Meter Technician Certification Exam



Similar documents
INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

STORED PRESSURE STAINLESS STEEL

Finding and Fixing Leaks

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Installation, Maintenance, & Repair Series 4000B/LF4000B

M A N U A L

Model 1210C Battery Powered Pump Shown. Description

Wiper Motor Marinco 2.5. Installation Instructions

Calibration of Volumetric Glassware

UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures

DO NOT attempt to repair hub and wheel bearing assembly.

Step-by-step instructions:

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Watts Pure Water Systems

orlando OWNER S MANUAL

CYLINDER LEAKAGE CHECK (Compression)

Rental Services Temporary Cooling - Flexible Water Hose

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT

FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS

Complete Systems & Parts Automatic Oiler & Grease Bank

TECHNICAL DATA. Dry 122a. November 12, 2013

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Trouble Shooting. Pump

Your safety and the safety of others are very important.

Diesel Care & Performance Inc Care is at the center of everything we do

Fire Hydrant Troubleshooting

INSTALLATION INSTRUCTIONS


Before repairing your toilet, you must determine

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

Flushing and Cleaning the A/C System

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

ARVINMERITOR UNITIZED FRONT WHEEL HUB INSPECTION AND MAINTENANCE

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Daniel Venturi Tubes and Flow Nozzles Brochure

PLUMBING CARE AND REPAIR

Important Information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Boiler and Burner Cleaning and Servicing Specifications

TUTORIAL. REbUILdING. front CALIpER O-RING CONVERSION CORVETTE Part #: HT-1

Fish Grader User Manual

PRESSURE REDUCING CONTROL VALVE

Toroidal Conductivity Sensor

SELF-STEERING AXLE TABLE OF CONTENTS

Rebuild Instructions for and Transmission

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

San josé OWNER S MANUAL

Federal Wage System Job Grading Standard for Heating and Boiler Plant Equipment Mechanic, Table of Contents

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

SANITARY SEWER SPECIFICATIONS

HYDRAULIC TABLE CART 500-LB.

INSTALLATION INSTRUCTIONS FOR VW MK5

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

Float and Thermostatic Traps Series H, C and X

Drive shaft, servicing

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

UNIFORM DATA COLLECTION PROCEDURES

IMPACT SPRINKLER TROUBLESHOOTING GUIDE

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

AIR LINE VALVES AND GAUGES

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

User s Manual Laminar Flow Elements

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE AUTO 220 INTERNAL COMBUSTION ENGINES

Flow Measurement Options for Pipeline and Open Channel Flow

DryWeight BulkVolume

GAS CYLINDER SAFETY. 2. GRADES OF GASES BOC have divided the gases that they supply into 3 grades.

AXLE SHAFTS - FRONT Pontiac Bonneville MODEL IDENTIFICATION DESCRIPTION & OPERATION TROUBLE SHOOTING REMOVAL & INSTALLATION

RULE # 1 is DON T mess with things that you don t know anything about! (Take them to a pro & pay them to fix it)

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

Pump Skid Fabrication for Magnetic Coupling. Rick Soltis Chief Mechanic City of Bedford

This kit may void factory warranty please check with manufacturer.

REPAIR AND MAINTENANCE MANUAL

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

ROUGHNECK II Pumpless Drain

SINGLE RANGE DS METERS Operation Instructions

DANA 30 MANUAL HUB CONVERSION KIT

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

World-Class Oil Sampling It is Possible

Backup Fuel Oil System Decommissioning & Restoration Plan

Multiport Spill Containment with Defender Spill Containers

Diesel Fuel Systems. Injection Nozzles

TUTORIAL. REbUILdING. REAR CALIpER O-RING CONVERSION CORVETTE Part #: HT-2

Model 5600 & 5600 Econominder

Daily Inventory and. Statistical Inventory Analysis. Daily Inventory and Statistical Inventory Analysis (SIA) are inventory control

E ER TITAN PRODUCTS. Foundation Repair

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

METHOD OF TEST FOR SAMPLING AND TESTING CRUMB RUBBER MODIFIER

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Standard Hydraulic Piping Flushing Procedure

SERIES 238 WINDOWS. NOTE: Read instructions completely before attempting any installation.

Quartz Top Installation Instructions See separate installation instructions for installing your new Vanity.

Trouble shooting guide

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Mercedes

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

The On-Board Refueling Vapor Recovery (ORVR) Evaporative Emission (EVAP) system.

Transcription:

Meter Technician Certification Exam Revised September 2012 Version 12.0 This exam is designed to test the knowledge of meter technicians in order to attain certification to check the calibration of portable meters. It is necessary that they demonstrate an understanding of the operation, maintenance, repair, and calibration procedures for varying types of portable milk meters used in the marketplace. This exam can also be used as a review by meter technicians in preparation for the Quality Certification Services Inc. recertification audit. Meter technician name: Meter technician address: Meter technician phone number: Meter technician email address: Meter center used: Meter technician trainer: Exam date: Exam grade: Meter Technician Exam Version 12.0 Page 1 of 11

METER RIG QUESTIONS 1. When making changes to the meter center or meter technicians performing calibration and repair services, how soon should the auditor be notified? a. At the next regularly scheduled meter center audit b. At the next regularly scheduled field service audit c. Within 30 days d. Within 6 months 2. There are seven changes to a meter center that will require a discretionary audit. They are? a. b. c. d. e. f. g. 3. The correct vacuum level for using either the standard or fast-flow water test methods is: a. 14 Hg with a range of 13.5 14.5 Hg b. 15 Hg with a range of 14.5 15.5 Hg c. 16 Hg with a range of 15.5 16.5 Hg 4. The devices approved for determining the initial water volume for the water testing methods include: a. Accurate scales only b. DHI approved weigh jars only c. Volumetric flasks only d. Accurate scales or volumetric flasks only e. Accurate scales, DHI approved weigh jars, or volumetric flasks 5. The initial water volume required for water testing a meter is: a. 16.0 liters, 16 kilograms, or 35.3 lbs b. 17.0 liters, 17 kilograms, or 37.4 lbs c. Variable as long as the meter reads within 3% d. 15.5 liters or 15.5 kilograms 6. The maximum tolerance for vertical alignment (tilt) of the milk meter is: a. +/-3% b. +/-5% c. +/-7% Meter Technician Exam Version 12.0 Page 2 of 11

d. +/-6% 7. The maximum tolerance for horizontal alignment of the Waikato milk meter is: a. +/-3% b. +/-5% c. +/-7% d. +/-6% 8. What type of reading would you expect if the meter is leaning too far forward? a. Heavy b. Light c. Won t affect the meter at all GENERAL METER QUESTIONS 9. Gaskets and o-rings must provide proper sealing of the meter. Why? 10. Flask printing is guaranteed to remain legible under recommended washing, care, and use procedures. 11. The mixture of milk and air during the milking process are critical to the operation of volumetric meters. 12. An air leak in a volumetric meter will cause the meter to read: a. Heavy b. Light 13. Excess exposure to causes premature yellowing of the polysulfone plastics. 14. To ensure proper cleaning, more water and cleaning solutions may need to be added during the CIP wash-up when meters are in the barn. Why? Meter Technician Exam Version 12.0 Page 3 of 11

15. Rubber components do not absorb milk fat and therefore do not need to be checked as part of the routine maintenance of the meter. 16. Meter manufacturers recommend checking meters and replacing rubber gaskets, o-rings, and hoses at least once a year with model specific service kits. 17. Taking the meters apart and scrubbing every part with a stiff brush is a great way to clean them and maintain their calibration accuracy. 18. If an unusual or disproportionate amount of meters are failing calibration, where should you focus your attention in order to solve the problem? a. Meter b. Flask Calibration Markings c. Meter Calibration Rig d. Field Technician 19. Since all meters operate with the same basic principle, a certified meter technician is authorized to check the calibration of any and all meters: 20. What is the ONLY type of lubricant that can be used on the Tru-Test meter s O-rings and valve assemblies? a. White grease b. WD40 c. Food Grade Silicon d. Bearing grease e. 3-in-1 Oil 21. Which 3 chemicals or compounds will damage the polysulfone meter plastics? a. Silicon b. Hydrocarbon based compounds c. Petro-chemicals d. Alcohol e. Soap Meter Technician Exam Version 12.0 Page 4 of 11

METER CALIBRATION DOCUMENTATION AND QUALITY CERTIFICATION 22. You calibrate a meter and get the following results: 1 ST run 34.5, 2 ND run 35.0, 3 RD run 37.5, and 4 TH run 37.5. What calibration(s) do you need to record for the calibration record to meet the CDCB guidelines? a. 1 ST ONLY b. 3 RD AND 4 TH c. 4 TH ONLY d. 1 ST AND 4 TH e. ALL 23. At the completion of a successful calibration, the meter must be marked with the following information: a. Meter center name only b. Meter technician name only c. Meter technician name and year checked d. Meter center name and year checked 24. According to the CDCB guidelines, calibration check intervals for portable meters must not exceed: a. 300 days b. 365 days c. 400 days d. 425 days 25. A Foss, Tru-Test, or Waikato meter is checked for calibration using the Standard Water Test Method and the reading is 35.5 lbs on the first run. Has this meter passed the CDCB tolerance requirements? a. Yes b. No 26. A Foss, Tru-Test, or Waikato meter is checked for calibration using the Standard Water Test Method and the flask reading is 37.5 lbs for the first run. Has this meter passed the CDCB tolerance requirements? a. Yes b. No 27. A Foss, Tru-Test, or Waikato meter is checked for calibration using the Standard Water Test Method. The readings are 35.5 lbs for the first run and 36.0 lbs for the second. Has this meter passed the CDCB tolerance requirements? a. Yes b. No 28. According to the CDCB guidelines, new meters with manufacture dates over 365 days ago must be checked for calibration before being placed in service for the first time: Meter Technician Exam Version 12.0 Page 5 of 11

29. When documenting the calibration check results from a water test, the flask reading should be taken: a. At the bottom of the water meniscus b. At the top of the water meniscus c. In the middle of the meniscus STANDARD FLOW TEST SPECIFIC 30. In what two ways can you verify the correct size of the air admission orifice required by the Standard Water Test Method? a. 18 gauge needle b. 16 gauge needle c. Paper clip d. Thin wire e. #60 drill bit 31. The water flow restrictor required by the Standard Water Test Method must produce a flow rate of about: a. 8.0 lbs / minute b. 10.0 lbs/minute c. 18.2 lbs/minute d. 36.4 lbs/minute 32. The target time for checking the calibration of meters using the Standard Water Test Method is: a. 55-60 seconds b. 1 minute, 8 seconds c. 4 minutes, 34 seconds d. 3 minutes, 30 seconds 33. The air admission orifice required by the Standard Water Test Method must be located: a. 12 24 from the meter inlet b. 24 36 from the meter inlet c. More than 36 from the meter inlet d. Wherever you can find a spot FAST-FLOW TEST SPECIFIC 34. Air bubbles in the fast-flow calibration lines will not cause a calibration error in the Tru-Test meters. Meter Technician Exam Version 12.0 Page 6 of 11

35. When using the Fast-Flow Water Test Method, the distance from the restrictor inlet to the top of the flask is: a. 60 b. 63 c. 64.5 +/- 1/2 d. Irrelevant as long as the inlet pipe is straight 36. The target time for checking the calibration of STANDARD BORE Tru-Test meters using the Fast-Flow Water Test Method is: a. 55-65 seconds b. 1 minute, 8 seconds c. 4 minutes, 34 seconds 37. The target time for checking the calibration of WIDE BORE Tru-Test meters using the Fast-Flow Water Test Method is: a. 55-65 seconds b. 1 minute, 8 seconds c. 4 minutes, 34 seconds TRU-TEST METER SPECIFIC QUESTIONS 38. The nozzle is very sensitive to damage or blockage and may cause a meter to not calibrate correctly. 39. Calibrated flasks from different Tru-Test meter models are identical and are interchangeable between models. 40. Name 3 parts of the meter, that if cracked or damaged, could cause abnormal meter readings. 1. 2. 3. 41. The valves on the milk meters should be left in the Milking position between milkings. 42. Meter parts are 100% interchangeable and therefore do not require a calibration check following replacement of caps or nozzles. Meter Technician Exam Version 12.0 Page 7 of 11

43. All Tru-Test Meter parts are interchangeable and checked at the factory, and therefore do not require a calibration check following replacement of a cap, flask body or nozzle. 44. The methods of water testing that are approved for use with the Tru-Test meter are: a. Standard and Dual-Meter Water Test Methods only b. Standard, Dual-Meter, and Fast-Flow Water Test Methods c. Standard, Dual-Meter, Fast-Flow, and Volume Test Methods d. Standard, Dual-Meter, Fast-Flow, Volume, and Weight Test Methods 45. Which of the following measuring principles best describes the Tru-Test meter operation: a. Weight b. Volumetric 46. The Mini-Test and Mini-Manager meters have recently been approved for use in herds submitting records to AIPL: 47. Meter Caps, sleeve funnels, or nozzles that have become slightly worn, chipped or cracked will not affect the calibration of a meter. 48. Tru-Test meters are checked for calibration at the factory: TRU-TEST AUTO SAMPLERS ONLY 49. In order to verify that an air leak is coming from the flask or caused by the auto-sampler, simply pinch the tubing and check for bubbles to help isolate the cause. 50. The auto-sampler should be checked during calibration to ensure adequate sample amounts. Meter Technician Exam Version 12.0 Page 8 of 11

WAIKATO METER SPECIFIC QUESTIONS 51. Name 3 parts of the meter, that if cracked or damaged, could cause abnormal meter readings. 1. 2. 3. 52. The methods of water testing that are approved for use with the Waikato MK 5 meter are: a. Standard and Dual-Meter Water Test Methods only b. Standard, Dual-Meter, and Fast-Flow Water Test Methods c. Standard, Dual-Meter, Fast-Flow, and Volume Test Methods d. Standard, Dual-Meter, Fast-Flow, Volume, and Weight Test Methods 53. Waikato MK 5 meters are checked for calibration at the factory: 54. Which of the following measuring principles best describes the Waikato MK 5 meter operation: a. Weight b. Volumetric 55. According to the CDCB guidelines, new Waikato MK 5 meters must be checked for calibration before being placed in service for the first time: 56. Air bubbling in the meter flask may be caused by worn 3-way taps: 57. What must be done when converting from a 65 lb flask to a 92 lb flask? a. Remove the steel ball b. Snip off the lug on the ball cage assembly c. Replace the cover 58. Flask bungs for the Waikato MK 5 meter are interchangeable between the 65 lb and 92 lb models: Meter Technician Exam Version 12.0 Page 9 of 11

59. With only three parts to interchange, a simple process of elimination is used to recalibrate the milk meter. What three parts does the manufacturer suggest you should change? 1. 2. 3. 60. With the exception of the flask, bungs, and ball cage housing, parts are interchangeable between the 65 lb and 92 lb models: 61. The three parts that may affect calibration of the meter and must be replaced by a certified meter technician are the flask, cover, and base assembly: 62. Snipping off the end of the 3-way tap is an acceptable way to improve sampling speed. 63. While calibrating meters, you see air bubbling coming from the bottom of the flask. What is the cause, and how do you correct it? a. 3-way tap is worn, dry, or not properly seated b. replace, wet, or properly seat 3 way tap 64. When converting the MK V to a SPEEDSAMPLER meter it is not necessary to recalibrate the meter after all the components are changed. 65. Is it possible to use the wash cap to replace a sample vial during the calibration? 66. What are the three main parts when making a repair that would make it necessary to recalibrate a SPEEDSAMPLE or MKV? a. Cover b. SpeedSampler Meter Technician Exam Version 12.0 Page 10 of 11

c. Base assembly d. Flask e. Bung 67. The allowed limits to calibrate a SPEEDSAMPLER of MK V with only one run are: a. 35.0 to 38.0 b. 35.5 to 37.5 c. 36.0 to 37.0 68. Factory specifications require you to install service kits how often? Please choose two a. Every other year b. Every year c. Once every three years d. As needed 69. When converting a MK V to a SPEEDSAMPLER you can use the same lower valve housing. Meter Technician Exam Version 12.0 Page 11 of 11