The WANZ Guide to Window Installation



Similar documents
The WANZ Guide to Window Installation

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

Installation Window Building In Details

Clad Direct Glaze Window Installation Instructions

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Sun Windows General Information Sun New Construction Window Installation Instructions

Window Installation Instructions

How-To-build guide timber windows

Brick Veneer Construction

300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

FLASHCLAD VERTICAL WEATHERBOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 829 [2013] Appraisal No. 829 (2013) Amended 05 February 2016

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

TECHNICAL MANUAL. airlite.com.au

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)

DE Frame with C Series Sidelight

WELCOME. Recommended Window Installation. 1.5 credits Minnesota Department of Labor and Industry

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

HfHMD uses LP SmartSide siding and trim.

Important Information for Installer & Homeowner

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs

Installing Window and Door Mouldings

Superform Products Ltd.

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Residential Inspection Guidelines

Installation Instructions

PANELIZED HOME INSTALLATION GUIDELINE

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows

InsulView Window Installation Instructions

Residential Roofing Guide

How To Repair A Boat Landing Deck With A Boat Bed

How To Build A Gambrel Roof And A Gable End Roof

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

Tundra Series Windows January 2016

Installation Instructions

Installation Instructions

EDW + FS, VS, VSE, GGL, GGU, GHL. EDW Deck Mounted Skylight and Roof Window Flashing Installation Instructions VAS

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: Purpose

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Technical data sheet PVC Bi-fold doors

2.9 WINDOW & DOOR BUCKS

PART 1 GENERAL 1.1 SECTION INCLUDES

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Hollow or Cinder Block Wall Mount Job Aid

Best Barns USA Assembly Book

Installation An Industry Guide to the Correct Installation of Windows and Doors

EAST LYME HIGH SCHOOL

SUPER SHED. Indoor shelter for your outdoor tools.

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

INSTALLATION INSTRUCTIONS for Vinyl Patio Doors without Nailing Fin (JII015) IMPORTANT INFORMATION AND GLOSSARY

Installation Instructions

KAHU RESIDENTIAL ROOFING RRKA DETAIL LIST

Installation Instructions For Slider Casement Air Conditioners

AAMA Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

Basement Window Installation Guide Hopper and Sliding

Ubiflex. Non-lead flashing system

These instructions will show you how to install an internal door into a non-loadbearing partition wall. The instructions are split into three parts.

4 5/16 Subframe Installation

INSTALLATION OF A BAY WINDOW

Installation Detailed installation instructions are provided which should be strictly followed.

Cable Support System Guide for Andersen Bow, Bay, and Box Projecting Window Units

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Asphalt Shingle Application Requirements

INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg

Window Sill Details for Effective Drainage of Water

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Installation Guide for Andersen Architectural Clad Outswing Commercial Doors

Classic Products, Inc. ClickLock Standing Seam Installation Manual

Electrical Wiring Technical Bulletin

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar

FLAT ROOF BOX SPAN CARPORTS

H-Stud Area Separation Wall System

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

Installation Instructions

Plans for the Construction of. The People s Hive. of Abbé Émile Warré

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Sample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...

application instructions

Leaky Homes Financial Assistance Package (FAP) Repair plan example

Hanson Building Products. precast basement solutions

Transcription:

The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5

2 of 60

Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step P3 Flexible Flashing Tape 10 Cavity Construction 11 Step C1 Sill Support Bar 12 Step C1a Sill Support Full Height 15 Step C2 Position the Unit 17 Step C2a Position the Unit Full Height 19 Step C3 Fixing 20 Step C3a Fixing Full Height 21 Step C4 Air Seal 22 Step C5 Head Flashing 23 Components Cavity Construction 26 Typical Details 27 Masonry Veneer 28 Stucco 30 Bevel Back Weatherboards 31 Rusticated Weatherboards 32 Fibre Cement Weatherboards 33 Horizontal Profiled Metal 34 Fibre Cement Sheet 35 EIFS 36 3 of 60

Direct Fixed Claddings 37 Step D1 Sill Tray Flashing 38 Step D2 Position the Unit 42 Step D2a Position the Unit Full Height 43 Step D3 Fixing 44 Step D3a Fixing Full Height 45 Step D4 Air Seal 46 Step D5 Head Flashing 47 Components Direct Fix Claddings 50 Typical Details 51 Bevel Back Weatherboards 52 Rusticated Weatherboards 53 Vertical Shiplap Weatherboards 54 Board & Batten Weatherboards 55 Fibre Cement Weatherboards 56 Vertical Profiled Metal 57 Fibre Cement Sheet 58 EM6 Test Results 59 4 of 60

Overview In 2009 the Department of Building & Housing invited WANZ to become a part of a working group set up to assist in a technical review of E2/AS1. This was seen by WANZ as an opportunity to address some of the confusion being experienced within the wider building community through having two generic window installation systems available. The net result, in terms of window installation, is E2/AS1 Amendment 5 which effectively merges previous versions of the Acceptable Solution with WANZ WIS. There have of course been some additional items, in terms of window and door installation, included in the document which will be covered off as a part of this guide. Objective The objective of this document is an attempt to offer a better understanding of window and door installation as described in E2/AS1 Amendment 5. The amendment was published in August 2011 and was effective immediately. E2/AS1 Amendment 4 is also able to be used through until 31 January 2012 with Amendment 5 superseding all previous versions from 1 February 2012. The details and drawings used within E2/AS1 to describe window and door installation are two dimensional, cross sectional details which show a required end result. However, often a more in depth sequential approach might describe the process better to the end user. This is what WANZ have attempted to do with this document by providing a step by step guide to the details offered by this latest version of the Compliance Document E2/AS1. Scope Because this document is designed as a Guide to E2/AS1 Amendment 5, its scope is identical to that listed in Section 1 of the Acceptable Solution. E2/AS1 Amendment 5 contains the details for a number of generic solutions covering a majority of the typical building situations encountered on building sites in New Zealand. Obviously there are many more situations that are not covered within its pages. The details for these situations will need to be specifically designed to suit the conditions being encountered. However the principles expressed within the document, and in these pages, will provide a good foundation for the development of specific details. 5 of 60

For the purpose of this guide it is assumed that the building designer has already worked throughh the Risk Matrix and selected an appropriate cladding option, either Cavity Construction or Direct Fixed cladding. Note: Theree are a series of size limitations as expressed in Clause 9..1.10.1 Scope (Pg 103) Where your window or door unit exceeds the limitations set out within this clause, please contact your window supplier for alternativee details. 6 of 60

Opening Preparation The preparation of the wall opening prior to the installation of the window or door is essentially the same regardless of cladding option. The following offers a step by step guide to the process. 7 of 60

Step P1 Preliminary Check Before proceeding with the installation and preparation of the wall underlay, the installer should examine and confirm that the sill trimmer is essentially level, straight and freee of twist. It is particularly important that it is well secured and does not slope toward the interior of the building. If necessary the sill trimmer should be planed to ensure it does not exhibit any of the above conditions. The sill trimmer must be designedd to comply with NZS3604. Detail 1 Note: Projects within the new Extra High wind zone requiree the use of a Rigid Underlay (or RAB) in addition to and underneath a flexible wall underlay. This needs to be taken into account when sizing the windows. 8 of 60

Step P2 Cut The Underlay Clause 9.1.5 a) describes the application of a flexible wall underlay. To achieve this follow these steps; a. b. c. Cut the building underlay at 45 o away from each corner. Fold the flaps tightly into the opening and secure to the framing on all sides. Trim off excess underlay after fixing. Note: Figures 72A & 72B do not show the inner extent of the flexible wall underlay. The industry trend has been to cut this off at the inner corner of the framing as wrapping around sometimes interferes with the internal linings. Ensure the underlay is fixed tightly to the framework. Detail 2 9 of 60

Step P3 Flexiblee Flashing Tape After ensuring the flashing tape to be used meets the criteria set out in Clause 9.1.5 b), follow these steps to satisfy the clause; a. Cut the flashing tape for the sill at least 200mm wider than the opening. b. Fit the tape, as described in the manufacturers literature, with the inner edge of the tape flush with the inside line of the framing, so thatt it extends a minimum of 100mm up each jamb ensuring timber framing is covered. c. Ensure the tape is securely adhered to the underlay on all surfaces and fits tightly into each of the corners. d. Cut two more pieces of tape at least 200mm long and fit into each of the upper corners as described above ensuring timber framing is covered. Detail 3 Note: Ensure all exposed timber is covered, particularly in the corners. This may mean the tape has to extend further than nominated. 10 of 60

Cavity Construction Clause 9.1.10.2 describes the basics of window installation for wall claddings over a cavity. Note: The use of a sill tray with cavity construction should be avoided. Its use will impact on the airflow into the cavity around the windoww and therefore its ability to pressure equalise. If a sill tray is desired then a Direct Fix type solution for the window installation must be created. 11 of 60

Step C1 Sill Support Bar Clause 9.1. 10.5 b) v) describes the requirements of the Sill Support bar in terms of compliance with E2/AS1. There are some important points to note; a) Support is required on all window and door units with a trim opening over 600mm wide, b) The sill support bar must comply with EM6, E2/ VM1 & B2/AS1, c) Must be installed prior to the window or door unit. d) The bar must be fitted in a manner that does not trap water on the sill trimmer The comment following Clause 9. 1.10.5 b) v) makes reference to ensuring the support bar is appropriate for the application for which it is being used. The EM6 test will allow the calculation of an acceptable weight limit for the support mechanismm being used and the size and frequency of the fixings required to achieve the support. The windoww manufacturer can help select the appropriate bar and fixing method. Clause 9.1. 10.5 c) also makes this note regarding the design of the sill support bars. 12 of 60

Figure 72B shows the general arrangement of the sill for a windoww installed into wall claddings, over a cavity. Note: Figure 72B indicates that the sill support bar may be up to 100mm short of the trim opening at either end. It is recommended that the bar installed to the full width of the opening to ensure it picks up the window or door frame support blocks. However in some cases the use of non proprietary corner soakers may require shortening of the bar. 13 of 60

The range of WANZ sill support bars, as described on the Components page (Pg 26), offer not only support to the window or door unit, but also drainage and ventilation of the trim cavity. The WANZ bars have been tested to EM6 and have demonstrated compliance with E2/VM1. In order to comply with these documents they must be used in a continuous length across the trim opening. Detail 4 a. The sill support bar is positioned below the opening, and set so that the upper edge sitss a minimumm of 5mm above the sill trimmer The WANZ sill support bar is supplied with locator blocks which are a quick and easy method of setting the bar in the correct position. Detail 5 The locator blocks are designed to be re used but can remain if desired. b. After fitting a locator block at each end of the bar, position it into the trim opening. Using a level find the high end of the bar and fix the bar in place. Now adjust the other end of the bar to level and fix this end. Detail 6 Note: The WANZ Sill Support Bars are designed to be fixed with 10g SS screwss positioned at each end and at 300mm max centres between. For confirmation of fixing type and centres, refer to the window manufacturers documentation. 14 of 60

Step C1a Sill Support Full Height For windoww or door units that extend to the floor theree are two sill support bar options available; a) Where the sill support bar is installed as described in Step C1 above. The major difference heree would be where the bar is being fitted to a concrete floor. In this case the fixing sizes and positions would be identical except that the screws would drive into Rawlplugs or similar. If the installer prefers to use masonry anchors, then use 6mm anchors @ 300mm centres as described above. Ensure edge clearances as recommended by the anchor supplier are observed. Detail 7 Note: Full height units are often heavier than other windows and doors, or are subject to other loads, it is important that the correct bar is selected for the unit. 15 of 60

b) Included in the WANZ Sill Support Bar range is a bar designed for situations where there is insufficient room to fit a standardd bar, i.e. units fitted as an option over a masonry veneer rebate or those set over an enclosed deck. The full height bar is designed to be fixed vertically into the top of the floor / rebate instead of into the face of the floor. Detail 8 As with the standard bar it must be installed level. This may require packing between the substrate and the bar to ensure weight is adequately supported. For fixing type and centres refer above. Note: Figure 73D, describes an alternative sill support detail for masonry veneer, which includes a poured concretee extension to the slab edge under the windoww or door and uses a sill tray flashing as detailed for direct fixed cladding situations. 16 of 60

Step C2 Position the Unit a) Before positioning the window or door unit into the opening ensure that, where applicable, that the sill corners have been fitted with corner soaker as described in Clause 9.1.10.5 c). Check with your window manufacturer regarding the types of cornerr soaker used with their systems and that they are indeed applicable. b) Ensure the unit is positioned so that; i) The unit is positioned 5mm forward of the exterior cladding line, as described in Clause 9.1.10. 2 d), ii) The interior linings finish in the correct positions, iii) The unit is sitting correctly on the sill support bar, Detail 9 17 of 60

iv) Once the installation has been completed, that the required cover over the exterior cladding as described in Clause 9.1. 10, has been achieved. 18 of 60

Step C2a Position the Unit Fulll Height Figure 17C, describes the sill details for full height window and door units for cavity construction. The positioning of the unit is essentially the same as described in Step C2 above. Note: Many find the raised sill to be undesirable. If this is the case then a rebated sill detail would need to be designed specifically to suit the project and is therefore an Alternativee Solution. 19 of 60

Step C3 Fixing a) Insert flat packers between the wall framing and the window or door reveals at the head, sill and jambs at fixing points. DO NOT use wedges. b) Fix off the unit as described in Clause 9.1.10.8. Detail 10 Note: This Clause describes the fixing method for typical windows and doors. Larger units or those subject to higher windloads may require additional fixing. If in doubt contact your window manufacturer to confirm. c) After fixing the unit in place, remove the packers from the head of the unit to allow any potential settlement of the building structure. Detail 11 20 of 60

Step C3a Fixing Full Height For full height units fixed to concretee floors replace the nail fixings with 10g screws driven into Rawlplugs or similar. If the installer prefers to use masonry anchors, then use 6mm anchors @ 300mm centres as described above. Ensure edge clearances as recommended by the anchor supplier are observed. Detail 12 21 of 60

Step C4 Air Seal The Air Seal is designed to hold pressure in the trim cavity to enable pressure equalisation to occur. Typically the Air Seal is a low expansion polyurethane foam installed over a PEF backing rod, as described in Clause 9.1.6. Detail 13 Note: E2/AS1 makes the comment below regarding air seals. 22 of 60

Step C5 Head Flashing Clause 9.1. 10.4 describes the basics of head flashings. Specifically paragraphs d) and e) apply to cavity construction. Table 7 describes the covers required by head flashings. 23 of 60

The most common form of window or door head flashing is the extruded aluminium version, chosen primarily becausee of its consistent dimension and ease of installation. The versions supplied by WANZ are available in 5mm increments to cover a wide range of claddings. These increments offer a nominal 5mm gap between the back of the flashing and the face of the window. With Amendment 5 to E2/AS1 the design of the vertical upstand of the flashing has been modified to accommodate the recently introduced Extra High wind zone. Therefore the upstand height on all extruded head flashings has been increased to 65mm to comply with Table 7 and Clause 4.5.1 2). Because we are unable to extrudee aluminiumm head flashings with a hem on the top edge, those required in an Extra High wind zone will have to be folded. Whilst this version of E2/AS1 does not nominate a length for the head flashing, it is industry standard to extend these 20mm past each side of the window, i.e. windoww width +40mm. Detail 14 Stop ends for extrudedd aluminiumm head flashings, as describedd in Clause 9.1. 10.4 d) i), will be supplied as an applied injection moulded plastic item which is fitted on site. Detail 15 24 of 60

Windows or doors that extend to the soffit do not require a head flashing but instead will have a trim fitted as shown in Figure 8A. Figure 71, describes the general sealing of the head flashing and the wall underlay options. Whilst these details are shown as direct fix situations the same will apply to cavity construction. Note: Detail (c) shows sealant between the top of the window or door flange and the underside of the head flashing. Use of a foam tape in this case might simplify the application. Check with your T.A. whether or not this is appropriate. 25 of 60

WANZ Components Cavity Construction 26 of 60

Cavity Construction Typical Details 27 of 60

28 of 60

29 of 60

30 of 60

31 of 60

32 of 60

33 of 60

34 of 60

35 of 60

36 of 60

Direct Fix Claddings Clause 9.1.10.2 describes the basics of window installation for direct fixed wall claddings. 37 of 60

Step D1 Sill Tray Flashing Clause 9.1. 10.5 a) describes the requirements of the Sill Tray Flashing in terms of compliance with E2/AS1. The use of flat sill tray flashings is quite a departure from the previous sloping version. To compensatee the design of the flashing has been reviewed. There are a couple of important points to note; a) The sill tray flashing is to extend beyond the inside line of the aluminium windoww or door frame, including the condensation channel. b) The sill tray flashing is to have an 8mm minimum upstand to the inside edge. c) The sill tray flashing is to have a minimum 35mm cover on the cladding and is to extend the full width of the trim opening. d) The sill tray flashing requires forward sloping end dams. The range of WANZ extruded aluminium sill tray flashings, as described on the Components page (Pg 50) include each of the above features and also include a rear fixing tag to ease installation. Also available is an injection moulded stop end which avoids the difficulties in folding extruded aluminium. The stop end snapped off to the correct length and is sealed in place on to each end of the tray. Detail 16 38 of 60

Figure 72A describes the general arrangement of the sill for a window installed into a wall with direct fixed claddings. a) Prepare the framed opening, by cutting and fixing the wall flexiblee underlay and applying the flexible flashing tapes, as described in Steps P1 through P3. Detail 17 39 of 60

b) Install the sill tray flashing (and stop ends) into the trim opening level, straight and fitted tight to each jamb, packing as required. Ensure that it does not slope toward the interior. At this stage the trim opening is considered between studss and does not include the jamb battens. Detail 18 c) Screw fix into the sill trimmer through the rear leg of the sill tray flashing using either clouts or 8g SS screws positioned 150mm max from each end and at 450mm max centres between. With some thicker claddings the front edge of the sill tray flashing will require additional support. This is achieved through the use of an angle support fitted to the face of the sill trimmer prior to the installation of the flashing. Detail 19 Note: It is important the angle support is installed level regardless of the line of the sill trimmer. It should be fixed with 10g SS screwss positioned at each end and at 300mm max centres between. d) In order to support the weight of the window or door frame adequately the unit must be blocked up off the sill tray flashing. If your window or door has not been fitted with proprietary frame blocks then an aftermarket item will need to be sourced and applied in appropriate locations. Refer to your window manufacturer for details. Detail 20 40 of 60

e) Figure 72A describes the addition of full height battens to each jamb of the trim opening. These battens are fitted after all of the trim opening preparation has been completed, including flashing tape, sill tray flashings and end stops. If the battens do not span the entire width of the framing then position them to align with the inner and outer faces of the framing, as shown. Detail 21 Note: It is important to discuss the building details with your window manufacturer to ensure the window sizes are calculated correctly. f) The cladding is now installed and must be notched around the sill tray flashing and support angle where it is used. Detail 22 41 of 60

Step D2 Position the Unit a) Before positioning the window or door unit into the opening ensure, where applicable, that the sill corners have been fitted with corner soaker as described in Clause 9.1. 10.5 c). Check with your window manufacturer regarding the types of cornerr soaker used with their systems and that they are indeed applicable. b) Ensure the unit is positioned so that; i) The unit is positioned 5mm forward of the exterior cladding line, as described in Clause 9.1. 10.2 b), ii) The interior linings will finish in the correct positions, iii) The unit is sitting correctly on the sill tray flashing, Detail 23 iv) Once the installation has been completed, the required cover over the exterior cladding as described in Clause 9.1. 10, has been achieved. 42 of 60

Step D2a Position the Unit Full Height Figure 17D, describes the sill details for full height window and door units for cavity construction. The positioning of the unit is essentially the same as described in Step D2 above. However, many find the raised sill to be undesirable. If this is the case then a rebated sill detail would need to be designed specifically to suit the project. 43 of 60

Step D3 Fixing a) Insert flat packers between the wall framing and the window or door reveals at the head, sill and jambs. DO NOT use wedges. b) Fix off the unit as described in Clause 9.1.10.8. Detail 24 Note: This Clause describes the fixing method for typical windows and doors. Larger units or those subject to higher windloads may require additional fixing. If in doubt contact your window manufacturer to confirm. c) After fixing the unit in place, remove the packers from the head of the unit to allow settlement of the lintel. Detail 25 44 of 60

Step D3a Fixing Full Height For full height units fixed to concrete floors replace the nail fixings with 8g screws driven into Rawlplugs or similar. Detail 26 45 of 60

Step D4 Air Seal The Air Seal is designed to hold pressure in the trim cavity to enable pressure equalisation to occur. Typically the Air Seal is a low expansionn polyurethane foam installed over a PEF backing rod, as described in Clause 9.1.6. Detail 27 Note: E2/AS1 makes this comment regarding air seals. 46 of 60

Step D5 Head Flashing Clause 9.1. 10.4 describes the basics of head flashings. Table 7 describes the covers required by head flashings. The most common form of window or door head flashing is the extruded aluminium version, chosen primarily because of its consistent dimension and ease of installation. The versions supplied by WANZ are available in 5mm increments to cover a wide range of claddings. These increments offer a nominal 5mm gap between the back of the flashing and the face of the window. 47 of 60

With Amendment 5 to E2/AS1 the design of the vertical upstand of the flashing has been modified to accommodate the recently introduced Extra High wind zone. Whilst this wind zone does not apply to direct fixed claddings, in an attempt to minimise the number of flashing options, the upstand height on all extruded head flashings has been increased to 65mm to comply with Table 7 and Clause 4.5. 1 2) above. Whilst this version of E2/AS1 does not nominate a length for the head flashing, it is industry standard to extend these 20mm past each side of the window, i.e. windoww width +40mm. Detail 28 Clause 9.1. 10.4 c) states; Detail 29 Note: Windows or doors that extend to the soffit do not require a head flashing but instead will have a trim fitted as shown in Figure 8A. 48 of 60

Figure 71, describes the general sealing of the head flashing and the wall underlay options. Note: Detail (c) shows sealant between the top of the window or door flange and the underside of the head flashing. Use of an appropriate foam tape in this case might simplify the application. 49 of 60

WANZ Components Direct Fix Claddings 50 of 60

Direct Fix Claddings Typical Details 51 of 60

52 of 60

53 of 60

54 of 60

55 of 60

56 of 60

57 of 60

58 of 60

EM6 Test Reports 59 of 60

60 of 60