BERMAD Fire Protection



Similar documents
Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

BERMAD Fire Protection

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

TECHNICAL DATA. Dry 122a. November 12, 2013

Oil and Coolant Circulating Heating System. Model - OCSM

Wet alarm valves. Wet alarm valves. FM trim

I-768 FireLock NXT Dry Valve

Fire Pump Plan Review March 2010

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

Diameter 3" 4" 6" 8" Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

PBX Series Quick Fit Connector Bimetallic Steam Traps

EXHIBIT A SCOPE OF WORK

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Potter Electric Sprinkler Monitoring Training Manual

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

VOYAGER 570G. 744A Sprayer Control

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

Inspection and Testing of Water-Based Systems

Your safety and the safety of others are very important.

Important Ontario Fire Code Information for Building Owners in the City of Windsor

EXETER TOWNSHIP DRY OR WET CHEMICAL FIRE SUPPRESSION SYSTEMS

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Installation, Maintenance, & Repair Series 4000B/LF4000B

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Float and Thermostatic Traps Series H, C and X

Sprinkler Guards Model C Model D

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

VANGUARD A OPERATOR S MANUAL PORTER. FM-952 Rev. E 7/07

Utility Distribution Systems

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

SELECTION, APPLICATION AND MAINTENANCE

MODEL INSTALLATION INSTRUCTIONS

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

PRESSURE REDUCING CONTROL VALVE

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

INSPECTION AND TESTING OF EMERGENCY GENERATORS

Standard Hydraulic Piping Flushing Procedure

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Pr o d u c t In f o r m at i o n V008.0

CHAPTER. Standpipes and Hose Systems OVERVIEW. Standpipe and Hose Systems Defined

IOM SERIES 820-E/P Electro-Pneumatic Positioner

Diesel Engine Driven Generators Page 1 of 6

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Wet System. Technical Manual for Operation, Maintenance, and Troubleshooting

CARING FOR YOUR WATER HEATER

SunMaxx Solar Filling Station Operating Instructions

HERNANDO COUNTY FIRE ALARM GUIDELINES

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

FAIRBANKS NIJHUIS FIRE PUMPS.

TECHNICAL ADVISORY BULLETIN

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

AIR LINE VALVES AND GAUGES

ClearView 100. Instruction Manual

ENGINEERING SPECIFICATIONS

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Compressor Service & Maintenance Manual

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Technical Data. Installation

University of Houston Master Construction Specifications Insert Project Name

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Element D Services Plumbing

G670 Intermittent Pilot Ignition Controls

Installation Manual DIAPHRAGM WELL TANK

Fire suppression system for engine compartments USER MANUAL

Transformer Deluge Systems

FIVE YEAR CERTIFICATION REPORT

SUMP PUMP. Sump Pump Backup Systems. City of Ann Arbor B A C K U P O P T I O N S. Does everyone need a backup system?

Design & Construction Standards, Revised January

NATIONAL FIRE ALARM AND SIGNALING CODE

Automatic Fire Sprinkler Submittal Requirements

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)

INSTALLATION, OPERATION & MAINTENANCE MANUAL

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

TYPE E Main Valve Sizes 3 /8 through 12

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

LK Electric Boiler - 4,5

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Transcription:

400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD

400E-2M/700E-2M Bermad 2M IOM - IOM Safety First BERMAD believes that the safety of personnel working with and around our equipment is the most important consideration, read all safety information below before attempting to perform any maintenance function. Only authorized personnel should perform all maintenance tasks. Comply with all approved and established precautions for working with the equipment and/or environment. When performing a procedure, follow the steps in succession without omission. Description The Bermad Electrically Controlled Deluge Valve is suitable for automatic water spray or foam deluge systems that include electric detection and piping systems with open nozzles. This Bermad Deluge Valve is equipped with an EasyLock Manual Reset (M) (EMR) device, which locks it into an open position during fire detection and system activation. The Deluge Valve is operated by an electric Solenoid Valve and requires a listed System Control Panel with a compatible electrical fire detection system. In Fire condition, activation of the detection system causes the System Control Panel to be activate, this in turn opens the Solenoid Valve (14B), causing the Bermad Deluge Valve (1) to open, and thereby allowing water to enter the system piping. Whenever either the Solenoid or the Manual Emergency Release (15B) is activated, the EMR locks the Deluge Valve in its open position. The Bermad Deluge Valve will close again only when the reset button on the EMR is pressed. Approvals/Listings The Bermad Deluge Valve is UL Listed only when installed with specific components & accessories. Refer to current UL Directory. Consult the manufacturer for any component approval recently to appear in the UL fire protection equipment directory. Installations NOTES: Wet Pilot height (if mounted) should not exceed that appearing on Table 1, "Maximum Elevation Above Valve". Any deviation in trim size or arrangement may adversely affect the proper operation of the Deluge Valve. All initiating devices (detectors), indicating appliances, releasing devices, wet pilot line actuation devices (such as thermostatic releases, and/or fixed temperature releases), as well as the system control panel, must be compatible and UL listed for use with the particular Deluge System. Refer to current "UL Listed Fire Protection Equipment Directory". Refer also to NFPA 13 or the applicable installation standards, codes and authorities having jurisdiction. WARNING: The Deluge Valve and trim must be installed only in areas where they will not be subjected to freezing temperatures. Installation Instructions 1. Allow enough room around the valve assembly for any adjustments and future maintenance/disassembly work. 2. Before the valve is installed, flush the pipeline to remove any dirt, scale, debris, etc. Not flushing the line may result in the valve being inoperable. 3. Install the valve in the pipeline with the valve flow arrow on the body casting in the proper direction. Ensure that the valve is positioned so that the cover/actuator can be easily removed for future maintenance. 4. Ensure that the EMR is Mounted Vertically (with the reset button up), and all other components are positioned correctly as per the appropriate drawing. Page 2 of 6 Rev 14/5/04 By: D. Eshel

400E-2M/700E-2M Bermad 2M IOM - IOM 5. The water supply priming line must be connected to the upstream of the system control valve. 6. Subjected to all other instructions, drawings and technical specifications, which describe Bermad Deluge Valve, install in their proper positions the components comprising the Deluge Trim Package, according to the drawing relevant to the specific type, hereby enclosed. 7. Install also the additional accessories, which appear in the drawing and which must be installed as shown in the drawing, although they are not packed together with the Bermad Deluge Valve itself. Table 2: Deluge Valve Equivalent Length Value (Steel Pipe), for use in hydraulically calculated systems 400E Valve Size Equivalent Length Value Meter (Ft) 700E Valve Size Equivalent Length Value Meter (Ft) 2 9.1 (30) of 2 pipe 2 11 (36) of 2 pipe 2½ 12.1 (40) of 2½ pipe 2½ 26.2 (86) of 2½ pipe 3 13.7 (45) of 3 pipe 3 17.4 (57) of 3 pipe 4 14 (46) of 4 pipe 4 28.7 (94) of 4 pipe 6 27.4 (90) of 6 pipe 6 32.6 (107) of 6 pipe 8 45.7 (150) of 8 pipe 8 49.1 (161) of 8 pipe 10 64.3 (211) of 10 pipe Electrical & Solenoid Requirements The Solenoid Valve shall be wired to the Releasing Control Panel according to information provided by the control panel manufacturer. Standard Solenoid data (others are optional): Voltage: 24VDC Normally Position: NC Enclosure Type: 1,2,3,3S, 4 and 4X/IP-65 (For Hazardous Locations enclosure, see catalog) Electrical Rating: 10.6 Watt / F (0.44 Amp) or less Ancillary/Optional Equipment If required, provide an Alarm Pressure Switch (P), to either activate an electric alarm, or shut down desired equipment. Connect it according to manufacturer instructions. If required, provide a Water Motor Alarm, it shall be assembled and installed according to instructions within it s package. It is recommended practice to provide an "Inspector's Test Connection" on the hydraulic release system. The inspector's Test Connection should be equipped with a ball valve (normally locked closed) capable of being opened to simulate the opening of a release. Operation Principle of Operation In the SET position, the line-pressure supplied to the main valve s control chamber via the priming line and through the EMR, is trapped by the EMR's internal check valve, by a closed 2-Way Solenoid Valve (14B), and by a closed Manual Emergency Release (15B). The trapped pressure holds the main valve s diaphragm and plug against the valve seat, sealing it drip-tight and keeping the system piping dry. In FIRE or test conditions, an electric detection system, through a control panel, triggers the Solenoid Valve to a open position, pressure is released from the control chamber by the opened Solenoid Valve or Manual Emergency Release. The EMR prevents line-pressure from entering the control chamber, Page 3 of 6 Rev 14/5/04 By: D. Eshel

400E-2M/700E-2M IOM latching the main valve open and allowing water to flow into the system piping and to the alarm devices. WARNING: Whenever the handle of the Emergency Manual Release (15B) is pulled, the Deluge Valve opens, and water flows into the system's piping and to the alarm devices, the Deluge Valve will close again only when the handle of the Emergency Manual Release is returned to its original position and the reset button on the EMR is manually pressed. Placing in Service/Resetting the System 1. Place the detector circuit in service. 2. Reset the Solenoid Valve (14B) by resetting the releasing control panel. 3. Close all emergency release valves. 4. Test supervisory circuits in releasing control panel. 5. Open the priming-line valve (18B). Check that there is no water flow from the Solenoid Valve. 6. Push and hold the EMR s reset button, this allows upstream water pressure to fill the Deluge Valve s control chamber. 7. When the control chamber pressure gauge () indicates full upstream pressure and is no longer rising, the release system is reset. 8. Slowly Open the supply Isolating Valve and check that no water flows into the system. 9. Depress the Drip Check (19B) and drain any water from the system side of the Deluge Valve. The system is now operational and in a standby mode. Ensure that the following Set Conditions are met. Set Conditions (Normal Conditions) Item All Main Isolating Valves All Manual Releases Alarm Shut-Off Valve (11A) Priming Ball Valve (18B) Control-Chamber Gauge Upstream Pressure Gauge Drip-Check Device (19B) Control Panel & Detections Releasing Devices Status OPEN and sealed with tamperproof seals CLOSE position and sealed OPEN position OPEN OPEN gauge valve, the Pressure Gauge indicates rate of pressure in Control-Chamber OPEN gauge valve, the Pressure Gauge indicates the upstream supply pressure to the Deluge Valve VENTED: Push the knob to confirm that there is no leakage. Are in service and in a stand-by position. CLOSED with no leaking Maintenance Removing The System From Service WARNING: When taking deluge system out of service, a fire patrol should be established in the system area. If automatic fire-alarm signaling equipment is utilized, the proper authority should be notified that the system is being removed from service. The insuring body and owner representative should also be notified when the system is being taken out of service. Removing Instructions 1. Shut off the main supply-isolating valve. 2. Close the Priming line valve (18B) to Deluge Valve Control chamber. Page 4 of 6 Rev 14/5/04 By: D. Eshel

400E-2M/700E-2M IOM 3. Open all drain valves. 4. Release the water pressure from the control chamber of the Deluge Valve by pulling the Manual emergency release (15B). 5. If auxiliary power is used, disconnect the power supply and batteries. 6. Place "Fire Protection System Out of Service" signs in the area protected by the system. Inspection and Testing 1. WARNING: Do not turn off the water supply to make repairs without placing a roving fire patrol in the area covered by the system. The patrol should continue until the system is back in service. 2. Prior to turning off any valves or activating any alarms, notify local security guards and the central alarm station, if used, so that a false alarm will not be signaled. 3. In any of the following inspections or testing procedures, if an abnormal condition exists, see Abnormal Conditions for possible cause and corrective action. 4. See NFPA Pamphlet No. 25 and also relevant publications by authorities having jurisdiction. Weekly Inspection 1. The system should be checked for Set Condition. See above Set Condition (Normal condition). 2. Observe the upstream pressure gauge () : it should indicate that the normal supply of water pressure to the Deluge Valve is maintained. Monthly Inspection and Test 1. Complete Weekly Inspection. 2. Test the water-motor alarm and/or electric alarm, by turning the alarm test valve (1A) to the open position. The alarm should sound. Turn to close position. 3. Depress the Drip Check (19B) to release accumulated water and to check main valve leakage (Significant water accumulation on the system side may indicate a sealing problem). Semi-Annual Inspection 1. Complete Weekly and Monthly Inspection and Test. 2. Inspect the electric detection system and electric release control panel, as suggested by the release control panel manufacturer. Annual Inspection and Test 1. Complete Weekly, Monthly and Semi-Annual inspections. 2. Place the system out of service (See Removing The System From Service above). 3. Trip the release-line system. 4. The interior of the Deluge Valve should be cleaned and inspected. 5. Place the system back in service. (See instructions "Placing the System in Service"). 6. The Deluge Valve must be activated at full flow. Note: The system will be flooded! Take all necessary precautions to drain water and prevent damage in the area protected by the system. 7. Trip-test the deluge system with an electric release control panel. The release may be tripped by the method suggested by the release control panel manufacturer. 8. The manual emergency release handle (15B) is to be pulled. The Deluge Valve should open and discharge water. Observe upstream Pressure Gauge () while full flow is on. Inspect all system nozzles. 9. Take all additional measures as required by NFPA-25 "Standard for the Inspection Testing and Maintenance of Water-Based Fire Protection Systems." 10. Clean the priming strainer (4B) prior to resetting the Deluge Valve. Abnormal Condition Troubleshooting 1. Alarm Fails To Sound A. Check for obstructions in the alarm test line. Page 5 of 6 Rev 14/5/04 By: D. Eshel

400E-2M/700E-2M IOM B. Clean the alarm-line strainer (if a water motor alarm is installed). C. Make certain the alarm is free to operate. D. Test the electrical circuit to the electric alarm (if utilized). 2. False Trip A. Check and test the electrical circuit to the Solenoid Valve (14B) B. Check for Malfunctioning EMR device. 3. Leakage Through Deluge Valve A. Check for clogged priming strainer (4B). B. Leaking control trim system. C. Damaged deluge valve internal elastomer or seat 4. Deluge Valve Will Not Reset A. The EMR Device is clogged or not reset properly B. Check for clogged priming strainer (4B), the screen should be properly cleaned. C. Closed priming valve (18B). C. Check for Foreign object lodged between seal and valve seat. D. Control Panel is not reset. Check for Faulty circuits, using manufacturer instructions. 5. Difficulty in Performance Where difficulty in performance is experienced, BERMAD or its authorized representative should be contacted if any field adjustment is to be made. Page 6 of 6 Rev 14/5/04 By: D. Eshel

400E-7M/700E-7M IOM Appendix: Maximum Elevation Above Valve for Bermad Deluge Valve with EasyLock Manual Reset 250 (75) Bermad 400E - *M height ft (m) 200 (60) 150 (45) 100 (30) 2 6 2½" 8 3 4 50 (15) 0 (0) 1.3 (20) 2.7 (40) 4.1 (60) 5.5 (80) 6.8 (100) 8.2 (120) 9.6 (140) 11 (160) Inlet Pressure psi (bar) 12 (175) 13.8 (200) 15.5 (225) 17.2 (250) 250 (75) Bermad 700E - *M 200 (60) height ft (m) 150 (45) 100 (30) 50 (15) 8 3 10 2½" 2 6 4 0 (0) 20 (1.3) 40 (2.7) 60 (4.1) 80 (5.5) 100 (6.8) 120 (8.2) Inlet Pressure psi (bar) 140 (9.6) 160 (11) 175 (12) 300 (21) Note: *Applied to models 1M, 2M and 2MC only.

Model 400E 2M Electrically Controlled Deluge Valve with EasyLock Manual Reset Sequence of Operation Closed Position 14B E M P 14A 19B 1A 11A W Legend: (1) Bermad 400E Main Deluge Valve (1A) Alarm Test Valve () Pressure Gauge (4B) Priming Stainer (5A) Drain Valve (11A) Alarm Shutoff Valve (14A) Check Valve (14B) Solenoid Valve (15B) Manual Emergency Release Assy. (18B) Priming Ball Valve (19B) Drip Check (M) Manual Reset Device Assy. 15B 1 5A Other System Items: (C) Releasing Control Panel (P) Pressure Switch (Option) (W) Water Motor Alarm (Option) C D 4B 18B Open / Operation E P W 14B M 19B 14A 1A 11A Water under pressure 15B 1 5A Vented to atmosphere C D 4B 18B 04.05.04 Figure 1

Model 700E 2M Electrically Controlled Deluge Valve with EasyLock Manual Reset Sequence of Operation Closed Position 14B E M 19B 14A 1A P 11A W Legend: (1) Bermad 700E Main Deluge Valve (1A) Alarm Test Valve () Pressure Gauge (4B) Priming Stainer (5A) Drain Valve (11A) Alarm Shutoff Valve (14A) Check Valve (14B) Solenoid Valve (15B) Manual Emergency Release Assy. (18B) Priming Ball Valve (19B) Drip Check (M) Manual Reset Device Assy. 15B 1 5A Other System Items: (C) Releasing Control Panel (P) Pressure Switch (Option) (W) Water Motor Alarm (Option) C D 4B 18B Open / Operation E 14B M P 14A 19B 1A 11A W Water under pressure 15B 1 5A Vented to atmosphere C D 4B 18B 04.05.04 Figure 1

Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: FP-400E-2M / 700E-2M Trim Component List Item Description Qty Note 1 MAIN DELUGE VALVE 1 2 UNION 1/2" 2 3 STREET ELBOW 1/2" 2 4 MALE ELBOW 1/2"X1/2" 3 5 NIPPLE 1/2" 6 6 CROSS 1/2" 2 7 PLUG 1/2" 1 8 REDUCING NIPPLE 1/2"X1/4" 2 9 TUBE 1/2" 1 11 STREET ELBOW 1/4" 1 12 DRAIN NIPPLE 1 4 13 DRAIN ELBOW 1 4 1A ALARM TEST VALVE - 1/2" BALL VALVE 1 2A GAUGE VALVE 1/4" 2 PRESSURE GAUGE 4" 2 2 4B PRIMING STRAINER 1/2" 1 5A DRAIN VALVE 1 1,4 11A ALARM SHUTOFF VALVE - 1/2" BALL VALVE 1 14A CHECK VALVE 1/2" 1 14B SOLENOID VALVE 1/2" ASCO 8210G207 1 5 15B MANUAL EMERGENCY RELEASE MODEL-D 1 1 18B PRIMING VALVE - 1/2" BALL VALVE 1 19B DRIP CHECK 1 5 M MANUAL RESET DEVICE ASSY. 1 5 Optional System Items: P PRESSURE SWITCH 1 5 W WATER MOTOR ALARM 1 5 Notes: (1) Shall be UL Listed in accordance with UL 258 (2) Shall be UL Listed in accordance with UL 393 (3) Shall be UL Listed in accordance with UL 753 (4) For 2 : ¾ Drain Valve For 2½ &3 : 1½ Drain Valve For 4 and larger : 2 Drain Valve (5) Shall be UL Listed for fire protection service (6) Construction material Brass/S.S 316 or corrosion resistant equivalent