PowerCommand iwatch 100



Similar documents
PowerCommand iwatch 100 Remote Network Monitoring

PowerCommand 500/550 Remote Monitoring System

PowerCommand Paralleling System Digital MasterControl

Spark-ignited generator set

PowerCommand 3201 digital generator set control

Operator and Installation Manual

TrueAlarm Fire Alarm Systems

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

PowerCommand 1.1 control system

POWER SYSTEM ACCESSORIES

Gas Genset Controls. Genset Control Panel (GCP2) with PCS (PowerCommand Supervisor) Features. Description

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

Wireless Router Setup Manual

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

GE Security. FHSD Monitor / Web Server user manual

NETWORK ENABLED EQUIPMENT MONITOR

GV-Keyboard. User's Manual V2.0

2CSG445012D0201 M2M ETHERNET. ETHERNET interface user manual M2M ABB

IntesisBox KNX LG Air Conditioning

Current Monitoring Kit QUICK START GUIDE

Current Monitoring Kit

KCU Communication. PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules. System requirement: Windows XP or above

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

Energy Communication Unit (ECU)

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

How To Set Up An Andsl Modem Router For Internet Access

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

Telephone- and leased line modem for industrial applications TD-36

User Manual. EtherUSB

IP DSLAM IDL Quick Installation Guide

Tracer Summit Web Server

TrueAlarm Fire Alarm Systems

Digital generator set 1302 control kit

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

SWITCHGEAR. EGP Switchgear

SNMP Web Management. User s Manual For SNMP Web Card/Box

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

Operation. PowerScan Wireless Monitor GM29535 GM Wireless Monitoring System. Models: TP /05a

CRE Monitor Instructions Manual

Modbus Server SAMSUNG Air Conditioners

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

HCS-3600MB2 Conference Main Unit

GTEC transfer switch open transition

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

Uninterruptible Power Supply

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

SITRANS RD500 Configuring the RD500 with PSTN or GSM modems and Windows-based servers and clients for communication Objective:

TD-8610/TD-8610B External ADSL2+ MODEM

Energy Communication Unit (ECU)

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

*Compatible with MPI series grid-tied inverters

Title Page Web/SNMP Management SmartSlot Card

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8

Welcome. Unleash Your Phone

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

PITE 3921 Battery Monitoring System User Manual P V1.0

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Emerson Smart Firewall

PowerShield SNMP Adaptor

VOIP-2CH. Telephone Clocking Adapter. Installation Guide

ABB solar inverters. User s manual ABB Remote monitoring portal

5500 Series, Catalog A5510 Thin Web Server software version 5

Phase Modular Finally the benefits of Modular ups are for all

Temperature Alert. LAN-based Temperature and Humidity Data Logger

IntesisBox Modbus Server SAMSUNG Air Conditioners

HP R12000 and R18000 DirectFlow UPS User Guide

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Olson Electronics Remote Power Monitoring Meter

PE8216/PE8324. Energy Intelligence Solutions

GadgetGatewayIa Configurable LON to IP Router and/or Remote Packet Monitor. ANSI (LonTalk ) and ANSI 852 (IP) standards based.

Powerline Network. RPL-85 User Manual RPL-85. Powerline Ethernet Bridge V All rights reserved. Page 1

NeoGate TA Series Quick Installation Guide

DCS Data and communication server

Product Specifications

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

Connecting to the Internet. LAN Hardware Requirements. Computer Requirements. LAN Configuration Requirements

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

USER GUIDE. For more information visit

dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

WORLD DATA SERVICES. Overview

System Requirements. Package Contents

GV-Data Capture V3 Series User's Manual

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

WD-AMX Water Detection Controllers

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

IP Intercom System. Classroom intercom system for two-way voice communications, help desk support, and security/status monitoring.

Fleet Tracking Capability. FX 500 / FX 250 FleetBroadband Satellite Terminal

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

Dual-Band Wireless Network Extender. Model #: WCB3000N. User Manual. Ver 1.0

Medical Vacuum Systems-PXMI

User s Manual. Management Software for Inverter

Transcription:

PowerCommand iwatch 100 Remote Network Monitoring Description The PowerCommand iwatch 100 system provides convenient means for remotely monitoring generator sets and transfer switches that are interconnected with a Cummins Echelon LonWorks network using an Internet Explorer browser operating on a remote personal computer (PC). The use of a browser rather than dedicated software for remote monitoring eliminates the need for dedicated monitoring software on the monitoring PC, and allows any authorized user on the customer s network to monitor the equipment. Many users can monitor the generator or transfer equipment simultaneously. Access to the monitored site requires set up of the user on the system by an administrator, and use of a password for each user. PowerCommand iwatch 100 users can monitor generator set data including engine data, alternator data, and control system status. They can start or stop the generator set. The user can also monitor connected transfer switches for status (source availability, source data and source connected) as well as load level (when the transfer switch is provided with that feature). Features Easy Access to Generator Set and Transfer Switch Data. Allows access to information over any personal computer without the problems associated with loading software and keeping it up to date. Easy to Use and Understand Graphical Interface. Data is presented to user in a pictorial format that is easy to understand. The graphical displays provide comprehensive data without complexity. Allows Equipment to Page for Service on Alarms. The control system monitors generator sets and transfer switches for alarm conditions, and pages designated technicians based on a configurable priority and schedule. Sends Emails on Alarm Conditions. Allows generator set and transfer switches to send email messages on alarm conditions using an SMTP server. Configurable for User Access Codes. Allows for configurable user names and passwords. Local Data Logging. The PowerCommand iwatch 100 system can be configured for data-logging parameters on the network. Data stored may be accessed via either local or remote PC s. Certifications. UL listed, CE and FCC compliant. Warranty and Service. Backed by the standard PowerCommand Network and Accessory/Parts Warranty and worldwide distributor service network.

System Description The PowerCommand iwatch 100 system is composed of several major groups of equipment and software. The generator sets, transfer switches, and other equipment monitored at a site are interconnected with a Cummins PowerCommand LonWorks network. The network is connected to the PowerCommand iwatch 100 hardware module, which is connected to a TCP/IP Ethernet connection. Optionally, the PowerCommand iwatch 100 hardware module may also be connected to a telephone service line, so that the control may dial out on alarms and send messages to a pager service; or the control may be accessed through the modem for browsing. The standard system consists of one genset and up to 4 transfer switches. PowerCommand iwatch 100 can be customized by CPG for monitoring and control of up to 15 devices. PowerCommand LonWorks Network PowerCommand generator sets and transfer switches can be provided with network interface modules to allow direct monitoring and control by an Echelon LonWorks network. Generator Set AC Data Display The generator set AC data display screen provides information on the current AC voltage, current, frequency, power factor, kw, kva, and kvar output of the generator set monitored. The screen also allows manual starting, stopping, and fault reset of the generator set. Generator Set Engine Data Display Typical Information Displays Main Menu The main menu screen displays the equipment monitored by the PowerCommand iwatch 100 that is connected. It also displays the basic status of genset in the network. The user may click on a component that is displayed to navigate to other system displays. The generator set engine data display provides detailed information on the state of the engine, including speed, oil pressure, coolant temperature, oil temperature, battery voltage, and number of starts. Units of measurement are configurable for either US Standard or Metric values. The screen also allows manual starting, stopping and fault reset of the generator. Remote Genset Annunciator Display

This display emulates operation of genset annunciators, providing status condition on one screen for the major components in the system and full set of NFPA110 Alarms. The screen also allows manual starting, stopping and fault reset of the generator set. Transfer Switch Source Data Display Remote ATS Annunciator Display This screen graphically shows the status of the transfer switch by depiction of the connected source with the normal source and generator source switches shown as either open or closed. The display also provides tabular data covering the individual phase voltage and frequency for each source. The screen also allows manual testing and fault reset of the transfer switch. Transfer Switch Load Data Display This display emulates operation of ATS annunciators, providing status condition on one screen for the major components in the system the NFPA110 Alarms. The screen also allows manual testing and fault reset of the ATS. Alarm History Display The fault information display provides the user with a date and time-stamped remote indication of alarm conditions that have occurred at a site. The data displayed is the device and output on the network that caused the alarm condition. The display is user configurable to specific dates and data points. This screen graphically shows the status of the transfer switch by depiction of the connected source with the normal source and generator source switches shown as either open or closed. The display also provides tabular data covering the individual phase voltage, individual phase load current, power factor, frequency, kw, kva, and kw hours. The screen also allows manual testing and fault reset of the transfer switch.

Alarm Summary Display The Alarm Summary Display allows users to view, acknowledge and clear active alarms. This page can be user defined by date and data point. Monitoring Equipment Requirements The PC monitoring the PowerCommand iwatch 100 system must be provided with Microsoft Internet Explorer version 6.0 or later. Any equipment suitable for use with that application is acceptable. Environment The PowerCommand iwatch 100 hardware equipment is DIN rail mountable. The equipment is designed for operation in ambient temperatures from 0C to +50C. Required power is 100 to 240 VAC, 50/60 Hz. Additional Hardware Needed For Installation and Communication the following additional hardware is required DB9 Female to Female Null Cable Ethernet Cable (RJ-45 Connectors) Power Cord (Dependent on input Voltage) Telephone Cord (Modem Models) Dimensional Data Units in mm and inches ( ) Ordering Info Model Description 0541-1302-01 PowerCommand iwatch 100 with Modem 0541-1302-02 PowerCommand iwatch 100 without Modem

See your distributor for more information Cummins Power Generation 1400 73rd Avenue N.E. Minneapolis, MN 55432 763.574.5000 Fax: 763.574.5298 www.cumminspower.com For Professional Use Only. Must be installed by a qualified service technician. Improper nstallation presents hazards of electrical shock and improper operation, resulting in severe personal injury and/or property damage. Cummins Power Generation is a subsidiary of Cummins Inc. PowerCommand is a registered trademark of Cummins Inc. Echelon and LONWORKS are registered trademarks of Echelon.