1 . EXTERAL ALARM MESSAGE 00 SAFET DOOR EED CLOSE! ALARM 00 Is the safety door closed? Close the safety door. Is the window closed? Close the window. The diagnostic X8.=0. The limit switch (-A27) for the safety door or the window detects incorrectly. Please adjust it. 2. The limit switch (-A27) for the safety door or the window is defective. Please replace it. Press the RESET key. ED 8-2

2 003 SPIDLE MOTOR ALARM! ALARM 003. Please check the alarm number from C or the LED alarm number that displayed by spindle AMP. Please call for service 8-3

3 004 SPIDLE GEAR SHIFT ALARM! ALARM 004 Press the RESET button. 5 Is the machine with gear box? D57= D57=0 Consult Chap2 5.2 set. During maintenance? K4.7= Shift the gear box to HI (or LO) by execute Sxxxx. Shift to HI Shift to LO Is the gear HI solenoid valve O? (-306) Is the gear LO solenoid valve O? (-305) Is the gear HI limit switch O? DG X5.6=0 X5.5= (S-302) Is the gear HI limit switch O? DG X5.6= X5.5=0 (S-303) 4 ED 8-4

4 2 3. In HI output DG3.0= 3.=0 In LO output DG 3.= 3.0=0 6 6 Cause: Condition error. Please command S-code again. 5 Cause:. The wiring of solenoid valve is poor contact. Please check the wiring. 2. The solenoid valve is defective. Please replace it. 3. The relay is defective. Please replace it. 5 4 Cause:. The limit switch for gear HI/LO detects incorrectly. Please adjust it. 2. The limit switch is defective. Please replace it

5 005 ATC OT READ! (FOR ATC 24T 30T 32T 40T) ALARM 005 Change to the JOG mode Press the POT vertical button and release it to make the POT to the vertical position. Is the POT in the vertical position? DG 2.5= DG X6.2= X6.3= Is the Z axis at the tool change position? The diagnosis 7.0=(absolute) Keep to press manual ATC button Refer to ALM09 until cycle START button flashing. Start ATC change by press the cycle START button

6 5 Is ATC start to change? DG 2.4= Is the ATC in the position after ATC change finish? 2 3 Press the POT vertical button and release it to make the POT to the horizontal position. Is the POT in the horizontal position? Press the EMG button and release it. 6 The diagnosis X6.2=0 X6.3= DG 2.6= Press the RESET button Make sure the SPIDLE TOOL (The diagnosis D440) and EXT TOOL (The diagnosis C2) number are correct. ED 8-7

7 2 3 Cause:. The solenoid valve is defective. Please replace it. 2. The wiring of the solenoid valve is poor contact. Please check the wiring. 3. MAG locked. Please check it. 4. Parts interference. Please check it. Cause:. The button is defective. Please replace it. 2. The wiring of button is poor contact. Please check the wiring. 3. Condition error. Please reset again. 4 6 Cause: The limit switch is defective. Please replace it. The limit switch detects incorrectly. Please check it. Cause:. The limit switch for ARM detects incorrectly. Please check it. (ARM HOME X6.5, ARM BRAKE X6.4, TOOL U/CL COFIRM X6.6) 8-8

8 007 TF 0 COMMAD ERROR! ALARM 007 Wrong T command. Press the RESET key. Modify the T command 0 < T. ED 008 TF IS OTHIG I TOOL BOX! ALARM 008 Wrong T command. Press the RESET key. Correct the T command. ED 8-9

9 009 SERVO MOTOR ALARM! ALARM 009 Please close C power than open. Please check PMM MSG massage and consult Chap5 Appendix F eliminate. 00 SERVO MOTOR BATTER ALARM! ALARM 00 Please check PMM MSG massage and consult Chap5 Appendix F eliminate. ED 8-0

10 0 MAG (C0) SETTIG ERROR! ALARM 0 Press the RESET key. Set the diagnostic C0 with the total tool amount of the magazine. Consult Chap2 5.2 setting. End 02 POT (C2) SETTIG ERROR! ALARM 02 Press the RESET key. Set the diagnostic C2 with the tool no. on the standby pot. Consult Chap2 5.2 setting. End 8-

11 03 DOUBLE TOOL DETECTIO! ALARM 03 Press the RESET key. Check the standby pot no. equaling to the tool no. on the spindle. Set the correct pot no. (C2) Consult Chap2 5.2 setting. Remove the tool from the pot Try tool change M6 Txx again. Is the alarm still there? End. The sensor (S404) for tool detection is defective. Please replace it. 2. The sensor for tool detection is poor connected. Please check it. 8-2

12 04 SP. ORI ALARM! ALARM 04 Press refer to the parameter list attached with the machine to correct the C parameters o.4000~4099. Press the RESET key. Execute the M9 command of spindle orientation. Is the alarm still there? End 8-3

13 05 MOTOR OVERLOAD! ALARM 05 Please check the following motors whether there is overlod or fuse blown.. Motor of coolant pump (-F23) 2. Motor of chip conveyor (-F27, -F28) 3. Fuse on Lubricating unit (-A204) 4. Fuse on oil-air lubricating unit (-F239) 5. Motor of oil skimmer (-F234) 6. Motor of pump for coolant through spindle (-F200) 7. Motor of hydraulic unit (-F222) 8. Motor of pump for floor flushing (-F232) 9. Motor of spindle cooler (-A207) Solve the cause of overload. Press the resetting device on the overload relay Press the RESET key. End 8-4

14 06 SP. TOOL (D440) SETTIG ERROR! ALARM 06 Set the diagnostic D440 with the tool no. on the spindle. Consult Chap2 5.2 setting. Press the RESET key. End 08 M6 WITHOUT TF ALARM! ALARM 08 Modify the format of program as M6 Txx End 8-5

15 09 M6 SWAP POSITIO MISSED! ALARM 09 Press the RESET key. Is the function of automatic ATC position return used? (The unction for PMC axis) Is the spindle at the ATC position? Set diagnostic K.0= Please exectute the command of ATC position return before automatic tool change ATC. Is the servo motor incremental or absolute type? K2.2= is the incremental type. Wrong setting for the ATC position. Please refer to the following table to modify the parameter setting.. ATC position detection error, please adjust LS. (-S3) 2. ATC position LS damage please change the LS. (-S3) End 8-6

16 Roller gear type ATC Type Simple disk type Cam type of Roller gear type (Z axis for ATC Parameter (crank driving) single cycle (3 axes for ATC position ) position ) 24 X ATC position ATC position. Z ATC position X coordinate of ATC position The 2nd ATC position coordinate of ATC position The st ATC position Z coordinate of ATC position X coordinate of ATC position The 2nd ATC position coordinate of ATC position The st ATC position Z coordinate of ATC position X Z The setting value varies according to the machine model. If the machine is with ISC system, all setting values of the ATC position must be the coordinate value multiplying 0 times. 8-7

17 020 SP.COOLIG LUBRICATIG SSTEM FAILED! ALARM 020 Is the spindle with oil-air lubrication or oil cooler? Set the diagnostic K3.0=. Is there oil cooler? Is the oil cooler with enough oil? Oil level of the oil cooler is too low. Please fill oil. (-A207) Is there oil-air lubrication? Diagnostic K8.2=?.Oil-air is too much. The amount needs to be adjusted 2. Wiring of the temperature switches (-F244, -F245) is poor contact. Please check the wiring. 3. The spindle motor is out of order. Please solve the cause.. The detector for oil level of the oil cooler (-A207) detects incorrectly. Pleae check it. End 8-8

18 02 TOOL MEASURE ALARM ALARM 02 Is it overtravel during tool length measurement? 2 Under the HADLE mode, move the spindle apart from the probe. Press lightly the detecting switch of the prober to get the red lamp lighting on. Diagnostic X7.4=0?. The cable for the element of the probe is poor connection or broken. Please check and replace the cable. 2. Some element of the probe (-A206) is defective, please replace the probe. Press lightly the detecting switch of the probe to check whether the returning signal (X4.7) is actuated.. The cable for the element of the probe is poor connection or broken. Please check and replace the cable. 2. Some element of the probe (-A206) is defective, please replace the probe. Press the RESET key. 2 End 8-9

19 022 TOOL LIFE EXHAUST ALARM 022 Counting of tool used (time or times) has been reached. Consult Chap4 5. setting. Press the RESET key. End 8-20

20 023 MAG OT IPOSITIO! 2 ALARM 023 Press the RESET key Is the POT in the horizontal position? The diagnosis X6.3= Is the magazine in the position? Change to the JOG mode 7 The diagnosis X6.3= Press the POT vertical button and release it to make the POT return to the horizontal position. Change to the JOG mode Is the POT in the horizontal position? Press the MAG CW/CCW button and release it to make the MAG rotate one 4 Is the MAG motor start? DG 2.6= 5 Is the MAG motor stop? 6 Cause:. The button of POT vertical is defective. Please replace it. 2. The wiring of POT vertical button is poor contact. Please check the wiring

21 3 4. The wiring of the solenoid valve for POT H is poor contact. Please check the wiring. 2. The solenoid valve for POT H is defective. Please replace it. 3. The relay (K48, K49) damage. Please check it. 2 5 DG X6.3= Cause:. The limit switch for POT H detects incorrectly. Please check it. 2.The limit switch for POT H is defective. Please replace it. 2 2 The diagnosis 4.7= 6 Cause:. The MCC or relay of MAG Cause: CW/CCW is defective. Please. The wiring of MAG CW/CCW replace it. button is poor contact. Please check the wiring. 2. The wiring of MCC or relay for 2. The button of MAG CW/CCW MAG CW/CCW is poor contact. is defective. Please replace it. Please check the wiring. 3. The MAG motor is overload or damage. Please check it. 7 DG 4.7= DG C2 = at the present tool number Press the EMG button Cause:. The limit switch for MAG counter is defective. Please replace it. 2. The limit switch for MAG counter detects incorrectly. Please adjust it. 3.The relay (K404 K405) of MAG CW/CCW contacts incorrectly or damage. Please check it. 8-22

22 024 STC TEMP FAILED! ALARM 024 Press the RESET key Please check the signal of STC temperature card in the electrical cabinet. Finish. o 24V power input 2. STC temperature card is broken Please call for service 8-23

23 026 JIG EED CLAMP! ALARM 026 Is there optional JIG function? Set keeprelays K4.4=0 (M54 M55) K4.=0 (M56 M57) Is there APC function? Jig must be clamping during spindle rotation. 3 Press the RESET key. Do jig clamping by pressing the JIG CLAMP UCLAMP button or execute the command of jig clamping under the AUTO mode. Execute the command of spindle rotation. Is the alarm still there? 2 End 8-24

24 2 Is the jig clamped? Set timers T8=500 (M54 FIISH TIME) T20=500 (M55 FIISH TIME) T22=500 (M56 FIISH TIME) T24=500 (M57 FIISH TIME) Are limit switches used for detecting jig clamping unclamping?. Some limit switch on the jig is defective. Please replace it. (-S25, -S26, -S27, -S28) 2. Some limit switch on the jig detects incorrectly. Please adjust it. (-S25, -S26, -S27, -S28). The relay for jig is defective. Please replace it. (-K233, -K234, -K238, -K239) 2. The solenoid valve for jig clamping is defective. Please replace it. (-22, -23, -24, -25) 3. The wiring for the solenoid valve is poor contact. Please check the wiring. (-22, -23, -24, -25) 4. Some hydraulic pipe for jig clamping is clogged. Please clean the pipe or replace it. 8-25

25 3 Jig must be clamping during spindle rotation. Is there optional JIG function on the pallet A? Set keeprelays K4.4=0 (M54 M55) K4.=0 (M56 M57) Is there optional JIG function on the pallet B? Is the pallet A in the machining area? 4 Press the RESET key. Under the MDI or AUTO mode, execute the command for jig clamping (M54 M56) to do jig clamping. 6 Execute the command of spindle rotation. Is the alarm still there? End

26 5 Is the jig in the machining area clamping? Set timers T8=500 (M54 FIISH TIME) T20=500 (M55 FIISH TIME) T22=500 (M56 FIISH TIME) T24=500 (M57 FIISH TIME) Are limit switches used for detecting jig clamping unclamping?. Some limit switch on the jig is defective. Please replace it. (-S25, -S26, -S27, -S28) 2. Some limit switch on the jig detects incorrectly. Please adjust it. (-S25, -S26, -S27, -S28). The relay for jig is defective. Please replace it. (-K233, -K234, -K238, -K239) 2. The solenoid valve for jig clamping is defective. Please replace it. (-22, -23, -24, -25) 3. The wiring for the solenoid valve is poor contact. Please check the wiring. (-22, -23, -24, -25) 4. Some hydraulic pipe for jig clamping is clogged. Please clean the pipe or replace it

27 4 Press the RESET key. Under the MDI or AUTO mode, execute the command for jig clamping (M58 M60) to do jig clamping. 7 Execute the command of spindle rotation. Is the alarm still there? End

28 027 AIR PRESSURE FAILED ALARM 027 Is the pressure of air source enough? Regulate the pressure of air source. Press the RESET key. Is the alarm still there? End. Wiring for air pressure detector(-a203) is incorrect. Please check the wiring. 2. Air pressure detector (-A203) isdefective. Please replace it. 8-29

29 028 ATC (D52) SETTIG ERROR ALARM 028 Is there magazine unit? ` Consult Chap2 5.2 setting. (D52) Re-start the machine. Make sure D52=99. End 8-30

30 029 SP TOOL CLAMPIG FAILED! ALARM 029 Press limit switches (S304, S305) for tool clamping and check whether the diagnostic X5.=.. The limit switch for tool clamping is defective. Please replace it. 2. The limit switch detects incorrectly. Please adjust it. 3. The wiring for limit switch is poor contact. Please check the wiring. 4. The wiring of rowed cable for CC is poor contact. Please check the rowed cable. End 8-3

31 030 MAG (D5) SETTIG ERROR! ALARM 030 Is there magazine unit? ` Consult Chap2 5. setting. (D5) Re-start the machine. Make sure D52=99. End 8-32

32 03 TOOL SEARCHIG FAILED ALARM 03 Tool searching cannot be finished in the defined time limit. Does the magazine rotate?. The limit switch for pot horizontal (S40) is defective. Please replace it. 2. The limit switch for pot horizontal detects incorrectly (X6.3). Please adjust it. 3. The wiring for pot horizontal is poor contact. Please check the wiring. 4. The contact of relay (K404,2.2) Execute the T command.. The limit switch (S40) for pot counter is defective. Please replace it. 2. The limit switch for pot counter detects incorrectly (X7.0). Please adjust it. 3. The wiring of limit switch for pot counter is poor contact. Please check the wiring Is the alarm still there? End 8-33

33 032 AUTO DOOR FAILED ALARM 032 The automatic door open close works over the set time limit. Timer T2=xxxx Refer to the article regarding setting Re-set the timer T2. 2 Is the automatic door closed? Diagnostic.6=. The limit switch (-S20, -S202) for automatic door is defective. Please replace it. 2. The limit switch (-S20, -S202) for automatic door detects incorrectly. Please adjust them. 2 Diagnostics X8.= X8.0=0 Press the RESET key. Execute the command of automatic door open close (M0 M). Is the alarm still there?. The automatic door gets interference. Please remove the obstacle. 2. The air pressure for the automatic door is too low. Please enlarge the pressure of the air source. 3. The solenoid valve (-207, -2) for automatic door is defective. Please replace it. 4. The wiring of the solenoid valve (-207, -2) for automatic door is poor contact. Please check the wiring 5. The relay (-K268, -K269) for automatic door is defective. Please replace it. 2 2 End 8-34

34 033 PAEL SETTIG ERROR! ALARM 033 Consult Chap2 5.2 setting. (D50). Re-start the machine. End 8-35

35 034 SPIDLE TOOLS OVERLOAD! ALARM 034 Press the RESET key Is the spindle tool broke or damaged The settings in spindle overload delay time (T48) is tool short, please refer to the timer setting of Chap2 5.. Change tool ED 8-36

36 035 WORKPIECE PROBER ERROR! ALARM 035 Press the RESET key Is the signal of prober and receiver are out off measure range? The diagnosis X7.7= Cause:. Is the prober or receiver broken? (-A206) 2. The wiring of prober and receiver is poor contact. Please check the wiring. Adjust the position of receiver. Setting the prober on spindle then move the z axis, make sure the signal can receive in full travel. ED 8-37

37 036 OIL AIR LUBE ERROR! ALARM 036 Is the oil level of the oil-air lubricating system too low? DG X5.7=? Is the air pressure for the oil-air lubricating system not enough? End Regulate the air pressure (referring to the mechanical maintenance manul). The pressure switch (-A203) is defective or poor contact. Please replace or check the wiring. 8-38

38 037 DC24V POWER SUPPL ERROR! ALARM 037 DC24V Power supply damage or wrong error, please change or check wiring. Press the RESET key. End 046 WORKPIECE PROBE LOW BATTER! ALARM 046 Cause: Workpiece probe battery life is too low or defective. Please change it. Press the RESET key ED 8-39

39 049 APC DOOR OP CL APC ARM TPE (TPE 3) (K4.6=, APC WITHOUT DOOR) ALARM Diagnostics X3.= Close X3.0= Open Is the APC door opened? The APC door close is not finished in the defined time limit. 2 Is the APC door closed?

40 2 3. The limit switch (S536) for APC door open is defective. Please replace it. 2. The wiring of the limit switch for APC door open is connected incorrectly or circuit broken. Please check it and replace the broken one.. The limit switch (S537) for APC door close is defective. Please replace it. 2. The wiring of the limit switch for APC door close is connected incorrectly or circuit broken. Please check it and replace the broken one.. The solenoid valve (K50, K502) for APC door is defective. Please replace it. 2. The wiring of the solenoid valve for APC door is connected incorrectly or circuit broken. Please check it and replace the broken one. Diagnostic X3.= Close Press the RESET key. 3 Execute the command M9 M92 again. Is the alarm still there? End 5 8-4

41 049 APC DOOR OPE CLOSE FAIL β6 TPE(TPE 4) (K4.6=, APC WITHOUT DOOR) ALARM Diagnostics X3.= Close X3.0= Open APC door close is not finished in the defined time limit. Is the APC door opened? 2 Is the APC door closed? 2 Select the JOG mode and press the APC DOOR OPE button. Is the APC door Closed? Diagnostics 6.=

42 2 3. The limit switch (S536) for APC door open is defective. Please replace it. 2. The wiring of the limit switch for APC door open is connected incorrectly or circuit broken. Please check it and replace the broken one.. The limit switch (S537) for APC door close is defective. Please replace it. 2. The wiring of the limit switch for APC door close is connected incorrectly or circuit broken. Please check it and replace the broken one.. The solenoid valve (K50, K502) for APC door is defective. Please replace it. 2. The wiring of the solenoid valve for APC door is connected incorrectly or circuit broken. Please check it and replace the broken one Diagnostic X3.= Close Press the RESET key. 2. The solenoid valve (K50, K502) for APC door is defective. Please replace it. 2. The wiring of the solenoid valve for APC door is connected incorrectly or circuit broken. Please check it and replace the broken one. End

43 050 TABLE CLAMP UCLAMP FAIL! ALARM 050 Is the EMERGEC STOP button released? Table clamping unclamping is not finished in the defined time limit. 2 Diagnostic 6.6= Diagnostic 6.7= Is the table is clamped? Is the table is unclamped?

44 The limit switch (S538) for table clamping is defective. Please replace it. 2. The wiring of the limit switch for table clamping is connected incorrectly or circuit broken. Please check it and replace the broken one. 3. The limit switch for table clamping detects incorrectly. Please adjust it.. The limit switch (S539) for table unclamping is defective. Please replace it. 2. The wiring of the limit switch for table unclamping is connected incorrectly or circuit broken. Please check it and replace the broken one. 3. The limit switch for table unclamping detects incorrectly. Please adjust it.. The solenoid valve (K504, K505) for table clamping unclamping is defective. Please replace it. 2. The wiring of the solenoid valve for table clamping unclamping is connected incorrectly or circuit broken. Please check it and replace the broken one. 2 Is the table is unclamped? Please release the EMERGEC STOP button.. 3 Please execute the command M85 to do table clamping.. Diagnostics X3.3= X3.4=0 3 Press the RESET key. End 8-45

45 05 APC Z AXIS EED RETE! ALARM 05 Execute zero return of the Z axis. Press the RESET key. End 8-46

46 054 APC SWAP TIME EXCEED ALARM 054 The APC pallet change is not finished in the defined time limit. Check limit switches. Pallet A - Locating pin locked (X3.7) 2. Pallet A - Locating pin unlocked (X4.0) 3. Pallet B - Locating pin locked (X4.) 4. Pallet B - Locating pin unlocked (X4.2) 5. Table clamping (X3.3) If anyone is defective, please replace it. Check solenoid valves. Table clamping (6.6), unclamping (6.7) 2. APC door open (6.0), close (6.) 3. Pallet A - Locating pin locked (7.) 4. Pallet A - Locating pin unlocked (7.0) 5. Pallet B - Locating pin locked (7.2) 6. Pallet B - Locating pin unlocked (7.3) Execute the command of pallet change. Is the alarm still there? End 8-47

47 057 ATC OT READ (FOR SIMPLE DISK TPE 20T) ALARM 057 Is the Z axis at the ATC position? Diagnostic F7.0= (Absolute type of servo motor) Please refer to the ALM09 to solve the problem. Is the magazine close to the spindle? Diagnostics X6.2=, X6.3=0 Select the JOG mode and press the TOOL UCLAMP button to do spindle tool unclamping. Before the magazine returns the standby position, make sure no tool will drop down. Or, remove tools on spindle or magazine. Is the spindle tool unclamped? 3 Diagnostics X5.2=, X5.=0 9 7 Select a manual mode to move the Z axis toward the positive direction until the Z axis getting the signal of interlock.f70.7= (Absolute type of servo motor). The limit switch (S305, S307) for spindle tool clamping unclamping is defective. Please replace it. 2. The limit switch for spindle tool clamping unclamping detects incorrectly. Please adjust it

48 2 Press the EMERGEC STOP button and release it. Is the spindle tool clamped? Diagnostic 2.7 = 0 8 Diagnostics X5.=, X5.2=0 9 3 Select the JOG mode and press the MAG BACKWARD button to retract the magazine to the standy position. Does the magazine go backward? Diagnostic 2.3= Diagnostics X6.2=0, X6.3= Set the spindle tool no. at the adress D440. Try commands M6 Txx again

49 The limit switch (S404) for magazine backward is defective. Please replace it. 2. The limit switch for magazine backward detects incorrectly. Please adjust it.. The magnetic switch (K29) for magazine backward is defective. Please replace it. 2. The wiring of the magnetic switch for magazine backward is poor contact. Please check the wiring. 3. The magazine is jammed. Please repair it. The MAGAZIE BACKWARD button (S65) is defective. Please replace it. 2. The wiring of the MAGAZIE BACKWARD button is poor contact. Please check the wiring. 3. Conditions are not satisfied. Please check the setting. 7 8 Diagnostic 2.7=. The solenoid valve (32) for tool clamping unclamping is defective. Please replace it. 2. The wiring for tool clamping unclamping is poor contact. Please check the wiring.. The TOOL UCLAMP button (S638) is defective. Please replace it. 2. The wiring of the TOOL UCLAMP button is poor contact. Please check the wiring. 3. Conditions are not satisfied. Please check the setting. 0 Is the alarm still there? End 8-50

50 058 ATC DOOR OT CLOSES! (FOR DC ALARM 058 Press the RESET key 2 Execute the M78 command for close the ATC door Is ATC door close? The diagnostic 5.=. The ATC door gets DG X0.= interference. Please remove the obstacle. 2. The air pressure for ATC Cause:. The limit switch for ATC door is defective. Please replace it. (-S233) 2. The limit switch for ATC door detects incorrectly. Please adjust it. (-S233) 2 ED Is the alarm still there? door is too low. Please enlarge the pressure of the air source (-A203). 3. The solenoid valve is defective. Please replace it. (-40) 4. The wiring of the solenoid valve is poor contact. Please check the wiring. (-40) 5. The relay for POT is defective. Please replace it. (-K255) 2 8-5

51 059 TOOL MEASURE COVERS OT OPE! ALARM 059 Press the RESET key Execute the M20 command for open the tool measure cover Is the cover open? DG 4.5= (-20) Cause:. The limit switch for tool measure cover is defective. Please replace it. 2. Tool measurement is defective DG X.2= (A202) Cause:. The solenoid valve for tool measure cover is defective. Please replace it. (-20) 2. The wiring of the solenoid valve for tool measure cover is poor contact. Please check the wiring. (-20) 3. The relay for POT is defective. Please replace it. (-K228) ED 8-52

52 060 JIG CW/CCW OVERTIME! ALARM 060 Modify the setting of JIG CW/CCW timer consult Chap2 5. setting (T66) Is the alarm still there? ED Cause:. The limit switch for JIG CW/CCW is defective. Please replace it. 2. The limit switch for JIG CW/CCW detects incorrectly. Please adjust it. 8-53

53 06 M6 POT V ERROR! ALARM 06 Confirm the ATC type. Consult Chap2 During maintenance? K4.7= 4 Re-command M6 Is POT vertical? ED 8-54

54 The diagnostic 2.5=(-4) 4 Is POT vertical? DG X6.2= 4 Cause:. The POT gets interference. Please remove the obstacle. 2. The air pressure for POT is too low. Please enlarge the pressure of the air source (-A203). 3. The limit switch (-S4) for POT vertical is defective. Please replace it. 4. The limit switch for POT vertical detects incorrectly. Please adjust it. 5. Please check the wiring and signal. Cause:. The solenoid valve (-4) for POT is defective. Please replace it. 2. The wiring of the solenoid valve (-4) for POT is poor contact. Please check the wiring. 3. The relay (-K49) for POT is defective. Please replace it

55 062 M6 ARM L.S ERROR! ALARM 062 Confirm the ATC type. Consult Chap2 During maintenance? K4.7= Re-command M6 Check the limit switch for ATC reference point, brake and spindle tool clamping/unclamping are correct. Cause:. The limit switch (-S46 S42 S45) is defective. Please replace it. 2. The limit switch detects incorrectly. Please adjust it. 3. Please check the wiring and signal. ED 8-56

56 063 M6 SPIDLE UCLAMP ERROR! ALARM 063 During maintenance? K4.7= Re-command M6 DG 2.7= Is the spindle tool unclamped? DG X5.= (-S306) ED Cause:. The air pressure for spindle tool clamping/ unclamping is too low. Please enlarge the pressure of the air source (-A203). 2. The limit switch (-S306) for spindle tool clamping/ unclamping is defective. Please replace it. 3. The limit switch for spindle tool clamping/ unclamping detects incorrectly. Please adjust it. 4. Please check the wiring and signal. Cause:. The solenoid valve (-302) for spindle tool clamping/ unclamping is defective. Please replace it. 2. The wiring of the solenoid valve (-302) for spindle tool clamping/ unclamping is poor contact. Please check the wiring. 3. The relay (-K32) for spindle tool clamping/ unclamping is defective. Please replace it. 8-57

57 064 M6 SPIDLE CLAMP ERROR! ALARM 064 During maintenance? K4.7= Re-command M6 DG 2.7=0 Is the spindle tool clamped? Cause: DG X5.= (-S304). The solenoid valve (-302) for spindle tool clamping/ unclamping is defective. Please replace it. Cause: 2. The wiring of the solenoid valve. The air pressure for spindle tool (-302) for spindle tool clamping/ clamping/ unclamping is too low. Please unclamping is poor contact. Please enlarge the pressure of the air source check the wiring ED (-A203). 2. The limit switch (-S306) for spindle 3. The relay (-K32) for spindle tool clamping/ unclamping is defective. tool clamping/ unclamping is defective. Please replace it. Please replace it. 3. The limit switch for spindle tool clamping/ unclamping detects incorrectly. Please adjust it. ` 4. Please check the wiring and signal. 8-58

58 065 OE TF COMMAD! ALARM 065 Enter T code instruct again. 068 IVERTER BREAKDOW ALARM ALARM 068 Inverter breakdown alarm check the LED displayed code of inverter Please refer to the inverter operation manual (maintain-error-reason-solution) for trouble shooting. ED 8-59

59 07 STC TEMP ERROR! ALARM 07 Press the RESET key Please check the signal is correct or not of STC temperature card in electrical cabinet. STC temperature sensor has been broken. Please call for service. Is the ALARM 07 still displaying Finish Please call for service 8-60

60 072 SP. TEMP ERROR! ALARM 072 Press the RESET key. Is the ALARM 072 still displaying Finish Press the RESET key after 0 minutes. Finish 8-6

61 073 SP. EED WARM UP! ALARM 073 Press the RESET key. Following the C process to run the warming up program. Continue working process after the warming up program completed. 8-62

62 900 PLEASE TUR OFF POWER! Please turn off the power ED 8-63

CNC MILLING MACHINE TROUBLE SHOOTING. 1. Trouble Shooting. No Trouble Solution. 1.Check the air pressure

CNC MILLING MACHINE TROUBLE SHOOTING. 1. Trouble Shooting. No Trouble Solution. 1.Check the air pressure CNC MILLING MACHINE TROUBLE SHOOTING 1. Trouble Shooting No Trouble Solution 1 Tool magazine( (Umbrella type) Noise for tool changing Can t change the tool Tool number in chaos Tool magazine keep rotation

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

101 COMM. FAILURE WITH MOCON/MOCON MEMORY FAULT

101 COMM. FAILURE WITH MOCON/MOCON MEMORY FAULT Al a r m s Any time an alarm is present, the lower right hand corner of the screen will have a blinking Alarm. Push the Alarm display key to view the current alarm. All alarms are displayed with a reference

More information

HIGH PRODUCTION DUAL DRIVE HORIZONTAL MACHINING CENTER

HIGH PRODUCTION DUAL DRIVE HORIZONTAL MACHINING CENTER HIGH PRODUCTION DUAL DRIVE HORIZONTAL MACHINING CENTER 14001 認 可 登 錄 14001 認 可 登 錄 1 Introducing all new H630B high speed horizontal machining center. Incorporates state of the art Dual Drive technology

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

A.3 ALARMS (SERIAL SPINDLE)

A.3 ALARMS (SERIAL SPINDLE) A.3 ALARMS (SERIAL SPINDLE) NOTE*1 Note that the meanings of the indications differ depending on which LED, the red or yellow LED, is on. When the red LED is on, the indicates a 2 digit alarm number. When

More information

DC-8706K Auto Dial Alarm System

DC-8706K Auto Dial Alarm System DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power

More information

REMOTE CONTROL MANUAL

REMOTE CONTROL MANUAL REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read

More information

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS INSTALLATION MANUAL Before you begin the installation Read the INSTRUCTIONS! Always use a multi-meter when verifying vehicle wiring. Before mounting the

More information

How To Control A Car Alarm On A Car With A Remote Control System

How To Control A Car Alarm On A Car With A Remote Control System MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Fire Alarm Control Panel. Family. Operating Manual

Fire Alarm Control Panel. Family. Operating Manual Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...

More information

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications

More information

Fig 3. PLC Relay Output

Fig 3. PLC Relay Output 1. Function of a PLC PLC Basics A PLC is a microprocessor-based controller with multiple inputs and outputs. It uses a programmable memory to store instructions and carry out functions to control machines

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

IQAN MDM Operation Manual

IQAN MDM Operation Manual IQAN MDM Operation Manual Purpose The primary purpose of this document is to inform a user of the IQAN system on the ease of adjustments of the system. A person can create a much smoother machine control

More information

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM The shift lock system is designed to ensure the proper operation of the automatic transmission. The driver must depress the brake pedal in order to move the gear selector from Park

More information

DUGARD. Machine Tools Since 1939. Dugard 700L Series Heavy Duty CNC Lathes. www.dugard.com

DUGARD. Machine Tools Since 1939. Dugard 700L Series Heavy Duty CNC Lathes. www.dugard.com DUGARD Machine Tools Since 1939 Dugard 700L Series Heavy Duty CNC Lathes www.dugard.com Dugard 700L Heavy Duty CNC Lathe 2000, 3000 or 4000mm bed length Designed for easy and convenient operation The concave

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the

More information

A/C-HEATER SYSTEM - AUTOMATIC

A/C-HEATER SYSTEM - AUTOMATIC A/C-HEATER SYSTEM - AUTOMATIC 1995 Volvo 850 1995-96 Auto. A/C-Heater Systems Volvo 850 * PLEASE READ THIS FIRST * WARNING: To avoid injury from accidental air bag deployment, read and carefully follow

More information

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness WIRING HARNESS FOR AS635P4 ANTENNA NOT USED 5 PIN WHITE PLUG 2 PIN WHITE PLUG GREEN - PARKING BRAKE INPUT (-) BLUE - NOT USED 3 PIN BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

More information

Hydraulic Trouble Shooting

Hydraulic Trouble Shooting Hydraulic Trouble Shooting Hydraulic systems can be very simple, such as a hand pump pumping up a small hydraulic jack, or very complex, with several pumps, complex valving, accumulators, and many cylinders

More information

CONTINUOUSLY VARIABLE TRANSMISSION (CVT)

CONTINUOUSLY VARIABLE TRANSMISSION (CVT) GROUP 23 CONTINUOUSLY VARIABLE TRANSMISSION (CVT) CONTENTS CVT........................... 23-2 GENERAL INFORMATION............. 23-2 ELECTRONIC CONTROL SYSTEM...... 23-3 EEPROM...........................

More information

14. Troubleshooting Guide

14. Troubleshooting Guide 14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include

More information

Pos. Qty. Article Descripiton Price /

Pos. Qty. Article Descripiton Price / Offer 1 1 Vertical CNC-machining centre Mill 800 40 tools Partly refurbished pre-owned machine Delivered 2003 Weight approx. 7000 kg Machine-No. 220-52 Column moving machining centre with fixed table NC

More information

Signature and ISX CM870 Electronics

Signature and ISX CM870 Electronics Signature and ISX CM870 Electronics Cummins West Training Center System Description General Information The Signature and ISX CM870 engine control system is an electronically operated fuel control system

More information

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

ELECTRIC POSITION for electric heat, then confirm with Fan Test below. Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4 Mini CNC Interface for LPT Port Version 4 Product Brief This breakout-board is designed to connect up to four stepper or servo drives to the parallel port of a PC. This requires the use of a CNC controller

More information

Conventional Fire Detection and Extinguishant Control System Specification

Conventional Fire Detection and Extinguishant Control System Specification Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release

More information

6. Diagnostics for A/C System Malfunction

6. Diagnostics for A/C System Malfunction 6. A: A/C OR SELF-DIAGNOSIS SYSTEMS DO NOT OPERATE TROUBLE SYMPTOM: Set temperature is not indicated on the display, switch LEDs are faulty or switches do not operate. Self-diagnosis system does not operate.

More information

Electrical Systems - IQAN Digital Control System. IQAN Control System Components... 5.1.3

Electrical Systems - IQAN Digital Control System. IQAN Control System Components... 5.1.3 Section 5.1 Electrical Systems - IQAN Digital Control System IQAN Control System Components........................... 5.1.3 IQAN Operational Description: At Machine Startup.....................................

More information

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop

More information

SAMSUNG Machine Tools

SAMSUNG Machine Tools SAMSUNG Machine Tools VERTICAL MACHINING CENTER SMEC Co., Ltd. 666, Gasul-ri, Daesan-myeon, Changwon-si Gyeongsangnam-do, Korea 641-921 Tel +82 55 250 4800 Fax +82 55 253 5355 http://www.esmec.com www.esmec.com

More information

CNC LASER MACHINE (AMNC-F) ALARM LISTS

CNC LASER MACHINE (AMNC-F) ALARM LISTS CNC LASER MACHINE (AMNC-F) ALARM LISTS LASER-AMNC-F ALARM-E03-200901 CONTENTS 1. Description...3 2. Machine alarms...4 3. Executor alarms...32 4. Alarm details...39 4-1. Details of machine alarm No. 2507

More information

Electronic Manual Gearbox

Electronic Manual Gearbox Service. Self-Study Programme 221 Electronic Manual Gearbox Design and Function Taking the Lupo as the basis, Volkswagen has developed the world's first 3 L car that will also go into volume production.

More information

How To Set Off An Alarm On A Car With A Car Alarm On It

How To Set Off An Alarm On A Car With A Car Alarm On It AUTO SECURITY SYSTEM USER S OPERATION GUIDE FCC ID NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference,

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

2.1 FOR Series 15i. 2.1.1 Servo Alarm - 65 - TROUBLESHOOTING 2.ALARM NUMBERS AND BRIEF DESCRIPTIONS. Alarm No. SVM PSM Description Remarks

2.1 FOR Series 15i. 2.1.1 Servo Alarm - 65 - TROUBLESHOOTING 2.ALARM NUMBERS AND BRIEF DESCRIPTIONS. Alarm No. SVM PSM Description Remarks B-65285EN/01 TROUBLESHOOTING 2.ALARM NUMBERS AND BRIEF DESCRIPTIONS 2.1 FOR Series 15i 2.1.1 Servo SVM PSM Description Remarks SV0027 Invalid digital servo parameter setting 3.3.6 SV0361 Pulse coder phase

More information

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... ..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com

More information

1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING

1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING 1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: regulateurs@regulateurs-europa.com 1115 4G

More information

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual Battery Tester GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G 40 & 42HD Operator s Manual SPECIFICATIONS Measurement Range...Ferret 40... Ferret 42HD Battery Volts... 4.0 to 19.99...

More information

SAMSUNG Machine Tools

SAMSUNG Machine Tools SAMSUNG Machine Tools LCV 55 / 65 / 8 VERTICAL MACHINING CENTERS SMEC Co., Ltd. 6671, Gasulri, Daesanmyeon, Changwonsi Gyeongsangnamdo, Korea 641921 Tel +82 55 25 4832(48) Fax +82 55 25 491(492) http://www.esmec.com

More information

LAND ROVER MANUAL CONTENTS APPLICATIONS GENERAL OPERATION SPECIAL FUNCTIONS REMOTE CONTROL PROGRAMMING

LAND ROVER MANUAL CONTENTS APPLICATIONS GENERAL OPERATION SPECIAL FUNCTIONS REMOTE CONTROL PROGRAMMING LAND ROVER LAND ROVER MANUAL CONTENTS APPLICATIONS GENERAL OPERATION SPECIAL FUNCTIONS REMOTE CONTROL PROGRAMMING APPLICATIONS VEHICLE SYSTEM YEAR CABLE CLASSIC RANGE ROVER 10AS 95 ON ADC110-B DEFENDER

More information

1R / 4-BUTTON SERIES

1R / 4-BUTTON SERIES Button 1 1R / 4-BUTTON SERIES VEHICLE SECURITY SYSTEM Standard Features: Two 4-Button Remote Transmitters Status indicator (LED) Valet / override switch Multi-tone siren Dual stage impact detector Remote

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

Trouble shooting for die cast machine. customer service department of L.K Group

Trouble shooting for die cast machine. customer service department of L.K Group Trouble shooting for die cast machine customer service department of L.K Group A. Faults Detect and the Steps for Repair Important When faults occurred on die casting machine operation. Operators should

More information

500r+ Installation and User Guide

500r+ Installation and User Guide 500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and

More information

CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive

More information

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will

More information

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM SECTION 7D AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM TABLE OF CONTENTS Description and Operation... 7D- General... 7D- FATC Control... 7D- FATC Input/Output Routing Diagram...

More information

Thermo Top - Troubleshooting Tree

Thermo Top - Troubleshooting Tree Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may

More information

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section

More information

MELDAS is a registered trademark of Mitsubishi Electric Corporation. Other company and product names that appear in this manual are trademarks or

MELDAS is a registered trademark of Mitsubishi Electric Corporation. Other company and product names that appear in this manual are trademarks or MELDAS is a registered trademark of Mitsubishi Electric Corporation. Other company and product names that appear in this manual are trademarks or registered trademarks of the respective companies. PREFACE

More information

Lebanese University Faculty of Engineering II. Final year project. Electrical Engineering Degree. Hady Zeinoun Antoine Zeidan. Cut to length line

Lebanese University Faculty of Engineering II. Final year project. Electrical Engineering Degree. Hady Zeinoun Antoine Zeidan. Cut to length line Lebanese University Faculty of Engineering II Final year project Submitted in fulfillment of the requirements for the Electrical Engineering Degree by Hady Zeinoun Antoine Zeidan Cut to length line Project

More information

Troubleshooting Guide for Jacks Down LED Lights

Troubleshooting Guide for Jacks Down LED Lights Troubleshooting Guide for Jacks Down LED Lights Equalizer Systems Auto-Level systems manufactured after 2005 feature a pressure switch system that monitors the retracted state of leveling jacks and any

More information

[9] TROUBLE CODE LIST

[9] TROUBLE CODE LIST [9] TROUBLE CODE LIST 1. Trouble list Content E1 00 IMC PWB communication trouble 10 IMC PWB trouble 11 IMC ASIC error 13 IMC PWB flash ROM error 16 IMC PWB DIMM memory read/write check error 81 Interface

More information

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE

More information

Home Security Alarm System

Home Security Alarm System Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better

More information

Streaming Potential System (SPT1000, SPD1000)

Streaming Potential System (SPT1000, SPD1000) Streaming Potential System (SPT1000, SPD1000) User's Manual Sentrol Systems, Inc. 3949 Cotswold Dr. SW, Lilburn, GA 30047-2371 Tel: 770-564-1541, Fax: 770-564-8605 www.sentrolsystems.com Since the streaming

More information

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives DOCUMENT: ECSEQ6-0 EFFECTIVE: 09/23/10 SUPERSEDES: Operational Overview and Controls Guide Two or Three Pump IronHeart Lite with Variable Frequency Drives 6700 Best Friend Road. Norcross, GA 30071. (770)

More information

GSM home alarm system s manual

GSM home alarm system s manual GSM home alarm system s manual I. Main features: 1, Eight wireless LED zone, and four wired zone 2, Two-way to communication 3, The system supports the GSM cell phones, no need the fixed telephone line.

More information

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC Page. Basic Diagnostic Procedure.... General Description...3 3. Electrical Components Location...6 4. A/C Control Module I/O Signal...8 5. Self-diagnosis...0 6.

More information

i ChatterBox! Motorcycle Security

i ChatterBox! Motorcycle Security i Before you Start the Installation * Please read this manual to become familiar with the requirements necessary to complete the installation. * Use a high quality multi-meter to test all wires before

More information

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting. Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

Fault Diagnosis and Maintenance for CNC Machine. Based on PLC

Fault Diagnosis and Maintenance for CNC Machine. Based on PLC Fault Diagnosis and Maintenance for CNC Machine Based on PLC Deng Sanpeng [1, 2] Xu Xiaoli [2, 3] Chen Tao [2] 1.Tianjin University of Technology and Education,300222; 2. Beijing Institute of Technology,100081;

More information

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS WG2 Dimensions: LxHXW: 26 x 14.5 x 29.5 cm INTERNAL Alarm Terminals EXTERNAL Alarm Terminals WG2 Control Unit WaterGuard

More information

Business/ Home GSM Alarm System

Business/ Home GSM Alarm System Business/ Home GSM Alarm System BUSINESS/HOME GSM ALARM SYSTEM POWER STATUS RECORD SIGNAL User Manual Profile For a better understanding of this product, please read this user manual thoroughly before

More information

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target 4-2 ABNORMAL OPERATI 4-2-1 An is represented by 3 digit characters. The first 2 digit means the subsection, and the last 1 digit means the specifics. Ex.) Indoor unit Network communication Error Subsection

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................

More information

ELECTRICAL WIRING (R.H. DRIVE VEHICLES)

ELECTRICAL WIRING (R.H. DRIVE VEHICLES) C-1 ELECTRICAL WIRING (R.H. DRIVE VEHICLES) CONTENTS GENERAL.......................... 3 WIRING HARNESS CONFIGURATION DIAGRAMS......................... 4 ENGINE COMPARTMENT................ 4 DASH PANEL...........................

More information

Six-defense zone Display Alarm System. User Manual

Six-defense zone Display Alarm System. User Manual Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.

Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function. Schematic symbols are used to identify and graphically depict the function of fluid power components. Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.

More information

Operating Instructions. Single Loop Controller EC48 & EC96

Operating Instructions. Single Loop Controller EC48 & EC96 Operating Instructions Single Loop Controller EC48 & EC96 03/2010 PSG Plastic Service GmbH 1 Operating Instructions EC48 & EC96 Table of Contents 1 Introduction... 3 1.1 Typographical Conventions... 4

More information

Using your LED Plus keypad

Using your LED Plus keypad Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

INSTALLATION GUIDE. www.security.soundstream.com FCC ID NOTICE

INSTALLATION GUIDE. www.security.soundstream.com FCC ID NOTICE AL.1 AUTO SECURITY SYSTEM INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or

More information

About Your System NOTE: What is included: Options and Accessories:

About Your System NOTE: What is included: Options and Accessories: 2-WAY CAR ALARM SYSTEM WITH REMOTE ENGINE START E8 MODEL IMPORTANT: Please read the entire manual for complete details on the features, accessories and operation before attempting to use your security

More information

WRG EVENT CODE LISTING

WRG EVENT CODE LISTING WRG EVENT CODE LISTING Code Meaning Required Action 1001 Administrator entered the program 1002 Administrator got the balance 1003 Administrator set the balance 1004 Administrator added to the balance

More information

UBM-W SERIES CNC HORIZONTAL BORING & MILLING MACHINE. http://www.uchine.com.tw. CNC Double Column Machining Center UDM series

UBM-W SERIES CNC HORIZONTAL BORING & MILLING MACHINE. http://www.uchine.com.tw. CNC Double Column Machining Center UDM series CNC Double Column Machining Center UDM series CNC Horizontal Heavy Duty Milling Machine UMM series CNC Horizontal Machining Center UHM series Conventional Horizontal Boring & Milling Machine UBM series

More information

SECURITY SYSTEM ADP-CAN

SECURITY SYSTEM ADP-CAN INSTALLATION INSTRUCTION SECURITY SYSTEM ADP-CAN Introduction Motorcar security system ADP-CAN is for motorcars provided with CAN net. It is for the work with the motorcar factory security systems or remote

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

Table of Contents. General Operation 2. Air Blast Cleaning System 3. Setup 4. Changing Ticket Bags 5. Loading Printer Paper 6. Tower Light Status 7

Table of Contents. General Operation 2. Air Blast Cleaning System 3. Setup 4. Changing Ticket Bags 5. Loading Printer Paper 6. Tower Light Status 7 Table of Contents General Operation Air Blast Cleaning System Setup Changing Ticket Bags Loading Printer Paper Tower Light Status Ticket Taker General - Ticket Taker Overview - Ticket Taker Operation Clearing

More information

Diagnostic Trouble Code (DTC) Charts

Diagnostic Trouble Code (DTC) Charts Diagnostic Trouble Code (DTC) Charts Note: Before proceeding to the Pinpoint Test, refer to the Diagnostic Trouble Code (DTC) Descriptions for additional information to assist in diagnosis. 6.0L Diesel

More information

*.ppt 11/2/2009 12:48 PM 1

*.ppt 11/2/2009 12:48 PM 1 Digital Compressor Controller *.ppt 11/2/2009 12:48 PM 1 Copeland Scroll Digital Controller Simple Controller That Enables OEM s To Use Digital Scrolls Relieves OEM From Developing Special Controllers

More information

SC-32 CNC LATHE OPERATION MANUAL

SC-32 CNC LATHE OPERATION MANUAL SC-32 OPERATION MANUAL NCT Ipari Elektronikai Kft. 1 / 29 Dátum: 2013.09.27. CONTENTS 1. ACCURACY RECORD... 2 2. SAFETY PRECAUTIONS... 2 2.1. Safety Rules... 2 2.2. Warning label attaching positions...

More information

Dyeing Programmer DP - 01

Dyeing Programmer DP - 01 Dyeing Programmer DP - 01 Display and Controls. 1) Display: 16/2 alphanumeric display 2) Temperature range: 0 to 150 degree. 3) Resolution: 1 degree. 4) Accuracy: +/- 1 degree. 5) Temperature control setting:

More information

CNC Milling Engraving machine G4030A Instruction manual

CNC Milling Engraving machine G4030A Instruction manual CNC Milling Engraving machine G4030A Instruction manual 1. Safety notes Every machine controlled by computer (PC) can be really dangerous for human life and health. Comply with bolow rules and use Your

More information

GSM Home Alarm System User Manual. http://www.usmartbuy.com

GSM Home Alarm System User Manual. http://www.usmartbuy.com GSM Home Alarm System User Manual http://www.usmartbuy.com 1 1. Factory default Normally, all sensors in the big box have been coded (learnt) to the control host Operation Password: 0000 Long-Distance

More information

Business/Home GSM Alarm System. Installation and User Manual

Business/Home GSM Alarm System. Installation and User Manual Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene

More information

DUGARD. DUGARD Machine. Dugard Heavy Duty Vertical Machining Centres. Machine Tools That Create Solutions Since 1939. Tools

DUGARD. DUGARD Machine. Dugard Heavy Duty Vertical Machining Centres. Machine Tools That Create Solutions Since 1939. Tools DUGARD Machine Tools That Create Solutions Since 1939 Dugard Heavy Duty Vertical Machining Centres DUGARD Machine Tools www.dugard.com sales@dugard.com 01273 732286 The unique inverted slideway design

More information