Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible



Similar documents
Consumable Parts Catalogue Ver.3.06

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

Micro Cryo-Trap Model 971

SCION SQ Series GC-MS

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Analyzing Small Molecules by EI and GC-MS. July 2014

Series 2. Air Server. Options for UNITY 2. A robust, cryogen-free solution for round-the-clock on-line air monitoring

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

AMD Analysis & Technology AG

Fractional Distillation and Gas Chromatography

ORGANIC SAMPLE PREPARATION

Split / Splitless Injection for Capillary GC

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

XFA 600 Thermal Diffusivity Thermal Conductivity

Gas Chromatograph GC Consumables. p/n:

23 The Thermal Conductivity Detector

Bridging the analytical gap

On-line Dissolved Gas Analysis

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Expectations for GC-MS Lab

Characterization of Polymers Using TGA

Indoor Air Comfort Test Report

Analysis of Phthalate Esters in Children's Toys Using GC-MS

Gas Chromatography Liner Selection Guide

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

A Comparison between EPA Compendium Method TO- 15 and EPA Method 8260B for VOC Determination in Soil Gas

DMA-1 Direct Mercury Analyzer

Process Instrumentation

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Agilent 7697A Headspace Sampler Data Sheet

GC-xt. The most flexible GC /GC-MS liquid sample injector

Background Information

Flow Injection Analysis

Identification of Arson Accelerants by Gas Chromatography

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

How To Test For Contamination In Large Volume Water

CHROMOCTANE O N LINE ANALYZER

ß-CYCLODEXTRIN SYNONYMS

Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

Determination of N-cyclohexyl-diazeniumdioxide (HDO) containing compounds in treated wood using GC-MS

THE PRODUCTION OF ELECTRICITY FROM WOOD AND OTHER SOLID BIOMASS

Transformer Oil Gas Analysis

QGA Quantitative Gas Analyser

MILESTONE H E L P I N G C H E M I S T S

Aromatic plants: from extraction to analysis

CHARACTERIZATION OF POLYMERS BY TMA. W.J. Sichina, National Marketing Manager

Sterilization methods and equipment Lab 1-2

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Series 2. Continuous monitoring of trace chemical vapours

Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)

Multifunctional Autosampler AOC-6000 C146-E272A

MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# RFQ)

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Fundamentals of Mass Flow Control

How To Use Gc-Ms

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Thermo Scientific ConFlo IV Universal Interface

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Application of Aroma Release Monitoring in Real Time as a Powerful Tool to Understand Consumer Perception

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

The art of elemental analysis

Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004.

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Setting up a Quantitative Analysis MS ChemStation

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

The PMI Advanced. BET SORPTOMETER BET-201-AELC-2OS Not just products...solutions!

Theory and Instrumentation of GC Introduction

THE BASICS Q: What is VOC? Q: What are flashing losses/voc emissions from hydrocarbon storage tanks? - 1 -

High-Throughput 3-D Chromatography Through Ion Exchange SPE

WHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS. HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE

Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012.

Advancing the State of Analytical Science. for air, water and soil analysis. and beyond

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

HFM Heat Flow Meter Thermal Conductivity Analyzer

Focus XC. Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options

Pesticide Analysis by Mass Spectrometry

AUTOMATED SAMPLE PREP CAPITAL EXPENDITURE JUSTIFICATION REPORT

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Appendix 5 Overview of requirements in English

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

CHAPTER 7: REMEDIATION TECHNOLOGIES FOR CONTAMINATED GROUNDWATER

COAL, OIL SHALE, NATURAL BITUMEN, HEAVY OIL AND PEAT Vol. II -Extraction of Oil Shale: Surface and In Situ Retorting - Victor Yefimov and Shuyuan Li

Transcription:

Multi-Shot Pyrolyzer EGA/PY-3030D Flexible Versatile Reproducible

Why Evolved Gas Analysis? Why Pyrolysis? Today, analytical pyrolysis encompasses much more than simple flash pyrolysis of polymeric materials. Virtually any material (liquid or solid) can be characterized using an array of techniques, which are designed into a modern day, Multi-Functional Pyrolysis System. Consider how these techniques can help you quickly solve the most difficult analytical challenge: Analytical Techniques: Evolved Gas Analysis (EGA) Pyrolysis (PY) Reactive Pyrolysis (RxPY) Multi-step Thermal Desorption (TD) Thermal Desorption followed by Pyrolysis (Double-Shot) Heart cuts based on the EGA thermogram UV Irradiation Conventional sorbent based thermal desorption High pressure, high temperature reaction chemistry Examples of what can be done with a pyrolysis system, like the EGA/PY-3030D: Thermal Desorption-GC/MS Phthalates in PVC Residual bisphenol A in polycarbonate Herbicides in wood pulp Volatiles formed during irradiation Hydrocarbon profiles of various shale oils High temperature fuel additives Outgassing of electronic components Outgassing of medical devices Reactive Pyrolysis GC/MS - in less than one hour Fatty acids in a grain Fatty acids in a variety of biomass materials Fatty acids in cosmetics Double-Shot GC/MS Additives in rubber Additives in paints, varnishes Contamination of disk drives What's new from Frontier Laboratories? Why are most laboratories integrating the Frontier Multi-Shot Pyrolyzer into their mainstream analytical protocols? Guaranteed reproducibility and accuracy Every facet of the system is designed to ensure reliability and data quality. All wetted surfaces are quartz, there is no transfer line, there is no cross contamination. Versatility The Pyrolyzer can be configured to analyze C2 vapors, C100 solids and everything in between. Increase laboratory productivity Sample prep takes less than five minutes; the low mass ceramic furnace heats and cools in record time. Analyze any sample matrix Virtually any material (gas, liquid or solid) can be chemically characterized. Tools to help understand the data F-Search software and four MS libraries utilize MS and GC data to simplify data interpretation. Pyrogram of polyethylene ( 600 C) with FID Precision and accuracy reflect the thermal homogeneity of the system thermal gradients between the 3030D and GC are eliminated by replacing the standard septum nut with one that fits snugly into the unique heat sink adapter at the bottom of the pyrolyzer. The effectiveness of this design is underscored by the C100 chromatogram. guaranteed reproducibility page 2

Pyrolyzer EGA/PY-3030D Frontier Laboratories new Multi-Shot Pyrolyzer EGA/PY-3030D is based upon the proven superiority of their patented vertical micro furnace, but everything else is new. A low mass ceramic heater heats and cools quickly. The needle interface has been re-designed to ensure thermal uniformity. The temperature control algorithm literally guarantees temperature reproducibility (±0.1 C) and the operating software has a number of new features. The concept is sound, the design is simple and the engineering first rate; a two year warranty is standard from day one! Two new samplers give the 3030D Pyrolyzer an even larger role in the analytical laboratory. Odors and other VOCs can be concentrated on conventional sorbents like Tenax and thermally desorbed using the TD Sampler. High pressure, high temperature chemistry can be investigated using the micro reactor sampler. Couple these two samplers with the many innovative accessories that can be added to the 3030D with the power of F-Search Software you will agree that Frontier is all about analytical performance, versatility and capability. Sampler - holds and positions the sample Sampler - purge vent Ceramic furnace (ambient + 10 to 1,050 C) Instrument specific heater adapter Cooling fan Quartz pyrolysis tube Cooling air Insulation Interface heater (40-450 C) Deactivated needle interface Versatility: One instrument, multiple analytical techniques The Pyrolyzer EGA/PY-3030D can be configured with five different samplers (shown) and other accessories. By simply changing the sampler, the 3030D can be used to make liquid injections, desorb sorbent tubes or SPME fibers, investigate reactions at high pressure and even monitor the volatiles released as a material is UV irradiated. There is a configuration for nearly every analytical challenge: from C2 to C100, literally ethane to Shale! For more information see www.frontier-lab.com (a) (b) (c) (d) (e) Std Std New New (a) Liquid Sampler (b) Double-Shot Sampler (c) Micro TD Sampler (d) Micro Reaction Sampler (e) UV-Irradiator Sampler guaranteed reproducibility page 3

Material characterization using the multi-mode capability of the Frontier Pyrolyzer EGA/PY-3030D Abstract: When working with challenging samples, such as an eyeliner pencil, the first step is to characterize the sample using evolved gas analysis (EGA-MS). Analysis of the EGA thermogram provides information about the thermal complexity of the sample, the nature of the polymer and the presence or absence of specific compounds of interest. EGA will help the analyst select the next step in the process. A good example of using EGA to suggest what analysis will yield the most useful information about the sample is the characterization of a commercial eyeliner. Like many cosmetics, eyeliner is a complex mixture of compounds ranging from volatiles to polymers. The eyeliner is placed directly into the sample cup and analyzed directly; there is no sample prep. eyeliner sample cup Evolved gas analysis (EGA-MS) EGA-MS requires a direct connection between the split/splitless injection port and the detector. This is done using a deactivated 0.15mm i.d. capillary tube (EGA tube). As the sample is heated the evolved gases flow to the detector. Volatile components (additives etc.) EGA thermogram reflects thermal properties of the entire sample The EGA thermogram of the eyeliner (on the right) has three peaks: A, B, and C which are the volatiles in the sample and two peaks: D and E which originate from the polymeric portion of the sample. F-Search displays two-dimensional multi-ion mass chromatograms The data indicates that peaks A and B contain multiple components. Peaks D and E can be tentatively identified using F-Search and the EGA-MS library. Polymer Evolved gas analysis EGA tube (L=2.5m, i.d. = 0.15mm) Single-Shot Double-Shot Heart-cut EGA Separation column (L=30m, i.d. = 0.25mm) Vent-free GC/MS adapter Using Vent-free adaptor, columns can be replaced without venting the MS. Switching between EGA tube and separation column Single-Shot analysis (PY-GC/MS) The sample cup free-falls into the pyrolyzer furnace. The sample temperature goes from ambient to the pyrolysis temperate in less than 20msec. Pyrolysis occurs instantly and the pyrolyzates are introduced into a GC separation column. The pyrogram of the eyeliner, shown below, was obtained at 550 C, which is 50 C higher than the temperature indicated by the EGA thermogram. The single-shot method is simple, however, the pyrogram represents the degradation of all organics in the sample which sometimes makes it difficult to interpret. Double-Shot analysis (TD/PY-GC/MS) Double-shot analysis provides information about the volatile constituents and the polymeric content of the sample. The eyeliner is analyzed in two steps. STEP 1: volatiles evolving from the sample are analyzed by thermal desorption (TD)-GC/MS. This process results in a total ion chromatogram which can be used to identify the individual compounds in the sample. STEP 2: the residual sample is pyrolyzed at a temperature determined by the EGA data. The pyrogram facilitates the identification of the polymeric content of the sample. The total ion chromatogram shown below includes that portion of the sample (peaks A, B, and C) that evolves between 100 and 300ºC. A MicroJet Cryo-Trap is used to focus the individual compounds during the desorption interval at the head of the column. This maintains peak fidelity and column resolution. Shown below is a pyrogram of peaks D and E. Because fractions A C have already been extracted from the sample, the peaks in the pyrogram are pyrolyzates of the polymer. The eyeliner polymer contains acrylic resin and dimethylpolysiloxane. Heart-cut analysis (EGA-GC/MS) Vapors evolving from each EGA thermal zone are selectively introduced into the GC separation column and analyzed by GC/MS. Using the selective sampler and the MicroJet Cryo-Trap up to eight thermal zones can be isolated and analyzed. Shown below are the chromatograms obtained when each of the EGA thermal zones (A E) is analyzed sequentially. The entire method can be automated using the auto-shot sampler. A: Peaks (A+B+C+D+E) [PY: 550 C] Peaks (A+B+C) [TD: 100-300 C] Peaks (D+E) [PY: 600 C] B: C: D: E: Qualitative and quantitative analysis based on data from varied sources including F-Search and other analytical techniques Page 4 Identification of volatiles (A, B, C): F-Search (EGA and additives) / NIST, Wiley library Identification of volatiles (D, E) originated from polymer: F-Search (polymer and pyrolyzates libraries) Identification of volatiles (A, B, C, D, E): user generated library Page 5

3030D Accessories for extended capability Micro-UV Irradiator (UV-1047Xe) Any polymeric material can be exposed to UV radiation, in any atmosphere, at temperature, for virtually any length of time. Volatiles formed during the irradiation are trapped and analyzed. Technical Notes: PYA5-003E, PYA5-001E F-Search Auto-Shot GC/MS Adapter (MS402180) The Vent-free adapter facilitates changing columns or the change over from EGA to the analytical mode without venting the MS. EGA/PY-3030D Carrier Gas Selector (CGS-1050Ex) Automatically switches between two different gases. Heat sample in air, separate using helium. Technical Notes: PYT-23E, 24E and PYA4-003. Selective Sampler (SS-1010E) Heart-cut individual EGA thermal zones. Each zone can be directed to the analytical column for analysis or automatically vented. Technical Notes: PYA-012E, 019E and 023E MicroJet Cryo-Trap (MJT-1035E) Vapors are trapped using LN₂. Special glass Tee reduces consumption of LN₂. Manual, automated, and stand-alone versions. Technical Note: PYT-019E Ultra ALLOY Metal Capillary Columns Available with a number of high temperature stationary phase, column lengths, film thickness and column inner diameters. Multi-layer deactivation treatment enhances thermal stability, inertness and durability. Technical Notes: UAT-002E, 003R and 004E Auto-Shot Sampler (AS-1020E) Up to 48 samples can be analyzed. When performing multiple analyses on a single sample, the sample is held at near-ambient temperature between analyses. The sample path has one isolation valve and two magnetic cup positioning valves which are always at ambient temperature. The automated analysis of multiple samples requiring different analytical modes can be analyzed in a single sequence. Evolved gas analysis (EGA), which is done with a tube rather than a separating column, requires a separate sequence table. guaranteed reproducibility page 6

3030D Accessories for extended capability F-Search Software (PY-1110E) F-Search is used to identify individual compounds and/or polymers using a patented search algorithm and specialized Frontier MS libraries. The libraries include GC as well as MS chromatograms. Each library can be edited. In addition, custom in-house libraries can be created. Four libraries are available: polymer, pyrolyzates, additives and EGA thermograms. The GC/MS data obtained with the instruments manufactured by Agilent Technologies, Shimadzu, and JEOL can be searched without modification. Data generated on GC/MS instruments manufactured by other companies can also be searched after converting the data file to a NetCDF (AIA). If your system includes the NIST/EPA/NIH mass spectral library (National Institute of Standards and Technology) and its search engine software, it can be accessed directly from within F-Search. F-Search Software Polymer Analysis EGA library (Thermogram: 268 polymers) PY-1112E Polymer library (Pyrogram: 268 polymers) PY-1113E Pyrolyzates library (with chemical structures) PY-1115E Additive Analysis Additive library (chromatogram: 358 additives) PY-1114E Technical Notes: PYA2-013E, 054E and PYA3-006, F-Search Product Bulletin. The partial results for a typical library search are illustrated below. Unknown polymer Unknown polymer Candidate No. 1: PE(HDPE) Candidate No. 1 Candidate No. 2: P(E-AA) Candidate No. 2 The average MS spectrum of the unknown along with the averaged spectrum of the two best matches are shown. A table showing match quality is presented. The pyrograms of the unknown and the two best matches are displayed for comparative purposes. guaranteed reproducibility page 7

Compatibility & Support The EGA/PY-3030D Multi-Shot Pyrolyzer is compatible with major manufacturer s GC or GC/MS systems. All Frontier channel partners receive periodic service training on all Frontier Lab products. This ensures that our customers receive quality support worldwide. Visit our website to view a number of support videos including maintenance and F-Search demonstration. www.frontier-lab.com Information subject to change without notice. 2013 Frontier Laboratories IW130301 Ver. 3.00