Distributed Redundancy in data center applications



Similar documents
Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

Electrical Efficiency Modeling for Data Centers

Building Technologies. Access Control. SiPass integrated Fully expandable system that grows with your business

Totally Integrated Power SIESTORAGE. The modular energy storage system for a reliable power supply.

How To Use Rittal'S Rizone

Electrical Efficiency Modeling of Data Centers

Power and Cooling Capacity Management for Data Centers

Begin using tomorrow s security features today.

Statement Of Work. Data Center Power and Cooling Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary

Server Technology, Inc.

DESIGO INSIGHT V2.35 Pharma solution SP1 System description

Opportunity of Energy Saving in electrical path is lesser as compared to other areas

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

Designed for uptime. Defining data center availability via a tier classification system

Aluminum versus Copper Conductors

Siemens Gas Turbines over 100 MW

THE GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCiE

MM8000 safety and security with smart danger management. A scalable and flexible management station for any requirement. Answers for infrastructure.

Energy efficiency in building automation and control

Cisco Nexus 7000 Series Power Supply Modules

Thinking Outside the Box Server Design for Data Center Optimization

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Voice alarm system E100 the new standard for safe evacuation

Eni Green Data Center - Specification

Room thermostats wide variety and high energy efficiency

Air damper actuators

Compact Monitoring Technology your environmental monitoring solution

Idle Data Analysis & Charts for the Draft 3 ENERGY STAR Computer Server Specification 10/31//08

Power Distribution Considerations for Data Center Racks

Kinetic energy recovery on railway systems with feedback to the grid

OPTIMIZING POWER SYSTEM PROTECTION FOR MODERN DATA CENTERS

As close to perfection. development and production. Modular data center

High-precision valve control using intelligent positioners. sipart

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Datacenter Clarity LC for colocation owners and tenants. The Data Center Infrastructure Management (DCIM) solution from Siemens. siemens.

SPPA-T3000 Control System The Benchmark in Controls

KNX for building and room automation simple and efficient

Prediction Is Better Than Cure CFD Simulation For Data Center Operation.

PSS E. High-Performance Transmission Planning Application for the Power Industry. Answers for energy.

Measuring Energy Efficiency in a Data Center

IT White Paper. N + 1 Become Too Many + 1?

Be ready for emergencies

Certified long-term data archiving with ultra-redundant hard disk storage. Silent Cubes

Phase Modular Finally the benefits of Modular ups are for all

LS/ATN Living Systems Adaptive Transportation Networks

R&S BC NETSTATE Open network management software for broadcast applications

Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

Green HPC - Dynamic Power Management in HPC

How can we prevent security breaches?

How To Powertrain A Car With A Hybrid Powertrain

Dynamic Power Variations in Data Centers and Network Rooms

Maximum Efficiency in Technical Plant Management. SPPA-M3000 Plant Answers for energy.

How To Power Supply In Data Centres

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Power Island. Industrial Power Plants. / energy

More efficiency in office buildings with HVAC, lighting and security

Safety technique. Emergency stop module BO 5988 safemaster

Managing the Real Cost of On-Demand Enterprise Cloud Services with Chargeback Models

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

D Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM

ABB PSPS Erich Steinmann; Generator control-2013

Patch management and security. updates SIMATIC. Process Control System PCS 7 Patch management and security updates. Preface 1

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM. Answers for infrastructure.

Understanding Delta Conversion Online "Output Power Factor Ratings" - Part 7

Can old buildings be just as energy-efficient as new ones?

30 ms High Speed Transfer System (HSTS) Product Description

More efficiency in schools with HVAC, lighting and security

Case Study Nottingham Trent University

Efficient building technology for retirement and nursing homes

Dynamic Power Variations in Data Centers and Network Rooms

AbSTRACT INTRODUCTION background

ASERIES ATM Access Management System

A favorable investment in solar power

More efficiency in hotels with HVAC, lighting and security

Overload Protection in a Dual-Corded Data Center Environment

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

AC vs DC Power Distribution for Data Centers

Building a Tier 4 Data Center on a Tier 1 Budget

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

UPS System Capacity Management Configuration Utility

Intensium Max. A range of ready-to-install containerised energy storage for renewable energies and grid management

Data center management suite. Providing optimal control and efficiency to data center management.

Transcription:

siemens.com/datacenters Distributed Redundancy in data center applications How power supply configurations increase reliability and optimize investment and operational cost White aper November 214 The Information Communication and Technology sector is moving at a rapid pace. It transforms our life vision and generates an increasing demand for centralized processing power and stored information. s a consequence, Data Center facilities grow in both number and size. Over two-thirds of global electricity production is based on the consumption of fossil fuels. Therefore, as major and increasing energy consumers, Data Centers are inextricably linked with global energy challenges and climate change. Generally, the optimal efficiency point (or 'sweet spot') of critical power distribution components occurs at the rated power capacity. However, as a result of redundancy requirements, critical power systems in Data Centers are operated below their rated capacity. Depending on the conceptual design and especially in dual cord server configurations, the critical power system can operate well below % during normal operation. Needless to say that this not an optimal situation from neither the efficiency nor the investment point of view. The conceptual design of the critical power path itself is a major contributor to the maximum operational load of the system during normal operation. The Distributed Redundancy concept is one of the designs that is implemented to increase normal load without sacrificing availability and reliability. It therefore has a positive effect on both investment and operational cost. This white paper elaborates on the design implications of the Distributed Redundant power distribution concept for dual cord server applications. Written by David Meulenbroeks Siemens Center of Competence Data Centers, The Netherlands. Siemens G 214. ll rights reserved 1

White paper Distributed Redundancy in data center applications November 214 Contents 3 Distributed Redundancy: the basics 3 Distributed Redundancy over two supply systems 4 Distributed Redundancy over three supply modules 5 Distributed Redundancy over four supply modules 6 General characteristics 7 Impact of Distributed Redundancy on data center facilities 8 cronyms and variables Siemens G 214. ll rights reserved 2

White paper Distributed Redundancy in data center applications November 214 Distributed Redundancy: the basics Distributed Redundancy over two supply systems Distributed Redundancy in its simplest form is probably the best known design concept for critical power supply systems in data centers. It is also referred to as the True - design. Figure 1 gives a simplified overview of this design. It shows normal operation as well as the power balance shift in case of a -side main supply fault. The figure presents the two main electrical operational modes for a data center: Normal operation and Emergency operation. 3 3 6 Normal Operation Emergency Operation Figure 1 Distributed Redundancy over two supply systems (True - design) In this example, the total ICT load [ICT] is presented as the mathematical sum of 6 individual loads of 1 ; the black figures in the picture. These loads are dual cord and it is assumed that the load is equally distributed over both cords, or - ; the green values in the picture. In the Distributed Redundancy nomenclature, the True - design as shown in figure 1 is defined as Distributed Redundancy over two supply systems. With these two supply systems, the 6 loads are combined in a single Group [LG], as there is only one combination of supply feeders: -. In this example the load of this load group equals 6. In normal operation, this configuration results in a cumulated load per ower Supply Module (or ) of 6 3. When in emergency operation - with - off line as shown in figure 1 - the load shifts to the -side supply. The cumulated load for - in that operational mode is therefore equal to the total ICT load [ICT], or 6 6. In this example, the design is characterized by the following Distributed Redundancy parameters: Total ICT load [ICT] 6 Normal load per [norm(2)] 3 Emergency load per [max(2)] 6 Installed base [inst(2)] 1.2 The index "2" in the variables [E.g. max(2)] indicates to Distributed Redundancy over two supply systems. 1 Neither the unit (W, kw or kv) nor the absolute value of the figures mentioned has significance in this example as the relation between the figures of the different configurations are relevant, not their absolute value. Siemens G 214. ll rights reserved 3

White paper Distributed Redundancy in data center applications November 214 When considering the ICT-load exclusively (thus excluding power requirements for cooling or other auxiliary systems), the nominal power rating of the is to be equal or larger than the Emergency load on each : max(2). In the example above, max(2) equals ICT and is 6. From these results, the following general relations can be derived. These are exemplary for Distributed Redundancy over two supply systems. The normal load relative to the emergency load per is: Normal load per norm ( 2 ) 3 % Emergency per ( ) 6 max 2 The installed base 2 inst relative to ICT equals: Total installed base inst( 2 ) 12 TotalICT load 6 ICT 2% Distributed Redundancy over three supply modules When an additional ower Supply Module is introduced in the design of figure 1, and the load is equally distributed over all three of the 's, the configuration of figure 2 is obtained. Following the nomenclature introduced above, this design is referred to as Distributed Redundancy over three supply systems. gain, for this example, the ICT load [ICT] equals 6. The loads are distributed over all combinations of 's. This results in a total of 3 Groups [LG] -, -C and -C each with a normal load of 2. 2 2 2 C 3 3 C Normal Operation Emergency Operation Figure 2 Distributed Redundancy over three supply systems nalogous as described for Distributed Redundancy over two supply systems previously, in this example Distributed Redundancy over three supply systems is characterized by the following parameters: Total ICT load [ICT] 6 Normal load per [norm(3)] 2 Emergency load per [max(3)] 3 Installed base [inst(3)] 9 2 The installed base inst(n) refers to the nominal output of the. This excludes any redundancy inside the as for example N+1 configured modular US systems. Siemens G 214. ll rights reserved 4

White paper Distributed Redundancy in data center applications November 214 The general relations for Distributed Redundancy over three supply systems are therefore: The normal load relative to the emergency load per : Normal load per Emergency per norm max ( 3 ) ( ) 3 2 66% 3 Installed base relative to ICT: Total installed base inst( 3 ) 9 TotalICT load 6 ICT 1% Distributed Redundancy over four supply modules When the three design of figure 2 is expanded with an additional module, the four configuration of figure 3 is obtained: Distributed Redundancy over four supply systems. The example is based on a total ICT load ICT of 6. nd again, the loads are distributed over all combinations of 's: -, -C, -D, -C, -D and C-D. This results in a total of 6 Groups with a load of each. 1 1 1 1 C D 2 2 2 C D Normal Operation Emergency Operation Figure 3 Distributed Redundancy over four supply systems In this example Distributed Redundancy over four supply systems is characterized by the following parameters: Total ICT load [ICT] 6 Normal load per [norm(4)] 1 Emergency load per [max(4)] 2 Total installed base [inst(4)] 8 Siemens G 214. ll rights reserved 5

White paper Distributed Redundancy in data center applications November 214 The generic relations for Distributed Redundancy over four supply systems become: Normal load relative to the emergency load per : Normal load per Emergency per norm max ( 4 ) ( ) 4 1 75% 2 Installed base relative to ICT: Total installed base inst( 4 ) 8 133% TotalICT load 6 ICT General characteristics Theoretically, the Distributed Redundancy principle can be expanded infinitely by adding ower Supply Modules. s a result, both norm( )/max( ) and inst( )/ICT will approach %. In the limit situation - an infinite number of 's - the normal load of the will equal the emergency load. lso, the installed base will equal the total ICT load. From an installed base and efficiency point of view, this limit situation might look like ideal. However tempting, this limit obviously represents a hypothetical configuration. With the increasing number of ower Supply Modules, the number of Groups will also become infinite as it equals the sum 1+2+3+.. +(#-1). ut besides being infinite in number, these Groups will have a maximum load value max(lg ) that approaches. Furthermore, the distribution system is going to be infinite as well. Not a very useful configuration. Table 1 summarizes the main characteristics of the Distributed Redundancy principle with an increasing number of ower Supply Modules. Number of supplies Table 1 Main characteristics of Distributed Redundancy with increasing number of 's Number of Groups Ratio of normal and emergency load on supply Ratio of installed base and load Ratio of load group load and emergency load on supply # [n] # LG norm(n)/max(n) inst(n)/ict max(lgn)/ max(n) 2 1 % 2 % % 3 3 67 % 1 % 67 % 4 6 75 % 133 % % 5 1 8 % 125 % 4 % 6 15 83 % 12 % 33 % 7 21 86 % 117 % 28 % 8 28 88 % 114 % 25 % From this table we can conclude that - depending on the application - the optimum configuration for Distributed Redundancy is somewhere between 4 and 6 ower Supply Modules: elow 4 Modules there is relatively much to be gained by adding a as the ratio norm()/max() significantly increases and the number of Groups remains manageable. bove 6 Modules the ratio norm()/max() flattens and the number of Groups becomes impractical to handle. Siemens G 214. ll rights reserved 6

White paper Distributed Redundancy in data center applications November 214 Impact of Distributed Redundancy on data center facilities When selecting optimal power architecture for a facility, data center managers have to consider different factors and understand the impact of each one on their facility. When designing the electrical power distribution configuration, the data center designers need to consider both initial and future load demands. s a result, many data centers are operating at significantly less than percent of design load much of the time. Considering the right power distribution load balancing design before a facility is constructed, is a good way to move to cost efficient data center without compromising on reliability. When correctly implemented and maintained, the Distributed Redundancy principles meet with the reliability criteria. It can be applied to the power distribution level of redundancy requested for the data center (N, N+1, 2N, 2(N+1); etc.). Distributed Redundancy can definitely provide both flexibility on power capacity and cost control optimization without losing data center reliability. Siemens G 214. ll rights reserved 7

White paper Distributed Redundancy in data center applications November 214 cronyms and variables ICT LG ICT inst max norm US Information and Communication Technology Group ower Supply Module Sum of critical load Installed power: sum of total installed ower Supply Modules in emergency operation mode in normal operation mode Uninterruptible ower Supply Siemens G uilding Technologies Division International Headquarters Gubelstrasse 22 631 Zug Switzerland Tel +41 41 724 24 24 E-mail datacenters.ic@siemens.com Siemens G Energy Management Division Freyeslebenstrasse 1 9158 Erlangen Germany www.siemens.com/datacenters ll rights reserved. ll trademarks used are owned by Siemens or their respective owners. Siemens G 214 Siemens G 214. ll rights reserved 8