PCB Component Placement Inspection



Similar documents
Optimet 3D Dental Multi-Facet Scanner Attainable Accuracy for Dental Application Cases

3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY

Making Better Medical Devices with Multisensor Metrology

RIEGL VZ-400 NEW. Laser Scanners. Latest News March 2009

Types of 3D Scanners and 3D Scanning Technologies.

Optical Digitizing by ATOS for Press Parts and Tools

Machine Tool Inspection & Analyzer solutions

ENGINEERING METROLOGY

Synthetic Sensing: Proximity / Distance Sensors

CNC-STEP. "LaserProbe4500" 3D laser scanning system Instruction manual

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Pipeline External Corrosion Analysis Using a 3D Laser Scanner

Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center

Mounting Instructions for SP4 Power Modules

SPI HS70. Remote Control of Multiple Lines with RMCworks. Systematic Process Management by Inspection Spec Server

BGA - Ball Grid Array Inspection Workshop. Bob Willis leadfreesoldering.com

BARE PCB INSPECTION BY MEAN OF ECT TECHNIQUE WITH SPIN-VALVE GMR SENSOR

PreciTrack3D GmbH. PRECI 3D TRACK PRECI 3D GUN PRECI 3D SCAN PRECI 3D ROBOGUN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRODUCTS

D/N VANDAL RES. VARI-FOCAL IR DOME CAMERA

3D SCANNING SOLUTION FOR PIPELINE INTEGRIT Y ASSESSMENT!

Holes & Selective Laser Sintering

Development of a Design & Manufacturing Environment for Reliable and Cost-Effective PCB Embedding Technology

FRT - setting the standard

VECTORAL IMAGING THE NEW DIRECTION IN AUTOMATED OPTICAL INSPECTION

3D laser removal and texturing in a new dimension

THICKNESS MEASUREMENT THICKNESS

Inspection of diffusely reflecting surfaces

Encoders for Linear Motors in the Electronics Industry

9. Force Measurement with a Strain gage Bridge

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

How To Measure Contactless Measurement On A Robot

ZEISS T-SCAN Automated / COMET Automated 3D Digitizing - Laserscanning / Fringe Projection Automated solutions for efficient 3D data capture

Advantages of digital servo amplifiers for control of a galvanometer based optical scanning system

Collision Prevention and Area Monitoring with the LMS Laser Measurement System

TAGARNO AS Sandøvej Horsens Denmark Tel: Mail: mail@tagarno.com

D/N VANDAL RES. VARI-FOCAL DOME CAMERA

LIST OF CONTENTS CHAPTER CONTENT PAGE DECLARATION DEDICATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK

Application Report: Running µshape TM on a VF-20 Interferometer

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

T-REDSPEED White paper

D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

A receiver TDC chip set for accurate pulsed time-of-flight laser ranging

Full Waveform Digitizing, Dual Channel Airborne LiDAR Scanning System for Ultra Wide Area Mapping

Aspocomp, PCBs for Demanding Applications

MRC High Resolution. MR-compatible digital HD video camera. User manual

Computer Vision. Image acquisition. 25 August Copyright by NHL Hogeschool and Van de Loosdrecht Machine Vision BV All rights reserved

INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS. Published: April 1999

Dev eloping a General Postprocessor for Multi-Axis CNC Milling Centers

5-Axis Test-Piece Influence of Machining Position

Sensori ottici e laser nelle applicazioni industriali

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

PRECISION, RELIABILITY, SIMPLICITY. simeda. customized. & solutions. Digital performance

High speed 3D capture for Configuration Management DOE SBIR Phase II Paul Banks

Atomic Force Microscope and Magnetic Force Microscope Background Information

3D SCANNING: A NEW APPROACH TOWARDS MODEL DEVELOPMENT IN ADVANCED MANUFACTURING SYSTEM

THE OPTICAL CMM 3D SCANNERS FOR INDUSTRIAL APPLICATIONS

OPERATION MANUAL INFRARED THERMOMETER

3D Electroform Stencils for Two Level PCB

HIGH-PERFORMANCE INSPECTION VEHICLE FOR RAILWAYS AND TUNNEL LININGS. HIGH-PERFORMANCE INSPECTION VEHICLE FOR RAILWAY AND ROAD TUNNEL LININGS.

ADVANCED DIRECT IMAGING. by ALTIX

Automatic Wheel Profile Measuring Device for Tramway Vehicles

Mercury TM 1500P PCB-Mount Digital Encoders

WW12X, WW08X, WW06X, WW04X ±1%, ±5% Thick Film Low ohm chip resistors

SCS Directory Accreditation number: SCS 0115

REGISTRATION OF LASER SCANNING POINT CLOUDS AND AERIAL IMAGES USING EITHER ARTIFICIAL OR NATURAL TIE FEATURES

Sensor/Raft Metrology Status

A Simple Guide To Understanding 3D Scanning Technologies

Single Mode Fiber Lasers

Optical Methods of Surface Measurement

DS6000. Advanced Dental Scanner & CAD Software. Crowns, Bridges Wax-ups Implant Bridges and Bars High Accuracy Scan & Design

Solution Guide III-C. 3D Vision. Building Vision for Business. MVTec Software GmbH

"Bringing Next Generation Imaging Technologies"

INDUSTRIAL VISION. Don Braggins, UK Industrial Vision Association

Injection moulding and modelling on a micro scale

Removing chips is a method for producing plastic threads of small diameters and high batches, which cause frequent failures of thread punches.

Precision Work on the Human Eye

FRC Series 35mm Diameter Reflectors for SEOUL SEMICONDUCTOR A3 (Acriche) and P7LEDs

Point cloud processing - scanning, analysing and validating

Non-Contact Vibration Measurement of Micro-Structures

Powering Integrated Circuits (ICs), and managing ripple voltage as it relates

National Performance Evaluation Facility for LADARs

Laser Ranging to Nano-Satellites

Analysis of Blind Microvias Forming Process in Multilayer Printed Circuit Boards

CALIBRATION OF A ROBUST 2 DOF PATH MONITORING TOOL FOR INDUSTRIAL ROBOTS AND MACHINE TOOLS BASED ON PARALLEL KINEMATICS

Making Multiple Code Reading Easy. Webinar

Application Report. Propeller Blade Inspection Station

Mini InfraRed Thermometer with Laser Pointer

Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge

On an equal level: CT measurements reach the accuracy of conventional tactile metrology

Prospects of Laser Polishing for Small and Complexly Shaped Parts

Application Example: Automotive Testing: Optical 3D Metrology improves Safety and Comfort

How To Use Bodescan For 3D Imaging Of The Human Body

SafetyScan Lens. User Manual

Shape Measurement of a Sewer Pipe. Using a Mobile Robot with Computer Vision

Automatisierte, hochpräzise Optikmontage Lösungen für die Industrie

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

Transcription:

Executive Summary PCB Component Placement Inspection Optimet s ConoProbe Mark10 HD with a 50 mm focal length lens was used to inspect PCB component placement. The PCB board inspected contained both individual electronic components as well as microelectronic devices and components such as FPGAs, D/A converters, etc. The main goal of inspection relates to the height of the chip legs relative to the board surface. Optimet s collinearity feature, in contrast to triangulation technologies, allows measurements with high lateral resolution between the gaps of the Legs. The chip features measured with repeatability better than 1 um were: Chip height above board surface Legs height above board surface Legs gap separation distance All features measured at 9 khz measurement rate. 1. Optimet s Advantages over Other Technologies: 1. Collinearity permits a measurement between the legs in both axes. Sensors using triangulation techniques cannot measure between legs in both axes without rotating the board. 2. Both axis scans have similar performances due to circular sensor laser spot shape. 3. High lateral resolution 4. High sampling rate with no need for averaging 2. Application Description Non contact inspection of PCB component placement measurements using a two axis scanner. The sensor (fig. 1) can also be integrated in vision inspection system. Figure 1-Conoprobe Sensor 2.1 Chip Characteristics / Features The measured features of the chip marked in fig. 2 are: Chip leg heights above board surface Board surface height variation between legs Gap between chip legs Nominal dimensions and height of chip Figure 2 The measured chip

2.2 Method Using Optimet s ConoProbe Mark10 HD with a 50 mm focal length lens (fig. 3), the interface between the chip and PCB can be measured and inspected. Measurements Setup Sensor Type: ConoProbe Mark 10 HD Lens focal length: 50 mm lens Sample rate: 3 khz (up to 9 khz). Laser power level: 45 (~0.6 mw). Step along the line (X): 2 µm Step between lines (): 2 µm Room temp: 23 24 C Probe spec Working range: Standoff: Precision: Spot size: 2 mm 40 mm 2.5 um 15 um Z X Figure 3 Optimet s ConoProbe Mark10 HD 3. Results and Observations Leg Height Measurements leg height [mm] Reference point 0.0455 0.047 0.0482 0.0453 0.0473 0.0471 0.0476 0.0472 average 0.0469 std 0.00093 Under 1uM standard deviation in leg height Figure 4 MK 10 HD with a 50 mm lens Table 1 Chip leg heights

Explanation of fig. 5 and table 1: In order to detect whether the chip was properly placed on the PCB, the leg heights above the board were measured. The point scan resulted in a standard deviation of under 1µm. This indicates that, the legs were properly placed. Short Circuit Testing Valley height [mm] Reference point 0 0.0012 0.0027 0.0035 0.0007 0.0084 0.0019 average 0.002629 std 0.002599 Figure 5 MK 10 HD with 50 Table 2 Chip valley heights Explanation of fig. 5 and table 2: In order to detect board damages or short circuits between the legs at the board surface, the surfaces heights between the legs were measured. Due to the collinearity and lateral resolution of the sensor, measurements could be made all the way down to the board base surface and between the legs.

Chip Nominal Dimensions Gap size = 0.35 mm Average distance between legs = 0.659 mm Here it can be seen that in addition to the placement inspection we can also measure the chip nominal dimensions after the placement and check that the chip was not damaged during the placement. In this case we can compare our results to the data provided in the chip datasheet. Nominal value Figure 7 MK 10 HD with a 50 mm lens Single Leg Height Scan of a single leg. The scan was performed along the leg, in order to indicate where on each leg the previous measurement was taken. X 4.69 um

4. Data Parameter Value Reflective/Diffusive/Transparent/Translucent Diffusive Working Range (mm) 2 Precision (µm) 2.5 Stand Off (mm) 40 Max. Data Rate (KHz) 9 Lateral Resolution Z Resolution Application Category