REDWALL-V adjustment procedures guide



Similar documents
PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

AX-100TFR/AX-200 TFR INSTALLATION INSTRUCTIONS INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR.

LED MOTION ACTIVATED FLOOD LIGHT

Passive Infrared Motion Detector 5420/90. Installation Instructions

This icon denotes a situation involving the risk of serious injury or even death, if the warning given is ignored.

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

5W LED Energy Saver PIR Bulkhead

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Wireless Home Security Alarm System AM 500

LED Security Spotlight User Manual

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit

Your Simple Guide to Battery. Replacement. Customer Care:

Treasure Cove Metal Detector

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN

12-Volt Negative Ground Installation Instructions

Speed-Mat Rectangle Cutter

FIRERAY 2000 Installation Guide

Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

DCMT-2500 Wireless Transmitter. Owner s Manual

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

CALIBRATION FOR LAL20X & LAL24X

LED MOTION ACTIVATED FLOOD LIGHT

QUICK REFERENCE MANUAL

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

ASSEMBLY MANUAL SE-4S35

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Sliding Door Hardware Installation Instructions

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

INSTALLATION AND OPERATION MANUAL

GE Wireless Devices Battery Replacement

Compliments of SwatchBattery.com

TS93 EMR T/PT/TDE. Surface applied door closer

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Operating Instructions. Room temperature controller

16/32 Channel 1U Rack Mount CCTV Power Supply

4.3-inch Back-Up Camera

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Beam Laser Pointer Service Manual

Universal Gauge Measuring System USERS MANUAL

SIMPLEX UNICAN LOCKS CHANGING THE CODE / COMBINATION 900 Series 1000 Series L1000 Series LP1000 Series EE1000 Series 2000 Series 2015 Series

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Wireless 7 Day Programmable Room Thermostat

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

5800 Temperature Sensor Cable Assembly

How To Make A Commercial Detector

Gold Century GC-1023 Metal Detector

Manual for GlobePharma Mini-Press II Rotary Tablet Press

Automatic Phone-Out Home Monitoring Systems

HOME GYM. Model. Retain This Manual for Reference OWNER'S MANUAL.

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

2013 Wireless Video Intercom INSTALLATION GUIDE

Control Box Wiring For PRSstandard Tool

Wiper Motor Marinco 2.5. Installation Instructions

PREVENTATIVE MAINTENANCE

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

12 Volt 30 Amp Digital Solar Charge Controller

Smart Cam, CC-Smart-Cam, and Smart Cam Packages Installation and Quick Start Operating Instructions

E E V R E - R S - O S L O A L R

SC 7000 and SC 9000XL Patient Monitors SC 9000XL Monitor 12in (30.5cm) Display Service Manual Supplement Two

Auto Sentry-eXP Maintenance

Stereoscopic 3D Digital Theater System. Operator Manual (MI-2100)

Fiberstars Lighted Laminar Flow Fountain Installation Manual

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Drayton Digistat +2RF/+3RF

Wireless Home Security System Product Manual (Model #80355)

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

LOS 2500 SUPER CEILING SENSOR. Installation Manual

Sport Ice Elektro 124

Wireless Alarm system s manual

Home Signal Distribution Kit for Satellite TV Plus SIRIUS

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

LUCCI AIRFUSION QUEST II CEILING FAN

Exakta 6x6 No

majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

TUTA B12. User Manual GSM REMOTE CAMERA. Manual version 3.0

CorkSport Mazdaspeed 6 Rear Sway Bar Mazdaspeed 6

WM002 LCD Display Wall Mounting Kit Installation Guide. Welcome

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales


USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

SELF-STEERING AXLE TABLE OF CONTENTS

CAD-05 Kit GSM Auto Dialer. Owner s Manual

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Radiant Temperature Sensor TY7321

I BEAM TRACK INSTALLATION

SmartLogger1000. Quick Installation Guide. Issue 05. Date HUAWEI TECHNOLOGIES CO., LTD.

Transcription:

Page 1/18 Ver1.2 July 1. 2011 REDWALL-V adjustment procedures guide This document is provided as a reference tool for installing the Optex Redwall SIP passive infrared detector. Before starting, read the instruction book that comes with the unit. Before starting any installation, please confirm if proper power is provided to the SIP unit. Requirements SIP detector main unit *Included in the kit Area plate Area masking seal Allen Key Tweezers *Optional (but necessary) adjustment tools AVF-1 AWT-3 Area View Area Walk Finder Tester *Other useful tools Cross slot Screwdriver Volt meter Measure wheel

Page 2/18 Contents (Step) 1 Rough vertical angle adjustment 2 Rough horizontal angle adjustment 3 Mounting the AVF-1 (initial) 4 Checking the edge of the far area 5 Fine angle adjustment 6 Setting the AWT-3 7 Preparation for a walk test 8 Confirming the condition in the detection area 9 Walk testing the unit 10 Walk testing to confirm the obstacle s location 11 Mounting the AVF-1 (for false-alarm avoidance) 12 Recording the obstacle s location 13 Preparation of masking 14 Masking the optics 15 Setting the AWT-3 (confirming correct masking) 16 Conduct walk test to confirm successful masking 17 Setting the Creep zone 18 Switch settings for Sensitivity and Sensor Logic 19 Walk testing to reconfirm the detection area 20 Completion of area setting (Page) 3 4 4 6 6 7 7 8 8 9 9 9 10 10 14 14 15 16 17 17

Page 3/18 Step1. Rough vertical angle adjustment 1. Measure the installation height. 2. Loosen the fixing screw by allen key. 3. Adjust the vertical position with Angle Adjustment guide according to installation height. 2 Arrow of the main unit Installation height at 2.3m(7.6ft.) Installation height at 4m(13ft.) If the height is between 2.3m and 4m, set in the middle. If the mounting wall is at an angle, this guide might not apply. In such case, adjust carefully with walk test.

Page 4/18 Step2. Rough horizontal angle adjustment 1. Loosen the side adjustment screw by Allen key. (Loosen the screw on the opposite side to where its to be aimed) 2. Rotate the main unit horizontally to desired area. 3. Tighten the adjustment screw slightly. Step3. Mounting the AVF-1 (initial) Remove the cover before mounting the AVF-1 View Finder 1. Loosen two securing screws. 2. Hold the head of the both screw with your hand and pull them out. 3. Slide the cover downward and release the hooks. 1 3 2

Page 5/18 Mounting the AVF-1 (initial) 1. Put the red string attached to the View Finder around the main unit so that it does not accidently fall. 2. Insert and mount AVF-1 to the main unit. *One of two holes is notched to accept correct arm of AVF-1. It will not mount to the SIP incorrectly, otherwise. For convenience, the AVF-1 unit can be rotated. 3. Peel off the protection seals from both sides of the area plate. 4. Insert the area plate into the slot of View Finder so that the arrow points up. 5. Look through the inspection window of AVF-1 View Finder. 6. Make sure that center circle of the area plate comes inside center circle of the lens and the detection area.. Confirm the proper plate is used.

Page 6/18 Actual site view View through the AVF-1 Step4. Checking the edge of the far area 1. Adjust the horizontal angle of the main unit in order to effectively cover the area required to protect, and avoid possible areas of false alarms. 2. Check the center of the farthest detection area. 3. Measure the detection distance toward the point. 4. Make a person stand at the point. Rating distance e.g. SIP-3020 = 30m (100ft.) Step5. Fine angle adjustment Adjust the vertical and horizontal angle of the main unit to get the position that the person is located in the most far detection area.

Page 7/18 Step6. Setting the AWT-3 1. Remove the AVF-1 from the unit, and then put the plug of AWT-3 into the unit. AWT-3 AVF-1 2. Confirm that CONNECTION SELECT SWITCH is at REDWALL-V. 3. MODE SELECT SWITCH is used for Far, Near and Creep zone detection. 2 3 Step7. Preparation for walk test Change all sensitivity switch to SH, and confirm if the position of logic selector is OR. Dark gray area

Page 8/18 Step8. Confirming the condition in the detection area 1. Slide POWER SELECT SWITCH to POWER SUPPLY FROM SENSOR 2. Check to ensure the tone is constant (that there is no one in the detection area). *No detection: low tone *Detection: High tone If not, there might be an object that could be the cause of a false alarm. Remove the object or mask it later. Check FAR area. Check NEAR area. Check CREEP zone. Step9. Walk test 1. Conduct walk test to confirm the recent position of the person is actually in the most far detection area or re-adjust the unit to the area. Check FAR area 2. Confirm the detection area is set properly, and check FAR area and NEAR area independently.

Page 9/18 Step10. Walk test to confirm the obstacle s location Conduct walk test to confirm the location of obstacles and that there are road, trees, bushes, compressor of air-conditioner which may cause false alarms. Step11. Mounting the AVF-1 (for false-alarm avoidance) Remove the AWT-3 from the unit, and then put the AVF-1 on the unit again. AVF-1 AWT-3 Step12. Recording the obstacle s location Confirm the location of obstacle and record the mirror segment that should be masked. Example: Obstacle (large plant) is in segment F6, 1and 2, so the mirror F6, 1 and 2 should be masked. Record F6, 1 and 2 for masking.

Page 10/18 Step13. Preparation of masking 1. Remove the AVF-1. 2. Remove the lens window. (Press the left bottom hole with your finger, and pull the window up.) Step14. Masking the optics Because of mirroring effects, the position of the mirror you mask should be different from that of the detection segment of AVF-1. (What is seen on the left is physically on the right-side of the mirror. For example, in Step12, segment F6 should be masked like below.) See next page

Page 11/18 Masking the Far Area Detection There are 2 options when masking the Far Area detection. a.) Use Detection range selector switch (except SIP-5030, SIP-100) When use this switch, all Far area detection is cancelled. Far area zone b.) Use Masking plates to narrow detection area, from outside inward. 1. Masking plates are equipped inside the main unit. 3. Confirm which mirror should be masked by area chart. Fixing rubber 2. Take fixing rubbers off and the plates can be moved. Be careful of mirroring effects. If some object covers the zone 1 and 2, opposite side of mirror needs to be masked (photo above).

Page 12/18 4. Attach the masking plate to the mirror and secure it to ribs. 5. Insert the fixing rubber to secure the knob of the masking plate. Masking the Near Area Detection There are 2 options when masking the Near Area detection. a.) Use Masking plates to narrow detection area Be careful of mirroring effects. Like far area, take the masking plate out and mask outside detection area. But you can mask the outside detection area only (the zone 1 and 6 in area chart above). Therefore, use the area masking seal to mask the other detection area.

Page 13/18 Masking the Near Area Detection b.) Use Masking Seals to eliminate specific unwanted segment Note: This is a permanent countermeasure! 1. Confirm obstacle s location F6 recorded through Step12. 2. Attach carefully the masking seal to the mirror by using tweezers.

Step15. Setting the AWT-3 (confirming correct masking) Page 14/18 Put the plug of the AWT-3 on the unit again. Step16. Conduct walk test to confirm successful masking Confirm the unwanted segments are properly eliminated. Check both Far area and Near area independently. 1. Check FAR area 2. Check NEAR area If the tone doesn t change when a person walks through unwanted segment(s), the segment is properly eliminated.

Page 15/18 Step17. Setting the Creep zone Adjust creep zone detector for SIP3020/5, 404/5, 4010/5, 100 and 5030. If the unit is without creep zone, go to step18. 1. Loosen the screw and remove the lid of creep unit. Find sign to return to at the 0 2. Adjust the detection angle horizontally and vertically. a) Adjust between 90 and 90 degree horizontally b) Adjust between 3 and 3 degree vertically 3. Conduct walk test whether the detection area has been set as required. If not, re-adjust it. 4. Put the lid of creep unit back and fasten the screw.

Step18. Switch settings for Sensitivity and Sensor Logic Page 16/18 Do not forget to return the sensitivity switch to M and logic selector to AND. (But it depends on application and situation.) a.) Sensitivity When conducting Walk-test, please set at SH. In case that the SIP installed 2.3m (7.6 ) Factory default is M position. After confirmation of the detection area, adjust the proper sensitivity. When M position is too sensitive, select L position. In case that SIP installed at 4m (13ft.), Sensitivity settings for Far and Near areas may need to be changed to H position. b.) Logic Detection logic selection is determined when an object is detected in either of the two detection areas (OR) or when an object is detected within the two detection areas (AND). at OR AND B (or A) A B (both A and B) c.) Alarm interval You can set an interval (4 different times) to suspend the alarm signal output. When detection area setting, this function shall not be used.

Page 17/18 Step19. Walk testing to reconfirm the detection area Conduct a walk test to confirm the SIP detects a person in the detection area. 1. Check FAR area. 2. Check NEAR area. 3. Check CREEP zone. Step20. Completing the installation Remove the AWT-3, put the cover on the main unit and fasten the securing screw.

Page 18/18 Other options For Mounting SIP Series Detectors to Double Gang weather proof box: SR-MPLT POLE MOUNTING BRACKET FOR SIP-SERIES DETECTORS SIP-PMBR When detectors are used under 20 C degree, this heating unit can expand the operating temperature to 40 C degree. SIP-HU Heating unit (use 24VAC) For protection from sun-light and snow: SIPMINIHOOD for SIP-404, 4010, 3020, SIP-404/5, SIP-4010/5, SIP- 3020/5 SIPMIDIHOOD for SIP-5030/100 All information is provided as references without any warranty of any kind, either expressed or implied, including but not limited to fitness for a particular use. Any user shall assume the entire risk as to the accuracy and use of this information. Due to continual product improvement, the design and specifications are subject to change without prior notice. This document is subject to copyright owned by OPTEX CO., LTD. You may not copy, communicate to the public, adapt, distribute, modify or publish any contents of this document without the express prior written consent of OPTEX CO., LTD.