EXHIBIT A SCOPE OF WORK



Similar documents
DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Sprinkler and Fire Alarm Systems for the Building Official

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM RECORD OF COMPLETION

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

FIRE ALARM APPLICATION

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

Module 4, Lesson 12 Fire Alarm Systems

FIVE YEAR CERTIFICATION REPORT

Bold items are particular to the City of Euless

Michael Catalano 24 Nassau Avenue, Islip NY Phone (631) Chief Fire Marshal Fax (631)

City of Columbus Department of Building and Zoning Services

PLAN REVIEW GUIDE FOR FIRE ALARM

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

HERNANDO COUNTY FIRE ALARM GUIDELINES

SECTION FIRE ALARM AND DETECTION SYSTEM

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

1.0 General. Inspection, Testing, and Maintenance 1 of 8

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

SECTION FIRE ALARM AND DETECTION SYSTEMS

City of Bettendorf Fire Alarm System Requirements

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

TESTING, INSPECTION, AND MAINTENANCE FREQUENCIES FOR FIRE DETECTION AND ALARM SYSTEMS

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

INSPECTION AND TESTING OF FIRE ALARM SYSTEMS

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS

University of Houston Master Construction Specifications Insert Project Name

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM

University Design Standard. Fire Alarm Systems

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

Fire Alarm Submittal Requirements and Acceptance Testing

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

ENGINEERING SPECIFICATIONS

Program No Section Heading

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)

Maintaining Fire Protection Systems

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

EXETER TOWNSHIP DRY OR WET CHEMICAL FIRE SUPPRESSION SYSTEMS

SECTION FIRE ALARM AND DETECTION SYSTEM

LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado

FIRE DETECTION AND ALARM

Fire Alarm System Plans Review Checklist Property location Date of Review

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

Winnipeg Fire Department Fire Prevention Branch

Columbia University Medical Center. Policies and Procedures for Shutdowns and Modifications to Fire Alarm Systems and Fire Suppression Systems

AETNA FIRE ALARM SERVICE CO., INC.

Finance and Administration Department 907 Billy Mitchell Blvd. P: (210) Fire Alarm Permit Application

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

SECTION FIRE ALARM AND DETECTION SYSTEM

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

BASIC FIRE ALARM TRAINING

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM INSPECTION AND TESTING FORM

Commercial Fire Alarm Standards July 1, 2010 Edition Page 1 of 14

2014 Limited Plan Submittal Checklist

Understanding Fire Alarm Requirements & Inspections. Presented By Bill Conroy Technical Sales For Briscoe Protective Systems Inc

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi CONTROL PANEL

FIRE PROTECTION SYSTEMS ACCEPTANCE INSPECTION AND TESTING PROCEDURE

Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment):

Automatic fire-extinguishing systems for commercial cooking

Fire Safety Plan (Single-Stage Fire Alarm System - Small Establishment)

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

NATIONAL FIRE ALARM AND SIGNALING CODE

NYC SUB-SYSTEMS INSTALLATION & SERVICE REQUIREMENTS OF THE FDNY

1. The objective of this guideline is to provide minimum standards for design and installation of fire alarm systems for the University of Missouri.

SPECIFICATION FOR A TOTAL FLOOD HFC-227ea CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE Cheetah Xi CONTROL PANEL SYSTEM

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

FIRE-FIGHTING DESIGN BRIEF REPORT

REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING APPLICATION PACKET

CHAPTER. Fire Alarm Systems APPROVAL AND ACCEPTANCE. Shop Drawings

COMMISSIONING OF FIRE ALARM SYSTEMS

General Fire Code Requirements Within Commercial Tenant Spaces

Module 5. Fire and Emergency Alarm System Part I- Basics

STATEMENT OF WORK FOR FIRE ALARM SYSTEM TESTING & MAINTENANCE. Project No. SAQMMA-07-C0060 ***OUAGA, BURKINA FASO***

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Alarm and Detection/Suppression

DTW Works Master Specification Version 2006

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

Fire Alarm Systems Permit Packet. City of Greer Fire Department

Fire Alarm System Monitoring - CAN/ULC-S561-03

Transcription:

EXHIBIT A SCOPE OF WORK 1. (Contractor) shall provide fire alarm system maintenance/repair/testing services as described herein to the California Department of Veterans Affairs (hereinafter CDVA, CalVet, or the State, as required by context). Fire alarm system maintenance/repair/testing services shall be provided for the Veterans Home of California - Barstow (hereinafter referred to as the Home), located at 100 East Veterans Parkway, Barstow, CA 92311. 2. The term of this Agreement shall be July 1, 2013 through June 30, 2015. The State reserves the right to extend the term of this Agreement for one (1) additional year under the same terms and conditions. However, the total duration of this Agreement, including the exercise of any option(s) under this clause, shall not exceed two (3) years. 3. Contract shall be effective upon approval of the State. Contractor shall not perform any work required by this contract until written notification is given to Contractor from the Home s contract manager to begin services. 4. The contract managers identified below are responsible for the administration of this Agreement and for responding to contractual inquiries pertaining to the governing provisions of the Agreement during the term of this Agreement. 5. The project representative during the term of this Agreement will be: Veterans Home of California, Barstow Name: Mark Flores Name: Title: Chief Plant Operations Title Address: 100 East Veterans Parkway Address: Barstow, CA 92311 Phone: (760) 252-6207 Phone Fax: (760) 252-6203 Fax: Email: Mark.flores@calvet.ca.gov Email: Contractor Direct all contract inquiries to contract managers. Contract managers may be changed by issuing a 20-day prior written notification and shall not require a formal amendment to this Agreement. The notifying party shall provide complete contact information for the replacement contract manager including his/her name, title, mailing address, telephone number, fax number, and his/her email address. All other changes require a formal written amendment to this agreement. 6. Pre-Action Sprinkler system (Annual) Pre-action sprinkler system service shall follow these codes and standards: NEPA 13A, 70, 72, 75 and the California State Fire Marshall: Title 19, system devices for Service and Inspection are to include: a. Pre-Action Control Panel b. Battery Back-up System c. Alarm Bells d. Alarm Horns e. Alarm/ Strobe-Lights-Beacons f. Manual Discharge Pull Stations g. Smoke Detectors Including Detectors In Duct System h. Graphic Display Panels i. Pre-Action Sprinkler System Service Procedure for Semi-Annual Basis (If applicable) 1) Fire Department Connection I. Check for inlet cap II. Check couplings for damage III. Check gaskets for deterioration

IV. Check clapper valves closure V. Check for visual of exterior obstruction VI. Check identification sign 2) Control Valves I. Check for valve leakage II. Check that valve is secured in open position III. Check bracing for damage 3) Controls I. Check pressure switches II. Check solenoid operation III. Check pneumatic sign IV. Check tamper switch 4) Riser I. Check for leakage II. Check for visible exterior obstruction III. Check bracing for damage 5) Gauges I. Check for damage II. Check that valve is open III. Record system pressure IV. Record supply pressure 6) Sprinklers I. Check for leaking corrosion or painting II. Check for obstruction of flow III. Check for proper installation IV. Check that extra sprinklers and wrench are available V. Check extra sprinklers for the same orifice size and temperature rating as sprinklers in the system 7. Testing Inspections a. Test operation of tamper switches, low pressure switches and post indicator valves. Service procedures shall be on a semi-annual basis. 1) Control Panel and Battery System I. Verify LED operation for power, trouble, and alarm conditions II. Test battery for charge and automatic switchover capability III. Operate test and reset switches for sequence and function IV. Visual inspection of terminations and wiring within the panel 2) Smoke Detectors 3) Visually inspect detectors, service procedures on an annual basis b. Place each detector in alarm using industrially standard and approved methods. c. Perform maintenance as described in semi-annual inspection procedure d. Alarm bills/horns 1) Check individually for full sound power operation e. Manual pull-stations: verify individual operation

f. Auxiliary devices and systems down: air conditioning, heating ventilation systems and power equipment shutdowns will only be performed by special request from the owner g. Pre-Action Riser: 1) Activate solenoid (with detection system) 2) Release air pressure from system using inspectors test 3) Confirm operation of valve to open position h. Perform inspections as required per quarterly cycle 8. Fire Alarm System (Semi-Annual) Frequency of Service and Inspection: Fire Alarm System must be performed by an authorized and certified technician as required and recommended by the authority having jurisdiction. a. System devices for service and inspections (as applicable): 1) Fire alarm control panel 2) Annunciation panel 3) Audible devices 4) Visible devices 5) Manual pull stations 6) Smoke detectors 7) Duct smoke detectors 8) Heat detectors 9) Emergency Voice/Alarm System 10) Fireman Telephones 11) Water flow switches 12) Tamper and post indicator valve switches 13) Magnetic Door Holders 14) Gas detection 15) Air sampling detection 16) Dialer b. Inspection Procedures 1) Check in with immediate facilities supervisor. 2) Notify building central fire alarm station and all occupants in the immediate area that a functional system test is about to be conducted. 3) Perform an inspection of the system for installation integrity 4) Upon completion of test and service: i. Notify central station, facilities supervisor and immediate personnel of completion of service and leave system in full operational condition. ii. Submit to owners representative a fully itemized service report with any recommendations for safety updates and repairs as required. Service procedures performed on an annual basis. c. Control Panel and Battery System 1) Verify LED operation for power, trouble and alarm conditions 2) Test Battery for charge and automatic switchover capability. 3) Operate test and reset switches for sequence and function. 4) Visual inspection of terminations and wiring within the panel. d. Annunciation: Verify for proper operation. e. Alarm Indicating Appliance 1) Audible and visible devices alarm and verification of proper operation and annunciation 2) Speakers (one-way emergency voice/alarm system) put into operation and voice clarification verified. 3) Telephones (two-way) communications systems) verified for voice operation and clarity.

f. Trouble Signals 1) Audible/ visible verification of operation of panel trouble signal. 2) Zone-Disconnect Switches: Verify that each switch performs its intended function and trouble signal is received when a zone is disconnected. 3) Ground Fault Monitoring Circuit: Verify that a ground fault condition occurs at the control panel when any system conductor is grounded. g. Smoke Detectors Smoke detectors sequence each detector in an alarm condition. Each detector will be set in alarm mode using a test gas, external magnet, or appropriate device. h. Pull Stations: Operate per manufacturer s instruction and verify proper operation. i. Training: System operation training can be provided for owner s personnel as needed during system inspection. j. Service Procedures Performed on a Semi-Annual Basis: Perform a Visual Inspection of the following (as applicable). 1) Fire alarm Control Panel 2) Annunciation Panel 3) Audible/visible Devices 4) Manual pull station 5) Smoke detectors 6) Duct smoke detectors 7) Heat detectors 8) Emergency voice/alarm system 9) Fireman telephone 10) Water flow switches: verify proper operation/annunciation to control panel 11) Valve tamper switches: verify proper operation and annunciation to the control panel 9. Special extinguishing system (annual) Preventative maintenance scope of service to be performed is updated from the following codes and standards: NFPA 11, 16, 17, 17A, 69, 70, 72, 96, AND 750. a. Frequency of service and inspection: 1) As recommended, semiannually by authorized and certified technician. 2) On-site personnel should visually inspect on a weekly basis for the following: I. Pressure Gauge on agent storage container II. General condition of both electrical and mechanical system 10. System devices for service and inspection (as applicable). a. Releasing control panel b. Battery back-up systems c. Audible notification devices d. Visual notification devices e. Abort stations f. Manual discharge pull stations g. Smoke, heat, or air sampling detectors h. Maintenance bypass switches i. Agent storage containers, distribution piping and nozzles j. Dry chemical system k. Wet chemical system l. Water mist system

m. Explosion protection system n. Magnetic door holder/release 11. Inspection Procedures: a. Check in with immediate facilities supervisor. b. Notify building central fire alarm station and all occupants in the immediate area that is about to be conducted. c. Perform an inspection of the system for installation integrity, both electric and mechanically. d. Completion of Test and Service 1) Notify central station, facilities supervisor, and immediate personnel of completion of service and leave system in full operational condition. 2) Submit to owner s representative a fully itemized service report with any recommendations for safety updates and repairs as required. 12. Service Procedures Performed on an Annual Basis a. Detection Devices: Sequence each detector in an alarm condition. Each detector will be set in the alarm mode using gas, external magnet or appropriate device. b. Complete system testing as outlined in Section V. 13. Service Procedures Performed on a Semi-Annual Basis a. Control Panel and Battery System 1) Verify LED operations for power, trouble and alarm conditions. 2) Test battery for charge and automatic switchover capability. 3) Operate Test and Rest switches for sequence and function. 4) Visual inspection of terminations and wiring within the panel. b. Detection Devices: Visually inspect detectors. c. Alarm Bells and Discharge Horn/ Strobes: Check individually for proper operation and sound level. d. Manually pull and abort stations: Verify individual operation. e. Auxiliary Devices and System Shut-Downs, Air Conditioning, Heating, Ventilating Systems and Power Equipment Shutdowns will only be performed via SPECIAL REQUEST FROM THE CUSTOMER. f. Check room/ hazard integrity. g. Agent storage containers/ distribution piping nozzles: 1) Check agent quantity and pressure of agent containers. 2) Visually inspect accessible discharge piping and nozzles for integrity and corrosion. h. Training: System operation training can be provided for owner s personnel as needed during the scheduled system inspection. 14. Wet sprinkler system (quarterly) Frequency of Service and Inspection: Perform by an authorized and certified technician as required and recommended by the authority having jurisdiction. a. System devices for service and inspection (as applicable) 1) Water flow switches 2) Tamper and post indicator valve switches. b. Inspection procedures performed on an annual basis 1. Check with immediate facilities supervisor 2. Notify building central fire alarm station and all occupants in the immediate area that a functional system test is about to be conducted 3. Perform an inspection of the system for installation integrity 4. Complete test and service

a) Notify central station, facilities supervisor and immediate personnel of completion of service and leave b) Submit to owner s representative a fully itemized service report with any recommendations for safety updates and repairs as required c. Service procedures performed on an annual basis: perform a function of test of the water flow switch: activate water flow and verify proper annunciation at panel d. Service procedures performed on a quarterly basis (as applicable) perform a function test of the following: 1. Supervisory signal initiating devices/post indicator valve switch operate valve and verify proper annunciation at panel 2. Valve tamper switches: operate valve and verify proper annunciation at panel. Perform a visual inspection of the following (as applicable): e. Sprinkler heads for leaks or defect: check gasket at risers for seal 15. Ansul system & hood cleaning for kitchen (semi-annual) Check and maintain hoods and attendant fire suppression systems for stove as well as the two Ansul control panels (bi-annually/ sprinkler heads). Numbers and types of devices FACP: 1 Annunciators: 3 BPS: 3 Smile detectors: 128 Sombination detectors smoke & heat: 84 Heat detectors: 61 Pull station: 14 Dual Input Module: 101 Control Relay: 14 High current relay: 17 Genesis strobe 15CD Wall: 56 Genesis strobe 30CD Wall: 3 Genesis strobe 30CD Wall: 1 Genesis chime strobe 15CD Ceiling: 19 Genesis chime strobe 30CD Wall: 12 Genesis chime strobe 75CD- WALL: 2 Genesis chime strobe 110 Wall: 1 Weatherproof: 9

ATTACHMENT 3 COST SHEET Submission of this attachment is MANDATORY. TESTING AND MAINTENANCE Pre-Action Sprinkler System Testing Inspection Fire Alarm System Inspection Special Extinguishing System Wet Sprinkler System Ansul System & Hood Cleaning for Kitchen ANNUAL COST Annual Costs (2 Semi-Annuals per year) (2 Semi-Annuals per year) Annual Costs (4 total quarters per year) (2 Semi-Annuals per year) x 2 = _ (Total for one Year) (Total for 2 Years) Note: The estimated costs indicated above will be used for computing the cost as a fair and equitable formula to determine the lowest bidder. HOURLY REPAIR RATES Hourly rate (normal work week, M-F 8 am 5:00 pm) Overtime: M-F for time in excess of eight (8) hours Holiday Emergency after hours & Sunday HOURLY COSTS I hereby certify that this bid is true and accurate for the services to be provided: COMPANY NAME: COMPANY REPRESENTATIVE S NAME (Printed): COMPANY REPRESENTATIVE S SIGNATURE: DATE: