Separation of power and information technology cabling



Similar documents
Screened cable and data cable segregation

Structured Cabling, Earthing & Equipotential Bonding

40 Years of experience in EMC testing

Power Separation Guidelines for SYSTIMAX Installations

Cable Solutions for Servo and Variable Frequency Drives (VFD)

EN and EN : 2008 Integrated standards for telecommunications cabling installation

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Optical Fibers Fiber Optic Cables Indoor/Outdoor

Mitel DECT Base Stations

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Introduction to Data Centre Design

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

EMC OF INSTALLATIONS AND RECOMMENDED CABLE SEPARATIONS

Grounding Demystified

TEST REPORT EN (1997) +A1 (2001)

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Features. Picture. Specifications

HERZ-Thermal Actuators

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Redundancy Module QUINT-DIODE/40

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Drayton Digistat +2RF/+3RF

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

1701/22 FieldMonitor Management Interface Module

Speed sensor MiniCoder GEL 247

An extended EMC study of an electrical powertrain for transportation systems

MOUNTING AND OPERATING INSTRUCTIONS

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

How To Use A Ds340 (Dsp)

Keystone Network Isolator with ESD- and Lightning Protection

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Substation Grounding Study Specification

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Waveguide Access Point WGA631. Product Guide

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER

Separation of common services (above and below ground) INDUSTRY BULLETIN. Background. Separation distances. Proximity of services below ground

Transmitter Actuator 230V wave UP 560. Operation

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Smoke exhaust systems

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Bar code scanners CLV45x / CLV450 / Standard Density

Data Sheet. HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Network Standard Advice No. 1420C 9/6/2011

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

IFC 070 Technical Datasheet

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

R&S SMZ Frequency Multiplier Specifications

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

TECHNICAL DATASHEET Incremental Encoder RI 58-H

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

VDE-approved PVC-Control Cables

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Estimation results on the location error when using cable locator

Comparative study for cables and busbars

Industrial circular connectors

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

Excerpts from the Canadian National Building Code (NBC)

The ITER Earthing Topology: Mesh-Common Bonding Network

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Optocoupler, Phototransistor Output, AC Input

CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

Flexible Control Cables

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Optocoupler, Phototransistor Output, 4 Pin LSOP, Long Creepage Mini-Flat Package

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

OLI. Oil level indicator

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Electronic Pressure Switch EDS 300

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Power transformers. Special transformers Railway

David O Brien, CMP Products (David.OBrien@cmp-products.com)

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

CHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES

EMC Safety switches January 2008

Foreword. Page 2 EN :2000

ACOUSTIC PERFORMANCES OF AN HEMIANECHOIC ROOM FOR ELECTROMAGNETIC COMPATIBILITY TESTS

7 Lighting Technology

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

Shunt lock function 3066

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Transcription:

Technical bulletin Separation of power and information technology cabling Date: 08/2006 This technical bulletin provides you with information on specific technical subjects. It is based on the current rules and regulations and on our current test results. The contents of this document is not legally binding.

General view The requirement for a safe separation of cables for power and information technology cabling within an cable management system has various reasons: the topmost priority is electrical safety. An additional reason in the electromagnetic compatibility (EMC) of the electrical system. Requirements of the standards To maintain the required electrical safety, it is not fully necessary to lay the different current types separately, with the separation in the form of a separation bar. Cables with different voltage levels can be laid in shared compartments (cable ducting systems CDS, cable trunking systems CTS, cable support systems, installation pipes, etc.) without additional separation, if a voltage resistance against the maximum possible voltage is ensured (DIN VDE 0100-520). This safety aspect is usually achieved using appropriate insulation of the lines and cables used. Regarding the electromagnetic compatibility (EMC) of communication cabling, EN 50172 Part 2 specifies some key conditions. Here, two were specified for the minimum spacing of low voltage and data cables for the three areas: primary cabling (service connection), secondary cabling (connection of the individual floors) and tertiary cabling (connections on one floor). Requirements of communication cables Due to the physical properties of communication cables, there is the necessity for spatial separation of cables of different current types. This can be done by maintaining a minimum spacing, either by using multidraw duct systems, or by using retainers within a duct system. @ Rp / 07.08.06 / e_trennung unterschiedlicher Stromarten.doc / Page 2 of 5

The minimum spacing between communication cables and power cables is dependent on many factors, for example: a) the immunity level of the IT cabling of connected units against different electromagnetic influences (transients, lightning pulses, pulse bursts, continuous wave transmissions, etc.); b) the adaptation of the connection units to the earthing concept; c) the local electromagnetic environment (simultaneous occurrence of influences, e.g. harmonics, pulse bursts and continuous wave transmissions); d) the electromagnetic spectrum; e) the distance over which the cables run in parallel (coupling zone); f) the cable type; g) the screening attenuation of the cables; h) the quality of the installation of the connectors on the cable; i) the type and connection of the cable gland system. @ Rp / 07.08.06 / e_trennung unterschiedlicher Stromarten.doc / Page 3 of 5

Minimum distances to be maintained The occurrence of any of the above factors can mean that a minimum spacing or separation is required. In the coupling zone specified under e), it is possible to lay cables with different current types without spacing. However, such areas are only permitted for short ranges and are only valid for the tertiary area (cabling within one floor). As soon as the tertiary cabling has reached a length of >35 m, separation is required. The last 15 m of this section can then be laid without separation or a retainer. In primary and secondary areas, the distance between power cables and IT cables is required according to the following table: Type of installation Unscreened power cables and unscreened IT cables Without retainer or nonmetallic retainer 1) Distance A Aluminium retainer Steel retainer 200 mm 100 mm 50 mm Unscreened power cables and screened IT cables 2) 50 mm 20 mm 5 mm Screened power cables and unscreened IT cables 30 mm 10 mm 2 mm Screened power cables and screened IT cables 2) 0 mm 0 mm 0 mm 1) It is assumed that, in the case of metallic retainers, the dimensioning of the cable laying system can provide screening attenuation appropriate to the material of the retainer. 2) The screened IT cables must correspond to the standards given in the series EN 50288. Note: This table is currently being revised. As soon as up-to-date data is available, the contents will be corrected. @ Rp / 07.08.06 / e_trennung unterschiedlicher Stromarten.doc / Page 4 of 5

Closing comments The frequently asked question of whether separation of different cable types is actually necessary or is specified in the standards cannot generally be answered with "Yes" or "No". The necessity is dependent on local factors, on the cables to be laid and on the quality of the installations. In general, we recommend the use of separators in our wall trunking systems and cable trunking systems. Besides being tidy, there are also positive impacts on the EMC of networks. An additional advantage of separation is in the common installation practice, in which the power cables and the IT cables are laid by different installation companies. In this case, the guarantee for the provided service also plays a role. There are, therefore, many good reasons for using retainers in duct systems. @ Rp / 07.08.06 / e_trennung unterschiedlicher Stromarten.doc / Page 5 of 5