The art of elemental analysis
|
|
|
- Ira Bell
- 10 years ago
- Views:
Transcription
1 vario MACRO CUBE
2
3 The art of elemental analysis 100 years ago, in the center of Germany, near Frankfurt, the advanced technology company Heraeus developed and manufactured the world s first elemental analyzer for organic substances. From that foundation, a continuous progression of technology in elemental analysis products led to the establishment of Elementar. Still at the same location today, Elementar is the world s leading producer of instruments for the analysis of C, H, N, S and O. Elementar has utilized its century long experience to develop the next generation for multi element determination on macro sized samples. Consider these features: The only system for CHNS analysis in macro samples. Ability to analyze nearly all types of samples. No matrix dependency of the measurement. Highest precision and accuracy of the analytical results. Unsurpassed reliability and long time stability. Desing innovations which make the instrument easy to use and maintain. Lowest operating and maintenance costs due to robust design and hybrid technique. Elementar has coupled the latest developments in micro electronics and mechanics with their vast experience in elemental analysis. Newly developed separation technology has expanded the already impressive analytical range of the predecessor vario MACRO model. Newly refined detectors with expanded element capability are available for the vario MACRO cube. Even the form and color of the vario MACRO cube are new. The vario MACRO cube incorporates a century of experience in elemental analysis design technique with the very latest electronic flow and processing technology. The result is a system with range, accuracy and versatility heretofore unsurpassed. Heraeus Micro Analyzer
4
5 The instrument concept - simply right The samples are weighed in tin or silver vessels and loaded in the integrated 60 position carousel. In a fully automated process, the sample is transferred through the ball valve into the combustion tube. While in the ball valve, each sample is individually flushed with helium carrier gas (Heraeus patent) to remove atmospheric nitrogen, resulting in a zero blank sampling process. Catalytic combustion is carried out at a permanent temperature of up to 1200 C. Note that the furnace warranty is a full 10 years! Oxygen is injected via a lance directly at the hottest spot which results in optimum combustion of the combustion gases. A second furnace serves for complete post combustion in CHN/CN mode. This is followed by reduction of the combustion gases on hot copper (or tungsten for non sulfur modes) in the reduction tube. The formed analyte gases, N 2, CO 2, H 2 O and SO 2 remain in the He carrier gas stream. This multi-zone technique guarantees comple conversion even for very difficult to combust sample materials. The gas mixture is separated in its components via purge & trap chromatography, then is detected by a thermal conductivity detector (TCD), which utilizes well proven thermistors. The Elementar solid state thermistor TCDs are stable for years and are not damaged iven in the presence of high oxygen. The TCD has a very large dynamic range which allows for the sequential analysis of very high concentrations next to very low concentrations, without the need to change any range or manual setting. An electronic gas flow controller is positioned just before the detector and ensures absolutely stable pressure and flow conditions. This results in a stable instrument calibration over months or even years. A connected PC computes the element concentration from the detector signal, and the sample weight on the basis of stored calibration curves. He/Ar O 2 He/Ar Ref. Combustion Gas Separation Detection 5
6 Peak graphic - Sulfanilamide N (16.26%) TCD-Signal N (16.26%) C (41.85%) TCD-Signal CO 2 Tem [ C ] t [s] t [s] N (16.26%) C (41.85%) H (4.68%) TCD-Signal H 2 O Temp N (16.26%) C (41.85%) H (4.68%) S (18.62%) TCD-Signal SO 2 Tem [ C ] [ C ] t [s] t [s]
7 The perfect gas separation Purge&trap Chromatography with TCD: a dynamic combination Elemental analysis is based on the high temperature combustion and subsequent analysis of the combustion gases. The perfect separation of the analyte gases prior to the detection is crucial for the performance of the instrument. With the vario MACRO cube, Elementar uses a well proven technique to ensure the highest performance. The adsorption of combustion gases on three separation columns and subsequent controlled desorption allow for a very wide dynamic range. CO 2, H 2 O and SO 2 are sequentially adsorbed on specific columns. N 2 passes through all three columns and enters the TCD. After the detection of the N 2 peak, the CO 2 column is quickly heated. CO 2 is released to the TCD and detected. The H 2 O column is then heated and the desorbed gas is diverted directly to the TCD. Finally, the SO 2 column is heated and the gas, by-passing the other two columns, is quantified by the TCD. Each heating step takes place only after the subsequent peak has passed the detector, resulting in baseline resolution, even for samples with very large differences in relative concentration. This technique also results in automatic optimization of the time of analysis. The purge & trap chromatography approach enables large amounts of organic material, up to 150 mg carbon absolute, to be analyzed even when there are large concentration differences between the elements. Thus, the vario MACRO cube can analyze both micro and macro samples with excellent precision and accuracy. Problems that are typical for alternative methods (matrix dependency, peak overlapping and drift) are not issues for the vario MACRO cube. vario MACRO cube CN Continuous Flow Hybrid for economical operation - the robust and elegant solution! It is important for labs with a very high sample throughput to have the lowest possible cost per analysis. The Continuous Flow Hybrid (CF-Hybrid) option for the vario MACRO cube CN results in significant savings in operation reagents. With no moving parts, CF-Hybrid technology streams only a user defined percentage of the combustion gases to the reduction tube. The method is most precise for labs which run larger batches of samples with a similar matrix. 7
8 User Interface Instrument Software Audit Trail in accordance with 21 CFR Part 11 System Check
9 Good software - good instrument The cube instruments of Elementar set new standards as the first elemental analyzers in which all instrument functions are digitally controlled and monitored. This results in completely new possibilities for automatic operation and optimization as well as remote control and diagnosis over the internet. The basis for this is the use of the latest micro processors and electronic sensors for all gas flows and pressures. The vario MACRO cube s firmware (internal software of the analyzer) is stored on flash memories, which can be easily updated via PC or the internet. The critically important fast signal communication between components in the analyzer (such as the detector signal) is handled by the fail-safe CAN bus technology. A commercial PC or laptop serves as the user interface for control and evaluation. Our software runs under the Windows operating system and offers state of the art features and capabilities: Self-explanatory user navigation and content-sensitive help screens make printed manuals almost obsolete. Graphical leak checking with pictorial guides for each step are a new favorite feature of users. The system is designed for intuitive operation, but content sensitive help is just a click away. User friendliness is designed into the software at all levels. Instrument operators do not need special skills to take advantage of the instruments powerful capabilities. The software is designed in accordance with the strict requirements of 21 CFR Part 11 data safety. All Elementar instrument software is developed and maintained internally to ensure the highest quality and performance. almost unlimited storage capacity of analytical data, including graphics and statistics automatic optimization of instrument operating conditions monitoring of maintenance intervals integration into exisiting networks data transfer into LIMS data transfer to calculation programs like Excel 9
10 Carbon * Hydrogen * Nitrogen * Sulfur * Sulfanilamide ± ± ± ± mg Polyethylene ± ± ± ± mg Coal ± ± ± ± mg Oil 86.3 ± ± ± ± mg Tobacco ± ± ± ± mg Fertilizer 0.23 ± ± ± mg Flue ash 1.36 ± ± ± mg Fish meal ± ± mg Starch ± ± mg Wheat ± mg * Element concentration in [%], Standard deviation in [%]
11 The most flexible CHNS analyzer Today s best ensures we are ready for the future Elementar s elemental analyzers have a very long lifetime. Instrument requirements typically change over time as the laboratory s external requirements change. Due to intelligent modular design and a wide variety of options, the vario MACRO cube is ready for your needs today, as well as those of the future. The vario MACRO cube is the most flexible instrument available for the macro elemental analysis of CHNS (optionally O and Cl). The applications cover all organic and the majority of inorganic samples of solid or liquid form. The instrument s particular strength lies in its flexibility. Sample weights in the milligram range or in the macro range can be analyzed in the same instrument run. No other analyzer can match the vario MACRO cube with respect to detection limit, dynamic concentration range and the ability to handle the most difficult types of samples. An example for this versatility is the ability to analyze both organic samples up to a weight of 150 mg in the CHNS mode, as well as 1 gram of soil samples. Element concentrations of well below 50 ppm to 100% are detectable with the standard detector (TCD). For even lower detection limits, special detectors can be employed. As one example an IR photometer allows the detection of sulfur down to 10 ppm, e.g. in soil. The accuracy and precision of this detector relies on the vario MACRO cube s high dynamic range electronic amplification of the detector signal as well as extremely stable gas flow via the electronic mass flow controller. Thus, the entire range of applications - organic, pharmaceutical, petrochemical, industrial, fossil fuels, environmental and bio materials - can be readily analyzed by the vario MACRO cube. The vario MACRO cube is part of a family of Elementar macro scale instruments. Note that one member of this family, the vario MAX, is designed for difficult to handle inhomogeneous samples, and/or for very high sample weights. This is possible due to the high temperature digestion at a continuous high furnace temperature of up to 1200 C. Competitive analyzers have difficulty achieving complete combustion of samples which generate very large amounts of combustion gas. The vario MACRO cube uses oxygen jet-injection through a ceramic lance to completely combust this and other types of difficult samples. 11
12 Chlorine measurements: Conostan standard (1%) Chlorine: ± 0.01 % mg Coal Chlorine: ± % 6 25 mg Fuel surrogate Chlorine: ± 0.11 % Oxygen measurements TCD: Benzoic acid Oxygen: ± 0.03 % Oxygen measurements IR: Oil Oxygen: ± % Sulfur measurements IR: Soil Sulfur: ± % 6 55 mg 6 2 mg 6 7 mg mg
13 Adding value systematically Versatility makes him a winner In addition to the standard CHNS determination, easy add-on options provide the broadest application range for the elemental analysis: vario MACRO CN Continuous Flow Hybrid Option results in the lowest cost of analysis by greatly increasing the life of consumable reagents. This can be added as a kit, and allows the user to select only a portion of the combustion gases to go through the reduction tube and detector. Upgrade kits for oxygen determination using high temperature pyrolysis. Conversion to CO in the presence of carbon at high temperature. CO is measured with standard TCD, or with IR detection for lower detection limits. Sulfur measurement with IR photometer To achieve a sulfur detection limit of approx. 10 ppm. This can be used simultaneously with CHN determination by TCD. Accessory for chlorine analysis with absolutely new sensor detection of HCl in the combustion gas over a large concentration range (patent applied for). Accessories for special applications The measurement of total organic carbon (TOC) is possible with the TOC option. Inorganic carbon (TIC) in solids can be directly measured by means of the solitic attachment. Software for quality assurance Options are available for the safety of electronic data (21 CFR Part 11), analytical quality assurance (AQS) and instrument validation (IQ, OQ). vario Liquid Sampler - VLS is an automatic sampler which allows the efficient measurement of syringe injectable liquid samples. The VLS can be swapped out for the solid sampler in just a few minutes. 13
14 Specifications vario MACRO cube Analysis method: High temperature combustion or pyrolysis of the sample and conversion of the elements into gaseous products. Separation of the analysis gases by purge & trap chromatography at up to 3 specific columns and detection at TCD (IR or chemosensor optional). Operating modes: CHNS, CHN, CNS, CN, N, S as standard with TCD, depending on mode S with IR detection optional, O with TCD or IR detection optional, Cl with chemosensor detection optional. Digestion temperatures: adjustable up to 1200 C (by combustion of the tin vessels a temperature of approx C is temporarily reached). in accordance with the safety standards: in accordance with: CE-label, EN , EMV low voltage directives 73/23/EEC AOAC , AOAC , AOAC , AOAC , AOAC , ASBC, AACC, (for fertilizer, meat, meat products, cereals, oil seed, flour, feed), DIN (milk and dairy products), DIN/ISO (soil), LUFA, MEBAK (breweries), DIN (testing solid fuels - determination of the sulfur content, ASTM D , (CHN in coal and coke), ASTM (CHN in oil products and lubricants), ISO 15178:2000(E) Soil quality - determination of total sulfur in dry combustion Detection range*: C: mg (or 100%) O: 0-6 mg* N: mg (or 100%) Cl: 0-4 mg H: 0-15 mg (or 100%) S: 0-18 mg (or 100%) Detection limit*: CN with TCD: < 50 ppm (for 300 mg soil sample) S with IR: < 10 ppm (for 300 mg soil sample) Standard deviation*: < 0.2% rel. (100 mg glutamic acid) 14 * depending on sample kind, analysis mode and options
15 Specifications vario MACRO cube Calibration: Sample weight*: Analysis time*: Multi point calibration, regression linear to the 4th order, stable over months. up to 200 mg organic substance or up to 1.5 g soil sample. self-optimizing depending on element content and sample weight e. g. N 4-5 min (150 mg wheat) CHN 7-8 min (100 mg flue ash) CHNS min (40 mg sulfanilic acid)) Autosampler: 60 positions in a magazine as standard reloadable any time during operation 80 or 120 positions for smaller sample sizes optional manual or automatic injection of liquid or gaseous samples optional Gases: He: % purity 7 l/analysis O 2 : % purity 0.05 l/analysis Ar: alternative carrier gas Instrument control: Operation and control via PC under Windows ; All instrument functions are digitally controllable, the comprehensive operation software includes e.g. automatic leak test, extensive error diagnosis, monitoring of the maintenance cycles, sleep-/wake up function, statistical evaluation and almost unlimited memory capacity for analysis data incl. graphics. Integration in data networks like LIMS and the possibility of remote control and diagnosis via the internet. In full compliance with 21 CFR Part 11 (option). Electrical connections: 100/110/200/230 V, 50/60 Hz, 1,8 kw Dimensions: cm (W D H) approx. 65 kg * depending on sample kind, analysis mode and options 15
16 vario MACRO cube is the most flexible instrument for the macro elemental analysis of C, H, N, S and O and Cl. Number, combination and occurance of the analyzed elements as well as precision of their determination by using most modern technologies represent the most advanced state of instrumental analysis for application areas like: Chemistry and Pharmaceutics Fine chemicals, pharmaceuticals, catalysts, polymers, oil products, etc. Industrial quality control Rubber, fertilizers, building materials, dyestuffs, cosmetics, glue, etc. Agriculture and Environment Plants, soil, food, compost, sewage sludge, waste, etc. Fossile fuels and power generation Coal, coke, petrochemical products, residual waste Special applications Chlorine determination, oxygen determination, filter samples Elementar Analysensysteme GmbH mail: [email protected] phone: +49 (0) 6181/ Donaustr Hanau, Germany web: fax: +49 (0) 6181/
Nitrogen analysis is elementary
rapid N CUBE Nitrogen analysis is elementary Nitrogen is one of the building blocks for proteins and therefore our basis for life. The precise nitrogen analysis is of vital importance not only for the
MILESTONE H E L P I N G C H E M I S T S
MILESTONE H E L P I N G C H E M I S T S 8 good reasons to choose the Milestone DMA-80 1. No sample preparation The DMA-80 does not require any sample preparation or other wet chemistry prior the analysis.
DMA-1 Direct Mercury Analyzer
DMA-1 Direct Mercury Analyzer www.milestonesrl.com MILESTONE H E L P I N G C H E M I S T S 8 good reasons to choose the milestone DmA-1 1. no sample preparation 2. ease of use 3. lowest cost of analysis
FP628. Nitrogen / Protein Determination by Combustion. Rev 1-6/8/11
FP628 Nitrogen / Protein Determination by Combustion Rev 1-6/8/11 Presentation Outline LECO Background N Determination FP628 Theory of Operation Specifications Advantages Software Data LECO Background
Elemental analyzer multi EA 5000
Elemental analyzer multi EA 5000 Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena/Germany www.analytik-jena.com [email protected] 1/6 multi EA 5000 The multi EA 5000 is a powerful elemental analyzer
G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method
G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality
The Sievers 900 Series TOC Analyzers
GE Water & Process Technologies Analytical Instruments The Sievers 900 Series TOC Analyzers imagination at work Delivering Next-Generation Ease of Use, Productivity, and Reliability The Sievers* 900 Series
DMA-80 Direct Mercury Analyzer
DMA-80 Direct Mercury Analyzer Milestone Srl Milestone Srl 1 Introduction Mercury in the atmosphere can be from manmade sources (coal-fired power plants, municipal incinerators, industrial boilers) or
G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method
G4 ICARUS HF Simultaneous Determination of Carbon and Sulfur in Solids Innovation with Integrity Combustion Method High Performance Carbon & Sulfur Analyzer Combustion Method with High-Frequency Furnace
1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.
Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative
DSC Differential Scanning Calorimeter
DSC Differential Scanning Calorimeter Introduction The Differential Scanning Calorimetry (DSC) is the most popular thermal analysis technique to measure endothermic and exothermic transitions as a function
Highly efficient flue gas analyzer
Highly efficient flue gas analyzer testo 320 Just a few clicks away from a heating system diagnosis O 2 High-resolution colour graphic display Quick and easy menu structure Storage space for 500 measurement
MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments
MCP 100 MCP 150 Modular Compact Polarimeters ::: Superior Optical Instruments Your Promise Anton Paar's Solution You have always made sure that your optically active substances meet all quality standards.
DETERMINATION OF TOTAL CARBON, TOTAL ORGANIC CARBON AND INORGANIC CARBON IN SEDIMENTS
DETERMINATION OF TOTAL CARBON, TOTAL ORGANIC CARBON AND INORGANIC CARBON IN SEDIMENTS Bernie B. Bernard, Heather Bernard, and James M. Brooks TDI-Brooks International/B&B Laboratories Inc. College Station,
TRL-onlineTOC Monitor is designed for monitoring carbon content in
TRL-onlineTOC Online TOC Monitor TRL-onlineTOC Monitor is designed for monitoring carbon content in Industrial process water To control and monitor different processes where water is used for heating or
Appendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
23 The Thermal Conductivity Detector
23 The Thermal Conductivity Detector General Information TCD pneumatics Conditions that prevent the detector from operating Filament passivation Carrier, reference, and makeup gas Negative polarity Analyzing
When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.
Voyager Pro Analytical and Precision Balances When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task. Voyager Pro s Advanced Applications simplify even the
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
Thermo Scientific ConFlo IV Universal Interface
m a s s s p e c t r o m e t r y Thermo Scientific ConFlo IV Universal Interface The Universal Interface Part of Thermo Fisher Scientific ConFlo IV Universal Interface The Universal Interface The development
XFA 600 Thermal Diffusivity Thermal Conductivity
XFA 600 Thermal Diffusivity Thermal Conductivity Thermal Diffusivity, Thermal Conductivity Information of the thermo physical properties of materials and heat transfer optimization of final products is
Phoenix 8000. Apollo 9000. Laboratory TOC Analyzers and Services Designed To Meet Your Needs
Laboratory TOC Analyzers and Services Designed To Meet Your Needs Simple, Reliable and Dependable Instruments Low Cost of Operation Expert Service and Support Phoenix 8000 UV-Persulfate Oxidation Technology
Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward
Chemical Analysis Natural Gas Analyzer A Family of optimized GC Solutions think forward Gas Chromatography Bruker Natural Gas Analyzers Natural gas is bought and sold as a bulk commodity with price based
Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.
Halogen Free: What, Why and How Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc. We will discuss What are Halogens and how we interact with them. Why Halogens, within consumer
Bridging the analytical gap
Bridging the analytical gap Thermal analysis provides perfect tools for the characterization of all kinds of organic and inorganic solids or liquids. Thermodynamic transitions, thermal stability, decomposition
MILESTONE START D. Microwave Digestion System
MILESTONE H E L P I N G C H E M I S T S START D Microwave Digestion System The unique START D Milestone has been active for two decades in the field of microwave sample preparation and, with more than
Tracer Detection Systems
Tracer Detection Systems WASSON ECE Engineered Solutions, Guaranteed Results. Wasson-ECE Tracer Analysis System The industry standard for low level perfluoronated tracer analysis. Tracer tagging technology
Online Infrared Flue Gas Analyzer Gasboard 3000
Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume
Advanced Solutions for Gas Monitoring
Continuous Emissions Monitoring Stack Testing Process Monitoring Quality Control Engine Exhaust Gas Monitoring Workplace Air Quality Monitoring Combustion Research Emergency Rescue Services Advanced Solutions
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
Assessing the Changes Required by the Industrial Boiler MACT Regulations
Technical Paper MS-17 Assessing the Changes Required by the Industrial Boiler MACT Regulations Authors: A.L. LeClair L.M. McDermitt Babcock & Wilcox Power Generation Group, Inc. Barberton, Ohio, U.S.A
Assignment 8: Comparison of gasification, pyrolysis and combustion
AALTO UNIVERSITY SCHOOL OF CHEMICAL TECHNOLOGY KE-40.4120 Introduction to biorefineries and biofuels Assignment 8: Comparison of gasification, pyrolysis and combustion Aino Siirala 309141 Assignment submitted
DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech
E D 3 6 & E H D 3 6 DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech CONTENT 1 ENVIRONMENTAL... 5 1.1 SOIL... 5 1.2 WASTE WATER... 6 2 FOOD... 7 2.1 RICE... 7 2.2
Continuous flow direct water heating for potable hot water
Continuous flow direct water heating for potable hot water An independently produced White Paper for Rinnai UK 2013 www.rinnaiuk.com In the 35 years since direct hot water systems entered the UK commercial
Tutkimuksen merkitys menestyvässä liiketoiminnassa- Innovaatiosta tuotteeksi
Tutkimuksen merkitys menestyvässä liiketoiminnassa- Innovaatiosta tuotteeksi Matti Rautanen Manager, External Networks, Power-wide R&D Tutkimuksella tulevaisuuteen- seminaari Kaukolämpöpäivät, Kuopio 29.8.2013
Adsorption air dryers ADS 1 215
Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that
Pore size and BET surface area. analysis at your fingertips. SA 3100. Gas Adsorption Analyzer
Pore size and BET surface area analysis at your fingertips. SA 3100 Gas Adsorption Analyzer The History of Beckman Coulter Particle Characterization Introducing The SA 3100 Surface Area and Pore Size Analyzer
CHROMOCTANE O N LINE ANALYZER
GECIL Process GT instruments CHROMOCTANE O N LINE ANALYZER ASTM D6733 DHA and RON and MON on line GC for Reformer unit Automatic Chromatographic system for analysis of naphta feeds and reforming gasolines
ADU 5. Automatic Distillation Unit
ADU 5 Automatic Distillation Unit Atmospheric Distillation Distillation tests are used to characterize the volatility of petrochemical products. These volatility characteristics are a critical measurement
Kompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
FMA-80 Fluorescence Mercury Analyzer
FMA-8 Fluorescence Mercury Analyzer www.milestonesrl.com MILESTONE H E L P I N G C H E M I S T S The new Milestone FMA-8 The mercury problem A wide range of mercury analyzers Milestone offers a wide range
IB Chemistry. DP Chemistry Review
DP Chemistry Review Topic 1: Quantitative chemistry 1.1 The mole concept and Avogadro s constant Assessment statement Apply the mole concept to substances. Determine the number of particles and the amount
MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA
MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA n ABSTRACT Mercury is often present in natural gas, petrochemical and some
AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL
FUEL CONSUMPTION MEASUREMENT AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL Description The combination of AVL Fuel Mass Flow Meter and AVL Fuel Temperature Control is a high precise and continuous
MPA. Innovation with Integrity. Multi Purpose Analyzer FT-NIR
MPA Multi Purpose Analyzer Innovation with Integrity FT-NIR Discover the Flexibility of FT-NIR Spectroscopy The MPA is the result of almost 40 years of experience in the engineering and production of FT-IR
Amino Acid Analyzer L-8900
Amino Acid Analyzer L-8900 VWR - Hitachi Your Partner in Amino Acid Analysis Hitachi has manufactured more than 1800 Amino Acid Analysers for over 40 years. The new Amino Acid Analyser Model L-8900 is
Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants
Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants Version 2004-01 / August 2004 (HGRS-JW-04-25s) HGRS-CTS/MT J. Waltisberg SUMMARY ( ) shall not
Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja
Process gas chromatographs. Measurement made easy Compliance Solutions for 40CFR60 Subpart Ja Introduction ABB offers a proven analytical solution to completely meet your Refinery Flare Monitoring requirements
Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions
Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by
EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons
Agilent Cary 60 UV-Vis
Agilent Cary 60 UV-Vis Efficient. Accurate. Flexible. Specifications Introduction The Agilent Cary 60 UV-Vis spectrophotometer is efficient, accurate and flexible, and is designed to meet both current
QuickCODultra. Online COD for every kind of water. Especially for the rough stuff. Fast. Precise. Reliable. COD-ANALYSis
COD-ANALYSis Online COD for every kind of water. Especially for the rough stuff. Fast. Precise. Reliable. 2 Monitoring of all kinds of water especially For the rough stuff. LAR Process Analysers AG a measurement
Differential Scanning Calorimetry DSC
Analyzing & Testing Differential Scanning Calorimetry DSC Technique, Instrument, Applications DSC 3500 Sirius DSC 3500 Sirius Principle of Operation Differential Scanning Calorimetry Differential Scanning
Biogas as transportation fuel
Biogas as transportation fuel Summary Biogas is used as transportation fuel in a number of countries, but in Europe it has only reached a major breakthrough in Sweden. All of the biogas plants in Sweden
STANDARD CLEANING AND CALIBRATION PROCEDURE FOR TGA-50(H) AND TGA-51(H)
STANDARD CLEANING AND CALIBRATION PROCEDURE FOR TGA-50(H) AND TGA-51(H) by Joseph F. Greenbeck, Jr. And Courtney W. Taylor INTRODUCTION The following procedure is to be used for the maintenance and calibration
Plant components, selected for sound performance
Plant components, selected for sound performance Selected plant components to meet our customers demands We provide a wide range of plant components offering lowest cost of ownership, high product safety
HFM Heat Flow Meter Thermal Conductivity Analyzer
HFM Heat Flow Meter Thermal Conductivity Analyzer Introduction An insulating material is a material with low thermal conductivity, which in the construction industry, equipment manufacturing, or the production
On-line Dissolved Gas Analysis
On-line Dissolved Gas Analysis accord. to IEC 567/ASTM 3612 Online-Monitoring of transformers Automatic on-line analysis of 11 gases The analysis is done in 2 steps with high selectivity and accuracy fully
GC-xt. The most flexible GC /GC-MS liquid sample injector
GC-xt Prep and Load Platform The most flexible GC /GC-MS liquid sample injector Environmental Foods/Beverages Consumer Products Forensics Petrochemicals/Polymers Pharmaceuticals GC-xt Liquid mode Prep
7. 1.00 atm = 760 torr = 760 mm Hg = 101.325 kpa = 14.70 psi. = 0.446 atm. = 0.993 atm. = 107 kpa 760 torr 1 atm 760 mm Hg = 790.
CHATER 3. The atmosphere is a homogeneous mixture (a solution) of gases.. Solids and liquids have essentially fixed volumes and are not able to be compressed easily. have volumes that depend on their conditions,
Transformer Oil Gas Analysis
Get on the Analyzer FAST TRACK Transformer Oil Gas Analysis Helping customers protect the environment! 1 Why Analyzers Value to Customers Alleviates Resource Pressure Facilitates Configuration Use Advanced
DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors
DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors Faster response higher accuracy greater stability longer life. Dräger electrochemical sensors offer all these benefits. The robust
Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible
Multi-Shot Pyrolyzer EGA/PY-3030D Flexible Versatile Reproducible Why Evolved Gas Analysis? Why Pyrolysis? Today, analytical pyrolysis encompasses much more than simple flash pyrolysis of polymeric materials.
How To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
Introducing AUDIT-BUDDY
Introducing AUDIT-BUDDY Optimize the Data Center with AUDIT-BUDDY Executive Summary Proper temperature and humidity for the inlet air into the servers is essential to efficient data center operation. Several
ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS
1 ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS Buck Scientific Atomic Absorption Spectrophotometer, Model 200 Atomic absorption spectroscopy (AAS) has for many years
Dissolved and precipitated oxalate
Accepted 2005 Process liquors from bleach plants Dissolved and precipitated oxalate Using Ion Chromatography 0 Introduction In bleach plants of pulp mills with a high degree of system closure, there is
CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA 91342 ABSTRACT
CRYOCOOLER CONTAMINATION STUDY S.W.K. Yuan, D.T.Kuo, and A.S. Loc EI Technologies, Cryocooler Group Sylmar, CA 91342 ASTRACT Eliminating or reduction of contamination is essential for the success of cryocoolers
LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS WWW.LANCOM4.COM
PORTABLE FLUE GAS MONITORING WWW.LANCOM4.COM i CO low CO high O 2 NO NO2 NOx CO2 H2S SO2 CxHy QUALITY CUSTOMER SOLUTIONS AMETEK LAND HAS BEEN BUILDING PRECISION MEASURING EQUIPMENT SINCE 1947. WE ARE SPECIALISTS
12:10 Lysotherm : 5 jaar ervaring met innovatieve slibhydrolyse. Bert Geraats (Eliquo)
LYSOTHERM A novel approach to thermal sludge hydrolysis 01.07.2015 ELIQUO WATER GROUP FACTS AND FIGURES STAFF HISTORY FIGURES >200 employees Engineers Technicians Sales, commercial staff 1986 ELIQUO WATER
AC Service Equipment ACE 21 EXPERT. Fully automatic service station. R-1234yf refrigerant. Made in Germany
AC Service Equipment ACE 21 EXPERT Fully automatic service station R-1234yf refrigerant Made in Germany The new generation of air conditioning service equipment: Robust. Environment-friendly. Fully automatic.
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
SWISS MADE. Moisture Analyzers. PREMIUM AND MASTER Series 330 XM
SWISS MADE Moisture Analyzers PREMIUM AND MASTER Series 330 XM High Resolution Precision PREMIUM AND MASTER Series 330 XM Moisture Analyzers from Precisa - for efficient measurements and accurate results.
SCION SQ Series GC-MS
SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative
How To Use An Irius Pid Detector
SIRIUS PID & 4-Gas Detector [ Compact and Versatile for all your needs] SIRIUS [ Maximum versatility in one hand] The new SIRIUS PID Detector combines incredible performance, versatility and ease of use
MOISTURE (Karl Fischer, Buffered)
MOIST.03-1 MOISTURE (Karl Fischer, Buffered) PRINCIPLE SCOPE The sample is dissolved in a mixture of methanol and formamide (50:50 v/v) and then titrated with standardized Karl Fischer reagent. The titration
Introduction to Waste Treatment Technologies. Contents. Household waste
Contents Introduction to waste treatment technologies 3 Section 1: The treatment of recyclable waste 4 Bulking facilities 5 Materials Reclamation Facility (MRF) 6 Reuse and recycling centres 8 Composting
Certificate: 0000038506 / 20 August 2013
Test report: 936/21219899/B of 28 March 2013 Initial certification: 23 July 2013 Expiry date: 22 July 2018 Publication: BAnz AT 23 July 2013 B4, chapter II, No. 1.1 Approved application The tested AMS
The Ambient Air Monitoring System
The Ambient Air Monitoring System 1.0 Introduction: The Ambient Air Monitoring System (AAMS) can measure a range of toxic and flammable gases, particulate matter, meteorological and environmental parameters
CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2
WASTE HEAT BOILERS CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF WASTE HEAT BOILERS... 4 2.1 Complex Solution...4 2.2 Kind of Heat Exchange...5 2.3 Heat Recovery Units and Their Usage...5 2.4 Materials
Table of content. L81/RITA high speed Thermo Balance. Quattro Dilatometer. L75/1250/B/S Macro Dilatometer. New air cooled furnace program
THERMAL TRENDS 2 Table of content L75/SDC simultaneous-dilatometer/calorimeter L75/SDD simultaneous Dilatometer/DTA L81/RITA high speed Thermo Balance Quattro Dilatometer L75/1250/B/S Macro Dilatometer
Process Instrumentation
Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Process Gas Chromatography Features of Process Chromatographs Agilent 7890A
aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS
aurora ICP-MS The Science of Sensitivity Innovation with Integrity ICP-MS Powers the Business of Quantification aurora ICP-MS enhanced value package Bruker s ICP-MS is famous for its innovative and unique
BTU ANALYSIS USING A GAS CHROMATOGRAPH
BTU ANALYSIS USING A GAS CHROMATOGRAPH By Joseph E. Landes Southern Petroleum Laboratories, Inc. Technical Director Hydrocarbon and Field Services 8820 Interchange Drive Houston, Texas 77054 Introduction
= 1.038 atm. 760 mm Hg. = 0.989 atm. d. 767 torr = 767 mm Hg. = 1.01 atm
Chapter 13 Gases 1. Solids and liquids have essentially fixed volumes and are not able to be compressed easily. Gases have volumes that depend on their conditions, and can be compressed or expanded by
AMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
ß-CYCLODEXTRIN SYNONYMS
ß-CYCLODEXTRIN Prepared at the 44th JECFA (1995), published in FNP 52 Add 3 (1995) superseding specifications prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications
Top Technology for Industry, Agriculture, Business and Communities
Top Technology for Industry, Agriculture, Business and Communities CHP The Technology with a Potential for Saving Energy Combined Heat and Power (CHP) is a highly efficient technology for the conversion
1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;
1/11 CO2 DOSAGE SYSTEMS CO2 dosage system consists of following parts; 1 - O2 trim system with micro processing burner (automatic combustion monitoring), 2 - Other components of O2 trim system, 3 - CO2
DGA - Method in the Past and for the Future
DGA - Method in the Past and for the Future Page 2 May 2012 1970 1973 Doerenburg introduced the differentiation between electrical and thermal failure mode and introduced ratios for fault gases with similar
Chromatograph Maintenance and Troubleshooting Class # 5050
Chromatograph Maintenance and Troubleshooting Class # 5050 Shane Hale Business Development Manager Emerson Process Management Gas Chromatographs Division 5650 Brittmoore Drive Houston, TX 77041 USA Introduction
NEW SMART STEAM DISTILLATION VAPODEST 200 VOLATILES SO 2 ALCOHOL PHENOLS KJELDAHL-N UNRIVALED EASE OF USE EFFICIENCY FUNCTIONS SAFETY
NEW VAPODEST 200 SMART STEAM DISTILLATION VOLATILES SO 2 ALCOHOL PHENOLS KJELDAHL-N C. Gerhardt proudly presents the brand new development of the successful VAPODEST line. Additional functions increase
Ecological Aspects of Oil Shale Processing
Abstract Ecological Aspects of Oil Shale Processing Y. Zhirjakov, Institute of Oil Shale Research Tallinn Technical University Tallinn, Estonia 26 th Oil Shale Symposium Oil shale belongs to lean and environmentally
THE PRACTICAL, PROVEN PATH TO GREEN ENERGY. RTP rapid thermal processing from Envergent Technologies
THE PRACTICAL, PROVEN PATH TO GREEN ENERGY. RTP rapid thermal processing from Envergent Technologies RTP CONVERTS BIOMASS TO PYROLYSIS OIL FAST. Less than two seconds. That s all the time it takes to convert
Thermal Conductivity Detector
Thermal Conductivity Detector Troubleshooting Tips The thermal conductivity detector (TCD) detects the difference in thermal conductivity between column effluent flow (carrier gas + sample components)
Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate
Cantaurus, Vol. 7, 5-8, May 1999 McPherson College Division of Science and Technology Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Janet Bowen ABSTRACT Sulfate is used in
Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer
Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer Hideki Nagano*, Kunio Miyazawa**, Yoshinori Yomura***, Toshihiko Iwasaki****, Takashi Yokoyama***** and
GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE
ACTA CHROMATOGRAPHICA, NO. 13, 2003 GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE A. Pavlova and R. Ivanova Refining and Petrochemistry Institute, Analytical Department, Lukoil-Neftochim-Bourgas
Standard methods in water analysis
Branch General analytical laboratories; water analysis Keywords Water analysis; standard methods; ASTM; DIN; ISO; USP; EPA; SLMB; EN; SCA; titration; ion chromatography; voltammetry; branch 1; branch 2
M I C R O W A V E O P E N V E S S E L D I G E S T I O N S Y S T E M T HE NEW MIL E STO NE MILESTONE
M I C R O W A V E O P E N V E S S E L D I G E S T I O N S Y S T E M T HE NEW MIL E STO NE MILESTONE WHY THE START MOD The need for larger sample sizes Acid digestion of organic samples produces gaseous