ENGINEERING COMMITTEE Construction and Maintenance Subcommittee



Similar documents
ENGINEERING COMMITTEE

ENGINEERING COMMITTEE Energy Management Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

CADDSTAR V7.0 FEATURES AND FUNCTIONALITY

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

AMERICAN NATIONAL STANDARD

Cable 101. A Broadband Telecommunications Primer for Non-technical Personnel

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

Management of Converging Networks

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

F Male DBS Connector Dimensional and Performance Specification

Module 5. Broadcast Communication Networks. Version 2 CSE IIT, Kharagpur

What s News in Tax Analysis That Matters from Washington National Tax

Guidelines for Fiber Optic Cable Permits

Cable Preparation Best Practices for Fiber Optic Indoor/Outdoor Stranded Loose Tube Cable

AMERICAN NATIONAL STANDARD

SECTION 611 ACCEPTANCE PROCEDURES FOR TRAFFIC CONTROL SIGNALS AND DEVICES

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

SECTION TELECOMMUNICATIONS ACCEPTANCE TESTING

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Optical Cable Pre-Construction Survey. Keywords Stationary Reel Method, empty innerducts, sub-ducts, microducts, Intermediate-feed manholes

Delaware Valley SCTE Comparing RF-over-Glass to HFC. Bill Dawson VP Business Development ARRIS Access & Transport bill.dawson@arrisi.

AUSTAR Multi Dwelling Unit Installation Guidelines 2008

Model GS Port Node 1 GHz with 40/52 MHz split

SECTION 2 TECHNICAL DESCRIPTION OF BPL SYSTEMS

How To Design An Outside Plant (Osp) Network Design

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

FTTH ARCHITECTURE WHITE PAPER SERIES

Coaxial Cable Products Guide. Connectivity for Business-Critical Continuity

Broadband Telecommunications Drop Amplifier

STATE TAX COMMISSION OF MISSOURI ASSESSOR MANUAL

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs)

Connectivity in a Wireless World. Cables Connectors A Special Supplement to

How To Get A Power Line Extension

Recommendations for Marking Communication Facilities with Use of 3M EMS Electronic Markers

Pole Attachment Guidelines and Procedures Revision September 2015

ACCESS CHARGE A fee charged subscribers or other telephone companies by a local exchange carrier for the use of its local exchange networks.

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

DSA800 Series Spectrum Analyzer

AC and DC Drive System Installation Information

TEL: +44 (0) FAX: +44 (0)

ENGINEERING COMMITTEE Digital Video Subcommittee SCTE METHODS FOR CARRIAGE OF CEA-608 CLOSED CAPTIONS AND NON-REAL TIME SAMPLED VIDEO

4RU High Density Shelf Installation Instructions

Permit No. Permit Fee: $ Permit Expires (D+90 days): Business Name: Applicants Name: Telephone Number: Address:

SATELLITE MASTER ANTENNA TELEVISION SYSTEM

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

[ Fiber Optics ] [ Voice & Data Networks ] [ Underground Construction ] [ Engineering ] [ Emergency Fiber Optic Restoration ]

FIBER-OPTIC CABLE PLAN CHECK

10-3. SYSTEM TESTING AND DOCUMENTATION

AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding

Simple satellite TV in residential complexes

Cable Network Transparency Fiber Optic Monitoring

AN INTRODUCTION TO MAGNETIC AND UTILITY LOCATING BASICS

Enhancing High-Speed Telecommunications Networks with FEC

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

LAP NODO ÓPTICO 2/4 SALIDAS WT-8604JL

IP Camera Network Installations are More Difficult than Analog Camera Installations? Not So!

ADSL part 2, Cable Internet, Cellular

FIBRE TO THE BTS IMPROVING NETWORK FLEXIBILITY & ENERGY EFFICIENCY

What s at the Antenna Counts The Value of Distributed Amplifiers in DAS Solutions

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER

Embedded FM/TV Antenna System

Leveraging Embedded Fiber Optic Infrastructures for Scalable Broadband Services

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

ANSI/CEA Standard. Emergency Alert Metadata for the Home Network ANSI/CEA-2035 (J-STD-070)

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Fiber s Role in the Video Security & Surveillance Network. Curt Carlson Product Manager Transition Networks

Technical Guidance and Testing Procedure for Static and Dynamic Demand Response and Battery Storage Providers of Frequency Balancing Services

On Cables and Connections A discussion by Dr. J. Kramer

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Questions Regarding Proposed Utility Undergrounding in Kensington

SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR FLEXURE

THERMAL DESIGN AND TEST REQUIREMENTS FOR OUTSIDE PLANT CABLE TELECOMMUNICATIONS EQUIPMENT Al Marshall, P.E. Philips Broadband Networks

800 Communications Circuits


INFOCOMM DEVELOPMENT AUTHORITY OF SINGAPORE CODE OF PRACTICE FOR THE PROVISIONING OF COAXIAL CABLE HOME NETWORKING SOLUTIONS

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

DISTRIBUTION SYSTEMS INDEX NOV 06 SECTION 2. Detroit Ann Arbor Mt. Clemens Port Huron

AUDIO. 1. An audio signal is an representation of a sound. a. Acoustical b. Environmental c. Aesthetic d. Electrical

CONCEPTS of GARMENT AND FABRIC SYMMETRY Garments Symmetric Asymmetric Garment is Symmetric (the Vertical Centerline of the body) Face Face

Scope: Communications and Electronic Systems addressed in this section include:

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

Copyright. Transport networks. Physical layer Transport and access networks. Pag. 1

SERVICE - GENERAL Residential, Commercial, Industrial

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

Sectoral dictionary of competencies. page 1

E-Option Multi-taps Conditioning at the Tap

CCTV System Troubleshooting Guide

SECTION 5 DRAFTING STANDARDS

CX380X Advanced Spectrum and Burst QAM Analyzer

Transcription:

z ENGINEERING COMMITTEE Construction and Maintenance Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 87-1 2003 (formerly CMS WG6-0001) Graphic Symbols For Cable Telecommunications Part 1: HFC Symbols

NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards are intended to serve the public interest by providing specifications, test methods and procedures that promote uniformity of product, interchangeability and ultimately the long term reliability of broadband communications facilities. These documents shall not in any way preclude any member or non-member of SCTE from manufacturing or selling products not conforming to such documents, nor shall the existence of such standards preclude their voluntary use by those other than SCTE members, whether used domestically or internationally. SCTE assumes no obligations or liability whatsoever to any party who may adopt the Standards. Such adopting party assumes all risks associated with adoption of these Standards, and accepts full responsibility for any damage and/or claims arising from the adoption of such Standards. Attention is called to the possibility that implementation of this standard may require the use of subject matter covered by patent rights. By publication of this standard, no position is taken with respect to the existence or validity of any patent rights in connection therewith. SCTE shall not be responsible for identifying patents for which a license may be required or for conducting inquiries into the legal validity or scope of those patents that are brought to its attention. Patent holders who believe that they hold patents which are essential to the implementation of this standard have been requested to provide information about those patents and any related licensing terms and conditions. Any such declarations made before or after publication of this document are available on the SCTE web site at http://www.scte.org. All Rights Reserved Society of Cable Telecommunications Engineers, Inc. 140 Philips Road Exton, PA 19341 ii

TABLE OF CONTENTS Introduction...1 1. Poles Symbols...2 2. Cable Support Elements...3 3. Anchoring and Guying with Poles Shown...3 4. Miscellaneous Symbols...4 5. Underground Designations...4 6. House Drop Designations with Poles Shown...5 7. Make Ready or Pole Line Preparation Recommendations...5 8. Amplifiers...6 9. Splitting Devices...6 10. Powering Devices...7 11. Line Devices...7 12. Subscriber Taps...8 13. Line Terminators...8 14. Signal Processing Locations...9 15. Coaxial Cables...9 16. Optical Power Symbols...10 17. Splice Locations, Optical...11 18. Miscellaneous, Optical...11 19. Data Blocks...12 20. End of Line Information...12 iii

GRAPHIC SYMBOLS FOR CABLE TELECOMMUNICATIONS SYSTEMS Introduction Basic Considerations The symbols for devices do not indicate types or model numbers of any manufacturer. They represent the function of the device operated within a CATV system. The symbols permit easy addition of model or type numbers within or near their outline. If such model or type designations are used, an explanation of these designations should be placed on a legend sheet for the drawing on which the symbols appear. Proposed Drafting Practices The orientation of a symbol on a drawing, including a mirror image presentation, does not alter the meaning of the symbol. Line width does not affect the meaning of a symbol. In specific cases, a wider line may be used for emphasis. Generally, lines must be made sufficiently wide to avoid loss of resolution during photocopy reduction. Symbols shown in this text are in the approximate correct size and proportion. This relationship should be maintained as nearly as possible on any particular drawing regardless of the symbol scale. Symbols may be drawn to any proportional size that suits a particular drawing, depending upon reduction or enlargement anticipated. If essential for purposes of contrast, some symbols may be drawn relatively smaller than the other symbols on a drawing. The Standard recommends the use of no more than two sizes on a given drawing. For simplification or clarification of a drawing, parts of a symbol for devices, such as amplifiers, may be separated. If this is done, suitable designations to show proper correlation of the parts must be provided. The Symbols Due to the necessary crowding of symbols onto CATV mapping and grid diagrams, some symbols are structured differently than those used in electrical and electronic diagrams. 1

1. POLES POWER POLE TELEPHONE POLE JOINT USAGE (power and telephone pole) CATV POLE CONCRETE POLE STEEL POLE FIBER REINFORCED POLE POWER TRANSFORMER POLE JOINT USE WITH POWER TRANSFORMER POWER TRANSFORMER PLATFORM TRANSMISSION LINE CONTACT OTHER SUPORTING TYPE STRUCTURES Show approximate structure outline or a portion thereof in this manner. RISER POLE Use of a number indicates vertical distance from serial connection to ground level. DROP POLE Add "DP" by any pole In this section, riser and drop poles are shown as joint use because this occurs most frequently. Unless otherwise specified, the standard considers wooden poles. The Standard states that unless otherwise specified on drawings or referenced documents, pole usage and ownership are the same. For modification, a designation may be shown adjacent to the pole symbol. 2

EXTENSION ARM (used by CATV) TENSION STRAND SLACK SPAN STRAND 2. CABLE SUPPORT ELEMENTS MID-SPAN CROSSOVER In this section, poles are shown as joint because this occurs most frequently. PUSH BRACE To show a push brace, the support pole is a smaller symbol. It shall be drawn in its actual supporting location relative to the pole it is bracing. OVERHEAD GUY POLE-TO-POLE GUY DOWN GUY WITH ANCHOR " " symbol added to anchor symbol indicates "Set Anchor." Existing CATV Anchor - Set CATV Anchor - 3. ANCHORING AND GUYING SIDEWALK DOWN GUY WITH ANCHOR " " symbol added to anchor symbol indicates "Set Anchor." Existing CATV Anchor - Set CATV Anchor - TREE GUY ROCK GUY BUILDING GUY In this section, poles are shown as joint use because this occurs most frequently. 3

4. MISCELLANEOUS SYMBOLS BOND B GROUND LOCKBOX In this section, poles are shown as joint use because this occurs most frequently. 5. UNDERGROUND DESIGNATIONS UNDERGROUND ROUTING DIRECT BURIED CONDUIT ROUTING PEDESTAL MANHOLE VAULT " " = Optional user defined attribute HANDHOLE " " = Optional user defined attribute ROAD BORE (solid portion with slashes) Tick marks represent length dividers. EXISTING POWER TRANSFORMER 4

6. HOUSE DROP DESIGNATIONS HOUSE COUNT The numeral indicates the number of actual house drops at this location. The numeral on top indicates number of actual drops. The numeral on bottom indicates number of potential house drops. MULTIPLE DWELLING UNITS The numeral indicates the number of dwelling units. INSTITUTIONAL BUILDING (school, church, police, fire, etc.) Designated appropriately as to the type of building or service. COMMERCIAL COUNT The numeral indicates the number of actual commercial drops at this location. " " = Optional user defined attribute 7. MAKE READY OR POLE LINE PREPARATION MAKE READY Arrangement of existing equipment on the pole must be altered for CATV installation. " " = Optional user defined attribute In this section, poles are shown as joint use because this occurs most frequently. 5

8. AMPLIFIERS SINGLE OUTPUT AMPLIFIER Input Output MULTIPLE OUTPUT AMPLIFER Input Output LINE EXTENDER Input Output " " = Optional user defined attribute or graphics Examples shown are for guidance (not standard). 9. SPLITTING DEVICES 2-WAY SPLITTER 3-WAY SPLITTER Dot shows high output leg, if unbalanced. DIRECTIONAL COUPLER Model or value designations are to be shown adjacent or inside symbols. The high loss leg leaves from the angular half of the symbol. Indoor drop splits may have additional user defined symbols. 6

10. POWERING DEVICES AC POWER BLOCK AC POWER INSERTER " " = Optional user defined attributes SB POWER SUPPLY "SB" = Stand By " " = Optional information: voltage, current load, PS name, status monitor. NON-SB POWER SUPPLY "SB" = Stand By " " = Optional information: voltage, current load, PS name, status monitor. CENTRALIZED POWER SUPPLY " " = Optional information: voltage, current load, PS name, status monitor, port numbers. NOTE: Additional graphics such as a circle around the symbol may also be used to designate new/existing locations. 11. LINE DEVICES IN-LINE EQUALIZERS SPLICE " " = Optional user defined attribute or graphics 7

1-OUTPUT DIRECTIONAL TAP 12. SUBSCRIBER TAPS 2-OUTPUT DIRECTIONAL TAP 3-OUTPUT DIRECTIONAL TAP 4-OUTPUT DIRECTIONAL TAP 8-OUTPUT DIRECTIONAL TAP " " = Represents value of tap " " = Represents value of pad, cable equalizer, addressable or telephony tap Indoor taps may have additional user defined symbols. 13. LINE TERMINATORS RF TERMINATOR (4-output tap shown for example only) SELF-TERMINATING TAP Applies to lowest value tap within any family group. (4-output tap shown for example only) Self-terminating tap may be shown without symbol. 8

14. SIGNAL PROCESSING LOCATIONS HEADEND Location where the highest level of signal processing takes place. PRIMARY HUB In multi-level networks, a signal processing location connected between the headend and secondary hubs or nodes. SECONDARY HUB In multi-level networks, a signal processing location connected between the primary hub and the node. WIRELESS HUB " " = Optional user defined attributes TYPICAL CABLE SYMBOLOGY 1.000 INCH (25.4MM) 0.875 INCH (22.2MM) 15. COAXIAL CABLES 0.750 INCH (19.1MM) 0.625 INCH (15.9MM) 0.500 INCH (12.7MM) 0.412 INCH (10.5MM) OPTIONAL CABLE SYMBOLOGY For specialty cables and cables listed in ANSI/SCTE 15, 2001 (Examples) 0.750 INCH P3 0.540 INCH QR 750P3 540QR 9

16. OPTICAL DEVICES OPTICAL AMPLIFIER "" = Indicates the gain (db) DEMULTIPLEXER "" = Indicates number of outputs MULTIPLEXER "" = Indicates number of inputs OPTICAL TRANSMITTER " " = Input RF level " " = Output optical power OPTICAL NODE " " = Input optical power " " = Output RF level (examples) 1 2 3 4 A B C D 1 2 3 4 10

2-WAY SPLICE 17. OPTICAL SPLICE SYMBOLS 3-WAY SPLICE 4-WAY SPLICE >4-WAY SPLICE MID-ENTRY SPLICE / RING CUT 18. MISCELLANEOUS OPTICAL SYMBOLS OPTICAL FIBER CABLE " " = Indicates the fiber count " " = Denotes user defined attributes OPTICAL STORAGE LOOP "" = Denotes user defined attributes CONNECTOR " " = Connector type SPLITTER "" = Percent or db loss Symbol shown with optional outputs to be added as necessary FIBER SHEATH TRANSITION (Aerial to/from UG) " " = Indicates footage stamp number Symbol--> FIBER FOOTAGE/SEQUENTIAL MARKER " " = Indicates footage stamp number Symbol--> 11

SUGGESTED STYLES (scale to fit maps) Information normally appearing includes: - Amplifier Number - Power Supply Number and Power Feed - AC Voltage - Amplifier Cascade - Amplifier Output at Design Frequency - Amplifier Input at Low Forward Channel - Forward Equalizer - Forward Pad - Reverse Output Level - Reverse Input Level - Reverse Equalizer - Reverse Pad - Amplifier Part Number - Footage to Previous Amplifier - Passings Served by Active 19. DATA BLOCKS The size, shape, and rotation of the identification box is at the discretion of the designer. SUGGESTED STYLES (scale to fit maps) Information normally appearing includes: - High Digital Signal - High Analog Signal - Low Analog Signal - AC Voltage 20. END OF LINE BLOCKS The size, shape, and rotation of the identification box is at the discretion of the designer. 12