ICP Test Report Certification Packet



Similar documents
TEST REPORT Page 1 of 9

Beysan San. Sitesi Fuar Cad. No: 27/A Beylikdüzü/İstanbul FAX NO : Attention : Şükrü Ulus Aktaş (kalite@tufankablo.

: EUROPE, ASIA, AFRICA, AMERICA

Organize Sanayi Bölgesi 21.Cadde No:1 ESKİŞEHİR FAX NO: Attention : Mustafa Günay (mgunay@doganglass.com)

Çetinkaya Pano Sac Tablo ve Plastik San. Tic. A.Ş.

Test Report No. F690101/LF-CTSAYAA

No. HKGEC Date: 26 Apr 2016 Page 1 of 6

RoHS Test Methods. Presented by: Bruce Peterson

Test Report No: (15) Date: 05-Apr-12 Page 1 of 5

Wurth Electronics Midcom Policy Statement on RoHS Compliance And Lead-Free Products

Test Report. RLSHE Page 1 of 6. Report No.

Package Material Declaration

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SANEM MATBAACILIK VE ULUSLARARASI TAŞ A.Ş.

RoHS CERTIFICATE OF COMPLIANCE FOR ACCUTOUCH SCREENS (Excluding AT4 Touch Screens)

Physical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

TEST REPORT Job No./Report No TR Date:5 January 2015 Page 1 of 11

3M Pin Strip Header Single and Dual Row.100,.235 /.318 Mating Length, Straight & Right Angle, Solder Tails 929 Series

RoHS COMPLIANCE STATEMENT

3M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series

The following merchandise was (were) submitted and identified by the client as : LAN CABLE LSZH 2006/01/ /01/05 TO 2006/01/19

TOXIC CHEMICALS IN COMPUTERS EXPOSED

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

TEST REPORT 26 October, 2005 Page 1 of 8

TEST REPORT Page 1 of 6

Elimination Of RoHS Substances In Electronic Products

TEST REPORT Page 1 of 5. Baksan Sanayi Sitesi 73.Blok No:8 ESKİŞEHİR TEL NO: Attention: Cengiz Serger (isikmaden@isikmaden.com.

TEST REPORT Page 1 of 7

China RoHS Directive Legislation Compliance October 2011

3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series

Chapter Outline. 3 Elements and Compounds. Elements and Atoms. Elements. Elements. Elements 9/4/2013

* TEST REPOR. TETAŞ Đç Ve Dış Ticaret A.Ş. Page 1 of 19 APPLICANT NAME

TEST REPORT Page 1 of 9 TEXTILE LABORATORY MANAGER

PCB RoHS Update OCT08 ELECTRONICS MANUFACTURING SERVICES

One sample of Lineplus Powerline 2300 Highlighter (Orange-Blue-Yellow-Green-Pink) BUYER :

* TEST REPOR. TETAŞ Đç Ve Dış Ticaret A.Ş. Page 1 of 26 APPLICANT NAME

TEST REPORT Page 1 of 6

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

R E S U L T S Page 2 of 5. REPORT : TURR July, 2014 Test Method Result Requirements. Metal body Metal handle Metal screw Metal gasket

1332 CHAPTER 18 Sample Questions

TEST REPORT Page 1 of 6

47374_04_p25-32.qxd 2/9/07 7:50 AM Page Atoms and Elements

Umur Kırtasiye San. ve Tic. AŞ. Neslihan Sözer Chemical Laboratory Manager

TRU RoHS Products Test Report

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

TEST REPORT Job No./Report No TR Date:12 June 2014 Page 1 of 5

HS 1003 Part 2 HS 1003 Heavy Metals Test

Keskin Color Kartpostalcılık A.Ş. Neslihan Sözer Chemical Laboratory Manager

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

REACH and RoHS System Supplier Training

DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech

UNIT (2) ATOMS AND ELEMENTS

TEST REPORT Page 1 of 6. Birikim Elektronik San. Tic. Ltd. Şti. Battery Directive (2006/66/EC) was performed on the item.

ALS TRIBOLOGY Engine Coolant Reference Guide

EXPERIMENT 7 Reaction Stoichiometry and Percent Yield

APPENDIX B: EXERCISES

Connection Cable for LED Driver Board

CHEMICAL REACTIONS OF COPPER AND PERCENT YIELD KEY

Chapter 8 - Chemical Equations and Reactions

Introduction to Elemental Analysis by ED-XRF Justin Masone Product Specialist 3 June 2015

GP2Y0D810Z0F. Distance Measuring Sensor Unit Digital output (100 mm) type GP2Y0D810Z0F

Hong Kong Green Label Scheme Product Environmental Criteria for Copying Machines, Printers, Fax Machines and Multifunctional Devices (GL )

TEST REPORT Page 1 of 7

Safety Data Sheet Aluminium profiles Apply for alloys Sapa EN AW 6060, 6063, 6005, 6005A, 6082, yellow chromated, with or without powder coating.

Standard methods in water analysis

Test Report No. CTSSA/ /12 Date : 18/06/2012 Page: 1 of 5 CTS Ref. CTSPN/12/0437/Osram

Distance Measuring Sensor Unit Measuring distance : 4 to 30 cm Analog output type

Test Report No.: GZ /CHEM Date: MAY 13, 2011 Page 1 of 6 (SVHC)

Fusca 2.4GHz SMD Antenna

EXPERIMENT 4 The Periodic Table - Atoms and Elements

Metals and Non-metals. Comparison of physical properties of metals and non metals

TEST REPORT Job No./Report No TR R1 Date:9 July 2014 Page 1 of 12

B) atomic number C) both the solid and the liquid phase D) Au C) Sn, Si, C A) metal C) O, S, Se C) In D) tin D) methane D) bismuth B) Group 2 metal

EXAMPLE EXERCISE 4.1 Change of Physical State

The Empirical Formula of a Compound

Heavy Metal Analysis for the Toy Industry by Inductively Coupled Plasma Optical Emission Spectroscopy

RoHS RIA November 2003

Material Safety Data Sheet For NiMH Batteries

Certificate of Analysis

Preparation of frequently used solutions

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

SODIUM CARBOXYMETHYL CELLULOSE

PRODUCT PROFILE. ELECTROLOY in partnership with FCT Asia Pte Limited. in manufacturing. Nihon Superior Lead Free Solder Bar.

ATOMS. Multiple Choice Questions

Potassium Aluminium Silicate (Mica) Chemical and Technical Assessment (CTA) Prepared by Daniel E. Folmer, Ph.D., and reviewed by Madduri V. Rao, Ph.D.

GP2Y0A02YK0F. Distance Measuring Sensor Unit Measuring distance: 20 to 150 cm Analog output type GP2Y0A02YK0F

Redox and Electrochemistry

HOMEWORK 4A. Definitions. Oxidation-Reduction Reactions. Questions

Green Product Management

EXPERIMENT 8: Activity Series (Single Displacement Reactions)

CRITERIA DOCUMENTATION VERIFICATION PRINTED PAPER (Commission Decision 2012/481/EU)

Umur Kırtasiye San. ve Tic. AŞ. Neslihan Sözer Chemical Laboratory Manager

CHAPTER Naming Ions. Chemical Names and Formulas. Naming Transition Metals. Ions of Transition Metals. Ions of Transition Metals

Chem 115 POGIL Worksheet - Week 4 Moles & Stoichiometry

Transcription:

ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 3.6 x 10 mm Fuse Product #: 875xxx Series Issue Date: February 19, 2013 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC, 2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued : <Global EHS Engineer> (1) Parts, sub-materials and unit parts This document covers the 3.6 x 10 mm Fuse, RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Remarks: Please see appropriate pages as identifed in Table 1 1

Table 1: List of Raw Materials covered by this report Total Parts Raw Material Part Number Raw Material Description Page(s) 1 Y50/ YJM (909-444) Ceramic Base - Body 3-13 2 934-065 Cap & Lead Assembly 14-17 3 082xxx Element- 5% by weight Ag Clad Cu 18-22 4 11-0803 (497xxx) Element Ni42Fe58MCuAg5% 23-27 5 10-1185 (497xxx-001) Element Ni42Fe58MCuMSn 28-33 6 7132 (425672) Ink-Black 34-42 7 692481 Solder Wire 43-48 8 063012 Element - Sn Plated Cu Clad Cu55 Ni45 49-56 2 Form 585-047 Rev. A 2/21/06

AOV"BPFS,U NO.: 4002R12100802+1 R02 Customer: Suzhou FuHong Electronjc InduslrialCo., Lld. Addres!: NO.89 WEIDU ROAD, WANGTINGTOWN, XIANGCHENG DlsTRlCT, SUZHOU, CHINA Report on ths submitred s.mplesald to be S.mple name: CoppeJ,shell Mod h/ Item/LoiNo.:/ Metarlal:/, Buyer: /, Suppli r: / TEST REPORT Dare: ocr.10, 2012 Samplo recaivsd d.te: Ocl. 08. 2012 Testins period: Ffom oct os, 20! 1o'O4r'10, 2012 '\l '..,, E9S!.s-Ecs!ed9!f As specified by dient, to determine ihe Lead, cadmlun, accordance with Dircctive 2002/95/EC {RoHS). Ec!!!s-ee$9!.: Testing ltem Mercury & Hexavalent Chrcmium content in the submitled sample in Measunng instrumeni I\4QL Lead (Pb) IEC 62321: 2008, s ction 9 ICP ES 2-'nglkg Cadmium (cd) EC62321: 2008, seclion I ICP-OES 2 mg/kg [4ercury (Hg) lec 623212008, seclron 7 tcp-oes 2 mg/kg Chromum (Cr\rl) IEC 623212008 Annex B 0.02m9/k9' Ieq r 0.02 mg/kg ree s to the MQL ofsampl extfaction liquid SsElcge!: -when tesled as speci{i d the submitted sample complied with the requirements of commission Decision ol 18 Aug 2005 amending Directjve 2002/95/Ec noiilied under document 2005/618/Ec ILS, PLEASE REFER TOTHE FOLLOWNG PAGE(S)*** signed lor and on behalfof Shenzhen AOV Tesling Technology Co., Ltd, Kunshan Brcncn caeateaaer: /blfil LiTingting, Maggie Chemic l Test Direcror **n*"oor, We-r k] n ooo,',*or44. Ylan Qi, lrickey SItEN2HEN AOV Tf SIING T CHNOI,O6Y CO.,I"TO.KUNSNAN BRANCTI /// \ Noll ne, J a,t 7tt) 9 't'o

AOV'*F#S,[ NO.: 4002R121008024-1 R02 TEST REPORT Oate:Od.10,2012 1. To Determiney'.ead, C dmium Contenli (Metal subslrate) I*redby (y'a04* Weigh ihe sample into Add ihe digestion solulioni the vessel is heated unlil the sample Add HrOruntilthe sample is clear Cooling the vess, nlter;washed and Rlled 10 the mark with distill d wat r. To Dete Content i retb.r sulit le). \. Weigh ihe sample The sample is digested in the microwave oven following a specific decomposrlon program Tested by lcp-oes Cooling the vessel, tiltei washed and filled lothe maik wilh dislilled water. Chromium Contenl (boiling- wat F xtlaclion): ([4etal Eubstrate) Take the (50i5) cm, sample in the beaker. Heat 50 ml of Olwater in the be6ker to boiling for 1o Remove lhe sample, and cool the beak r to room temperature, and do the coloreaction F;;1.- Test the sample solution and lhe 0.02 ng/kg standard solltion by uv-vls. SH NZH N AOV TESTITIG lccinology CO.,LTD.KUNSIIAN BSANCH (: Hotlrne 'tl)0 700 8600

nov'bpf,f,il NO.: 4002R121008024-1R02 5. To oetemine Hexavalenl Chromium Contonl in _.. -i\ : va'hu't' TEST REPORT Daie: Ocl.10, 2012 colorless and colored chromate coating on metats: iptating) lfthe lest result is positive, the sample is considered to have hexavalent chmmium Place 1-5 and the 0.02 mg/kg Boiling- water- extraotion procedu shall be used to lflhee is interference or it is hard to decide whetherlhe sample have lhe hexavalent 5.2 Boiling-wateF enradion sample in the beaker. Heat 50 mlof Dlwaier in the beaker to boiling for 10 min Remove the sample, and cool the beaker lo room temperalure, and do lhe coloreaction Test tne sample solution and lhe 0.02 mg/kg standad solulion by UV-VIS. Sample Delcriptlon: Code Sample Descndion 1-1 Substrate Plating Te3t R63ulb: Unit RoHS Limit Lead (Pb) msfts 1000 N.D. 10 Cadmium (Cd) mg/k9 100 N.D. N.O. Merorry (Hg) ms/kg 1000 N.D, N.D. Chromium {Crl,ll) m9/kg 1000 Negative Negative s8 NZh N AOV T SrtNG TECHNOlOSY CO,,tTD,TUNSHAI!ARANCH,.r H otlin e.100700 B6a0

nov'f"ff"qn No.: A002R1210o602:L1 R02 TEST REPORT -The new RoHS dircclive 2011/6tEU, on Jul. 21, 2011 come into forc, on Jan. 03, 2013lhe formal implementation, Direclive 2002r'95/EC ahall be repealed simultaneously. Sp cimens, which r Slested lo detemine Lead, Cadmium and Mercury Content, have been dissolved completely, -mg/kg=ppm, -N.D.=not i",,,,, ( The iested sample result is uncertain or neoatve., -"The te8t is bas d on lhe followins d!!{mplifi: maybe cannot stand lor the physical lrdh 6t s r Coppershell SH NZII AOVTIST n G TECHNOIOCV CO.,ITD.KUNSHAN AFANCH H otlin e 400 /00 8600

Test Report Number: SHAH0036227401 Applicant: ELSCHUKOM ELEKTROSCHUTZKOMPONENTENBAU Date: JAN 18, 2013 GM BH GEWERBESTRASSE 87,D-98669 VEILSDORF, GERMANY Sample Description: Two(2) pieces of submitted samples said to be : (1) Mixed all kinds of metal substrates. (2) Mixed all kinds of plating layers. Item Name : Silver Plated & Pure Silver Wires. Item No. : (B-1) 101.014 -. ---- silver plated copper wire Cu, Ag--% (B-2) 101.0131.---- pure silver wire Ag 1000 (B-3) 101.0123.0--- silver plated purest nickel wire Ni99.98%, Ag1% (B-4) 101.0182.0--- silver-copper alloy plated copper plated iron nickel alloy wire ElconD, AgCu5% (B-5) 101.0120.0--- silver plated constantan wire CuNi44, Ag5% (B-6) 101.0151.0--- silver plated copper - nickel 44 alloy wire CuNi44, Ag10% (B-7) 1050--31.-------- pure silver strips Ag 1000 pure Country Of Origin : Germany. ************************************************************************************************************************************************************ Tests Conducted: As requested by the applicant, for details refer to attached page(s). ************************************************************************************************************************************************************ To Be Continued Authorized by: For intertek testing services Ltd., Shanghai Jacob Lin General Manager Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上 海 天 祥 質 量 技 術 服 務 有 限 公 司 上 海 市 宜 山 路 801 號 金 陵 商 務 廣 場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Page 1 Of 5

Tests Conducted Test Report Number: SHAH0036227401 (A) Test result of RoHS Directive: Testing item Cadmium (Cd) content (mg/kg) Lead (Pb) content (mg/kg) Mercury (Hg) content (mg/kg) Chromium (VI)(Cr 6+ ) result (by boiling water extraction on metal) (mg/kg with 50cm 2 ) Testing item Cadmium (Cd) content (mg/kg) /Plating Lead (Pb) content (mg/kg) /Plating Mercury (Hg) content (mg/kg) /Plating Chromium (VI)(Cr 6+ ) result (by boiling water extraction on metal) (mg/kg with 50cm 2 ) /Plating Result (1) Result (2) Remark:mg/kg with 50cm 2 = milligram per kilogram with 50 square centimeter = not detected (B) RoHS Requirement: Restricted substances Cadmium (Cd) Lead (Pb) Mercury (Hg) Chromium (VI) (Cr 6+ ) Limits 0.01% (100 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) The above limits were quoted from RoHS Directive 2011/65/EU for homogeneous material. (C) Test method: Testing item Testing method Reporting limit Cadmium (Cd) content With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and 2 mg/kg determined by ICP-OES. Lead (Pb) content With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and 2 mg/kg determined by ICP-OES. Mercury (Hg) content With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and 2 mg/kg determined by ICP-OES. Chromium (VI) (Cr 6+ ) content (for With reference to IEC 62321 Edition 1.0: 2008, by boiling 0.02mg/kg with 50cm 2 metal) water extraction and determined by UV-VIS (in testing solution) Spectrophotometer. Date sample received: Jan.14, 2013 Testing period: Jan.14, 2013 To Jan.17, 2013 ************************************************************************************************************************************************************ To Be Continued Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上 海 天 祥 質 量 技 術 服 務 有 限 公 司 上 海 市 宜 山 路 801 號 金 陵 商 務 廣 場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Page 2 Of 5

Test Report Number: SHAH0036227401 Tests Conducted (D) Measurement flowchart: Test for Cd/Pb/Hg/Cr (VI)/PBBs/PBDEs contents Reference standard: IEC 62321 Edition 1.0: 2008 Sampling/grinding or cutting Cd/Pb/Hg Metal Cr 6+ Polymers / electronics PBBs/PBDEs Weigh sample and for different material, digest the sample with appropriate acid *1 Spot test Weigh sample and add alkaline solution Weigh sample and add organic solvent Positive *2 Confirm the tested samples are totally dissolved Yes Make up with deionized water No Get 50cm 2 samples Boiling water extraction Definite temp. Extraction Cool and filter the extract Soxhlet extraction or Solvent extraction Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by GC-MSD Analyzed by UV-VIS Remarks: *1: list of appropriate acid: Material Acid added for digestion Polymers HNO 3,HCL,HF,H 2O 2,H 3BO 3 Metals HNO 3,HCL,HF Electronics H NO 3,HCL,H 2O 2,HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. ************************************************************************************************************************************************************ To Be Continued Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上 海 天 祥 質 量 技 術 服 務 有 限 公 司 上 海 市 宜 山 路 801 號 金 陵 商 務 廣 場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Page 3 Of 5

Tests Conducted Test Report Number: SHAH0036227401 ************************************************************************************************************************************************************ To Be Continued Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上 海 天 祥 質 量 技 術 服 務 有 限 公 司 上 海 市 宜 山 路 801 號 金 陵 商 務 廣 場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Page 4 Of 5

Tests Conducted Test Report Number: SHAH0036227401 ************************************************************************************************************************************************************ End Of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上 海 天 祥 質 量 技 術 服 務 有 限 公 司 上 海 市 宜 山 路 801 號 金 陵 商 務 廣 場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Page 5 Of 5

Test Report Number : TWNC00294417 Applicant: Littelfuse Philippines Inc. Date : Jan 17, 2013 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Ni42Fe58MCuAg5% Element Part Number : 497226 (497xxx) Date Sample Received : Jan 11, 2013 Date Test Started : Jan 11, 2013 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0294417* Page 1 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00294417 Test Conducted (Ⅰ) Test Result Summary: Result Test Item Unit Test Method Silvery RL metal wire Heavy Metal Cadmium (Cd) content ppm With reference to IEC 62321: 2008, by microwave digestion and 2 determined by ICP-OES. Lead (Pb) content ppm With reference to IEC 62321: 2008, by microwave digestion and 2 determined by ICP-OES. Mercury (Hg) content ppm With reference to IEC 62321: 2008, by microwave digestion and 2 determined by ICP-OES. With reference to IEC mg/kg 62321: 2008, by boiling Chromium VI (Cr 6+ ) content with water extraction and Negative 0.02 50 cm 2 determined by UV-Vis Spectrophotometer. Remarks: ppm = parts per million based on weight of tested sample = mg/kg = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample mg/kg with 50cm 2 = milligram per kilogram with 50 square centimeter Negative = A negative test result indicated positive observation was not found at the time of Test. When the spot test showed a negative result, the boiling water extraction procedure shall be used to verify the result. Responsibility of Chemist: Kevin Liu/ Irene Chiou Date Sample Received : Jan 11, 2013 Test Period : Jan 11, 2013 To Jan 15, 2013 (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0294417* Page 2 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00294417 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Metal Cr 6+ Polymers / Electronics For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Weigh sample and add alkaline solution Definite temp. extraction Make up with deionized water Boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS *THJ0294417* Page 3 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00294417 Test Conducted Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0294417* Page 4 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00294417 Test Conducted Photo *THJ0294417* Page 5 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Intertek Consumer Goods GmbH Würzburger Straße 152 90766 Fürth Polyfil AG Gina Gregorio Oberallmendstrasse 20A 6300 Zug / Switzerland Fürth, 2012-12-19 Test report No. FUHL1236938 Testing of a material sample according to the RoHS directive 2011/65/EC Sample description: Ni42Fe58MCuMSn wire; part no. 4500237197; batch 0380.6025 Arrival in lab: 2012-012-04; Period of XRF analysis incl. sample preparation and photo documentation: 2012-12-07 2012-12-10 Head of Inorganic Lab: Claudia List Copying this test report is permitted only in agreement with the contracted lab. The test results refer only to the tested item. This report consists of 6 page(s). The test methods signed with * are not listed in the attachment of the accreditation certificate. Conclusion based on tested item Test order Status testing according to the RoHS directive 2011/65/EC conform Please see overview of test results - Test results see next pages - Intertek Consumer Goods GmbH Tel.: +49 911 74075 0 Sitz Fürth Geschäftsführer Würzburger Straße 152 Fax: +49 911 74075 30 Amtsgericht Fürth, HRB 5756 Kay Grönhardt 90766 Fürth, Germany cg.germany@intertek.com USt-IdNr. DE169317871 Rainer Mast Durch die DAkkS nach DIN EN ISO/IEC 17025 akkreditiertes Prüflaboratorium Die Akkreditierung gilt für die in der Urkunde aufgeführten Prüfverfahren.

Page 2 of 6 page(s) of our test report No. FUHL1236938 dated 2012-12-19 Sample description: Ni42Fe58MCuMSn wire; part no. 4500237197; batch 0380.6025 nm = non Metal M = Metal cm = composite Material List of component parts: Sample No. Part No. Material Description 236938 1 M Ni42Fe58MCuMSn wire; part no. 4500237197; batch 0380.6025 Intertek Consumer Goods GmbH Tel.: +49 911 74075 0 Sitz Fürth Geschäftsführer Würzburger Straße 152 Fax: +49 911 74075 30 Amtsgericht Fürth, HRB 5756 Kay Grönhardt 90766 Fürth, Germany cg.germany@intertek.com Ust-IdNr. DE169317871 Rainer Mast

Page 3 of 6 page(s) of our test report No. FUHL1236938 dated 2012-12-19 Sample description: Ni42Fe58MCuMSn wire; part no. 4500237197; batch 0380.6025 Comment LOD = Limit of Detection BL = Below Limit OL = Over Limit X = Inconclusive, further test necessary σ = Standard deviation CS = Composite sample Remark: Results were obtained by EDXRF for primary screening. Additional chemical testing using ICP (for Cd, Pb), AAS (for Hg), IC-UC/VIS (for CrVI) and GC/MS (for PBBs/PBDEs) are recommended, if the concentration exceeds the below warning value according to IEC 62321. Element Unit non - metal metal Cd mg / kg BL (70-3σ) < X < (130+3σ) OL BL (70-3σ) < X < (130+3σ) OL Pb mg / kg BL (700-3σ) < X < (1300+3σ) OL BL (700-3σ) < X < (1300+3σ) OL Hg mg / kg BL (700-3σ) < X < (1300+3σ) OL BL (700-3σ) < X < (1300+3σ) OL Br mg / kg BL (300-3σ) < X -- Cr mg / kg BL (700-3σ) < X BL (700-3σ) < X Element Unit composite material Cd mg / kg LOD < X < (150+3σ) OL Pb mg / kg BL (500-3σ) < X < (1500+3σ) OL Hg mg / kg BL (500-3σ) < X < (1500+3σ) OL Br mg / kg BL (250-3σ) < X Cr mg / kg BL (500-3σ) < X Intertek Consumer Goods GmbH Tel.: +49 911 74075 0 Sitz Fürth Geschäftsführer Würzburger Straße 152 Fax: +49 911 74075 30 Amtsgericht Fürth, HRB 5756 Kay Grönhardt 90766 Fürth, Germany cg.germany@intertek.com Ust-IdNr. DE169317871 Rainer Mast

Page 4 of 6 page(s) of our test report No. FUHL1236938 dated 2012-12-19 Sample description: Ni42Fe58MCuMSn wire; part no. 4500237197; batch 0380.6025 1. XRF screening Method: XRF according to IEC 62321:2008* Sample No. Part No. Pb Hg Cd Cr total Br Status 236938 1 BL BL BL BL -- conform Comment: Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI (Cr VI) Polybrominated Biphenyle (PBBs) Polybrominated Diphenyl ether (PBDEs) RoHS-limit value 1000 mg/kg 1000 mg/kg 100 mg/kg 1000 mg/kg 1000 mg/kg 1000 mg/kg - Flow charts see next page(s) - Intertek Consumer Goods GmbH Tel.: +49 911 74075 0 Sitz Fürth Geschäftsführer Würzburger Straße 152 Fax: +49 911 74075 30 Amtsgericht Fürth, HRB 5756 Kay Grönhardt 90766 Fürth, Germany cg.germany@intertek.com Ust-IdNr. DE169317871 Rainer Mast

Page 5 of 6 page(s) Test procedure samples metallic materials, YES screening by XRF? NO sample uniform? YES NO non-destructive sample preparation mechanical sample preparation YES screening procedure by XRF NO meets limits? further testing? YES NO pass entity based conforming sample fail entity based non conforming sample polymer materials, electronics (PCB / component) mechanical sample preparation chemical test procedure (verification) various methods (please see verification test procedure below) YES pass entity based conforming sample meets limits? fail NO entity based non conforming sample Intertek Consumer Goods GmbH Tel.: +49 911 74075 0 Sitz Fürth Geschäftsführer Würzburger Straße 152 Fax: +49 911 74075 30 Amtsgericht Fürth, HRB 5756 Kay Grönhardt 90766 Fürth, Germany cg.germany@intertek.com Ust-IdNr. DE169317871 Rainer Mast

Page 6 of 6 page(s) Verification test procedure Sample Preparation Sample Measurement Acid digestion with microwave / hotplate Pb/Cd/Hg PBBs/PBDEs Cr 6+ Sample solvent extraction Non-metallic material Metallic material Solution Filtration Residue Total digestion ICP-OES/AAS DATA Concentration/ Dilution of extraction solution Filtration GC/MS DATA Alkaline extraction Adding extraction solution Alkaline extraction Heating to 90~95 C for extraction Filtration and ph adjustment Adding 1,5- diphenylcarbazide for color development Positive Spot test Boiling water extraction Negative Adding 1,5- diphenylcarbazide for color development A red color indicates the presence of Cr 6+ If necessary, confirm with UV-VIS or IC-UV/VIS UV-VIS or IC-UV/VIS DATA DATA Intertek Consumer Goods GmbH Tel.: +49 911 74075 0 Sitz Fürth Geschäftsführer Würzburger Straße 152 Fax: +49 911 74075 30 Amtsgericht Fürth, HRB 5756 Kay Grönhardt 90766 Fürth, Germany cg.germany@intertek.com Ust-IdNr. DE169317871 Rainer Mast

Test Report Number : TWNC00256916 Applicant: Littelfuse Philippines Inc. Date : May 16, 2012 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Ink Part Number : 425672 Date Sample Received : May 10, 2012 Date Test Started : May 10, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 114 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Page 1 of 9

Number : TWNC00256916 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Result (ppm) Black Paste Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 114 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Page 2 of 9

Number : TWNC00256916 Test Conducted (Ⅰ) Test Result Summary : Test Item Phthalates Di(2-ethylhexyl) Phthalate (DEHP) Dibutyl Phthalate (DBP) Benzyl Butyl Phthalate (BBP) Others Hexabromocyclododecane (HBCDD) Result (ppm) Black Paste Remarks: ppm = Parts per million based on wet weight of tested sample = mg/kg = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received : May 10, 2012 Test Period : May 10, 2012 To May 16, 2012 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 114 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Page 3 of 9

Number : TWNC00256916 Test Conducted (Ⅲ) Test Method: Test Item Test Method Reporting Limit With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) microwave digestion until the tested content samples are totally dissolved and 2 ppm determined by ICP-OES. Lead (Pb) content With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and 2 ppm Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Phthalates Hexabromocyclodode cane (HBCDD) determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by Ion Chromatograph. With reference to EN 14372: 2004, by solvent extraction and determined by GC-MS. With reference to USEPA 3540C, by solvent extraction and determined by GC-MSD. Remark: Reporting limit = Quantitation limit of analyte in sample 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm 10 ppm 10 ppm Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 114 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Page 4 of 9

Number : TWNC00256916 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 For metal part Sample preparation For non-metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Metal Cr 6+ Polymers / electronics PBBs/PBDEs For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Weigh sample and add alkaline solution Definite temp. extraction Weigh sample and add organic solvent By Soxhlet extraction or Solvent extraction Make up with deionized water By boiling water extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 114 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Page 5 of 9

Number : TWNC00256916 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 114 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Page 6 of 9

Number : TWNC00256916 Test Conducted (Ⅳ) Measurement Flowchart: Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 114 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Page 7 of 9

Number : TWNC00256916 Test Conducted (Ⅳ) Measurement Flowchart: Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 114 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Page 8 of 9

Number : TWNC00256916 Test Conducted Photo Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 114 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Page 9 of 9

Test Report Number : TWNC00289673 Applicant: Littelfuse Philippines Inc. Date : Dec 13, 2012 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Solder Part Number : 692481 Date Sample Received : Dec 06, 2012 Date Test Started : Dec 07, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0289673* Page 1 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00289673 Test Conducted (Ⅰ) Test Result Summary : Test Item Result (ppm) Silvery metal Heavy Metal Cadmium (Cd) content Lead (Pb) content 260 Mercury (Hg) content Chromium VI (Cr 6+ ) content (mg/kg with 50cm 2 ) Negative (< 0.02) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg = Not detected < = Less than mg/kg with 50cm 2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. Responsibility of Chemist : Irene Chiou / Kevin Liu Date Sample Received : Dec 06, 2012 Test Period : Dec 07, 2012 To Dec 12, 2012 (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0289673* Page 2 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00289673 Test Conducted (Ⅲ) Test Method: Test Item Test Method Reporting Limit With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) microwave digestion until the tested content samples are totally dissolved and 2 ppm determined by ICP-OES. Lead (Pb) content With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and 2 ppm Mercury (Hg) content Chromium VI (Cr 6+ ) content determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis Spectrophotometer. Remark: Reporting limit = Quantitation limit of analyte in sample 2 ppm 0.02 mg/kg with 50cm 2 *THJ0289673* Page 3 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00289673 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Metal Cr 6+ Polymers / Electronics For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Weigh sample and add alkaline solution Definite temp. extraction Make up with deionized water Boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS *THJ0289673* Page 4 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00289673 Test Conducted Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0289673* Page 5 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00289673 Test Conducted Photo *THJ0289673* Page 6 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Test Report Number : TWNC00296620 Applicant: Elschukom Elektroschutzkomponentenbau Date : Jan 30, 2013 GmbH Gewerbestrasse 87, D-98669 Veilsdorf, Germany Sample Description: One (1) group of submitted samples said to be : Sample Description :Tin plated Wires Style / Item No. :Please see page two to three. Country of Origin :Germany Date Sample Received :Jan 23, 2013 Date Test Started :Jan 23, 2013 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0296620* Page 1 of 8 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Test Report Number : TWNC00296620 Sample Description: Style / Item No. : (A-1)101--271.0--- tin plated copper wire Cu, Sn--% (A-2)101--283.0--- tin plated, copper plated copper nickel alloy wire Elcon30, Sn--% (A-3)101--272.0--- tin plated, copper plated steel wire ElconF, Sn--% (A-4)101--281.0--- tin plated, copper plated iron nickel alloy wire ElconD, Sn--% (A-5)101--221.0--- tin plated copper nickel alloy wire - CuNi44, Sn--% (A-6)101--24-.0--- tin plated, silver plated copper wire Cu, Ag--%, Sn--% (A-7)101--257.0--- tin plated brass wire Cu80Zn20, Sn--% Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0296620* Page 2 of 8 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Test Report Number : TWNC00296620 Sample Description: Style / Item No. : (A-9)101--234.0--- - tin plated silver copper alloy wire AgCu90, Sn--% (ElCu90, Sn--%) (A-10)101--255.---- tin plated copper zinc alloy wire Cu70Zn30, Sn--% (A-11)101--229.---- tin plated copper nickel alloy wire CuNi12, Sn--% (A-12)101--235.---- tin plated silver copper alloy wire Ag72Cu28, Sn--% (A-13)101--231.---- tin plated silver wire Ag1000, Sn--% (A-14)101--236.---- tin plated silver copper alloy wire Ag45Cu55, Sn--%(AgCu55, Sn) (A-15)101--266.---- tin plated silver copper alloy wire AgCu70, Sn--%(ElCu70, Sn) (A-16)101--238.---- tin plated silver copper alloy wire AgCu80, Sn--%(Elcu80, Sn) (A-17)101--228.0--- tin plated tungsten wire W, Sn Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0296620* Page 3 of 8 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00296620 Test Conducted (Ⅰ) Test Result Summary: Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Test Item Unit Test Method Chromium VI (Cr 6+ ) content ppm ppm ppm mg/kg with 50 cm 2 With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by boiling water extraction and determined by UV-Vis Spectrophotometer. Result Mixed all kinds of metal wire RL 2 37 2 2 Negative (#) 0.02 Remarks: ppm = parts per million based on weight of tested sample = mg/kg = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample mg/kg with 50cm 2 = milligram per kilogram with 50 square centimeter Negative = A negative test result indicated positive observation was not found at the time of Test. When the spot test showed a negative result, the boiling water extraction procedure shall be used to verify the result. # = Due to the insufficient sample area, reduced total sample surface of 10 cm 2 was used and the dilution factor was adjusted accordingly. Responsibility of Chemist: Kevin Liu/ Irene Chiou Date Sample Received : Jan 23, 2013 Test Period : Jan 23, 2013 To Jan 29, 2013 *THJ0296620* Page 4 of 8 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00296620 Test Conducted (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0296620* Page 5 of 8 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00296620 Test Conducted (Ⅲ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Metal Cr 6+ Polymers / Electronics For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Weigh sample and add alkaline solution Definite temp. extraction Make up with deionized water Boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS *THJ0296620* Page 6 of 8 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00296620 Test Conducted Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3,HCl,HF,H 2 O 2,H 3 BO 3 Metals HNO 3,HCl,HF Electronics HNO 3,HCl,H 2 O 2,HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0296620* Page 7 of 8 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410

Number : TWNC00296620 Test Conducted Photo *THJ0296620* Page 8 of 8 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全 國 公 證 檢 驗 股 份 有 限 公 司 11492 台 北 市 內 湖 區 瑞 光 路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410