Split units TH with hermetic compressors

Similar documents
Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Appendix - Controllers 179


ECOCIAT. Domestic hot water heat recovery unit

Technical data. Danfoss DHP-A

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

IV. Rear Mount System

Hot Water. Heat pump water heaters. Residential and Commercial R410a

AIR-CONDITIONER SPLIT TYPE

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Installation, operation and maintenance manual TX 35A

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Octopus for a sustainable future

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

GENERAL INFORMATION FOR REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONING PLANT ( Direct & Chiller ).

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Air Conditioners Technical Data

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

york air-conditioning products Residential & VRF News 2015

Voltage Current volume. 24 V DC 4.5 A 330 m 3 /hr 3000 W W

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

Solenoid valves Type EVU

SECTION MORTUARY REFRIGERATORS

The natural ombination

Daikin Altherma hybrid heat pump. The natural combination

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

Refrigeration Compressed Air Dryer Buran Ultrapulse

ECO-AIR AIR CONDITIONING

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

Engineering Specifications

LOCAL AIR-CONDITIONERS

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

AIR CONDITIONER INSTALLATION MANUAL

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

NEW 3-PIPE ECOi MF2 SERIES

Measurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler

Adsorption air dryers ADS 1 215

Air Conditioners Technical Data

Split System Cooling Product Data

HP switch LP switch Discharge thermo Comp. Surface thermo

Dehumidifier D 850E. - Instruction manual version 02

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Failure code manual. content

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

Installation & operating instructions

Cooling kw Heating kw

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

Technical Service Manual. Version One

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

Air Conditioning System

Low Profile Unit Cooler

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

FTQ. Daikin Inverter Ducted Heat Pump

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Split System Heat Pump Product Data

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Unico Inverter. Unique and efficient.

TWE+TTA TWE+TWA T.R.

Versati Air to Water Heat Pump

SWIMMING POOL HEAT PUMP Owners Manual

marine/bespoke split applications

In Row Cooling Options for High Density IT Applications

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

A brief explanation on how air conditioning works and what terms mean

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

FULL DC INVERTER SYSTEMS

Conlift1, Conlift2, Conlift2 ph+

innovative comfort solutions

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Lesson 36 Selection Of Air Conditioning Systems

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Solar Hot Water Heaters

Transcription:

Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split units series THM Temperature range for normal refrigeration: 5 C / +12 C Split units series THL Temperature range for deep freezing: 15 C / 25 C General features Self supporting sound insulated weatherproof housing R404A or R134a Remote control panel Hermetic compressors with thermic protection Evaporator as Cu/Alu finned heat exchanger Air cooled or water cooled condenser Expansion with capillary tube Programmable automatic defrosting Condensing water direct discharge incl. heating Winter controller Refrigerant charge for devices with screw terminals Nitrogen gas for devices with solder terminals Options Door contact switch Cold room light Different voltage Master/Slave Function Data gathering and remote control CE approval PED conformity TÜF certification Cooling capacity calculation basis series THM Cooling capacity calculation basis series THL Cold room insulation: 80 mm (100 mm from THM 470) Product entering temperature: +25 C Product cooling time per day: 18 St. Load density: 250 Kg/m³ Product daily turnover: 10% Product specific heat (meat): 3,22 J/Kg C Cold room insulation: 100 mm (120 mm from THL 300) Product entering temperature: 7 C Product cooling time per day: 18 St. Load density: 250 Kg/m³ Product daily turnover: 10% Product specific heat (meat): 3,22 J/Kg C Seite 1

Refrigerant: R404A Sound insulated weatherproof housing for outdoor installation Remote control panel with 10 m long cable Screw or solder terminals Evaporator THM 80 THM 100 THM 120 THM 150 THM 170 1A 1A 1B 1B 1B 569 2,96 654 3,44 853 4,18 911 4,24 1078 5,01 Compressor Power kw 0,295 0,370 0,370 0,440 0,735 Condenser 1945 1945 1945 1699 1699 Evaporator Air throw m Expansion 1 x 200 630 3 1 x 200 630 3 2 x 200 1230 3,5 2 x 200 1230 3,5 2 x 200 1230 3,5 33 33 33 35 36 61 63 66 77 78 Construction type Electrical values Voltage Volt / Ph / Hz Input W Current consumption A Sound level dba 10 m (*) Pressure/Suction line Ø mm Kind of defrosting Weight Kg Cooling capacity W Cooling capacity m³ 967 / 844 / 721 1167 / 1023 / 878 1392 / 1230 / 1022 1743 / 1519 / 1233 1992 / 1748 / 1415 807 / 704 / 600 963 / 846 / 727 1136 / 1006 / 842 1449 / 1262 / 1028 1660 / 1458 / 1191 8,0 / 5,1 / 4,1 10,5 / 6,8 / 5,3 13,4 / 8,9 / 6,7 17,9 / 11,8 / 8,7 21,3 / 14,2 / 10,5 5,8 / 3,7 / 3,1 7,5 / 4,8 / 3,9 9,5 / 6,2 / 4,8 13,1 / 8,6 / 6,4 15,6 / 10,4 / 7,8 (*) These values relate only to the condensing unit Optional items A2 Pre charged connection pipe 2,5 m A5 Pre charged connection pipe 5 m A10 Pre charged connection pipe 10 m A15 Pre charged connection pipe 15 m AB Connection piece for refrigerant lines AC Brackets for wall mounting AD Oil separator B Model with R134a C Different voltage L Voltage monitor M Differential thermomagnetic switch N Master/Slave Function O Data gathering and remote control Seite 2

Illustrations and dimensions Seite 3

Refrigerant: R404A Sound insulated weatherproof housing for outdoor installation Remote control panel with 10 m long cable Screw or solder terminals Evaporator THM 200 THM 250 THM 340 THM 370 1B 2A 2B 2B 1303 5,94 1433 6,89 1904 5,18 2029 5,32 Compressor Power kw 0,825 0,920 1,100 1,470 Condenser 1 x 400 2734 1 x 400 2734 1 x 400 2580 1 x 400 2580 Evaporator Air throw m Expansion 2 x 200 1170 3,5 2 x 250 1602 7,5 3 x 250 2364 7,5 3 x 250 2364 7,5 38 40 41 42 96 103 117 124 Construction type Electrical values Voltage Volt / Ph / Hz Input W Current consumption A Sound level dba 10 m (*) Pressure/Suction line Ø mm Kind of defrosting Weight Kg Cooling capacity W Cooling capacity m³ 2628 / 2261 / 1895 2907 / 2527 / 2156 3923 / 3410 / 2898 4339 / 3777 / 3224 2209 / 1895 / 1582 2448 / 2126 / 1811 3277 / 2850 / 2421 3581 / 3090 / 2601 30,6 / 19,9 / 15,6 34,8 / 22,9 / 18,2 50,8 / 33,7 / 26,8 57,3 / 38,2 / 30,5 22,6 / 14,6 / 11,4 25,8 / 17,0 / 13,6 37,5 / 24,8 / 19,7 41,8 / 27,5 / 21,6 (*) These values relate only to the condensing unit Optional items A2 Pre charged connection pipe 2,5 m A5 Pre charged connection pipe 5 m A10 Pre charged connection pipe 10 m A15 Pre charged connection pipe 15 m AB Connection piece for refrigerant lines AC Brackets for wall mounting AD Oil separator B Model with R134a C Different voltage L Voltage monitor M Differential thermomagnetic switch N Master/Slave Function O Data gathering and remote control Seite 4

Illustrations and dimensions Seite 5

Refrigerant: R404A Sound insulated weatherproof housing for outdoor installation Remote control panel with 10 m long cable Solder terminals Evaporator THM 470 THM 600 2B 2C 2579 6,16 3411 8,91 Compressor Power kw 1,840 2,200 Condenser 1 x 450 4266 1 x 450 4031 Evaporator Air throw m Expansion 3 x 250 2167 7 4 x 250 2890 7 45 48 10 / 22 10 / 22 138 155 Construction type Electrical values Voltage Volt / Ph / Hz Input W Current consumption A Sound level dba 10 m (*) Pressure/Suction line Ø mm Kind of defrosting Weight Kg Cooling capacity W Cooling capacity m³ 5474 / 4752 / 4023 7151 / 6337 / 5546 4537 / 3910 / 3273 5857 / 5135 / 4421 75,3 / 50,8 / 40,1 104 / 78,9 / 62,6 55,6 / 36,8 / 28,7 75,1 / 54,4 / 42,9 (*) These values relate only to the condensing unit Optional items L Voltage monitor M Differential thermomagnetic switch N Master/Slave Function O Data gathering and remote control AC Brackets for wall mounting AD Oil separator B Model with R134a C Different voltage Seite 6

Illustrations and dimensions Seite 7

Refrigerant: R404A Sound insulated weatherproof housing for outdoor installation Remote control panel with 10 m long cable Solder terminals Evaporator THM 730 THM 880 THM 1000 3A 3B 3C 3775 8,41 4507 10,10 5223 11,59 Compressor Power kw 3,310 3,675 4,410 Condenser 2 x 450 7906 2 x 450 7906 2 x 450 7125 Evaporator Air throw m Expansion 3 x 350 4078 13,9 3 x 350 5990 16,2 4 x 350 7987 20,7 52 53 53 12 / 22 12 / 28 12 / 28 188 202 226 Construction type Electrical values Voltage Volt / Ph / Hz Input W Current consumption A Sound level dba 10 m (*) Pressure/Suction line Ø mm Kind of defrosting Weight Kg Cooling capacity W Cooling capacity m³ 8470 / 7313 / 6177 10138 / 8840 / 7596 11973 / 10536 / 9175 7000 / 5979 / 4975 8285 / 7148 / 6050 9731 / 8472 / 7267 127 / 95,2 / 75 157 / 118 / 94,5 190 / 144 / 115 93,3 / 68,4 / 50,5 113 / 84,4 / 67,1 136 / 102 / 80,6 (*) These values relate only to the condensing unit Optional items L Voltage monitor M Differential thermomagnetic switch N Master/Slave Function O Data gathering and remote control AC Brackets for wall mounting AD Oil separator B Model with R134a C Different voltage Seite 8

Illustrations and dimensions Seite 9

Split units THL 15 / 25 C Refrigerant: R404A Sound insulated weatherproof housing for outdoor installation Remote control panel with 10 m long cable Screw or solder terminals Evaporator THL 45 THL 50 THL 58 THL 88 THL 100 1A 1A 1A 1A 1B 574 3,63 665 4,11 710 3,41 1059 4,95 1415 6,62 Compressor Power kw 0,370 0,440 0,550 0,735 1,100 Condenser 1945 1945 1945 1699 1699 Evaporator Air throw m Expansion 1 x 200 630 3 1 x 200 630 3 1 x 200 630 3 1 x 200 600 3 3 x 200 684 3,5 31 33 34 38 40 61 69 70 74 78 566 / 479 / 397 617 / 511 / 414 707 / 589 / 478 1061 / 885 / 723 1339 / 1119 / 913 445 / 372 / 303 487 / 400 / 319 561 / 463 / 371 865 / 717 / 580 1086 / 906 / 735 3,1 / 2,4 / 1,5 3,3 / 2,5 / 1,5 4,0 / 3,0 / 1,9 7,2 / 5,7 / 3,8 10,6 / 8,4 / 5,6 2,1 / 1,6 / 1,1 2,3 / 1,7 / 1,1 2,8 / 2,0 / 1,4 4,9 / 3,7 / 2,4 7,2 / 5,6 / 3,7 Construction type Electrical values Voltage Volt / Ph / Hz Input W Current consumption A Sound level dba 10 m (*) Pressure/Suction line Ø mm Kind of defrosting Weight Kg Cooling capacity W Cooling capacity m³ (*) These values relate only to the condensing unit Optional items A2 Pre charged connection pipe 2,5 m A5 Pre charged connection pipe 5 m A10 Pre charged connection pipe 10 m A15 Pre charged connection pipe 15 m AB Connection piece for refrigerant lines AC Brackets for wall mounting AD Oil separator C Different voltage L Voltage monitor M Differential thermomagnetic switch N Master/Slave Function O Data gathering and remote control Seite 10

Split units THL 15 / 25 C Illustrations and dimensions Seite 11

Split units THL 15 / 25 C Refrigerant: R404A Sound insulated weatherproof housing for outdoor installation Remote control panel with 10 m long cable Solder terminals Evaporator THL 150 THL 230 2A 2B 1969 4,23 2397 5,41 Compressor Power kw 1,470 2,200 Condenser 1 x 400 2734 1 x 400 2734 Evaporator Air throw m Expansion 2 x 250 1602 7,5 3 x 250 2364 7,5 41 42 115 123 Construction type Electrical values Voltage Volt / Ph / Hz Input W Current consumption A Sound level dba 10 m (*) Pressure/Suction line Ø mm Kind of defrosting Weight Kg Cooling capacity W Cooling capacity m³ 1945 / 1590 / 1261 2724 / 2309 / 1947 1565 / 1267 / 993 2148 / 1796 / 1484 19,6 / 15,1 / 9,5 33,5 / 27,7 / 19,5 13,1 / 10,0 / 6,2 22,1 / 17,9 / 12,2 (*) These values relate only to the condensing unit Optional items A2 Pre charged connection pipe 2,5 m A5 Pre charged connection pipe 5 m A10 Pre charged connection pipe 10 m A15 Pre charged connection pipe 15 m AB Connection piece for refrigerant lines AC Brackets for wall mounting AD Oil separator C Different voltage L Voltage monitor M Differential thermomagnetic switch N Master/Slave Function O Data gathering and remote control Seite 12

Split units THL 15 / 25 C Illustrations and dimensions Seite 13

Split units THL 15 / 25 C Refrigerant: R404A Sound insulated weatherproof housing for outdoor installation Remote control panel with 10 m long cable Solder terminals Evaporator THL 300 THL 380 2B 2C 3357 7,08 4054 9,08 Compressor Power kw 2,940 3,675 Condenser 1 x 450 4266 1 x 450 4266 Evaporator Air throw m Expansion 3 x 250 2167 7 4 x 250 2890 7 45 46 12 / 22 12 / 22 152 164 Construction type Electrical values Voltage Volt / Ph / Hz Input W Current consumption A Sound level dba 10 m (*) Pressure/Suction line Ø mm Kind of defrosting Weight Kg Cooling capacity W Cooling capacity m³ 3631 / 3019 / 2482 4567 / 3870 / 3257 2925 / 2411 / 1956 3587 / 3009 / 2491 52 / 41,3 / 28 73,8 / 63,6 / 42,2 35,3 / 27,9 / 18,6 48,4 / 38,8 / 26,8 (*) These values relate only to the condensing unit Optional items M Differential thermomagnetic switch N Master/Slave Function O Data gathering and remote control AC Brackets for wall mounting AD Oil separator C Different voltage L Voltage monitor Seite 14

Split units THL 15 / 25 C Illustrations and dimensions Seite 15