPEN DO C SCADA LCP1 EX. DIG PV #1 EXISTING DIGESTER PLUG VALVE #1 CALL TO CLOSE DO C SCADA LCP1 EX. DIG PV #1 EXISTING DIGESTER PLUG VALVE #1 100% OPEN DI I SCADA LCP1 EX. DIG PV #1 EXISTING DIGESTER PLUG VALVE #1 100% CLOSED DI I SCADA LCP1 EX. DIG PV #1 EXISTING DIGESTER PLUG VALVE #1 REMOTE POSITION DI I SCADA LCP1 EX. DIG PV #2 EXISTING DIGESTER PLUG VALVE #2 CALL TO OPEN DO C SCADA LCP1 EX. DIG PV #2 EXISTING DIGESTER PLUG VALVE #2 CALL TO CLOSE DO C SCADA LCP1 EX. DIG PV #2 EXISTING DIGESTER PLUG VALVE #2 100% OPEN DI I SCADA LCP1 EX. DIG PV #2 EXISTING DIGESTER PLUG VALVE #2 100% CLOSED DI I SCADA LCP1 EX. DIG PV #2 EXISTING DIGESTER PLUG VALVE #2 REMOTE POSITION DI I SCADA LCP1 LTG CTR LIGHTING CONTACTOR ACTIVATE DO I, C