FAN COIL UNIT SOFTWARE User Manual



Similar documents
Innovent LASER Packaged Fresh Air Conditioning Units

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

MAC-120HE-01 Air-Cooled Chiller

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

Calculating System Flow Requirements

State Grant Information Technology Application

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Air Conditioners Technical Data

SWIMMING POOL HEAT PUMP Owners Manual

USER S MANUAL HSC-24A

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

How To Create A Hyperlink In Publisher On Pc Or Macbookpress.Com (Windows) On Pc/Apple) On A Pc Or Apple Powerbook (Windows 7) On Macbook Pressbook (Apple) Or Macintosh (Windows 8

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

The New Data Center Cooling Paradigm The Tiered Approach

Rating Water-Source Heat Pumps Using ARI Standard 320 and ISO Standard

ELECTRIC CENTRAL HEATING FLOW BOILER

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

COMMISSIONING OF HVAC SYSTEMS

Sound pr. (db(a)) Phone: Pressure hpa Fax: Capacity kw

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

CRAC Precision climate control units for data centres

85 F 80 F 50% 75 F 70 F 73.0/ F 10% Figure 1

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

york air-conditioning products Residential & VRF News 2015

STULZ Water-Side Economizer Solutions

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Portable Air Conditioner

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Chilled Water Precision Air Conditioner For Critical Application

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Characteristics of Evaporators

Appendix - Controllers 179

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

Envisioneer Technical Note

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

THE PSYCHROMETRIC CHART: Theory and Application. Perry Peralta NC State University

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

Technical data. Danfoss DHP-A

CE6500 Energy Recovery Ventilator

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

JAVS Scheduled Publishing. Installation/Configuration... 4 Manual Operation... 6 Automating Scheduled Publishing... 7 Windows XP... 7 Windows 7...

Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE

QZSR Fan Coil. Key features. Specifications. Product code example Cassette Unit QZSR, QZSR

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Chapter 3.4: HVAC & Refrigeration System

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

CRITICAL COOLING FOR DATA CENTERS

Help. Help Software Tutorial. Building a load sizing project with an ME Series Humidifier


How and Why Mission- Critical Cooling Systems Differ From Common Air Conditioners

Cooling Audit for Identifying Potential Cooling Problems in Data Centers

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Installation Manual CLIFC Fan & Coil Variable Speed

Performance Rating of Room Fan- Coils

CREATING AN IMAGE FROM AUTOCAD CADD NOTE 16. MENU: AutoCAD, File, Plot COMMAND: plot ICON:

What are the Carrier ChillerVu Energy Dashboards?

Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida

Pioneer in sustainability

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Google Apps for Sharing Folders and Collecting Assignments

Element D Services Heating, Ventilating, and Air Conditioning

STANDARD COMMISSIONING PROCEDURE FOR PACKAGED HEAT PUMP (AIR-TO-AIR) & AIR CONDITIONING UNITS

Element D Services Heating, Ventilating, and Air Conditioning

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

- White Paper - Data Centre Cooling. Best Practice

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Why Do I Need Precision Air Conditioning?

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

Air Conditioners. Technical Data. Wall Mounted Unit. RX-JV/GV

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Best Practices in HVAC Design/Retrofit

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Work with the MiniBase App

SA-9600 Surface Area Software Manual

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

Nirvana. Cycling Refrigerated Dryers

Practical Exercise on PC. Create Climate files Daily time step. Solution of the exercise

HHC Compensation Module Training Document

Moisture Control. It s The Dew Point. Stupid! Its not the humidity.

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

By Tom Brooke PE, CEM

type UTA Technical information manual

Lab: Data Backup and Recovery in Windows XP

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Transcription:

User Manual Thanks for using Tiba fan coil units' selection software. To start the selection process to software selection there are some steps we need to follow: Front page: 1. Only selection 2. Performance tabled 3. Offers management 4. Offer path 5. Language 6. Unit measure system (Select request measurement customer technical(si) or custom Imperial ) 7. Currency management 1

1. Only selection The only selection button use in case of you need only one selection not many selections for a complete project.( more than one selection will be explained later in Offers management). 2

1. Performance tabled To generate a complete table for units' performance at different air flow rates. a- Input data Select model Select fan speed Select Standard air flow or fan with external static pressure. Determine no. Of Rows Add request on coil dry & wet bulb temperature Add water in/out temp And click on the "generate: button we get this 3

We select the cooling folder and select the file which contains selected model and click on "open" Please wait few minutes, after finished generate 4

We go to link C:\Program Files\Fancoils6Tiba\Cliente\Excel Catalogue\Cooling We get the results of performances table. 5

1. Offers management The Page Includes New offer (to add new project) Open offer Save offer Delete offer Customers (add the customers details) Exit Offer Regen. (to work regeneration) Export PDF (to get software output is PDF format) Change logo Add (to get new unit) Delete ( deleted unit) Modify (to modify the unit) Currency management 6

To start the unit selection: 1- Just click on the "Add button, we get to selection window a- Input data o Request capacity (kw) o Then selected desired & accepted range % 10-50 %. o Type of fluid User can select water, ethylene or propylene glycol as per desired concentration. o Air flow (standard air flow OR fan with E.S.P (pa)) o Type of filter (aluminium or synthetic) o Sound (sound pressure and sound power...) o Models (example CRA.CRM, CRL...) o No. of rows (3 or 4 rows) o Fan speed (High, Medium or Low) o Plant(2pipe or 4 pipe) o Fin type (corrugated, smooth, and louvered) o Cooling data (inlet air condition DB/R.H AND) o User can make selection or calculation depending water in/out temp. Or water in / flow 7

rate. o o Heating data (inlet air condition DB/R.H AND fluid condition in/out) maximum range of temperature 29 c Auxiliary coil (in case 4 pipe system) b- Output data o Selected air flow o Static Pressure (Pa) o Total capacity (kw) o Sensible capacity (kw) o Water Entering /Leaving temp &water flow &water pressure drop o Air out DB C /R.H % o Heating Water Entering /Leaving temp &water flow &water pressure drop o NOISE o PRICE ($) **For Example Required AIR FLOW 600 CFM & E.S.P 30 PA, IAT 24/50%, WATER TEMP 7/12 C, Heating condition INLET AIR TEMP 20 C INLET WATER TEMP 70 C AND RANG OF TEMP 25 C 8

Selection 1- Select model CRA 2- Entering air flow m3/h 1020 3- Entering E.S.P (pa) 30 4- Tolerance 50% 5- Determined no. Of rows FAN COIL UNIT 6- Entering inlet air temperature DB C & relative humidity (not wet bulb) 7- Entering Inlet Fluid Temperature & range of temperature 8- Heating Entering inlet air temperature DB C& Fluid Temperature & range of temperature And click on the "compute" button and select the 3 speeds of the same unit that one speed of them has already verified the required air flow and cooling capacity 9

Then click on the "configure accessories" button You will get Parameters No. of rows &no. of circuits& fin pitch, all can be changed manually to achieve the required capacity. Accessories Selection by project requirements Multiplier Multiplier unit/ multiplier accessories to generate the unit price 10

Then click the "PRINT" button You will get 11

Then click on the "Print out Extra Data" button to insert unit identification And click on the "ok" button In the page click on the button "save" 12

And click on the "ok" button And click on the "Exit" button PRINT OUTPUT Click on the "EXPORT PDF" button 13

1. Offer path The path of save offer on computer. 2. Language (Choose the language you want) 14

3. Currency management (the basic currency is $) 4. Unit measure system (Select request measurement customer technical(si) or custom Imperial ) Thank you 15