Recovering from a Hard Drive Failure



Similar documents
Cisco Physical Security Multiservices Platform Series User Guide

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

RAID1 rebuild procedure for Intel Matrix Storage Manager

This user guide describes features that are common to most models. Some features may not be available on your computer.

Dell DR4000 Disk Backup System. Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

MAP/100P RAID System Recovery. MAP/100P RAID System Recovery - 1

How To Use A Raid

Rebuilding a Show Store RAID with the original drives

Resilient NAS by Design. Buffalo. A deployment guide to disaster recovery. Page 1


HP MediaSmart Server Software Upgrade from v.2 to v.3

HP StoreVirtual 4630 Storage Maintenance Guide

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version PROMISE Technology, Inc. All Rights Reserved.

Ultra ATA 133 RAID PCI Pro

DF to-2 SATA II RAID Box

RAID Utility for Windows

Marvell SATA3 RAID Installation Guide

Configuring ThinkServer RAID 100 on the TS140 and TS440

Storage node capacity in RAID0 is equal to the sum total capacity of all disks in the storage node.

FUSION R400 RAID USB 3.0

RAID 1(+0): breaking mirrors and rebuilding drives

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

Packard Bell Easy Repair 1. Packard Bell Easy Repair

MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement

1. System Requirements

Using GIGABYTE Notebook for the First Time

HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD A February 2007

Your Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)

Managing Storage Using RAID

NVIDIA RAID Installation Guide

XL-RAID-SATA2-USB. User Manual. v.1.2 (January, 2010)

PA-5000 Series SSD Storage Options Configuring RAID and Disk Backup

McAfee Firewall Enterprise

User Manual. For more information visit

2» 10» 18» 26» PD »

Hydra Super-S Combo. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 29, v1.3

Intel Matrix Storage Manager 8.x

Configuring ThinkServer RAID 100 on the Lenovo TS130

Network Attached Storage System Recovery Procedure

Using GIGABYTE Notebook for the First Time

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

VAIO Computer Recovery Options Guide

Intel Rapid Storage Technology

VT8237 SATA RAID User Manual

Using GIGABYTE Notebook for the First Time

Tyan Computer. Transport PX22. Service Engineer s Manual

HDD Troubleshooting. This manual is intended for professional installers not for end users. Please handle this information with care.

Windows 8 Backup, Restore & Recovery By John Allen

Guide to SATA Hard Disks Installation and RAID Configuration

LSI Software RAID Configuration Utility

Backing Up and Restoring Software

Promise FastTrak 100-Lite RAID Controller

How To Set Up A Hard Disk Drive With A Rkd (Sr5650) And A Hard Drive (Srs5650-Wbs1/Sb2)

Network Storage System with 2 Bays

RAID EzAssist Configuration Utility Quick Configuration Guide

TeamPoS 2000 Installation Instructions Upgrade to M Motherboard

4 Backing Up and Restoring System Software

Cisco FlexFlash: Use and Manage Cisco Flexible Flash Internal SD Card for Cisco UCS C-Series Standalone Rack Servers

Highly Reliable Systems. FirstRAID DXR TM. Documentation Supplement V1.1. Copyright 2007 by Highly Reliable Systems. All Rights Reserved.

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

Using GIGABYTE Notebook for the First Time

is605 Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives FW400 + FW800 + USB2.0 Combo External RAID 0, 1 Subsystem User Manual

RAID installation guide for ITE8212F

ITE RAID Controller USER MANUAL

HP MediaSmart Server Software Upgrade from v.1 to v.3

Managing RAID. RAID Options

VIA / JMicron RAID Installation Guide

This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.

Cserver 1180 / Basic Operating Manual

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

How To Set Up A Hard Drive With A Harddrive With A 2Gb Hard Drive (I386) And 2Gb Drive (Amd64) On A Hardrive (I219) (Iee) (Amd66) (Ai219

Xserve G5 Using the Hardware RAID PCI Card Instructions for using the software provided with the Hardware RAID PCI Card

BounceBack Server Solution Reference Guide

10 Backing Up Windows 7

External Storage 200 Series. User s Manual

How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The

McAfee Data Loss Prevention

Guide to SATA Hard Disks Installation and RAID Configuration

MANAGING DISK STORAGE

Open Source and License Source Information

Quick Start Guide. RV 120W Wireless-N VPN Firewall. Cisco Small Business

RAID configuration and driver installation guide

Wash Select II to WashPay Integration Field Retrofit Installation Guide

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

RAID installation guide for Silicon Image SiI3114

How to Set Up Your NSM4000 Appliance

RAID 1(+0): breaking mirrors and rebuilding drives

Hydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, v1.0

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

This user guide describes features that are common to most models. Some features may not be available on your computer.

Cloning Utility for VersaView Industrial Computers

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

Quick Start Guide. RV0xx Series Routers

Version : 1.0. SR3620-2S-SB2 User Manual. SOHORAID Series

Transcription:

APPENDIXB This appendix describes how to recover from a hard drive failure on a Multiservices Platform Series device. The process for doing so depends on the physical security product that you are using and the number of hard drives that are in your Multiservices Platform Series device. A hard drive that fails on a Multiservices Platform Series device displays a lit red LED on the front panel of its bay. If a hard drive fails, see Table B-1 (for 1-RU models) or Table Table B-2 (for 2-RU models), locate your physical security application and hard drive configuration, then follow the steps in the Recovering column. When replacing a hard drive, be aware of these guidelines: A system with RAID-1 or RAID-5 hard drives is fault-tolerant. In these systems, data is preserved if only one drive fails, and you can hot swap a failed hard drive. After hot swapping a drive, it is not necessary to reboot or reimage the system. The system becomes fully operational following drive replacement and after the RAID set goes through an automatic rebuild process. The rebuild process can take several days. If another drive fails before the rebuild process completes, all system data and configuration is lost and the system must be reimaged. A system with RAID-6 hard drives is fault-tolerant and data is preserved in the following cases: One hard drive fails Two hard drives fail at the same time One hard drive files, then another hard drive fails after the first one has been replaced and while it is rebuilding. You can hot swap one or two failed hard drives. After hot swapping drives, it is not necessary to reboot or reimage the system. The system becomes fully operational following drive replacement and after the RAID set goes through an automatic rebuild process. The rebuild process can take several days. If you hot swap two drives and a third drive fails before the rebuild process completes, all system data and configuration is lost and the system must be reimaged. In systems with JBOD-type/RAID-0 hard drives, all data on a hard drive is lost if the drive fails. In this case, you must reimage the system after replacing the drive. B-1

Appendix B Table B-1 Physical Security Application Cisco VSM 1 Cisco IPICS 2 Cisco PAM 3 Hard Drive Recovery for Cisco Physical Security Products on a Multiservices Platform Series 1_RU Model Hard Drive Configuration Notes Recovering 1 hard drive (JBOD-type/ RAID-0) 4 hard drives (RAID-5) 2 hard drives (RAID-1) 1 hard drive (JBOD-type/ RAID-0) Provides a single storage repository Not fault tolerant; if a drive fails, you cannot access the system Provides an operating system and a single media repository striped across all drives Fault tolerant; if a single drive fails, the system functions in degraded mode Drive hot-swapping is supported if a single drive fails If an additional drive fails before the first drive is replaced and the RAID set rebuilds, data is lost and the system fails Mirrored configuration; one drive can fail without loss of data Fault tolerant; if a single drive fails, the system functions in degraded mode If the second drive fails before the first drive is replaced and the RAID set rebuilds, data is lost and the system fails Not fault tolerant; if a drive fails, you cannot access the system Replace the failed drive as described in the Replacing a Hard Drive section on page B-3. Then, Reimage the server as described in the Reimaging a Multiservices Platform Series Device that is Running VSM section on page B-5. If one drive fails, replace the failed drive as described in the Replacing a Hard Drive section on page B-3. If multiple drives fail, replace each failed drive as described in the Replacing a Hard Drive section on page B-3. Then, reimage the system as described in the Reimaging a Multiservices Platform Series Device that is Running VSM section on page B-5. If one drive fails, replace the failed drive as described in the Replacing a Hard Drive section on page B-3. If multiple drives fail, replace each failed drive as described in the Replacing a Hard Drive section on page B-3. Then, reimage the system as described in the Reimaging a Multiservices Platform Series Device that is Running Cisco IPICS section on page B-6. Replace the failed drive as described in the Replacing a Hard Drive section on page B-3.Then, reimage the system as described in the Reimaging a Multiservices Platform Series Device that is Running Cisco PAM section on page B-7. 1. Cisco VSM = Cisco Video Surveillance Manager 2. Cisco IPICS = Cisco Interoperability and Collaboration System 3. Cisco PAM = Cisco Physical Access Manager B-2

Appendix B Replacing a Hard Drive Table B-2 Physical Security Application Cisco VSM Cisco IPICS Hard Drive Recovery for Cisco Physical Security Products on a Multiservices Platform Series 2_RU Model Hard Drive Configuration Notes Recovering 6 or 12 hard drives (RAID-6) 6 hard drives (RAID-5) Provides an operating system and a single media repository striped across all drives Fault tolerant; if one or two drives fail, the system functions in degraded mode Drive hot-swapping is supported if one or two drives fail If a third drive fails before the first and second drives are replaced and the RAID set rebuilds, data is lost and the system fails Fault tolerant; if a single drive fails, the system functions in degraded mode Drive hot-swapping is supported if a single drive fails If an additional drive fails before the first drive is replaced and the RAID set rebuilds, data is lost and the system fails If one or two drives fail, replace the failed drive as described in the Replacing a Hard Drive section on page B-3. If three or more drives fail, replace each failed drive as described in the Replacing a Hard Drive section on page B-3. Then, reimage the system as described in the Reimaging a Multiservices Platform Series Device that is Running VSM section on page B-5. If one drive fails, replace the failed drive as described in the Replacing a Hard Drive section on page B-3. If multiple drives fail, replace each failed drive as described in the Replacing a Hard Drive section on page B-3. Then, reimage the system as described in the Reimaging a Multiservices Platform Series Device that is Running Cisco IPICS, page B-6. Replacing a Hard Drive To replace a hard drive Multiservices Platform Series device, perform the following steps. In a server with RAID-1 or with RAID-5 and one failed drive, you can hot swap the failed drive. Hot swapping means that you replace a hard drive while the server is running. Use only Cisco approved hard drives in a Multiservices Platform Series device. Procedure Step 1 Step 2 Take these actions to remove the hard drive from the chassis: a. Press the release catch on the drive bay. The drive bay handle extends. b. Use the drive bay handle to pull the drive out of the chassis. To remove a hard drive from a hard drive bay, see Figure B-1 and take the actions that follow. B-3

Replacing a Hard Drive Appendix B Figure B-1 Hard Drive and Hard Drive Bay 1 Drive bay 2 Hard drive 3 Hard drive retaining screws 4 Flat, stable surface Step 3 Step 4 a. Place the hard drive bay on a flat, stable surface such as a desk, table, or workbench. b. Remove the drive retaining screws and slide the hard drive away from the hard drive bay. To put a new hard drive into a hard drive bay, see Figure B-1 and take these actions: a. Place the hard drive bay on a flat, stable surface such as a desk, table, or workbench. b. Slide the hard drive into the hard drive bay. The printed circuit board side of the hard drive must face down. c. Align the mounting holes of the hard drive bay with the hard drive. Make sure that the bottom of the hard drive and the bottom of the hard drive bay are flush. d. Secure the hard drive retaining screws. Replace the hard drive bay in the chassis by pushing it into the chassis and pressing the drive bay handle to lock it in place. B-4

Appendix B Reimaging a Multiservices Platform Series Device that is Running VSM Reimaging a Multiservices Platform Series Device that is Running VSM Reimaging a Multiservices Platform Series Device that is Running VSM involves reconfiguring RAID to make replacement hard drives visible to the server and resetting the server to the factory defaults. Before reimaging a system, replace all failed hard drives. Caution This procedure is intended to recover a server from a catastrophic failure. Before you perform these steps, see Table B-1 to make sure that this procedure is appropriate for your situation. To reimage a server, perform the following steps: Procedure Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 Step 13 Step 14 Step 15 After replacing failed drives as described in the Replacing a Hard Drive section on page B-3, reboot the server and, as soon as the server starts booting, press Ctrl-M to access the RAID configuration tool. Choose Configure and press Enter. Choose New Configuration and press Enter. Choose Yes and press Enter to display the ports and drives. Choose Port 0 and press Spacebar to convert to ONLIN A00-00. Press F10 to configure. Press Spacebar to choose SPAN-1. Press F10 to continue. Specify the following settings: RAID = 0 Size = 12288 Choose Accept and press Enter to create VD0. Choose Accept and press Enter to create VD1. Press Esc to leave configuration mode and Yes to save the configuration. Press Esc again. For each additional drive: a. Select the next port and press Spacebar to change to ONLIN A0N-00, where N is the next drive. b. Press F10 to configure. c. Press Spacebar to choose SPAN-1. d. Press F10 to continue. e. Specify RAID = 0. f. Choose Accept and press Enter. g. Press Esc to leave configuration mode and Yes to save the configuration. h. Press Esc again. Press Esc to return to the Management menu. B-5

Reimaging a Multiservices Platform Series Device that is Running Cisco IPICS Appendix B Step 16 Step 17 Step 18 Press Esc to exit and Yes to confirm. Insert the recovery disc for your release of VSM and press Ctrl-Alt-Del to reboot. At the boot prompt, enter factory and press Enter. The operating system and VSM software installs. This process takes approximately 20 minutes. Progress messages provide information about the installation. When the process completes, the disk ejects, and a login screen appears. Reimaging a Multiservices Platform Series Device that is Running Cisco IPICS Reimaging a Multiservices Platform Series Device that is running Cisco IPICS involves reconfiguring RAID to make replacement hard drives visible to a server and resetting the server to the factory defaults. Before reimaging a system, replace all failed hard drives. Caution This procedure is intended to recover a server from a catastrophic failure. Before you perform these steps, see Table B-1 or Table B-2 to make sure that this procedure is appropriate for your situation. To reimage a server, perform the following steps: Procedure Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 Step 13 Step 14 After replacing failed drives as described in the Replacing a Hard Drive section on page B-3, reboot the server and, as soon as the server starts booting, press Ctrl-M to access the RAID configuration tool. Choose Configure and press Enter. Choose New Configuration and press Enter. Choose Yes and press Enter to display the ports and drives. Choose Port 0 and press Spacebar to convert to ONLIN A00-00. Press F10 to configure. Press Spacebar to choose SPAN-1. Press F10 to continue. Specify the following settings: RAID = 0 Size = 12288 Choose Accept and press Enter to create VD0. Choose Accept and press Enter to create VD1. Press Esc to leave configuration mode and Yes to save the configuration. Press Esc again. For each additional drive: a. Select the next port and press Spacebar to change to ONLIN A0N-00, where N is the next drive. B-6

Appendix B Reimaging a Multiservices Platform Series Device that is Running Cisco PAM Step 15 Step 16 Step 17 b. Press F10 to configure. c. Press Spacebar to choose SPAN-1. d. Press F10 to continue. e. Specify RAID = 0. f. Choose Accept and press Enter. g. Press Esc to leave configuration mode and Yes to save the configuration. h. Press Esc again. Press Esc to return to the Management menu. Press Esc to exit and Yes to confirm. Insert the operating system disc for your release of Cisco IPICS and press Ctrl-Alt-Del to reboot Note If you are using the 1-RU Multiservices Platform Series model, you need to attach a USB DVD drive. When the system reboots, the operating system installation process begins. See Cisco IPICS Server Installation and Upgrade Guide Release for your release of Cisco IPICS for detailed information about installing the operating system. Reimaging a Multiservices Platform Series Device that is Running Cisco PAM Reimaging a Multiservices Platform Series Device that is running Cisco PAM involves reconfiguring RAID to make replacement hard drives visible to a server and resetting the server to the factory defaults. Before reimaging a server, replace the failed hard drive. To reimage a server, see the Reinstalling the Cisco PAM Server Software from a Recovery CD section in Cisco Physical Access Manager User Guide for your release of Cisco PAM. B-7

Reimaging a Multiservices Platform Series Device that is Running Cisco PAM Appendix B B-8