Telephone Controller INSTRUCTION MANUAL MODEL CT240-01



Similar documents
TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Automatic Phone-Out Home Monitoring Systems

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

PagePac PAGEPAL V

CONTROL SWITCHER User s Manual (Preliminary)

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

How to read this guide

Advantium 2 Plus Alarm

USB/VGA Cat 5 UTP Console Extender

WF720 Wireless Home Phone User Manual

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Installation and Operation Back-UPS 1250, 1300, 1500

Single Station Remote Alarm

Printed in China. Issue 1.2 AT&T 03/07. Advanced American Telephones. AT&T and the AT&T logo are trademarks of AT&T Knowledge Ventures, licensed to

TAC2C & TAC2D TAC1 RETROFIT KIT FOR CROWN JEWEL & DOORKING 1812 SYSTEMS

2.4 GHz Dual Handset Cordless Telephone Answering System 2255 with Caller ID/Call Waiting

HomeSeer Technologies. HomeSeer Technologies LLC 35 Constitution Dr, Suite C Bedford NH,

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

Back-UPS Pro 1300/1500 Installation and Operation

HERZ-Thermal Actuators

User Manual THR840DUK Digital Thermostat

Personal Assistance System Owner's Guide

Operating Instructions. Telephone System tiptel 1/8 fax clip tiptel 2/8 clip. (Release 2) tiptel

The following is a set of definitions used in FAQs for the Partner product line:

INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

Printed in China. Issue 4 AT&T 12/11. Message Guard is a registered trademark of Advanced American Telephones.

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: Fax:

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

Adapter GL386. User Manual is available in other languages at

For Models #6-5001, #6-7501, # & #10-12K1

Touch Tone Controller. Model TR16A. Owner s Manual

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Installation & Operation Instructions

Model Owner s Manual. Español - P. 19 Français - P. 39

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

AUTODIALLER / QUICKDIALLER - SA132

TECHNICAL. Add Peripherals without Changing Your Phone System C-1000A. Door Entry Controller

Basic Alarm BD A. What You Will Need: 1. One 9-volt alkaline or lithium battery (not included). 2. Phillips screwdriver (not included) 2

EZ Hold USER MANUAL EZ HOLD. Music On Hold. Models M2060, EZM480. EZ ADVANTAGE CORP., 221, Broad Street, MILFORD, CT U.S.A.

Installation & Operation Manual for EC-8 Phone Line Consolidator

Web Power Switch III User s Guide Revision LPC-3

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

e-ask electronic Access Security Keyless-entry

Fan Coil EC Motor Control

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

4-Port Pocket. USB KVM Switch with USB 2.0 Hub

Single Phase Soft Starter

CQM1-SF200/CS1W-SF200

Table of Contents. Hardware Installation...7 Push Button Security Using the Setup Wizard Configuration...11 Main Security...

INSTRUCTION MANUAL. FOR TECHNICAL ASSISTANCE: VERSION 3.2 ITEM #330

ISDN 970 Telephone USER MANUAL. Copyright 1999 Lucent Technologies Inc. All rights reserved. Printed in Mexico. Issue L

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

CHAPTER 1. GETTING STARTED... 1

OPERATING INSTRUCTIONS FOR LED-4 MULTI-SPORT TABLETOP SCOREBOARD

Dock-N-Talk U S E R S G U I D E. Forming a New World of Communication. SM

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

VOIP Business Phone User Guide

Four-Line Intercom Speakerphone 944

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Rousseau 10. User Guide

KD-204. Telephone Remote Switch. Operating Instructions

AT&T Small Business System Speakerphone with Intercom and Caller ID/Call Waiting 974

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

Reject calls from callers who block their Caller ID information so their calls don't even ring on your line.

User s manual. Corded telephone. w w w.v t e c h c a n a d a. c o m. Big Button Big Display. Model:CD1281 DIR CID

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program

HP UPS R1500 Generation 3

Auto Dialer. Manual E-921APQ E-921GPQ

PR-2500 Portable Receiver. Owner s Manual

User Guide VERIZON WIRELESS HOME PHONE CONNECT

-Helping to make your life betterwww.person-to-person.net

How To Connect A Port Replicator With An Ethernet To A Usb Port From A Usb Device

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Model PBX 416+ Programming & User Guide

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T

DALI RC BASIC SO. Control unit Operating instructions

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Water Leak Detection System

DIGITAL TELEPHONE INTERFACE REF. R3615

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Remote Control Repeater

Four-Line Small Business System Speakerphone 945

14. Troubleshooting Guide

Install Guide CT101. Caution. Caution

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio

Transcription:

INSTRUCTION MANUAL Telephone Controller We thank you for trusting Aube technologies and hope that you will be entirely satisfied. For any questions concerning the CT240 telephone remote control, please call our Technical Support Department at: 1-800-831-AUBE (2823) MODEL CT240-01 Montreal Area: www.aubetech.com (450) 358-4600 service@aubetech.com TABLE OF CONTENTS SUMMARY...6 1. INSTALLATION...7 1.1 Connection to Aube technologies Thermostats......8 1.1.1 Connection to the TH140-TH141 Models........9 1.1.2 Connection to the TH123, TH11, TH10X-T Models........9 1.2 Connection to Another Company's Thermostats........11 1.3 Connection to an Automatic Device........12 3. CHANGING THE STATUS FROM THE CT240...17 4. RESETTING TO THE DEFAULT VALUES...18 5. USING A TELEPHONE ANSWERING MACHINE...19 6. LIGHT INDICATORS...20 7. TECHNICAL SPECIFICATIONS...21 WARRANTY...22 2. USING WITH A TELEPHONE...13 2.1 Accessing the Telephone Controller with the Access Code.......14 2.2 Current Output Status.......14 2.3 Changing the Output Status...15 2.4 Changing the Access Code.........15 2.5 Changing the Number of Rings...........16 2.6 Logging Off...16

SUMMARY This telephone controller was designed to be used with most thermostats equipped with a telephone interface. A special output provides unidirectional control (to the thermostat) with Aube technologies TH140-TH141 thermostats. An auxiliary output allows the simultaneous control of an additional charge such as water heater, lighting, etc. 5 6 1. INSTALLATION Any device connected to a telephone line must conform to the country's regulations. The CT240-01 model meets the FCC68 standard for installation on the North-American network. To install a telephone controller in another country, please contact our Customer Service Department for advice on the appropriate model. 1. Mount the CT240 on a wall close to a telephone outlet. 2. Insert one end of the telephone cable in the "Line" connector on the CT240 and the other end into a telephone outlet in your home. 3. Connect the CT240 to your thermostat following the diagram below. 1.1 CONNECTION TO AUBE TECHNOLOGIES THERMOSTATS The A-B-C terminals provide a direct connection to Aube technologies thermostats. MATERIAL PROVIDED One CT240-01 One 120 V power transformer One 5-meter telephone cable 7 8

1.1.1 Connection to the TH140-TH141 Models You can activate or deactivate the Vacation function from the telephone or the CT240. It is possible to hook up in parallel up to ten TH123, TH11X-COM, TH10X-COM thermostats on the AC outlet of the CT240. 1.1.2 Connection to the TH123, TH11X-COM, TH10X-COM Models 9 10 1.2 CONNECTION TO ANOTHER COMPANY'S THERMOSTATS It is possible to use the auxiliary outlet (terminals 1-2-3) to connect another manufacturer's thermostat. The outlet for the Aube thermostats (terminals A-B-C) and the auxiliary outlet answer the commands simultaneously. For connection, refer to your thermostat manufacturer's instruction manual. 1.3 CONNECTION TO AN AUTOMATIC DEVICE The auxiliary output allows you, for example, to activate the entry lighting, reactivate the water heater and set the thermostat of your secondary residence to the Comfort mode with a single command. The capacity of the auxiliary outlet (1-2-3) relay is 250 V/10A. However, to avoid electrical shocks, the direct connection of a charge with a tension higher than 30 VAC is not permitted, unless the CT240 is installed inside an electrical box certified by the standard setting body of the country. "Vacation" mode (DEL On): Contacts 1-2 closed Contacts 2-3 opened 11 12

2. USING WITH A TELEPHONE It is possible to change the status of the CT240 output relay and to switch your thermostat mode via the telephone or by using the Vacation button on the CT240. In all cases, the control light under the Vacation button goes on to indicate that the telephone remote control is in "Vacation" mode (contacts 1-2 of the auxiliary relay are closed, contacts 2-3 are opened and the thermostat is in "Vacation" mode). By default, the CT240 is configured to answer after four telephone rings and to accept the access code "1234". These settings are programmable. You can modify them by referring to sections 2.4 and 2.5. 2.1 ACCESSING THE TELEPHONE CONTROLLER WITH THE ACCESS CODE Note that the CT240 will automatically hang up if no keys are touched for 30 seconds. 2.2 CURRENT OUTPUT STATUS ( ) 13 14 2.3 CHANGING THE OUTPUT STATUS ( ).5 CHANGING THE NUMBER OF RINGS ( ) 2.4 CHANGING THE ACCESS CODE ( ) 2.6 LOGGING OFF ( ) When you have finished, press to end the session with the CT240. You can also simply hang up the handset. The CT240 will then disconnect within 30 seconds. * If you enter the wrong access code more than 3 times, the communication will stop and you will have to go back to step 3. 15 16

3. CHANGING THE STATUS FROM THE CT240 You can switch the relay status and the thermostat mode by pressing on the CT240 Vacation button. This function is not accessible while the CT240 is answering a telephone communication. 4. RESETTING TO THE DEFAULT VALUES It is possible to return to the default values by using a paper clip to press the Default button located to the left side of the telephone line outlet. The indicator light located above the button will flash 3 times to signal that the remote control has been reset to the following values: 1) Number of rings: 4 2) Access code: 1234 3) Output status: Thermostat mode = Comfort Relay contacts 1-2 opened Relay contacts 2-3 closed "Vacation" mode (DEL On): Contacts 1-2 closed Contacts 2-3 opened Thermostat mode = Vacation 17 18 5. USING A TELEPHONE ANSWERING MACHINE If you own a telephone answering machine as well as the telephone controller, follow this procedure to access the controller by telephone: 1- Place the switch, located on the back of the CT240, in the answering machine mode. When you change the switch position, you must unplug the CT240 so the change can be effective. 2- Make sure the answering machine answers after a certain number of rings. This number has to be higher than 4. 3- Call home, let the telephone ring once and hang up. 4- Wait 10 seconds and call back. 5- The CT240 will answer on the first ring. However, you must call back within 30 seconds. 6. LIGHT INDICATORS The CT240's five light indicators allow you to diagnose your installation. Power: Indicates that the circuit is under tension. Ring: Flashes during ringing. Hook: Indicates that the remote control has opened the line. Default: Flashes 3 times to indicate that the reset has been accepted. Vacation: Indicates the CT240 output status. It is on when the CT240 is in "Vacation" mode. Note that programming a certain number of rings before the CT240 is activated has no effect when it is used with an answering machine. 19 20

7. TECHNICAL SPECIFICATIONS Power supply of 9 VAC/50 Hz or 12 Vcc, 200 ma 1 SPDT output contact with the following capacity: 10 A/30 VAC resistive 5 A/30 VAC inductive F.P.O.4 10 A/250 V resistive (if the CT240 is installed inside a certified electrical box) 1 hp/250 V motor (if the CT240 is installed inside a certified electrical box) 1/2 hp/120 V (if the CT240 is installed inside a certified electrical box) Class 2 insulation Manual selection of the output contact status Programmable access code In case of power failure, the output status and the access code are memorized Viewing the output status Connects directly to the telephone line Compatible with a telephone answering machine FCC68 certified for connection to the North-American telephone network WARRANTY This product is guaranteed against workmanship defects for a two-year period following the initial date of purchase in an authorized retail store. During this period, AUBE technologies inc. will repair or replace, at its option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products badly installed or damaged by accident. This warranty cancels and replaces any other manufacturer's express or tacit warranty as well as any other company commitment. AUBE technologies inc. cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address: 21 22 AUBE TECHNOLOGIES INC. SERVICE CENTER 705 Montrichard Iberville (Québec) Canada J2X 5K8 Tél. : (450) 358-4600 1-800-831-AUBE (2823) Fax : (450) 358-4650 www.aubetech.com service@aubetech.com 27/03/00 720-2400108