Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL SYSTEMS



Similar documents
FILLING AND PURGING THE SYSTEM

Flow Measurement Options for Pipeline and Open Channel Flow

Inline Chlorinator Chlorine Chemical Feeder

Watts Pure Water Systems

Reduced Pressure Principle Assembly 3 Valve Procedure

B150 Series Commercial Brewer. Direct Plumb Kit

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Heating Water by Direct Steam Injection

How To Replace A Reverse Osmosis Water Tank

DC400 Dispensing Cutoff System

How To Install A Mazzei Injector

OPL BASIC. Dosing System for Professional Laundry machines. Contents

: Service Information: Fuel Tank System

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

Performing Inventory Control For Storage Tanks

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

C. starting positive displacement pumps with the discharge valve closed.

Air Eliminators and Combination Air Eliminators Strainers

Doing Inventory Control Right For Underground Storage Tanks

SunMaxx Solar Filling Station Operating Instructions

VOYAGER 570G. 744A Sprayer Control

NFPA31FuelOilPiping 1 Revised

FERTIGATION. Lawrence J. Schwankl

Factory owners must ensure the boiler is:

EcoSoft Water Softener. General Installation Guide

ENGINEERING REPORT TEST PROCEDURES FOR MECHANICAL LEAK DETECTORS

15CI and 25CI Reversing Motor Pumpset Owner's Manual

A Job Safety Execution Plan is required. mixtures of the above called, natural gas liquids (NGL's) refined products and their components

Stenner Pump Chlorinator Installation & Start Up Guide

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

MODEL G300 BRAKE BLEEDER

DIESEL FUEL CONDITIONING

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Standard Hydraulic Piping Flushing Procedure

Sanitary Type Electronic Flow Switches

TROUBLESHOOTING GUIDE

Method to Determine PERFORMANCE OF INDIRECT-FIRED WATER HEATERS March 2003 Edition

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Section 8 Storage Tanks & Equipment

NITROUS TRANSFER PUMP INSTRUCTIONS

Injector Max Machine

How To Clean Up A Reactor Water Cleanup

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Septic Tank to Cistern Conversions. Saving Water & Saving Money

55-Gallon Dispenser Package

AIR OPERATED OIL PUMPS AND KITS

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

Pro-OX 7800 Iron Filter Installation & Start-Up Guide

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

lifting stations motralec

WARNING WARNING TABLE 1.

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

NOTIFICATION OF PERFORMANCE TESTING FOR GASOLINE DISPENSING FACILITIES (GDFs) NESHAP 40 CFR, Part 63, Subpart CCCCCC (Sections

Quik Lining Systems Heater Owners Guide

Air Conditioner Water Heater Model ACWH18

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Your Portable Oxygen System. Use & Care Guide

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Morrison Bros. Co. General Product Specifications

Used Fluid Handling Portable Used-Oil Gravity Drains

FLASH TANK ECONOMIZER PRODUCT GUIDE

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Fire Pump Plan Review March 2010

Air/Vacuum Valves. Removal of Air from Pipelines. Allow the Entry of Air into Pipelines. Application:

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

OREGON FIRE CODE Interpretations and Technical Advisories

Lubricant Transfer, Storage & Dispensing

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

OPERATING INSTRUCTIONS FOR THE MODEL 210B-2 SRA

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. Dry Cleaner Compliance Calendar 2012

FLUID FLOW Introduction General Description

Inventory Control for Underground Storage Tanks

Problems with Hypo: Best Design Practices for Smooth and Efficient Sodium Hypochlorite Feed Systems Chad Hantelman, City of Bremerton Jeff Zahller,

PC1130 Electric Air Compressor

FIBERGLASS UNDERGROUND STORAGE TANKS Special Installation Instructions for New York City Gasoline and Diesel Motor Fuels

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

TROUBLESHOOTING FLOW CHART

Zenith Solar thermal 4.5m pump station Installation manual

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

GEET Fuel Processor Plans

LNG Fuel Tank System LNG Tank overview

Iron Air Charge 2510-SXT Installation & Start-Up Guide

Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized

INSTRUCTION MANUAL A REVISION A. Series E1 and E3 Instant Hot Water Recirculating Systems

Flushing and Cleaning the A/C System

ROUGHNECK II Pumpless Drain

Medical Air Systems: Scroll

After the reactor has been running and the air in the chamber has been purged the co2 can be introduced and the dial in process can begin.

Signature and ISX CM870 Fuel System

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

LIMITED LIFETIME WARRANTY

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

DC Series Digital Conversion Alarm Operator s Manual

Petroleum Storage Tank Compliance 101

Transcription:

1 TM INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL SYSTEMS When the HI-FLO Metering Head is attached to a tank, the tank will be pressurized to the same pressure as the irrigation system. Before attaching a tank or other storage device to the irrigation system, make sure the tank is capable of safely containing the pressure of the irrigation system. EZ-FLO assumes no responsibilty for failures of tanks that are not manufactured by EZ-FLO. FOR ASSISTANCE VISIT OUR WEBSITE AT www.ezflofertilizing.com CALL TOLL FREE 1-866-393-601 1, EZ-FLO Fertilizing Systems 1, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com

TM SYSTEM COMPONENTS Fill Valve Air Vent Valve Metering Head Return Shut Off Valve 1 Metering Gauge Shut Off Valve Bypass Flow Adjustment Valve Bypass Line Return Line Water Supply Line Purge and Drain Valve Return Saddle Connection Saddle Connection Flow Irrigation Main Line 1, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com

TM Install Saddle Venturi Connection Step 1 - Drill (2) - 1 1/4 holes minimum of 6 apart, in the irrigation main line near the installation location of the EZ-FLO System. Make sure there is enough room for the saddles to attach snugly to the pipe. Caution: DRILL SLOWLY TO PREVENT PIPE FRACTURE Hole Saw or Reaming bit is recommended. Drill 2-1 1/4 Holes Pump Station X X Irrigation Mainline Flow Direction To Irrigation System Step 2 - Attach saddle to pipe. The blue connection should be installed in the first drilled hole in the irrigation main line with the venturi probe ing facing into the water flow. The green connection should be installed in the second drilled hole in the irrigation main line with the venturi probe ing facing away from the water flow. Green Connection ( Return) Blue Connection () Flow Direction COMPLETED SADDLE ASSEMBLY 14, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com

1 TM To connect the system to the irrigation line Step 1 - Connect tubing to the system and to the irrigation line. Connect the water supply WS tubing to the water supply connection on the irrigation main line and tank mixing head. Connect the fertilizer return FR tubing to the fertilizer return connection on the tank metering head and the irrigation main line. Connect the tubing to the air vent valve AVV to direct air and fluid away from the tank. (Tubing sold separately). Fill with water and pressure test all connections. Fill the tank with water and pressure test the system. FR AVV WS Step 2 - There are 2 water supply connections on the metering head. One is for liquid products and one is for dry, water soluble powder products. Connect the water supply line to the metering head connection based on the type of product you will be putting in the tank. To change between liquid and dry products, disconnect the Metering Gauge Assembly from the Metering Head by removing the assembly at the union closest to the Metering Head and connecting it to the desired port. Connect the Vent Valve to the port that is not connected to Metering Gauge Assembly. The simple diagram below shows a top view of the various configurations: Water Soluble Products FR WS Return Flow 1 Return Air Vent Valve 1 Metering Head 1 Metering Gauge Assembly 14, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com

1 1 TM To fill the tank with product The system can be filled with any liquid or water soluble product in concentrated form. No premixing or pre-dilution is required. Water soluble products may be easier to pour into the tank if they are mixed with enough water to turn them into an easy to pour slurry. Before filling close and valves in this order: 1. Close both shut off valves 2. Open the air vent valve AVV to exhaust pressure 3. If you are refilling, the purge and drain valve PV to drain the water from the system. 3. When the tank is completely drained, close the purge and drain valve PV 4. Open fill valve FV FV close AVV close PV closed Premium Fertilizer To fill with water soluble products: No premixing required. Water can be added to the fertilizer to create an easy to pour slurry if that is preferred. Make sure the system is set up to inject water soluble powders. To do this, connect the Gauge Assembly to the water in dry products connection (see step 2 under on the previous page). 1. Connect the high capacity funnel HCF to the fill valve FV 2. Pour the fertilizer directly into the high capacity funnel HCF 3. Fill the tank the rest of the way with water. HCF To fill with liquid products: Make sure the system is set up to inject liquid products. To do this, connect the Gauge Assembly to the water in liquid products connection (see step 2 on the previous page). 1. Attach the high capacity funnel HCF or fill hose from product storage tank to fill valve FV. Liquids can also be filled through the Purge and Drain Valve PV, at the bottom of the tank. The PV can be used to refill the tank when it is only partially empty by filling from the bottom and letting the water in the tank drain from the fill valve FV. 3. Fill tank the rest of the way with water. 14, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com

TM After Filling Step 3 - Get system ready to begin injecting FV closed Open and close valves in this order. 1. Close fill valve FV 2. Open shut off valves Step 2 - Set system feed rate AVV 1 With the irrigation system operating, 1. Open air vent valve AVV until air purged from the tank and lines 2. Open the meter valve MV to allow water flow into the tank. The meter valve will register maximum flow until the tank is completely full of water and the tank pressure is equal to the line pressure. MV Note: On the initial fill, the tank will stretch and expand for the first few minutes. When the tank has fully expanded the tank pressure will equalize with the line pressure and the feed rate can be set. PUF AGT 3. The meter registers the gallons per hour being injected. This reading will change as the flow rate of the irrigation system changes. To accurately set the feed rate, set it when the irrigation system is running at its normal operating GPM. To set the feed rate: Know the desired dispensing time, the upcoming irrigation schedule and the unit size. For example - a. Liquid products - Note: Any amount of liquid product can be added to the system up to the total amount of the tank s capacity. If adding less than the full tank capacity, mix the solution with water. This will provide a 4 gallon mix that will be injected at the rate shown on the metering gauge. if the irrigation schedule is 6 hours per day, the desired dispensing time is 3 days and the system has a 4 gallon capacity, set the meter to 2. gallons per hour. At this rate 4 gallons of product will dispense in 18 hours. 4 gallons / 18 hours of injection time = 2. gallons per hour b. Dry water soluble products - Note: Approximately two pounds of water soluble product is delivered in each gallon of the injected mix and the system will hold up to pounds of dry product for every gallon of capacity. If the irrigation schedule is 6 hours per day, the desired dispensing time is 3 days, the system has a 4 gallon capacity and 40 pounds of dry product has been added to the tank, set the meter to 12. gallons per hour. At this rate 40 pounds of dry product will dispense in 18 hours. 40 pounds / 2 pounds per gallon = 22 gallons to be injected / 18 hours of injection time = 12. gallons per hour If you have the same conditions but only want to put 0 pounds of dry product in the system, set the meter to 2.7 gallons per hour. 0 pounds / 2 pounds per gallon = 0 gallons to be injected / 18 hours of irrigation time = 2.7 gallons per hour Special Note: Normally the injectors are set once to dispense the product over three to five days. Longer dispensing times improve coverage rates and nutrient uptake. 0214 14, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com

EZ-FLO HI-FLO By-Pass Operation Typically the EZ-FLO HI-FLO systems will operate perfectly fine without the use of a bypass / venturi relief valve, but if you are injecting into flow streams above 10 GPM the valve may be required. To properly calibrate and adjust: 1.) Make sure the tank is completely filled (fluid or supplement) so no air is present. a. Purging the ½ tubing lines is not necessary as all air will evacuate automatically 2.) Start with the by-pass valve in the full closed position a. Allow the irrigation system to reach maximum flow b. The bypass valve and flow meter cannot effectively be configured at flow ranges below the maximum flow rate 3.) Once the mainline is operating at full flow set the flow meter to the desired feed rate a. Do not adjust the bypass yet, it should still be in the full closed position 4.) Observe the flow meter float and its ability to maintain the set level for a period of 2 to 3 minutes. a. The float will bounce due to fluctuations in pressure but quickly recover to the selected setting, this is normal operation. b. Continue to observe and confirm the float is returning to the appropriate level and not steadily dropping.) If the float continues to return to the appropriate level and the irrigation system is operating at full flow, no adjustment needs to be made to the bypass valve. 6.) While observing, if the float fails to return to the appropriate level and steadily to lower levels the bypass valve will need to be ed a. When the float steadily drops, increase the observation time to minutes to insure it does not recover 7.) To adjust the bypass valve, simply the valve to the full position. a. This will instantly relive the turbulence in the venturi fitting 8.) Once in the full position, slowly close the valve until the float begins to fall again a. Once the float falls, adjust the valve slightly towards the position until the float maintains its set level 9.) After the float is stabilized, observe operation for 3 to minutes and insure the bypass valve is appropriately set..) Now the flow meter may be set to the desired level of injection The bypass valve is now configured and it is recommended the handle be removed and set aside to avoid any future tampering. If the bypass valve is ever accidentally adjusted the above steps may be repeated. Special notations: If the bypass valve is too far, the system will lose the ability to inject at higher rates. Depending on the desired level of injection, this may not be an issue. When the bypass valve is too far closed, the injection may suddenly stop.