Secondary Unit Substations



Similar documents
Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Primary and Secondary Electrical Distribution Systems

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Distribution Dry Type Transformers

Fusible Disconnect Switch

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Contents. Description. Product Selection Guide

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

8146/5 Series Breaker Panelboards

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

How To Choose A Transformer

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

SWITCHGEAR. EGP Switchgear

Switchgear and Metal-Enclosed Bus

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Switchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR

Unified requirements for systems with voltages above 1 kv up to 15 kv

Sample - No Commercial Use

Engineers Edge, LLC PDH & Professional Training

How To Test A Power Switch On A Power Supply

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

This section applies to the design and installation of transformers.

SENTRON Switching and Protection Devices Air Circuit Breakers

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

MCC Ratings. Voltage Rating

Tmax MCCBs. Molded case circuit breakers. Tmax

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

The Intelligent AX1 Switchgear for Medium Voltage

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Short Circuit Current Calculations

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Chapter 1. Network Structures

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Medium Voltage Motor Control Assemblies

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

4160: THE GREEN 480 MEDIUM VOLTAGE ELECTRICAL SYSTEMS

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Securing your electrical installations Prisma,

Cable/Conduit Conversion

The power distribution board that sets new standards

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Advantages of Fixed Circuit Breaker Switchgear

Modular Systems wind portfolio overview Power Collection and Grid Connection products

STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS

Alternate Methods to Short Circuit Breaker Coordination

Medium voltage indoor circuit breakers ANSI/IEC solutions

Current Limiting Protector For Systems rated kV and continuous currents through 5000A.

Introduction. Upon completion of Basics of Electrical Products, you should be able to:

CAS 36 Ring Main Unit

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

MEDIUM VOLTAGE METAL CLAD SWITCHGEAR

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

MEDIUM VOLTAGE. Michael Mosman, PE. CCG Facilities Integration Incorporated FACILITIES INTEGRATION INCORPORATED

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

SIVACON The Versatile Low-Voltage Switchboard

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

Arc Terminator Active Arc-Resistant Switchgear

Bolted contact switches. Pringle switches

Power-Zone 4 Arc Resistant Low Voltage Switchgear

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

Mini Power-Zone Unit Substation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Distribution Dry Type Transformers

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Extend the Life of Existing Switchgear

Instructions for Magnum DS T

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Choosing the Best Solution for Reducing Arc Energy

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Element D Services Electrical

SECTION MEDIUM VOLTAGE SWITCHGEAR

QUESTIONS and ANSWERS RFB , Metal Clad Switchgear and Power Control Room

Transcription:

14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically and electrically connected to and coordinated in design with one or more switchgear or switchboard assemblies. A secondary unit substation is defined as a unit substation whose outgoing section is rated below 1000 volts. A typical secondary unit substation consists of three sections: n Primary: an incoming section that accepts incoming high voltage (2400 to 13,800 volts) line n Transformer: section that transforms incoming voltage down to utilization voltage (600 volts or less) n Secondary: an outgoing section that distributes power to outgoing feeders and provides protection for these feeders (600 volts and less) Standard secondary unit substations consist of: n Medium Voltage Primary n Transformer n Low Voltage Secondary Siemens also offers low voltage unit substations with: n Low Voltage Primary n Transformer n Low Voltage Secondary The primary reason for using a secondary unit substation is to bring power as close as possible to the center of the loads. Another reason is that it provides a system design concept incorporating a wide variety of components that permits tailoring equipment to the needs of the application. A secondary unit substation provides n Reduced power losses n Better voltage regulation n Improved service continuity n Increased functional flexibility n Lower installation cost n Efficient space utilization Every component and assembly of secondary unit substations are designed and engineered as an integral part of a complete system. Primary Switch Primary Switch Liquid Filled Transformer Dry Type Transformer General Switchboard with WL Encased Systems Breakers Type SB3 Switchboard with Fusible Switches Primary Switch Liquid Filled Transformer Type WL Low Voltage Switchgear For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 14-40 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

5 27.6 kv Type SIMOSEC Metal-Enclosed Load Interrupter Primary Switch SIMOSEC Specifications n Extremely compact footprint n Meets ANSI/IEEE C37.20.3 n UL or C-UL listing available n Seismic compliant up to IBC 2003 n High switching capacity - 100 operations at 600A - five times higher than ANSI requirements n Gas-insulated, three-position switch\ disconnector, hermetically sealed for life inside a stainless steel vessel n Switch-disconnector combines the functions of a load-interrupter switch(with CLOSED-OPEN indication) and an optional grounding switch (with OPEN-GROUND indication) n Front accessible fuses and outgoing cables, which means type SIMOSEC switches can be placed against the wall and maximize the use of available space n Convenient viewing window for visible verification of primary contact position (visible break) n Standard capacitive voltage indicators to show whether the cable side is energized or not n Integrated mechanical interlocking n Animated mimic diagram (mimic bus) n Main bus at top or bottom to suit application n Configurations: individual feeder switches, transformer primary switches and switch line-ups n Ideal for utility, construction and industrial applications n Over 20 years of field experience with more than 350,000 switch-disconnector units installed n Switch-disconnector contacts maintenance free and sealed for life. n Main bus continuous current rating (row title) (blank 2nd column from left) and 1,200 A in each of three columns on right 14 SWITCHGEAR Dimensions Cable switch CS Fused switch FS Duplex switch Width Single cable or fuse Three cables or double-barrel fuse Two cables + SA or 3-barrel fuse 14.8 (375 mm) 19.7 (500 mm) 29.6 (750 mm) 14.8 (375 mm) 19.7 (500 mm) 29.6 (750 mm) 19.7 (500 mm) + 19.7 (500 mm) 29.6 (750 mm) + 19.7 (500 mm) Depth Height 48.4 (1,230 mm) 88.6-100.4 (2,250-2,850 mm) depending on arrangement Technical Data Rated voltage 5 kv 8.25 kv and 15 kv 27.6 kv Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz Rated short-duration power-frequency withstand voltage 19 kv 36 kv 60 kv Rated lightning-impulse withstand voltage (BIL) 60 kv 95 kv 125 kv Rated short-time withstand current, two seconds Up to 25 ka Up to 25 ka Up to 20 ka Fused short-circuit current rating (FS panels only) Single fuse FS-1 Double fuse FS-2 Triple fuse FS-3 63 ka (to 450E) 63 ka (to two 350E) 63 ka (to three 200E) 63 ka (to 200E) 63 ka (to two 200E) 63 ka (to three 200E) 20 ka 20 ka 20 ka Maximum fused continuous current (not equal to fuse E rating) Switch disconnector Single fuse FS-1 325 A 165 A 65 A Double fuse FS-2 575 A 305 A 117 A Triple fuse FS-3 600 A 430 A 156 A Continuous 600 A 600 A 600 A Interrupting 600 A 600 A 600 A Main bus continuous current rating 1,200 A 1,200 A 1,200 A Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog 14-41

High-voltage (HV) Fuse Selection Table General High-voltage (HV) Fuse Selection Table 14 SWITCHGEAR Allowable continuous current (A) Maximum voltage (kv) Fuse type E -rating (open air) FS-1 FS-2 FS-3 5.5 55GDMSJ10ES 10E 10 5.5 55GDMSJ15E 15E 15 5.5 55GDMSJ20ES 20E 20 5.5 55GDMSJ25ES 25E 25 5.5 55GDMSJ30ES 30E 30 5.5 55GDMSJ40ES 40E 40 5.5 55GDMSJ50ES 50E 50 5.5 55GDMSJ65ES 65E 65 5.5 55GDMSJ80ES 80E 80 5.5 55GDMSJ100ES 100E 100 5.5 55GDMSJ125ES 125E 120 5.5 55GFMSJ150ES 150E 150 5.5 55GFMSJ175ES 175E 164 5.5 55GFMSJ200ES 200E 183 327 5.5 55GFMSJ250ES 250E 220 390 5.5 55GFMSJ300ES 300E 241 429 598 5.5 55GFMSJ350ES 350E 269 478 600 5.5 55GFMSJ400ES 400E 302 536 600 5.5 55GFMSJ450ES 450E 325 575 600 17.5 175GDMSJ10ES 10E 10 17.5 175GDMSJ15ES 15E 15 17.5 175GDMSJ20ES 20E 20 17.5 175GDMSJ25ES 25E 25 17.5 175GDMSJ30ES 30E 30 17.5 175GFMSJ40ES 40E 40 17.5 175GFMSJ50ES 50E 50 17.5 175GFMSJ65ES 65E 59 17.5 175GXMSJ80ES 80E 73 17.5 175GXMSJ100ES 100E 85 17.5 175GXQSJ125ES 125E 112 207 17.5 175GXQSJ150ES 150E 123 238 336 15.5 155GXQSJ175ES 175E 167 310 420 15.5 155GXQSJ200ES 200E 165 305 430 Example: n 5,000 kva, 12.47 kv transformer n Full-load current 231.5 A n Multiplier 1.33 n Current for fuse-size selection = 1.33 x 231.5 A - 308 A n Multiplier of 1.33 for transformer with fan-cooled rating 125% of self-cooled rating (adjust multiplier for differing fan-cooled transformer capability) n Fuse rating = 2 x 175E/phase (FS-2). FS-1: One fuse barrel per phase FS-2: Two fuse barrels per phase FS-3: Three fuse barrels per phase 14-42 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

Overview Siemens offers a wide variety of unit substation designs to meet virtually any customer requirement. A unit substation consists of one or more transformers mechanically and electrically connected to, and coordinated with, one or more switchgear or switchboard assemblies. A secondary unit substation is defined as a unit substation whose outgoing section is rated below 1,000 volts. A typical secondary unit substation consists of three sections: n Primary: depending on the specific application, this section accepts medium voltage (2,400 to 27,600 volts) incoming power n Transformer: reduces incoming voltage to utilization voltage (600 volts or less) n Secondary: distributes power to, and provides protection for, outgoing feeders (600 volts and less). SIMOSEC Primary Switch Dry-Type Transformer Type SB3 Switchboard 14 SWITCHGEAR The key benefit of a secondary unit substation is that it economically brings power as close as possible to the loads, minimizing power loss and maximizing voltage regulation. It also enhances flexibility, using a system design concept that integrates a wide variety of components to tailor the equipment to the specific needs of each application. Every component or assembly utilized in secondary unit substations is engineered to be an integral part of a complete system. A secondary unit substation helps you: n Reduce power losses n Enhance voltage regulation n Improve service continuity n Increase functional flexibility n Lower installation costs n Minimize space utilization. SIMOSEC Primary Switch Liquid Filled Type Transformer Type SB3 Switchboard Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog 14-43

Transformers: Dry Type VPI/VPE 4 in. 4 in. D Plan view W HV-terminal Danger Fan control panel H HV air terminal chamber (optional) N.P. Fan control when req. LV air terminal chamber (optional) Front Ground bus 14 18 in. (457 mm) Std. Front view indoor 18 in. (457 mm) Std. W Front view outdoor SWITCHGEAR Type = VPI/VPE Primary Volts = 2400-13800 Sec_Volts = 208-600 Temperature Rise = 150C for Aluminum Windings, 80/115C for Copper Windings Standard kv BIL (HV/LV) = 60/30 for Aluminum Windings, 95/30 for Copper Windings Table 1 Low Voltage Switchgear or Switchboard Coordination Winding Material KVA Height (Inches) Width (Inches) Depth (Inches) Weight (Pounds) Aluminum 300 90 90 54 4600 Aluminum 500 90 90 54 4800 Aluminum 750 90 90 54 5800 Aluminum 1000 90 102 60 7000 Aluminum 1500 96 102 60 9200 Aluminum 2000 102 102 60 11000 Aluminum 2500 108 112 60 12200 Aluminum 3000 108 118 60 14100 Aluminum 3750 112 126 66 15800 Aluminum 5000 118 132 66 17000 Copper 300 90 90 54 6000 Copper 500 90 96 60 6400 Copper 750 90 102 60 8000 Copper 1000 96 102 60 9700 Copper 1500 102 108 60 13200 Copper 2000 108 112 60 17400 Copper 2500 118 126 60 19000 Copper 3000 118 132 60 22000 Copper 3750 126 132 66 27000 Copper 5000 132 138 66 30000 14-44 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

Transformers: Dry Type Cast Coil Type = Cast Coil Primary Volts = 2400-13800 Sec_Volts = 208-600 Temperature Rise = 80/115C for Both Aluminum & Copper Windings Standard kv BIL (HV/LV) = 60/30 for Aluminum Windings, 95/30 for Copper Windings Table 2 Low Voltage Switchgear or Switchboard Coordination Winding Material KVA Height (Inches) Width (Inches) Depth (Inches) Weight (Pounds) Aluminum 300 90 90 54 5500 Aluminum 500 90 90 54 6300 Aluminum 750 90 96 60 7800 Aluminum 1000 96 102 60 9500 Aluminum 1500 102 108 60 11500 Aluminum 2000 108 112 60 13800 Aluminum 2500 112 126 60 16200 Aluminum 3000 118 132 60 19200 Aluminum 3750 126 138 66 25000 Aluminum 5000 132 144 66 28000 Copper 300 90 90 60 6200 Copper 500 90 96 60 7000 Copper 750 90 102 60 9100 Copper 1000 96 112 60 10600 Copper 1500 102 118 60 14300 Copper 2000 108 118 66 18200 Copper 2500 118 126 66 19500 Copper 3000 126 132 66 23500 Copper 3750 126 144 66 28000 Copper 5000 132 160 66 35000 14 SWITCHGEAR Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog 14-45

Transformers: Liquid Filled Type Top view Elevation H G 8 J H 3 H 2 H 1 X 3 X 2 X 1 X 0 C D E F A SWITCHGEAR 14 B Unit Type Substation Transformer Primary Volts = 25kV and below, Secondary Voltage = 5kV and below Table 3 Liquid-Filled 55/65 C Rise Aluminum Windings Copper Windings Drawing Dimensions (in.) kva A B C D E F G H J Gallons Of Fluid Approx. Total Weight (lbs.) (With Fluid) Gallons Of Fluid Approx. Total Weight (lbs.) (With Fluid) 500 66 51 26 52 45 45 30 60 35 300 5600 310 5900 750 75 59 26 52 55 55 34 68 35 360 7000 370 7400 1000 75 67 26 52 55 55 38 76 35 420 8400 430 8800 1500 75 59 59 80 55 55 34 68 35 400 9500 420 10000 2000 85 67 67 90 55 55 38 76 39 520 12000 500 12800 2500 85 75 68 92 55 55 42 84 41 570 14600 590 14900 3750 85 75 70 120 65 65 42 84 45 790 20500 830 21500 5000 99 87 72 144 65 65 48 96 49 1050 26000 1090 28000 7500 99 95 74 148 75 75 52 104 53 1320 35000 1360 37000 10,000 99 103 76 152 75 75 56 112 57 1740 43000 1780 45000 12,000 99 103 82 164 75 75 56 112 61 1850 49000 1880 50000 Weights, gallons of fluid and dimensions are for reference only, and not for construction. Please contact Siemens Industry Inc. for exact dimensions 14-46 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

Type WL Low Voltage Switchgear Substation Secondaries Siemens type WL low-voltage, metalenclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of the type WL low voltage switchgear is the world class Siemens type WL breaker. Siemens type WL low-voltage switchgear can be utilized in the following applications: n Industrial n Institutional n Critical power n Utility and co-generation n Commercial. Product Scope n Equipment ratings: 635 Vac maximum Three-phase, three-wire Three-phase, four-wire 50/60 Hz 6,000 A maximum horizontal bus 5,000 A maximum vertical bus. n Enclosure options: NEMA 1 indoor NEMA 3R outdoor walk-in NEMA 3R outdoor non walk-in. 14 SWITCHGEAR Exclusive features Generator/utility protection sets 24/7/365 power availability is critical for some systems. On-site generation capabilities are becoming more and more common. Type WL digital electronic trip units allow the system designer to precisely tailor trip settings for the most demanding requirements. The Siemens type WL 776 trip unit allows one set of trip settings for a fully loaded utility feed and, with a simple contact closure, the trip unit toggles to a second trip set tailored to provide optimal generator protection. The wide range of settings allows the type WL to provide protection for a minimal generator capacity for only essential loads, through full backup for an entire facility. This dual utility/generator protection capability in a single circuit breaker allows the system designer unparalleled, cost effective flexibility. For more information, visit our web site at: www.usa.siemens.com/switchgear. Extended instantaneous protection (EIP) This patent pending type WL trip unit feature allows the system designer to achieve full selective trip coordination up to the short-time rating of the frame, while also allowing application of the circuit breaker up to the interrupting rating of the frame. EIP allows the type WL breaker to be applied up to the full withstand rating of the circuit breaker, for complete coordination, with a minus 0% short-time band tolerance up to 85 ka on Frame Size II and 100 ka on Frame Size III. Above fault currents of 20-percent higher than the full short-time rating, the type WL circuit breaker is self-protecting, and the EIP function will trip the circuit breaker instantly to protect the frame and the system from these extremely high currents (as high as 150 ka on Frame Size III). An added benefit is that arc flash energy is greatly reduced in this high- current region due to EIP s instantaneous trip response. Industry standards Type WL switchgear with power circuit breakers are designed, tested and constructed in accordance with: n UL 1558 Metal-Enclosed Low- Voltage Power Circuit Breaker Switchgear n ANSI C37.20.1 Metal-Enclosed Low- Voltage Power Circuit Breaker Switchgear. Type WL drawout circuit breakers are designed for continuous operation at 100-percent of their current rating without the need for external heat sinks, and are in accordance with: n UL 1066 Low-Voltage AC and DC Power Circuit Breakers Used in Enclosures n ANSI C37.13 Low-Voltage AC Power Circuit Breakers Used in Enclosures. Switchgear Secondary Note: See Pages 14-52 to 14-61 for complete details concerning WL Low Voltage Switchgear unit substation secondaries. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog 14-47

Switchboard Substation Secondaries 14 SWITCHGEAR Product Overview Siemens modular front connected switchboard design provides a broad range of features and capabilities for a wide range of applications. Every aspect of design of Siemens switchboards has been aimed at improving layout convenience, reducing installation costs and minimizing the impact and cost of changes to the system. Siemens switchboards provide a rugged design and the flexibility necessary in electrical systems for all types of applications, some examples are: n Industrial plants n High-rise complexes n Hospitals n Commercial buildings Standards and Certifications Siemens switchboards are designed, tested and constructed in accordance with: n UL891 Switchboards n NEMA PB-2 n Seismially qualified n Other equipment is UL listed as applicable Features & Benefits Siemens switchboards ratings and features include: n Up to 6000 ampere main bus rating n Up to 600 volts AC n Bus bracing up to 200KAIC n Copper or aluminum bussing n Temperature or density rated bussing n Type 1 and Type 3R enclosures n Main and branch circuit breakers and fusible switches n Thermal magnetic and solid state circuit breakers n Surge protective devices n Utility metering provisions n ACCESS power monitoring on mains and branches n Ground fault protection on mains and branches n Busway and transformer connections n Protective relaying n Two and three device autothrowover scheme Further Switchboard Information See Section 13 for complete details concerning SB3 front-connected switchboard unit substation secondaries. 14-48 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

Indoor Dry Type Transformer Sketch Page Plan view 38.0 38.0 Transformer 2 D Top and bottom conduit 58.0 48.4 1 19.7 W Restricted Area 14 SWITCHGEAR Front view 19.7" (500 mm) 38" (965 mm) 38" (965 mm) Type SB3 switchboard digital meter type SPD module Unit space 100.4" (2,550 mm) 90" (2,286 mm) Section #1 Section #2 Primary Switch requires front access for top cable entry terminations. Transformer requires access from the front and 12 (305 mm) on the back side for ventilation space. Primary lug location See page 5 for transformer dimensions. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog 14-49

Indoor Liquid Filled Transformer Sketch Page Plan view 32.0 (813 mm) 22.0 (559 mm) 22.0 (559 mm) 14 SWITCHGEAR D 48.4 (1,229 mm) 1 19.7 (500 mm) H3 H2 H1 Transformer 2 X3 X2 X1 X0 Maximum available space in top or bottom for customer's cables. 31.5 (800 mm) Space for secondary leads from above. Space for secondary leads from below. Maximum available space in top or bottom for customer's cables. 31.5 (800 mm) Space for secondary leads from above. Space for secondary leads from below. Maximum available space in top or bottom for customer's cables. 31.5 (800 mm) Space for secondary leads from above. Space for secondary leads from below. 70.0 (1,778 mm) Front view 32.0 (813 mm) 22.0 (559 mm) 22.0 (559 mm) W Metering/SPD Main breaker 100.4 (2,550 mm) Liquid filled transformer 102.2 (2,596 mm) Section #1 Section #2 Section #3 Primary Switch Primary requires Switch front requires access front for access top cable for top entry cable entry terminations. terminations. Transformer requires access from the front and 12" (305 mm) on the back side for ventilation space. Transformer requires access from the front and 12 (305 mm) on the back side for ventilation space. Primary lug locations. See page 6 for transformer dimensions. 14-50 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

Outdoor Liquid Type Transformer Sketch Page Plan view 42.7 (1,085 mm) 59.9 (1,521 mm) 1 H3 H2 H1 H3 H2 H1 D X0 X1 X2 X3 Low voltage switchgear 124.0 (3,150 mm) Allow 6 clearance for door swing Door Walk-in aisle Door 14 SWITCHGEAR Front view W 76.8 (1,951 mm) 30.2 (767 mm) Liquid filled 2 transformer 103.1 (2,619 mm) Outdoor type SIMOSEC switch 113.9 (2,893 mm) Section #1 Section #2 Section #3 Primary lug locations. See page 6 for transformer dimensions. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog 14-51