LightCycler 480 Real-Time PCR System



Similar documents
Technical Note. Roche Applied Science. No. LC 18/2004. Assay Formats for Use in Real-Time PCR

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

Introduction To Real Time Quantitative PCR (qpcr)

Fluorescent dyes for use with the

amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye

QuantStudio 12K Flex Real-Time PCR System. The all-in-one qpcr instrument

Real-Time PCR Vs. Traditional PCR

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Eco TM 48 Real Time PCR System. Fastest block-based qpcr. Four colour multiplexing. Supports all chemistries. Fast cycling protocols

Essentials of Real Time PCR. About Sequence Detection Chemistries

Quantitative PCR Systems

2.500 Threshold e Threshold. Exponential phase. Cycle Number

RealStar HBV PCR Kit /2012

Real-time PCR: Understanding C t

SEQUENCING. From Sample to Sequence-Ready

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Real-time qpcr Assay Design Software

CFX96 Real-Time PCR Detection System. Real-Time PCR: CFX96 System

Highly specific and sensitive quantitation

The Power of Next-Generation Sequencing in Your Hands On the Path towards Diagnostics

Quando si parla di PCR quantitativa si intende:

DNA Integrity Number (DIN) For the Assessment of Genomic DNA Samples in Real-Time Quantitative PCR (qpcr) Experiments

Application Note. Single Cell PCR Preparation

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene. genesig Advanced Kit. DNA testing

Epstein Barr Virus (Human Herpes virus 4) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

LightCycler 480 Real-Time PCR System. High Resolution Melting: Optimization Strategies. Technical Note No. 1

Application Guide... 2

Human Herpes Virus 4 (Epstein Barr)

GloMax Discover and Explorer. State-of-the-art multimode readers for luminescence, fluorescence and absorbance detection.

TaqMan Fast Advanced Master Mix. Protocol

Human Herpes Virus 1 (Herpes simplex type 1) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

SYBR Green Realtime PCR Master Mix -Plus-

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

A guide to the analysis of KASP genotyping data using cluster plots

Absolute Quantification Getting Started Guide

Fluorescent Array Imaging Reader

Co Extra (GM and non GM supply chains: Their CO EXistence and TRAceability) Outcomes of Co Extra

HISTO SPOT SSO System

Evalution the multiplexed analysis of biomarkers made fast and simple by MyCartis

Your Personal Pipetting Robot

HBV Quantitative Real Time PCR Kit

Single-Cell Whole Genome Sequencing on the C1 System: a Performance Evaluation

As versatile as your requirements. 384 well. 96 well combi 48 well in situ

StepOne and StepOnePlus Real-Time PCR Systems

Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR

Mir-X mirna First-Strand Synthesis Kit User Manual

QPCR Applications using Stratagene s Mx Real-Time PCR Platform

Plexor Systems Instrument Setup and Data Analysis for the Applied Biosystems 7300 and 7500 Real-Time PCR Systems

Dengue Virus subtypes 1,2 3 and 4. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... 3 Untranslated Region (3 UTR) 150 tests

Scott Reierstad. Field Applications Scientist

Plexor Systems Instrument Setup and Data Analysis for the Roche LightCycler 2.0 and LightCycler 1.5 Systems using LightCycler Software Version 4.

Path-ID Multiplex One-Step RT-PCR Kit

Discover Your Potential

Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual

Hidex Sense. Hidex Triathler Multi-technology Microplate Reader. Hidex AMG. Consumables. Hidex 300 SL.

Thermo Scientific NanoDrop Products. Revolutionary technology. Elegant simplicity. Instruments for microvolume analysis of biomolecules

Accurate and sensitive mutation detection and quantitation using TaqMan Mutation Detection Assays for disease research

SeqScape Software Version 2.5 Comprehensive Analysis Solution for Resequencing Applications

FluorChem Q. A Quantitative Western Blot Imaging Solution

Factors Influencing Multiplex Real-Time PCR

Stratagene QPCR Mouse Reference Total RNA

Introduction to Quantitative PCR

Multiplex your most important

The AB7900Fast and Principles of Real Time PCR

Automation in genomics High-throughput management of biological samples and nucleic acids. Valentina Gualdi Operational Scientist PGP

QuantStudio 3D AnalysisSuite Software

Quantification of Propionibacterium acnes. Standard kit 150 tests

KASP genotyping chemistry User guide and manual

Idaho Technology Food Security Systems. System Components. Idaho Technology. Food Security and Pathogen Detection

Meso Scale Discovery. WINDOWS is a registered trademark of Microsoft Corporation

Methods and Application Guide. Introduction to Quantitative PCR

Optimizing Performance of the Transcreener ADP Assay for the BioTek Synergy 2 and 4 Multi-Mode Microplate Readers

Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial

Real-time PCR handbook

Speed Matters - Fast ways from template to result

Hepatitis B Virus. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... Core Protein Region. 150 tests.

GenScript BloodReady TM Multiplex PCR System

Beginner s Guide to Real-Time PCR

Quantification of Mycobacterium Tuberculosis. 150 tests

Fast PCR: General Considerations for Minimizing Run Times and Maximizing Throughput

HISTO SPOT SSO System. The most convenient automated HLA typing system. BAG Health Care the experts for HLA and blood group diagnostics

Discover Your Potential

Methylation Analysis Using Methylation-Sensitive HRM and DNA Sequencing

Single-Cell DNA Sequencing with the C 1. Single-Cell Auto Prep System. Reveal hidden populations and genetic diversity within complex samples

Cytell Cell Imaging System

amplification tech A Practical Guide to High Resolution Melt Analysis Genotyping

REAL TIME PCR USING SYBR GREEN

Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr

Relative Quantification of mirna Target mrnas by Real-Time qpcr. 1 Introduction. Gene Expression Application Note No. 4

Lyme Disease RecA gene. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere tests. Primerdesign Ltd.

PATHOGEN DETECTION SYSTEMS BY REAL TIME PCR. Results Interpretation Guide

StepOne and StepOnePlus Real-Time PCR Systems. Remarkably Simple Systems. Simply Remarkable Results.

BacReady TM Multiplex PCR System

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476

Amplification: Thermal Cyclers. Bio-Rad Thermal Cyclers

GENOTYPING ASSAYS AT ZIRC

QuantStudio 6 and 7 Flex Real-Time PCR Systems

DNA Sequence Analysis

Transcription:

Roche Applied Science LightCycler 480 Real-Time PCR System Planned introduction of the LightCycler 480 System: September 2005 Rapid by nature, accurate by design

The LightCycler 480 Real-Time PCR System Roche Applied Science brings you one more breakthrough in the real-time PCR analysis of gene expression and genetic variation Figure 1: LightCycler 480 Instrument and data station. Roche Applied Science s cutting-edge gene analysis technology is now available in a high-throughput, microwell plate-based cycler format (96- or 384-well). Combining amazing speed with exceptional accuracy, the LightCycler 480 Real-Time PCR System is a novel platform for gene-expression and melting curve-based mutation analysis. The compact yet versatile LightCycler 480 benchtop instrument can be interfaced with robotics to create an automated high-throughput solution. Based on innovative hardware and software, the LightCycler 480 Instrument is a modular online PCR device for qualitative or quantitative detection of nucleic acids, genotyping, and mutation analysis. It will meet the needs of a broad range of scientific applications in genomics research, such as array validation, gene-knockdown studies, or SNP analysis. Offering the sensitivity and accuracy one has come to expect only from the Roche Applied Science LightCycler System, the LightCycler 480 Real-Time PCR Instrument goes one step further in providing enhanced throughput and multiplexing capabilities. Supporting all current probe formats and applications in gene-expression and mutation analysis, its built-in versatility allows adaptation to future technological advances in genomic research. Important: Please note that all information contained in this document related to features and specifications of the LightCycler 480 System (instrument, reagents, software) is preliminary. Characteristics of each component of the LightCycler 480 family of products may change until official introduction to the market (planned for September 2005). 2

The LightCycler 480 Real-Time PCR System An ideal combination of speed, accuracy, and versatility Hardware eliminate the edge-effect Innovative temperature control The 96- or 384-well LightCycler 480 thermoblock is based on improved heat-transfer technology, leading to extraordinary well-to-well temperature homogeneity and maximized inter-well, inter-cycle reproducibility. Easily adapt the system to changes in your throughput needs: thermoblocks can be readily exchanged by the user in minutes, and do not require any time-consuming recalibration. High-performance optical system Fluorescence excitation by a high-intensity xenon lamp, and a specially developed signal-collection system, result in maximal sensitivity for any assay format in all channels. Special arrangement of optical components ensures the uniform collection of signals across the plate and makes analysis independent of sample position or differences in reaction volume. The LightCycler 480 System is suitable for many assay formats: HybProbe (FRET, hybridization) probes, DNA-binding dyes (e.g., SYBR Green I), SimpleProbe probes, hydrolysis probes, Molecular Beacons, and others. Freely combine built-in filters (excitation: 450 nm, 483 nm, 523 nm, 558 nm, 615 nm; detection: 500 nm, 533 nm, 568 nm, 610 nm, 640 nm, 670 nm) to fully exploit multiplexing and multicolor capabilities. Software pay for what you need Customizable modular system concept Building on the principles of the well-established, performance-proven LightCycler Software 4.0, the LightCycler 480 platform comes equipped with modules for run control, T m calling, and absolute quantification. Further customize your system to your specific needs by adding advanced analysis modules as required (offered separately): Qualitative (yes/no) detection Absolute quantification with controls Relative quantification with controls Genotyping with controls Statistical analysis tools Reagents especially developed for the LightCycler 480 System Application-specific master mixes A tailor-made hot-start PCR enzyme master mix is available for each type of LightCycler 480 application (quantification or genotyping, generic or specific dyes). Built on Roche s performanceproven FastStart technology, these reagents ensure optimal reproducibility and high dynamic ranges: LightCycler 480 SYBR Green I Master LightCycler 480 Probes Master LightCycler 480 Genotyping Master, specially designed for HybProbe probe or SimpleProbe probe assays, and optimized for melting curve performance. 3

The LightCycler 480 Real-Time PCR System Applications that meet your complex needs Quantification analysis Figure 2: Reproducibility and sensitivity of real-time PCR on the LightCycler 480 Instrument. Serial dilutions of a viral target sequence (seven steps, 10 6 to 10 0 copies/20 µl) were amplified via PCR and detected with HybProbe probes. The whole dilution series was assayed in nine replicates positioned on different areas of the plate (e.g., wells A1 to A7 corresponding to one of the nine replicates). The graphic illustration of the amplification curves shows that the position of a sample in the plate has no significant influence on the results, thus demonstrating very high well-to-well homogeneity over the entire block (e.g., standard deviation for 10 2 copies: 0.11). Melting curve analysis T m (1)ºC T m (2)ºC average 56.19 64.76 minimum 55.77 64.48 maximum 56.56 65.23 standard 0.18 0.17 deviation Figure 3: High-throughput melting curve analysis of samples containing different variants of the polymorphic mammalian MDR-1 gene. Target gene amplification products were subjected to melting curve analysis with HybProbe probes on the LightCycler 480 Instrument. Each sample was measured in 96 replicates distributed evenly across a 384-well plate (wells with turquoise squares: one melting peak; wells with black squares: two melting peaks; empty wells shown in grey). As shown in the graphs and table, highly reproducible melting curves and T m (melting temperature) values were obtained (green curves: homozygous wild-type; blue curves: homozygous mutant; red curves: heterozygous). Data generated by Roche Applied Science, Penzberg, Germany. 4

Benefits of the LightCycler 480 Real-Time PCR System The speed and accuracy of the LightCycler 2.0 System with the throughput, versatility, and compatibility to get the job done Speed rapid temperature control for superb specificity and yield PCR specificity and yield are directly related to the ability of the thermal-cycling system to rapidly and accurately arrive at and maintain reaction temperatures. The LightCycler 480 System utilizes a novel block technology to allow the rapid heating and cooling required to complete a 40-cycle, 384-well qpcr run in less than 40 minutes. The LightCycler 480 System includes reagents that have been optimized for exceptional sensitivity and specificity in this rapid cycling environment. Accuracy unbiased conditions for unambiguous results The key to accurate results is the elimination of uncontrolled variables so that data within and between assays may be relied upon for consistency and reproducibility. The LightCycler 480 System eliminates the edgeeffect found in so many block-based thermalcycling systems. In addition, superior optics and algorithms accounting for instrument-specific parameters ensure the integrity of the data over the entire plate for reaction volumes ranging from 3 to 100 µl. The LightCycler 480 System uses a time-tested, publication-proven software algorithm for efficiency-corrected relative quantification. When necessary, non-linear fit functions for standards are applied. Given the nature of PCR, this method produces more accurate and consistent results than with conventional calculation algorithms. Versatility utmost flexibility for maximum efficiency Why pay for things you don t need or clutter your system with modules you never use? Regardless of your work environment, the LightCycler 480 platform allows you to build a system that best suits your needs with respect to sample load, automation capabilities, analysis tools, and assay chemistry. Easily combine hardware and software modules according to your current application needs while keeping all options for easy, stepwise upgrades as your projects evolve. Five excitation and six emission filters allow you to work with the assay format of your choice, including SYBR Green I, hydrolysis probes, (HybProbe) probes, SimpleProbe probes, and others. Compatibility uncompromising adaptability for a perfect fit Whether you need a system that can grow with you or one that will interface with your current systems, the LightCycler 480 System was designed with you in mind. The integrated bar-code reader is compatible with upstream use of automated sample-preparation workstations. Automated loading is possible in combination with robotic equipment. For integrated workflow monitoring, the LightCycler 480 System offers connectivity to laboratory information management systems (LIMS). 5

Inspiring Discovery LightCycler 480 System Specifications Dimensions Weight Sample numbers Reaction volumes Temperature control Excitation Detection Run time Dynamic range Pre-installed software Additional software Computer Automation capabilities W 60 cm x D 60 cm x H 54.5 cm W 24 in x D 24 in x H 21.5 in 55 kg (121 lbs) Blocks for either 96 or 384 samples, easily exchangeable by user 5 µl - 20 µl (384 well), 20 µl -100 µl (96 well) Peltier-based heating/cooling from 40 C - 95 C Heated lid, PCR without any overlay (e.g., wax or oil) Passive post-run cooling to < 40 C 5 excitation filters, high-intensity broad-spectrum xenon lamp 6 detection filters, signals detected online by CCD camera < 60 minutes (96-well plate) < 40 minutes (384-well plate) 1 to 10 8 copies/well detectable (viral target) Run software Analysis software (absolute quantification, T m calling) Relative quantification including efficiency correction Genotyping via automated sample grouping and allele calling Pentium PC with Windows XP Integrated bar-code reader LIMS connectivity 21 CFR Part 11 compatibility Drawer controllable by software for plate loading 0605-04719280001 Disclaimers and Trademarks: FASTSTART, Hyb Probe, LIGHTCYCLER, and Si mpleprobe are trademarks of Roche. Other brands or product names are trademarks of their respective holders. The technology used for the LightCycler System is licensed from Idaho Technology, Inc., Salt Lake City, UT, USA. NOTICE TO PURCHASER: The LightCycler 480 Instrument is an Authorized Thermal Cycler. Purchase and use of the LightCycler 480 Instrument, in conjunction with Authorized Reagents, provides a limited license for use of the PCR process in life science research. No rights for any application, including any in vitro diagnostic application, are conveyed expressly, by implication or by estoppel under patents owned by Roche Molecular Systems, Inc., F. Hoffmann-La Roche Ltd, or Applera Corporation claiming homogeneous or real-time amplification and detection methods. 2005 Roche Diagnostics GmbH. All rights reserved. In development. For research use only. Not for use in diagnostic procedures. Roche Diagnostics Roche Applied Science 68298 Mannheim Germany www.roche-applied-science.com