CO Low CO High O 2 NO NO 2 NOx SO 2 H 2 S CxHy CO 2 LANCOM III



Similar documents
LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

The testo 340 What makes it The Ultimate Combustion Tuner?

Highly efficient flue gas analyzer

PortaSens ll G AS DETECTOR

Software Features of Auto Gas Gas Analyzer Features HC, CO, CO2, Lambda, Air Fuel, NOx. Has optional RPM and Oil Temp.

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Online Infrared Flue Gas Analyzer Gasboard 3000

The Ambient Air Monitoring System

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Car and commercial cial air conditioning service solutions

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

G100 Range. Operating Manual

LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers

Medical Air Systems: Scroll

Thermal Mass Flow Meters

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

AMBIENT AIR QUALITY MONITORING SYSTEM. Air Quality Monitoring... Easier. Faster. Better.

USB-500 Series Low-Cost Data Loggers and Accessories

How To Use A Ds340 (Dsp)

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

5000V Graphical Megohmmeter Model 5070

Kane Automotive. Gas Analyser Manual for models; Auto 2-2; 4-2 & 5-2; Auto 4-1 & 5-1

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

USB-500 Series Stand-Alone, Low-Cost Data Loggers

USB-500/600 Series Low-Cost Data Loggers and Accessories

Hand-held thermometer Model CTH7000

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Lockout Specification BW Clip Maintenance-free single gas detector

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

RECON-4 Portable Multi-gas Detector Software Manual

INDEX GENERAL

KANE9206. Quintox Flue Gas Analyser. Stock No: November Kane International Ltd

Galaxy Gas Analyzer. New Brunswick. Operating manual

Analytical Instruments Smart Analyzer 90 Type SMA

Diagnostics for Mobile Homes: HVAC

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Emission Testers. for Diesel, Gasoline and Gas Engines. Model: MET 6.3 MET 6.1 MET 6.2 Export MDO2 LON MGT5 DITEST SPEED 2000 RPM VC2

Galvanic Parts Per Million Dissolved Oxygen Systems

4-Channel Thermometer / Datalogger

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Mass Flow Meter Product Guide

Element D Services Plumbing

Gas and flame detection Stack gas and dust analysis

Wahl C50 Calibrator FEATURES

ORGANIC SAMPLE PREPARATION

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Rackmount Intelligent Pressure Scanners

The L&J Engineering Model MCG 1500SFI Servo Gauge

Air Pollution Control Division. Technical Services Program

abc Control Processors New Infrared Linescanner Control Signal Processors instruments international

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ETV Joint Verification Statement

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

KNC Model 3666 Automatic Pressure Calibration System

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

InfplusWin OPERATING MANUAL

Blast Vibration and Overpressure Monitor

Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

Gas sensors for greenhouse measurements

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Product Information Sheet UH36 Hi Pot Tester

Dual Laser InfraRed (IR) Thermometer

DUST EMISSION MONITORING SYSTEM

COMBUSTION. By: Michael Biarnes. In collaboration with: Bill Freed and Jason Esteves. E Instruments International LLC -

Energy Efficient Operations and Maintenance Strategies for Boilers

Technical Specification. Generating Set with Waukesha engine burning natural gas

Electric Flow Boiler

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Application Note 12: TrendView Recorders Continuous Emissions Monitoring

DISSOLVED OXYGEN METER Model : DO-5509

O C M III. Open Channel Flow Monitor

Thermal Mass Flow Meter (Series MST)

Rule EMISSIONS OF OXIDES OF NITROGEN FROM LARGE WATER HEATERS AND SMALL BOILERS

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

Multifunction HVAC and IAQ Meter

Advanced Solutions for Gas Monitoring

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

Hygro-Thermometer + InfraRed Thermometer Model RH101

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Digital Air Pressure Gauge Users Manual

How To Use An Irius Pid Detector

COMBIMASS. Technical Data COMBIMASS eco-bio +

HP ProDisplay P19A LED Backlit Monitor. User Guide

STERILIZERS, LABORATORY DRYING OVENS

ORBISPHERE M1100: CUSTOMER SUCCESS STORY - CARLSBERG

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Transcription:

portable flue gas monitoring CO Low CO High NO N NOx S H 2 S CxHy C LANCOM III Combustion & Environmental Monitoring

LANCOM III the world s most versatile portable flue gas analyzer The new Lancom III is now firmly established at the forefront of portable flue gas analyzer technology. In excess of two thousand Lancom analyzers are in use today, in a wide range of applications - all subjected to very different measurement conditions. Features & Benefits Monitoring of up 17 measurement parameters - one instrument to meet all requirements Up to 9 simultaneous gas measurements - user selectable Weighs only 6kg (13lbs) - easily carried around plant Robust, industrial design - for daily use in the harshest plant environments Integral printer - instant record of measurement readings Wake and Sleep, semi-continuous operation mode - for periodic unattended operation Range of user selectable options - ideally matched to application requirements Data acquisition & analysis software - capture, manipulate, and report data on your PC Simple field upgrade - add features and options as and when required Meets US EPA CTM 034 reference method - report generation to recognized standards CO Low CO High CO Low H 2 comp NO S NO x N C H 2 SC x H y

Measurement Specifications Sensor Standard Range Max. Range # Accuracy Resolution Oxygen, 0 to 25.0 % Vol. 0 to 30.0 % Vol. ±1 % ±0.1 % Vol. Carbon Monoxide, CO (low) 0 to 2 000 ppm 0 to 10 000 ppm ±2 %* ±1 ppm CO (H 2 ) compensated 0 to 2 000 ppm 0 to 4 000 ppm ±2 %* ±1 ppm Carbon Monoxide, CO (high) 0 to 4 % 0 to 10 % ±2 %* ±1 ppm Sulphur Dioxide, S 0 to 2 000 ppm 0 to 5 000 ppm ±2 %* ±1 ppm Nitric Oxide, NO 0 to 1 000 ppm 0 to 5 000 ppm ±2 %* ±1 ppm Nitrogen Dioxide, N 0 to 100 ppm 0 to 1000 ppm ±2 %* ±1 ppm Hydrogen Sulphide, H 2 S 0 to 200 ppm 0 to 1 000 ppm ±2 %* ±1 ppm Carbon Dioxide, C ** 0 to 25.0 % Vol. - ±0.5 % Vol ±0.1 % Vol. Hydrocarbons 0 to 5.0 % Vol. (Application dependent) Flue Gas/Ambient Temperature Measured Draft ± 51 cm / 20 " Water Gauge *** Flow (velocity) 1 to 50 m/s Note: Special ranges are available *Calibration per CTM034 or LAND factory procedure **True measurement if sensor fitted (calculated if not) ***Reduced to ± 26 cm / 10 Water Gauge when used with flow probe # Operating at maximum possible range may affect sensor life and accuracy Combustion & Environmental calculations Combustion efficiency Excess Air Oxygen normalization Wet or dry basis Loss CO (where no sensor fitted) 2 Total NOx Automatic conversions - ppm, mg/m 3, lb/mmbtu, ng/j Sensor Types Lancom analyzers use the following sensors in order to measure gas concentration levels. Sensor Type Electrochemical Gas CO Low, CO High, CO Low H 2 compensated,, NO, N, S and H 2 S Infrared C Pellistor/Catalytic C x H y

Convenient catchpot - visible and accessible The side-mounted catchpot is both fully protected and highly visible for rapid checking, removal and emptying. Flue gas & ambient temperature The analyzer takes a direct thermocouple temperature measurement of the flue gas, and has an ambient temperature sensor fitted. These are required for making accurate combustion efficiency calculations. Instant record of measurement data The built-in thermal printer provides an immediate record of the measurement data. All essential information including date and time are printed. LONFIELD POWER STATION BOILER N MAIN SITE -------------------------------- Type of fuel: Light Fuel Oil Dry analysis normalisation: off ----------------------------------- Date: 05.08.02 Time: 10:23 ----------------------------------- T ambient : 25 C T gas : 266 C Tg - Ta : 241 C CO : 2055 ppm 55mg/Nm3 S : 105 ppm N : 43 ppm NO : 272 ppm CxHx : : 1.71 0.65 % % H2S : 742 ppm C NOx : : 14.3 315 % ppm Velocity : 3.0 m/s Flue Temp. : 266 C Flow : 36 cu.m/hr efficiency : 90.2 % loss : 9.8 % excess air : 10.8 % water : 0.0 % norm : 0.0 % -------------------------------- SAMPLE POINT E34B Easy access sensors Each sensor is installed in its own unique position. Replacing a sensor is a simple process and will take only a few minutes. Unclip the side panel for access, swap the sensor and re-calibrate. leading the way

Direct C Measurement capability New micro-sensor technology used in the Lancom III, enables direct measurement of C in flue gas. The combination of this revolutionary C sensor with the measurement capability offered by the flow probe, can give quantitative information on greenhouse gas emission. Backlit LCD user interface The analyzer is fitted with a full function, sealed alpha-numeric backlit LCD and user interface. Straightforward servicing Service is simple via the menu driven software. Self diagnostic checks are run continuously on sensor life and calibration status together with battery life. Clip-in filters - visible and quick to change The chemical and particulate filters are mounted on the side of the instrument. Visible inspection and replacement is straightforward. The rugged case design protects all components from damage. Long life rechargeable battery Rechargeable batteries give up to 8 hours continuous operation. A power supply cable is is supplied for mains power operation and battery recharging. Automatic Sensor Protection Auto Purge of sensors on system shutdown Clears system of corrosive flue gases. CO overrange protection Automatically purges low CO sensor and switches to high range measuring mode, if high levels of CO are encountered. Setup and measure within minutes Simply switch on, an automatic zero calibration is performed by the analyzer. Plug in the sample probe and take real-time gas readings in a matter of minutes. in portable flue gas monitoring

Selecting the analyzer The following features are standard on all instruments: Standard Sample Probe Built-in Thermal Printer Data Logging RS 232 or RS 422 Serial Communications Interface Carrying Case The user selects which gases (between 3 and 9) and options are required. Options & Accessories Draft Measurement - internal stack pressure in hpa or inches water gauge Flow Measurement - flue gas velocity, flow rate and mass emissions rate Smoke Measurement - readings to Bacharach smoke scales Range of Sample Probes - Smoke, Flow, DrySampler* and High Temperature Insight Data Acquisition Software system - simple-to-use Windows reporting software Analogue outputs (12 current loops, independently user configurable) Wake and Sleep facility (Semi-continuous monitoring) - cyclical measurement Dual language display options - English, French, German, Italian, Spanish & Polish *US Patent No. 6782767 Sample Probes Insight - Data Acquisition & Analysis Software Insight is a Windows based data acquisition software program, used for logging measurement data directly from a Lancom portable analyzer. A wide range of sample probes suitable for specific application and measurement requirements are available. Request Information ref. PDS 198 Wake and Sleep Semi-continuous monitoring can be achieved by cyclically sampling and logging gas concentrations over a period of time. This is achieved by alternate wake and sleep phases. User settings include wakeup interval, number of samples between wakeup, sample interval and first wakeup. Data can be analyzed either in real time or during review of stored data. A range of statistical and graphical tools, allow the user to perform measurements, manipulate data, present and print data. Request Information ref. PDS 205

How the analyzer works? 1 6 2 3 4 5 7 11 8 CO H C x H y H 2 S N 10 C CO L NO S 9 Key 1. Sample Gas Inlet 2. Water Catchpot 3. Particulate Filter 4. Pressure Sensor 5. Air Input 6. Sample Pump 7. Expansion Chamber 8. Chemical Filter 9. Purge Pump 10. Exhaust 11. Flow Probe Inlet Integral sample conditioning The gas sample is drawn into the analyser via a sample probe and hose connected to the input connection on the front panel of the analyser. The sample enters the water catchpot where residual water is removed. The sample gas is then passed through a 0.1 micron particulate filter. Filtering out damaging chemicals - prolonging sensor life After removing flow and pressure variations in the sample flow, the gas is routed to the sensor manifolds. To ensure that the CO and C x H y sensors are not poisoned by other gases in the sample, it is fed through a chemical filter prior to being routed to these sensors. This action ensures longer sensor life and higher accuracy. Sensor protection To protect the CO Low sensor from high levels of CO (normally levels >2000ppm), a dedicated purge pump is automatically triggered which blows ambient air to protect the sensor ensuring optimum recovery time and maximum sensor life. View showing measurement sensors Sensor accuracy and longevity To maintain sensor integrity, they are purged with fresh air each time the analyzer is switched on or off. For accuracy they are calibrated on switch on with ambient air.

Further Information U.K. Land Instruments International Stubley Lane, Dronfield S18 1DJ Telephone: +44 (0) 1246 417691 Facsimile: +44 (0) 1246 290274 E-Mail: combustion.info@landinst.com Web: www.landinst.com U.S.A. Land Instruments International 10 Friends Lane Newtown, PA 18940-1804 Telephone: +1 215 504 8000 Toll Free: (in USA) 800 523 8989 Facsimile: +1 215 504 0879 E-Mail: combsales@landinstruments.net Web: www.landinstruments.net Italy Land Instruments Srl Via dell Industria, 2 20037 Paderno Dugnano, Milano Telephone: +39 02 91 08 0020 Facsimile: +39 02 99 04 0418 E-Mail: info@landinst.it Web: www.landinst.it France Land Instruments Sarl 7 Parc des Fontenelles 78870 Bailly Telephone: +33 (0)1 30 80 89 20 Facsimile: +33 (0)1 30 80 89 21 E-Mail: combustion@landinst.fr Web: www.landinst.fr Poland Land Instruments Sp. z o.o. ul. Michalowskiego 5/2 31-126 Krakow Telephone: +48 (0) 12 632 82 62 Facsimile: +48 (0) 12 632 24 74 E-Mail: land@land.com.pl Web: www.land.com.pl Mexico Land Instruments International Av. Horacio 1132 Planta Baja B Col. Polanco, D.F. 11550 Telephone: +52 (0) 55 5281 1165 Facsimile: +52 (0) 55 5281 5364 E-Mail: ventas@landinstruments.net Specifications Display Keypad Indicators Power Supply Ambient Temperature Case Dimensions Weight Standard Accessories Options Full function alphanumeric/graphic LCD with backlight 40 x 8 Matrix Liquid Crystal Tactile membrane (integral with display) functions keys and cursors LED type for ON (Power), Stand-by, Service, Charge, Low Batt., Fault 95-265 V a.c. ±10%, 50-60 Hz, 30 Watts Rechargeable battery 2 x 6 V 4 Amp. hours Typical 8 hr. operation, dependent on options fitted -5 C to 45 C (+23 F to 113 F) Medium density blended polyethylene 453 x 120 x 245 mm (17.8 x 4.7 x 9.6 inches) 6 kg (13 lb) Integral water catchpot and filters Rechargeable lead acid battery (internal) Mains power supply cable Probe handle, Hose and Probe pipe (Lengths listed below under options) Carrying case Thermal printer Data logging Min of 3 to max 9 gases in total, from a selection of 9 gases Probe length options - 0.3, 1.0, 1.5, 2.0, 3.0m/1, 3.3, 5, 6.5, 10ft Alternative probes available - Refer to Data Sheet Reference PDS198 for details Hose length options - 3 m/10 ft or 10 m/33 ft Draught Measurement Flow Measurement, probe length options - 0.7, 1.2, 2.2, 3.0 m/2.3, 3.9, 7.2, 9.8 ft Smoke Measurement, probe length options - 0.3, 0.75, 1.0 m/1, 2.4, 3.2 ft Insight Data Acquisition Software system - Refer to Data Sheet Reference PDS205 for details Analogue outputs (12 current loops, independently configurable) Wake and Sleep facility (Semi-continuous monitoring) Language display options Continuous Product Development may make it necessary to change these details without notice Copyright 2003-2005 Land Instruments International PDS 198 - LANCOM Sample Probes PDS 205 - Insight Data Acquisition Software Land Instruments International has a comprehensive range of Combustion and Environmental Monitoring Instrumentation. www.landinst.com Approval applies to products designed and manufactured in the UK Approval applies in the USA Utilizes ETV Verified Technology (Report Sept. 2000) PDS206/10/05