A1.5 Classroom Standards



Similar documents
VIDEO CONFERENCING ROOM DESCRIPTION AND REQUIREMENTS INDIANA UNIVERSITY, BLOOMINGTON Indiana University DEFINITION

Electrical. This section applies to the design and installation of building power distribution systems.

Videoconferencing Room Guide

RESOURCES. Telehealth. Provincial Health Services Authority. Telehealth & General Meeting Room Design Requirements

Element Z General Design Requirements Owner Standards and Other Requirements

D E F I N E V E L O D O. Telemedicine Room Design PROGRAM GUIDE. CTEConline.org

Appendix 3H A/V and Video Conferencing Standard

Design an Effective TRAINING SPACE. White Paper

B R O W N U N I V E R S I T Y

Guidelines for Technology Classroom Design

A/V and Video Conference Standards for Teaching and Learning Rooms.

Laboratory Construction Guidelines Vicon MX Systems

PROJECT WORKPLACE DEVELOPMENT

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

How To Build A Large Room For A Conference

Provincial Health Services Authority. Telehealth Room Preparation Generic Guidelines

CTC-AV-2 General AV Design Guidelines

Technical Report An Analysis on the Use of LED Lighting for Video Conferencing

Equipment Guide Human Resources Training Room Suite 205, Building 3377

Reference Design. conference rooms

Nursing School Classroom Technology Tips

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

Classroom Design Guide

Open Office Plan. Function and Orientation. Space Characteristics. Material Properties Gregory Wolfe 2004 Senior Thesis Lighting / Electrical

Revised RFP submission schedule October 15 th 3:00 PM EST Last Day to Submit Questions October 30 th 3:00 PM EST Proposals Due

2D & 3D TelePresence

COMPUTER LAB CLASSROOMS. A Planning Guide

Design Guidance: Learning Environments

Engineers Edge, LLC PDH & Professional Training

EXHIBITION DISPLAY RULES

CEDIA Electronic Lifestyles Awards Program Home Technology Professional Categories Technical Criteria for Judging

Fire Alarm System Plans Review Checklist Property location Date of Review

Policy Title-Aquia Data Center Operational Policy & Procedure. Policy ID - TSD-ADC001. Version - Version: 1.0. Supersedes Version 1.

Occupancy: Assembly (A-3) and Business -Includes offices, seminar rooms, classrooms, and café facility. Duke University Medical School

Current as of 11/10/08 1 of 1

Lutron Linear Recessed and Video Conference Fixture Solutions

OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED

Media Technology Services Classroom Equipment Guide

Guide to new, energy-efficient lighting technologies for your business

Lutron Linear Recessed and Video Conference Fixture Solutions

AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

CLASSROOM TECHNOLOGY GUIDE

Main Library Meeting Room Use

Lighting Control in the Office Space

Media Technology Services Classroom Equipment Guide

Telepresence T3 Room recommendations

GENERAL WIRING RULES FOR HOUSES

in other campus buildings and at remote campus locations. This outage would include Internet access at the main campus.

SERC Audio Visual Options

Instructional Technology & Distance Education

INTERIOR CONCEPTS Contact Center

Emory College Classroom Design Guide

2012 BIM Guidelines and Standards (Rev. 00) University at Albany

Audiovisual Design Standards. October Audiovisual Design Standards (July, 2011)

Production analogue video fed to Granicus encoder currently place Phase 3 will provide digital audio video to Granicus encoder

SOUND CENTRAL CONTROL. Conferencing Facilities. Video Conferencing Video Conferencing Lighting Large Display Multi Signal Matrix Sound Central Control

62% 40% 96% 90% 77% 40%

United States District Court District of Minnesota. Courtroom Technology Minneapolis

Facilities and Equipment

C-Bus Solutions. Complete commercial control. Make the most of your energy SM

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

LCD/LED Displays and Projectors

DVI DA2 and DVI DA 4 User Guide

Lighting Requirements

Lighting Management solutions

Sustainable Office Design (SOD) is different than existing programs STEP 1: STEP 2: STEP 3: STEP 4:

Wentz Concert Hall and Fine Arts Center 171 E. Chicago Avenue Naperville, IL Existing Electrical Systems Will Lesieutre

Data Center Operational Policy

Financial Bid Format(All Inclusive)

the audio/video + lighting menu

University of California, San Diego CAL IT 2

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Visual Tutorial Basic Edition 1. Visual. Basic Edition Tutorial.

REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations

Automatic Door Selection Guide

AODA. Accessibility for Ontarians with Disabilities Act. Guide to Accessible Events

H107 Video Conference Room

Electrical Wiring Technical Bulletin

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

Exhibit Display Rules and Regulations

AVR 158. Audio/video receiver. Quick-Start Guide ENGLISH

Audio/Visual System User Operations Manual 100 Seat Lecture Hall Enhanced

Video-conferencing: Overall

Conferences Meetings Special Events. Events and Conference Services. Your Event. Your Way. mtroyal.ca/mrevents

Transcription:

A1.5 Classroom Standards Note: The following standards have been developed and adopted by KU's Instructional and Mediated Spaces Committee (IMSAC), which includes representatives from DCM, Instructional Development & Support (IDS) and other campus offices. Note: These standards were updated in their entirety May 2008. General Classroom Characteristics 1) Location a) Classrooms should be concentrated on the entry levels of buildings to provide easy access for students and equipment. b) Classrooms should be located away from noise generators, such as mechanical rooms or student gathering places. c) For classrooms that need to be darkened, windows which face south, east and west require a higher degree of blackout capability than do north-facing windows. 2) Size a) Typically designed with 20 to 25 square foot per student, to accommodate the programmed number of occupants with: i) Approximately 20 SF/student for moveable seating ii) Approximately 10 SF/student for fixed seating iii) Approximately 20 SF/student for conference table seating b) Ceiling should have an average height of not less than 9', and allow for a projection screen large enough to display images of adequate size, and placed high enough off the floor to provide unobstructed sight lines. 3) Orientation a) The major entry should be at the rear of the room. b) Windows should be on the sides of classrooms, not at the front or back. 4) All classrooms shall comply with the American with Disabilities Act. 5) Audio-visual accommodations a) Support space must allow for the setup and use of audio-visual equipment. b) Classroom design shall consider present and future instructional technology c) Design shall focus on ease of use and effective instructional practice Revision Date: May 21, 2008 Page 1 of 7

Classroom Surfaces and Finishes 1) The following are the standard materials that shall be used, unless other alternative materials are specifically approved by the DCM Project Manager and DCM Director. 2) Walls: a) Acoustical treatment, using fabric-covered acoustical panels to create an NC rating between 20 and 30. b) Chair rails should be installed on the back wall 25" to 33" above the floor, wherever moveable seating is used. 3) Floor: a) Vinyl composition tile, unless existing finished concrete floor or carpet is acceptable. b) Aisle areas and the area at the front of the room may be carpeted; no carpeting shall be installed under fixed seating. c) Coverings should be of a medium to light color, with some pattern. 4) Ceiling: i) Ceilings should be light in color and made of non-reflective material. ii) Standard tile is Armstrong World Industries, Inc., Product #755, 2'x4' panel. iii) Standard grid shall be Chicago Metallic Corp., Product #250 Fire Front System; Color: White. 5) Doors: a) Doors should be a minimum of 36" wide with a 32" clear opening. b) Doors should have a glass panel no more than 100 square inches. c) Doors should have no ventilation louvers because of noise distractions. Classroom Fixtures and Furniture 1) Marker boards a) Matte white to reduce problems with glare b) Minimum Size (can be increased to meet specific departmental needs): i) 12 foot long X 4 foot high for rooms seating 24 or fewer ii) 18 foot long X 4 foot high for rooms seating 25 to 75 iii) Designed for the room, for rooms seating 76 or more c) Marker boards shall be provided with a full width tray and map rail with cork insert d) Marker boards shall be placed so they can be used when the projection screen is in use. Revision Date: May 21, 2008 Page 2 of 7

2) Projection screen a) Screen size will be determined by IDS based on room size, ambient light, viewing angles, ceiling height, etc. Consideration will be given to installing screens that will accommodate upcoming changes in video aspect ratio (i.e., for high definition display). b) Screens larger than 96 will include motorized controls; all others will be manual pull-down style. c) Consideration should be given to screen placement to maximize marker board use d) Screens shall be installed to allow the lowest side of the projected image to be at least 4 above the floor. 3) Seating a) Moveable seating, either tables and chairs, or tablet-arm chairs, are recommended for rooms seating 48 or fewer. b) Fixed tables and chairs are recommended for rooms seating 60 or more. c) Tiered floors should be provided in rooms seating 75 or more. d) Side chairs should be provided for lecturers and guests. e) The distance between the projection screen and the first row of seats should be at least two times the width of the projected image, and the distance between the screen and the last row of seats should be at most eight times the width of the projected image. f) Tablet-arm chairs or fixed seating should have a minimum of 10% of the seats accommodating left handed students. g) Tablet-arms should provide a minimum of 150 square inches of working surface. 4) Instructor's station, or table and lectern, or podium a) Width: 48 to 58 b) Depth: 24 to 30 c) Maximum height to tabletop: 28 5) Light-blocking window blinds set in channels shall be provided where windows exist (Opaque drapes with cord tighteners or blackout shades by special request). 6) Manual pencil sharpener located by the entry. 7) Waste receptacle located by the entry. Classroom Mechanical Systems (HVAC) 1) Temperature controls a) Provide in accordance with other KU Design Standards and KU Energy policies. Revision Date: May 21, 2008 Page 3 of 7

b) Temperature controls should not be accessible to room occupants. 2) Ventilation a) Adequate ventilation to allow for 4 to 6 air changes per hour. b) If possible, air circulation system should be capable of being used independently of the heating and air-conditioning systems. c) Windows in classrooms that seat 75 or fewer should be operable. Classroom Lighting Systems 1) Lighting shall be designed to create a variety of zones within each classroom of 24 or more, as follows: a) Overall light for the classroom. b) Note-taking, controlled lighting that only illuminates the seating area of the classroom. c) Lighting for the markerboard area. d) Lighting for the instructor's station. 2) Lighting levels a) Ability to provide a minimum of 30 foot candles on writing surfaces. b) Ability to reduce general overall lighting by 50% for note taking during media presentations, with no light on the projection screen. Ability to further dim to 5%. c) Seating areas shall be lighted so that 100% of the lamps are on, or 50% of the lamps are on and those lamps are dimmable to 5%. d) Note taking light levels must be designed to avoid washing out visually projected images. 3) Lighting controls a) The lighting controls shall be uniform, from classroom to classroom within each building. b) All light switches shall be clustered, simple to use, with clearly labeled functions on the switch plates. c) Controls for the some of the room lighting should be located near the major entrance doors, and duplicated near the presentation area. d) Controls for note taking and presentation area lighting shall be adjacent to the presentation area. e) Motion sensors shall be used to shut off classroom lighting during prolonged unoccupied periods. 4) Light fixtures a) Unless the room architecture indicates otherwise, 2' x 4' lay-in troffer 2, 3, or 4- lamp fluorescent fixtures shall be used. Revision Date: May 21, 2008 Page 4 of 7

b) Light fixtures shall have electronic ballasts. c) Generally fixtures shall have acrylic diffusers, however, fixtures in rooms with monitors shall have parabolic diffusers to minimize glare on the screens. d) Recessed incandescent lighting should be used for special applications or purposes only, such as side and back border lighting and note taking in media classrooms. Classroom Electrical Systems 1) Conduit a) Low voltage cables (e.g. audio, video, and control cables) are all required to run in a separate conduit from any AC wiring. 2) Circuits a) As much as possible, audio, video, and control electrical circuits should be fed from "clean" legs from the transformer free of high inductive loads. To the extent possible, there should be no elevator motors, compressor motors, blower motors, or other electrical devices on the side of the power transformer that feeds the media equipment. b) All electrical control circuits should come to a single location, convenient for maintenance and secure from vandalism. 3) Outlets a) Utility AC outlets on separate circuits from the media equipment circuits should be provided inside the classroom for overhead projectors, vacuum cleaners, etc. b) There should be at least one duplex outlet on each wall. In rooms with tiered seating, an outlet should be provided in the face of the first riser and on the face of a riser mid-way back in the middle of the seating, both centered in the room. c) Wall outlets should be positioned 18" above the floor. d) Power and audio/video outlets should be mounted on vertical surfaces rather than a tabletop or the floor to avoid the intrusion of water and debris. e) AC outlets shall be provided near or on the ceiling for rooms with monitors. 4) Minimum electronic services to be provided in classrooms: a) Classrooms seating 24 students or fewer shall have: i) Dual duplex data outlets at the front of the classroom. b) Classrooms seating between 25 and 75 students shall have: i) Dual duplex data outlets at the front of the classroom and at all audio-visual equipment locations. ii) Outlets to accommodate portable and/or installed media equipment. Revision Date: May 21, 2008 Page 5 of 7

Classroom Audio-Visual Systems 1) Rooms with an installed data projector shall have the screen installed diagonally in a corner, whenever possible, to avoid blocking the marker boards. 2) Data connections for a computer and remote monitoring system should be included. 3) Instructional media equipment installed in any classroom space shall conform to campus standards and be approved by IDS. Standard Equipment and Technological Capabilities in Classrooms KU has four categories of classrooms (excepting class labs): Interactive Television Full Media Media Lite Basic 1) Interactive Television Connect to one or more remote sites via Internet for real-time audio/video interaction Display graphics, text, motion media (DVD/VHS) or 3D objects to local / remote sites Play audio CD s for local and remote sites Display output from installed or instructor-provided computer (Mac or PC) to local and remote sites Computer (PC with internal CD player) Network connection for installed or instructor-provided computer (Mac and PC) Ceiling-mounted data projector Document camera DVD/VHS video player Audio speakers Instructor and student microphones Instructor and student video cameras Codec (and integrated components) for multi-site video connectivity 2) Full Media Display graphics, text, motion media (DVD/VHS), or 3D objects Play audio CD s Display output (including Internet sites) from installed or instructor-provided computer (Mac or PC) Student response system (clickers), upon request Revision Date: May 21, 2008 Page 6 of 7

Computer (PC with internal CD player) Network connection for installed or instructor-provided computer (Mac and PC) Ceiling-mounted data projector Document camera DVD/VHS video player Audio speakers Overhead (transparency) projector Note: All classrooms designated as auditoria are equipped as Full Media teaching environments. 3) Media Lite Display output (including Internet sites) from instructor-provided computer (Mac or PC) Display motion media (DVD/VHS) Display transparencies Student response system (clickers), upon request Network connections for instructor-provided computer (Mac and PC) Ceiling-mounted data projector DVD/VHS video player Audio speakers Overhead (transparency) projector Note: When available, a document camera may be installed temporarily in a Media Lite room upon request, to provide large-format display of 3-D objects, for example. 4) Basic Display motion media (DVD/VHS) Display transparencies DVD/VHS video player and monitor Overhead (transparency) projector Note: Portable data projection is available for all Basic classrooms, to provide largeformat display of computer output from an instructor-provided laptop. *** End of Document C:\_Steve-Temp\Design Stds\Stds_sas-smz_Div-01_A5_final-draft.doc *** Revision Date: May 21, 2008 Page 7 of 7