Polyiso Insulation. Tapered Polyiso Insulation

Similar documents
Polyiso Insulation. Insulation Pieces Square Feet Square Feet Square Feet Thickness Per Bundle Per Bundle Per Bundle Per Truckload

Polyiso Insulation. Tapered Polyiso Insulation

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE

Proven roofing SyStemS

BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof.

CHAPTER 7: Building Systems ROOFING SYSTEMS

Prices Effective April 1, 2016

Achieving Maximum Roof Performance at the Lowest Installed Cost With Invinsa Roof Board

GENERAL ROUTING INSTRUCTIONS

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

PRODUCT CONTROL SECTION

COMMERCIAL BUILDING APPLICATIONS

Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE

FOR ALL DOMESTIC MOOG LOCATIONS

TECH BULLETIN. Roofing No. Impact of Temperature on Polyiso R-value. Subject: Impact of Temperature on the R-value for Polyisocyanurate Insulation

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

HOW TO INSULATE A CRAWLSPACE

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

Claims Management Policy

The minimum reinforcement for the stem wall is the placement of:

PORTER INSULATION PRODUCTS

Acceptance Codes APPENDIX - A. Acceptance Criteria

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

pvc well casing & drop pipe

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

Trailer Selector Guide for Freight Shipping

Roof Insulation Building. Energy. Environment friendly e-library

HexWeb CR III Corrosion Resistant Specification Grade Aluminum Honeycomb

SECTION REMOVAL AND SALVAGE OF CONSTUCTION MATERIAL RECLAMATION OF RESILIENT FLOORING

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

A World Class Manufacturer of Induction Bends

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

P.O. Box Baltimore, MD

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

Overview - Party City (includes Party City, Party America, and The Paper Factory)

CARRIER ROUTING GUIDE

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

Laboratory Report P Simulated Wind Uplift Testing of Adhered Single-Ply Roofing Systems in accordance with FM Standard 4470, Appendix C

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

ATLAS Roofing Products

Phosphoric Acid Anodized Aluminum Honeycomb

STATE OF UTAH "BEST VALUE" COOPERATIVE CONTRACT CONTRACT NUMBER: PD136 April 07, 2015

Customer Support. Values and People Define Us Customers Inspire Us. Where Tradition & Innovation Converge

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

UL Online Certifications Directory

EPDM. Roofing systems

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

GreenGuard Housewrap Installation Guide

Cost Comparisons for Common Commercial Wall Systems

UBC Product Quality Specifications

Aquaculture Tanks Manufacturer of Fiberglass Aquaculture Tanks Water Cisterns Aquariums Fish Ponds Custom Fabrications

3 rd Party Billing Instructions Page 1

American Fast Freight

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Insulation R-Value Comparisons

TARRANT COUNTY DETAIL STANDARDS

Reflectex TM Reflective Concrete Interlayer Geotextile INSTALLATION GUIDELINES

COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Colorado State University. Durrell Center Roof Repair

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

Firestone SBS Modified Bitumen Roofing System Design and Application Guide

ISO Types 1-6: Construction Code Descriptions

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

EXPANDED POLYSTYRENE FOR. ResidentialBuilding Applications

Chapter 3 Pre-Installation, Foundations and Piers

R-Value and Densities Chart

How To Design A Post Tensioned Deck For A Building

Tapered Polyiso Roof Insulation & Gemini Products

Wisconsin Expo, Inc.

AZEK Rail Install Guide

Quality Building Products for over 50 Years

Additions and Alterations

ANVIL STEEL PIPE NIPPLES (WEST COAST) - WELDED Price Sheet Pn-6.08W (WC) Effective: June 2, 2008 Cancels Price Sheet PN-4.08W (WC) of April 14, 2008

The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma

MASTER FUEL RELATED INCREASE

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS

SEM Model 23/5 GREEN VALUE KIT Medium / Heavy Duty Disintegrator & Briquettor System

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

45 URAI DSL Roots. Quick Specs. Also Available in: Part Number T

WHAT IS LTL FREIGHT? A Guidebook for Beginners

Transportation Requirements

Georgia State University. Urban Life Building Roof Replacement

Mode of Shipment Carrier Payee/Terms Threshold Rules

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature

Introduction...COMB-2 Design Considerations and Examples...COMB-3

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

Transcription:

All Firestone Polyiso insulations have a polyisocyanurate foam core. The standard compressive strength is 20 psi, but 25 psi is also available, upon request. Different facers are used to make specific products, as described below: Product Name ISO 95+ HailGard ISO 95+ Woodfiber Composite Polyiso Insulation Top Side Insulation Pieces Square Feet Square Feet Square Feet Per Per Per Per 4x8 4x4 1.00 48 1,536 768 36,864 1.25 38 1,216 608 29,184 1.50 32 1,024 512 24,576 1.75 27 864 432 20,376 2.00 24 768 384 18,432 2.30 20 640 320 15,360 2.50 19 608 304 14,592 2.80 17 544 272 13,056 3.00 16 512 256 12,288 3.25 14 448 224 10,752 3.50 13 416 208 9,984 3.75 12 384 192 9,216 4.00 12 384 192 9,216 Tapered Polyiso Insulation Bottom Side Black Glass Reinforced Mat Black Glass Reinforced Mat 7/16" Oriented Strand Board Black Glass Reinforced Mat 1/2" Wood Fiber Black Glass Reinforced Mat Panel Pieces Square Feet Slope Min - Max Code Per Per 4x4 AA 64 1,024 1/8" Slope 0.5"-1.0" A 38 608 1/8" Slope 1.0"-1.5" B 26 416 1/8" Slope 1.5"-2.0" C 20 320 1/8" Slope 2.0"-2.5" G 32 512 1/4" Slope 1.0"-2.0" H 18 288 1/4" Slope 2.0"-3.0" X 48 768 1/4" Slope 0.5"-1.5" Y 24 384 1/4" Slope 1.5"-2.5" Q 32 512 1/2" Slope 0.5"-2.5" Note: The most commonly used tapered panels are listed here. Firestone Tapered ISO 95+ is available in 1/2", 1/4", 1/8" 1/16" and 3/16" slopes per foot and in 4'x 8' panels. For more information, tapered system quotes or design assistance, please contact your Firestone sales representative or the Firestone Tapered Department. Firestone Plant Locations: Connecticut, Florida, Kentucky, Pennsylvania, Texas, Wisconsin, and Utah. 1 of 1

ISOGARD TM HD Item Code Pieces s Per Square Feet Per Per 1/2" - 4' x 4' W8H-3GG-050I 46 96 70,656 1/2" - 4' x 8' W8H-3GG-050H 46 48 70,656 Note: Stopover fee of $100.00 charged for a second delivery destination located within 50 miles of the first delivery point. 2 of 2

Product Name RESISTA RESISTA POLYISO INSULATION Resista is a closed cell polyisocyanurate foam core, bonded chemically to a heavy duty, dimensionally stable, inorganic glass facer. The standard compressive strength is 20 psi. Top Side Inorganic Double Coated Glass Mat Insulation Pieces Square Feet Square Feet Square Feet Per Per Per Per 4x8 4x4 1.00* 48 1,536 768 36,864 1.25 38 1,216 608 29,184 1.50* 32 1,024 512 24,576 1.75 27 864 432 20,376 2.00* 24 768 384 18,432 2.30 20 640 320 15,360 2.50* 19 608 304 14,592 2.80 17 544 272 13,056 3.00* 16 512 256 12,288 3.25 14 448 224 10,752 3.50 13 416 208 9,984 3.75 12 384 192 9,216 4.00 12 384 192 9,216 *Note: 1.0, 1.5, 2.0, 2.5, and 3.0 do not have a minimum bundle requirement. For all other thicknesses a minimum 20 bundle order is required. RESISTA Tapered Polyiso Insulation Bottom Side Inorganic Double Coated Glass Mat Panel Pieces Square Feet Slope Min - Max Code Per Per 4x4 AA* 64 1,024 1/8" Slope 0.5"-1.0" A* 38 608 1/8" Slope 1.0"-1.5" B 26 416 1/8" Slope 1.5"-2.0" C 20 320 1/8" Slope 2.0"-2.5" G 32 512 1/4" Slope 1.0"-2.0" H 18 288 1/4" Slope 2.0"-3.0" X* 48 768 1/4" Slope 0.5"-1.5" Y* 24 384 1/4" Slope 1.5"-2.5" Q* 32 512 1/2" Slope 0.5"-2.5" *Note: The Tapered AA, A, X, Y, and Q panels do not have a minimum bundle requirement. For all other thicknesses a minimum 20 bundle order is required. Note: For more information, tapered system quotes or design assistance, please contact your Firestone sales representative or the Firestone Tapered Department. Firestone Plant Locations: Kentucky, Pennsylvania, and Utah. Lead Time: A 7-10 lead time can be expected 3 of 3

DensDeck Item Code W56RAC Pieces Per s Per 1/4" - 4' x 8' 8625 42 28-29 37,632-38,976 1/2" - 4' x 8' 8650 30 24-25 23,040-24,000 5/8" - 4' x 8' 8662 30 18-19 17,280-18,240 DensDeck Prime 1/4" - 4' x 4' 8724 60 40 38,400 1/4" - 4' x 8' 8725 42 28-29 37,632-38,976 1/2" - 4' x 4' 8754 50 28 22,400 1/2" - 4' x 8' 8750 30 24-25 23,040-24,000 5/8" - 4' x 4' 8764 40 28 17,920 5/8" - 4' x 8' 8762 30 18-19 17,280-18,240 Item Code W56RAC Item Code W56RAC Pieces Per DensDeck DuraGuard Pieces Per s Per s Per 1/4" - 4' x 4' 8824 60 40 38,400 1/4" - 4' x 8' 8825 42 28-29 37,632-38,976 1/2" - 4' x 4' 8854 50 28 22,400 1/2" - 4' x 8' 8850 30 24-25 23,040-24,000 5/8" - 4' x 4' 8864 40 28 17,920 5/8" - 4' x 8' 8862 30 18-19 17,280-18,240 *1/4" Dens-Deck is available in select ISO plants and may be combined with ISO 95+ orders. Note: Stopover fee of $100.00 charged for a second delivery destination located within 50 miles of the first delivery point. 4 of 4

SECUROCK Gypsum Fib Item Code W56RAC 1/4" - 4' x 4' 8770 1/4" - 4' x 8' 8766 3/8" - 4' x 4' 8771 3/8" - 4' x 8' 8767 1/2" - 4' x 4' 8772 1/2" - 4' x 8' 8768 5/8" - 4' x 4' 8733 5/8" - 4' x 8' 8769 Item Code W56RAC 1/4" - 4' x 8' 8774 1/2" - 4' x 8' 8775 5/8" - 4' x 8' 8776 SECUROCK Glass M *Quanitites can vary according to shipping location and should be verified at the time of order placement *Securock is a registered of USG

ROCK Gypsum Fiber Roof Boards Pieces Per 100 2,540 50 2570 80 2565 40 2595 60 2445 30 2475 48 2445 24 2,475 ROCK Glass Mat Roof Boards Weight Per (lbs) Pieces Per Weight Per 42 1,688 30 1995 30 2667 time of order placement

s Per * 18 28,800 18 28,800 18 23,040 18 23,040 19 18,240 19 18,240 19 14,600 19 14,590 s Per * 28 37,632 24 23,040 18 17,280

Firestone Wood Fiber Roof Insulation Product Item Code W56358 Size Pieces Per Square Feet Per Weight Per s Per Truck 1/2" FiberTop "E" (Jarret, VA) 8501 4' x 4' 95 1,520 973 44 66,880 8502 4' x 8' 95 3,040 1,946 22 66,880 1" FiberTop "E" (Jarret, VA) 8504 4' x 4' 48 768 907 44 33,792 8505 4' x 8' 48 1,536 1,813 22 33,792 1/2" FiberTop "B" (Intl' Falls, MN) 8501 4' x 4' 90 1,440 1,140 44 63,360 8502 4' x 8' 90 2,880 2,300 22 63,360 1" FiberTop "B" (Intl' Falls, MN) 8504 4' x 4' 45 720 1,120 44 45,760 8505 4' x 8' 45 1,440 2,080 22 45,760 Availability: Firestone FiberTop is manufactured in a number of strategically located facilities in order to provide prompt and efficient delivery throughout the United States. Poly Bagging: All truckloads of FiberTop are shipped without poly bagging. Poly bags are available upon request for an additional charge. Wood Fiber Freight Terms - Freight allowed on truckload shipments of ½" and 1 wood fiber roof insulation for full truckloads only. - For an additional charge, 1/2" 4' x 8' wood fiber roof insulation is inventoried in some Firestone insulation plants and may be combined with ISO 95+ for prepaid shipments. - 1 wood fiber roof insulation is not inventoried at any Firestone location and is only shipped in full truckload quantities. 8 of 8