Water Transmission & Sewer Force Main Renewal 16 through 60



Similar documents
High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

SASTT contact details:

Pipeline Replacement using Relining

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

HDPE. High-Density Polyethylene Pipe Systems. Meeting the challenges of the 21 st century

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

San Antonio, TX July 28, 2011

TRENCHLESS TECHNOLOGY GUIDELINES CLOSE FIT THERMOPLASTIC LINING

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

Pipe Bursting. Case Study at Zeeland, MI Collections Seminar September 6, Presentation Agenda. What is Pipe Bursting? What is Pipe Bursting?

12/8/2014. Brought To You By: This webcast is sponsored by NASSCO with the support of IPBA.

City of Hilshire Village Pine Creek Ln Reconstruction

Session: HDPE Pipe Test Rafael Ortega, Vice President, Lockwood, Andrews & Newnam

LEE S SUMMIT USES PIPE BURSTING TO BROADEN ITS ASSET MANAGEMENT TOOLBOX AND REHABILITATE POTABLE WATER DISTRIBUTION SYSTEM

Installation of Large Diameter Buried Pipes

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

Sustainable trenchless rehabilitation of supply pipelines applying static pipe bursting or close-fit lining

Oil and Gas Pipeline Design, Maintenance and Repair

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

LIFELINE PIPELINE RESTORATION AND SEISMIC MITIGATION

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

Rehabilitation Alternatives. MWEA Collection System Seminar October 1, 2009

Water Main Lining A Sustainable Alternative to Open Cut Replacement

Flowtite Jacking Pipe

SPR PE Steel Reinforced Liner

Sewer Line Rehabilitation

Pipe bursting provides viable alternative for rehab work By Greg Key, U.S. Pipe

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

Repair or Replacement - Band-Aids vs. Surgery

UNDERGROUND INFRASTRUCTURE SPECIALISTS TABLE OF CONTENTS

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems.

Platte River Interceptor Slipline Rehabilitation

Utilizing Trenchless Technology to Achieve Watermain Asset Management Objectives

Force Main Condition Assessment: New Technologies & Case Studies

PRESSURE PIPE REHABILIATION CIPP TECHNOLOGIES

Superior Pipe Restoration Solutions. Proven, state-of-the-art technology that saves money, time and inconvenience. belcopipe.com

Butt Fusion Welding of HDPE Pipes Work Procedure

Austin San Antonio Beaumont

SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD

Introduction to Pressure Pipe Rehabilitation with CIPP

A Revolution for Telecom, Electric, Gas, & Water"

Polyethylene Pressure Pipe

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

Annular Space Grouting of Slipline Products

SECTION IX SLIP LINING PIPELINES

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Sewer systems: Failures and rehabilitation

PRODUCT CATALOGUE. for. SMARTPHONE / WEBSITE / DIGITAL EDITION / BOOK / ipad / GPS

Waste Collection Systems

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

SECTION 603 SANITARY SEWER FORCE MAINS

Greensboro s Pilot Program for Water Pipe Bursting Leads to Expanded City Wide Program

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

Sewer Pipe Lining An Economic Solution for Pipe Rehabilitation By Tawana Albany Nicholas, Virgin Islands Waste Management Authority

WEFTEC.06. Kent Von Aspern,* Collins Orton** *Carollo Engineers 2700 Ygnacio Valley Rd Suite 300 Walnut Creek, CA 94598

REHABILITATION OF THE LONG WHARF SEWER FORCE MAIN USING SLIPLINING METHODOLOGY IN NEWPORT, RHODE ISLAND

Appendix A: Acceptable pipe and fitting materials

Emerging Technologies in Wastewater Collection Systems

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

Rehabilitation or Replacement? That Is The Question

HIGH DENSITY POLYETHYLENE


INNOVATION AND COST EFFECTIVE APPROACH TO POTABLE WATER PIPE REPLACEMENT STRATEGICALLY FOCUSED ON DISTRIBUTION SYSTEM WATER QUALITY IMPROVEMENT By

WEKO-SEAL Internal Joint Sealing WEKO-SEAL. internal pipe-joint sealing

PPI TN-27/2009. Frequently Asked Questions. HDPE Pipe for Water Distribution and Transmission Applications

Meeting the Challenge of Pipeline Emergency Repair

CIPP for Large Diameter Pressure Pipes. Water Research Foundation Large Diameter Pipe Rehabilitation Seminar 20 January 2016 George Bontus, P.Eng.

REHABILITATION OR REPLACEMENT? THAT IS THE QUESTION

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

Structural Lining for Water Mains. Presenters: Stephen Marcino, PE and Micah Blate, EIT (JMT)

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment

THERMOPLASTIC LINERS FOR REHABILITATION OF OIL FLOWLINE AND WATER INJECTION LINES, INTEGRITY AND SERVICE LIFE

Sewer Rehabilitation Design Requirements

Program Design and Engineering Key to Infrastructure Replacement and Cost Containment

SA Pipe Relining is dedicated to finding simple, non intrusive

Innovative Methods to Assess Sewer Pipe Risk and Improve Replacement Planning Decisions

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

Guideline Specification for the Replacement of Mainline Sewer Pipes By Pipe Bursting

SECTION POLYVINYL CHLORIDE (PVC) PIPE

725-R-599 PIPE LINING. (Revised ) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE

Township of Enniskillen. Asset Management Plan

Utilities and existing services

by Leonard Friesenhahn, P.E.

Trenchless Technology for Drainage Structures

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

Transcription:

Water Transmission & Sewer Force Main Renewal 16 through 60 North American Operations 1973 S 91 st Street Milwaukee WI 53227 4700 N Pearl Street Jacksonville FL 32206 office 414.321.2247 fax 414.321.2297 www.swagelining.com

Our History Millions of feet of static pipe bursting & Swagelining experience world wide North America s most diverse and experienced trenchless technology management team Granted sole partnership for Swagelining in North America 2003 Trenchless Project of the Year Nominee 2005 Trenchless Project of the Year Nominee 2008 CSX Rail Performance & Safety Awards 2009 APWA Environmental Project of the Year 2010 UCTA Most Valuable Professional Andy Mayer Lead instructor and advisor to the AWWA, EPA, state regulatory agencies and trenchless equipment manufactures

Our Services Trenchless Design Design Build Feasibility study Cost analysis Evaluation of replacement / refurbishment alternatives Engineering Trenchless Construction Swagelining Slip lining Pipe bursting Pre-chlorinated Pipe bursting Pipe splitting

United Kingdom British Gas Development of Swagelining & Pipe bursting in 1970 s

Swagelining History History Method developed by British Gas (1970 s) and patented for gas distribution Success led to potable water crossover Swagelining over 17,300,000 feet installed in the past 28 years Today Currently used to renew water, force main, gas, oil, mining, slurry, chemical, industrial, salt water and off-shore pipelines world wide

Swagelining Process

Swagelining Engineering Overview Follows path of the existing utility Reduces 3 rd party utility damage Reduces infrastructure congestion Engineering design hours reduced Maintains or possibly increases flow capacity C-factor of 150 for life of HDPE No grouting required due to tight fit of HDPE HDPE Long term design life Corrosion protection Increased operating efficiency Unmatched Fatigue Resistance Resistance to RCP

Swagelining Engineering Overview Install HDPE pipe wall thickness that is Solution to the Problem (DR 11 through DR 51) Fully structural HDPE Interactive HDPE Thin walled HDPE

Swagelining Construction Overview Insertion lengths up to 5,000 feet Pipe sizes of 4 through 60 Oil, Gas & Mining Pipelines most suitable 4 through 16 Water Transmission & Sewer Force Mains most suitable 16 through 60 Negotiates field bends Surgical excavations Environmentally sensitive Undertake projects year round Social costs reduced

Integrated Lining System Polymer Materials Specification Liner System Design Insertion Technology Specialized Connectors

Swagelining Process Preparation of Host Pipe Camera inspection Cleaning

Swagelining Process Preparation of Host Pipe Proving pig sent through host pipe to ensure free bore path

Swagelining Process Butt Fusion Sections of HDPE pipe are butt fused together External bead removed

Swagelining Process Job site aesthetics for Urban areas

Swagelining Process - Shuttle Rods through host pipe

Swagelining Process Attach pipe once rods reach entry pit

Swagelining Process Reducing Die HDPE pipe has an OD slightly larger than the ID of the pipe to be renewed Pipe is pulled through a reduction die which temporarily reduces its diameter

Reducing Die

Swagelining Process Rods recovered at exit pit Rods are removed from the exit pit as pipe is pulled into place For the next pull the exit pit becomes new entry pit

Swagelining Process HDPE enters receiving pit Pulling force removed Natural relaxation of HDPE 90% of reversion occurs in 2 hours Remaining reversion occurs overnight

Swagelining Process Results No gaps - all annular space is eliminated Fully structural pipe Interactive pipe Thin walled liner

Swagelining Process Final Connections

Most Applicable 2 16 pipe bursting 16 60 Swagelining Rapid installation Cost effective Solution to problem Long term design life Rural areas environmentally friendly Urban areas reduced social costs

Swagelining Selected Water Projects Year Application Location Diameter Length 2013 Water Transmission USA 24-27 18,500 feet 2012 Water Transmission UK 40 60,000 feet 2012 Water Injection Norway 10 37,800 feet 2012 Chilled Water Line USA 18-20 6,400 feet 2011/2012 Water Transmission USA 30 5,300 feet 2010 Water Transmission France 27 4,600 feet 2010 Water Transmission Australia 24 7,250 feet 2009 Water Injection Republic of Congo 24 180,400 feet 2008 Water Transmission Germany 54 2,200 feet 2006 Water Injection Norway 16 31,200 feet 2005 Sewer Force Main Germany 32 3,280 feet 2004 Sewer Force Main Singapore 18 3,100 feet 2002 Water Irrigation Abu Dhabi 20 62,300 feet 1999 Sewer Force Main Poland 16 4,600 feet 1996-2001 Water Transmission/Sewer Force Main USA 20, 27, 30, 36 45,700 feet 1992-1993 Water Transmission UK 42 4,850 feet

Swagelining Case Study Amarillo, TX Challenge Phase 1: 2,100 feet of 30 Cast Iron Water Transmission Main installed in 1927 completed 2011 Phase 2: 3,200 feet of 30 Cast iron Water Transmission Main installed in 1927 completed 2012 Leaking lead joints Tight easement, under homes and through busy roads Shut down limited to dry weather Flow capacity needed to be maintained

Swagelining Case Study Solution Several Methods Analyzed with Swagelining selected to maximize flow capacity, limit excavation, follow the existing utility path and speed of installation Liner System Design 32 Outside Diameter DR 32.5 HDPE DR 4710 1,800 feet average pull distances to minimize connections

Swagelining Case Study Impact Small footprint to reduce social and environmental costs 90% less excavation than open cut Rapid installation to complete project within dry weather shut down period Tight fitting HDPE will provide 100 year design life Corrosion Protection barrier Prevent future leaks

Water Transmission & Sewer Force Main Renewal 16 through 60 North American Operations 1973 S 91 st Street Milwaukee WI 53227 4700 N Pearl Street Jacksonville FL 32206 office 414.321.2247 fax 414.321.2297 www.swagelining.com