Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX



Similar documents
HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions

HP StorageWorks Modular Smart Array 1000 Small Business SAN Kit Hardware and Software Demonstration

EPSON Scan Server & EPSON TWAIN Pro Network

Installing the Microsoft Network Driver Interface

SCSI Card 2930CU. Installation Guide

Winlead Dialer Software Users Manual Addendum 3 Installing Winlead Dialer Software on the Windows 2000 System

e-dpp May 2013 Quick Installation Guide Microsoft Windows 2003 Server, XP, Vista, 7 Access Database

Secure Perfect RAID Recovery Instructions

WHITE PAPER. HP Guide to System Recovery and Restore

HP ProLiant DL380 G5 High Availability Storage Server

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

DP-313 Wireless Print Server

Shared Storage for DIGITAL UNIX Using UltraSCSI Hubs

Important Note Regarding Your Blu ray Drives

Fujitsu SCSI Scanner Installation Procedures Windows 95\98\98SE\ME\2000\XP\Vista

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

Installing Windows 95 Drivers and Utilities for the Cisco Aironet 340/350 Series Client Adapters

PROMISE ARRAY MANAGEMENT (PAM) for

INTRODUCTION INSTALLING THE SCSI CARD 2940UW PRO

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

Serial ATA RAID PCI. User's Manual

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

Network Printing In Windows 95/98/ME

Intel ESB2 SATA RAID Setup Guidelines

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

12 NETWORK MANAGEMENT

PCLinq2 Hi-Speed USB Bridge-Network Cable. Quick Network Setup Guide

Deploying Windows Streaming Media Servers NLB Cluster and metasan

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

Chapter 1 Downloading Images to Your Computer (Windows)

PCI/PXI ETHERNET ADAPTERS

Go to CGTech Help Library. Installing CGTech Products

QuickSpecs. Compaq StorageWorks & SANworks for Datacenter M ODELS P RODUCT DESCRIPTION / OVERVIEW C USTOMER BENEFITS

Moxa Device Manager 2.0 User s Guide

Operating System Installation Guide

Introduction Configuring Your HP Mouse Batteries Replacing the Batteries Mouse Sensor Technology Navigating the HP Mouse Control Center

Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide

Installing the Gerber P2C Plotter USB Driver

HP Compaq Thin Client Imaging Tool HP Compaq Thin Client t5000 Series

ICE.TCP Pro Update Installation Notes


Chapter 2 Preparing Your Network

Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright Lismore Software Systems, Ltd. All rights reserved.

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Chapter 2 Installation

Voice over IP. Orator Dictation Voice-over-IP Quick Start Installation Guide

Installation and Configuration Guide for Cluster Services running on Microsoft Windows 2000 Advanced Server using Acer Altos Servers

How To Configure CU*BASE Encryption

CANON FAX L360 SOFTWARE MANUAL

Microsoft Small Business Server 2000 Installation Guide for HP NetServers E60, E800, LC2000, and HP Server tc3100, and tc4100

Encore SATA2 RAID PCIe Card

Printer Support Guide. FedEx Ship Manager Software

hp digital home networking wireless USB network adapter hn210w quick start guide

Use only a shielded parallel interface cable that is IEEE 1284-compliant and/or a USB cable that is no longer than 6 feet long (1.8 meters).

ENPS-MF1. 1 USB Port. Multifunctional Print Server. Quick Installation Guide V1.0

How to configure the DBxtra Report Web Service on IIS (Internet Information Server)

Intel Rapid Storage Technology

HP User Manual for LSI Integrated RAID on HP xw4200/xw6200/xw8200/xw9300 Workstation

CMP-102U. Quick Installation Guide

Setup for Microsoft Cluster Service ESX Server and VirtualCenter 2.0.1

Printing Options. Netgear FR114P Print Server Installation for Windows XP

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

Corsair Flash Voyager USB 2.0 Flash Drive UFD Utility User s Manual

Outlook Profile Setup Guide Exchange 2010 Quick Start and Detailed Instructions

Installation / Migration Guide for Windows 2000/2003 Servers

TAMUS Terminal Server Setup BPP SQL/Alva

Ultra ATA 133 RAID PCI Pro

Installation Guide. APA-1460 SlimSCSI. PCMCIA-to-SCSI Host Adapter

5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide

Using RAID Admin and Disk Utility

How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade

Setup for PCCharge. Important Pre-Installation Notes for PCCharge. Installation Overview. Step 1 Install And Set Up PCCharge on the Fileserver

Optional Lab: Install, Configure, and Partition a Second Hard Drive in Windows Vista

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

SCSI device drivers are provided for the following operating systems: Microsoft Windows NT Server 4.0 Novell NetWare 5.1

1. Hardware Installation

BioWin Network Installation

PCI ATA 133 RAID Controller Card. User Manual

PIGCHAMP MOBILE. PigCHAMP Knowledge Software. Installation Guide for Mobile Units

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

Crystal Reports Installation Guide

Hi-Speed USB Flash Disk User s Manual Guide

Network Setup Guide. Introduction. Setting up for use over LAN

NAS 249 Virtual Machine Configuration with VirtualBox

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

USING SSL/TLS WITH TERMINAL EMULATION

How do I configure the wireless printer using a USB or Ethernet cable and install the printer driver in Windows?

BounceBack Server Solution Reference Guide

StarWind iscsi SAN: Configuring HA File Server for SMB NAS February 2012

SA-9600 Surface Area Software Manual

drive atapi User s Guide Operating Your Zip Drive Zip Tips Iomega Tools Software Special Information for Windows NT, Windows 95, and Windows/DOS

CONFIGURING MICROSOFT SQL SERVER REPORTING SERVICES

HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD A February 2007

ML310 VxWorks QuickStart Tutorial. Note: Screen shots in this acrobat file appear best when Acrobat Magnification is set to 133.3%

Installation Guide for Crossroads Software s Traffic Collision Database

AcqKnowledge for Windows: Upgrade for 1+MP150s and Domain Network Access or Direct Communication Setup (Domain/Non-domain)

Transcription:

Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX AA RFBCA TE 387373-001

Before You Begin In this Quick Setup Guide we tell you how to create an initial hardware configuration for both the Compaq StorageWorks RAID Array 8000 Fibre Channel Storage Subsystem and the Compaq StorageWorks Enterprise Storage Array 12000 Fibre Channel Storage Subsystem (the RA8000/ESA12000 storage subsystem or the storage subsystem ). To create this configuration you will: Install Storage Building Blocks (SBBs) and Program Cards in the RA8000/ESA12000 storage subsystem cabinet; Install a fibre channel adapter in the server; Connect the fibre channel adapter to the storage subsystem HSG80 controller via a fibre channel hub; Turn on the ac power to the storage subsystem; Install the StorageWorks software. Install the StorageWorks Command Console (SWCC) Client Graphical User Interface; Launch the Client Verify Controller Properties Configure a Storageset. Before you start these steps follow the instructions on the shipping container to unpack the RA8000/ESA12000 storage subsystem. Then move the storage subsystem to the operating location you have selected. Refer to the RA8000/ESA12000 Storage Subsystem User s Guide, EK SMCPR UG. A01 (387404-001) for information about selecting a location. The instructions for installing and connecting storage subsystem components are given for the SW370 pedestal, but apply equally to other Compaq cabinet options. Depending on the storage subsystem you have ordered, you might have to install the storage subsystem in a cabinet and connect the cache module to a cache battery. Refer to the User s Guide for more information. NOTE You can find complete instructions for unpacking and installing the storage subsystem in the User s Guide and in the RA8000/ESA12000 HSG80 Solution Software V8.3 for Hewlett Packard HP-UX Installation Reference Manual, AA RFBEA TE (387374-001). 2 Quick Setup Guide

1Install the SBBs and Program Cards Install the SBBs in the RA8000/ESA12000 Storage Subsystem Cabinet Insert an SBB into the shelf guide slots and slide the SBB into the shelf until the mounting tabs snap into place. For optimum SCSI bus distribution, install the SBBs from left-to-right and from bottom-to-top. Install the PCMCIA Card in the HSG80 Controller Remove the ESD cover from the controller PCMCIA slot. Insert the PCMCIA card in the controller slot. Replace the ESD cover over the controller slot. Repeat the steps if you have two controllers. Compaq StorageWorks RA8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX 3

2 Install the Fibre Channel Adapter NOTE: Your adapter might not look like this. Turn Off the Server Shut down the operating system running on your server. Turn off the power to the server and all attached peripherals. Disconnect power cables from the server. Insert the Adapter in the Server Open the server to gain access to the expansion slots. Insert the adapter in an empty HSC expansion slot. NOTE Refer to the HP Fibre Channel Mass Storage Adapters Service and User s Manual (HP A3636-90002) for more information. Secure the adapter in the slot with the screw provided. 4 Quick Setup Guide

3Connect the fibre channel adapter to the hub and the hub to the storage subsystem controller with the fiberoptic cables supplied. Connect the Fibre Channel Adapter to the Storage Subsystem Controller Be sure to install a GBIC SW module on the hub end of each cable. The following page illustrates the adapter-to controller connections for the four possible configurations: single controller, one server single controller, two servers dual controller, one server dual controller, two servers Compaq StorageWorks RA8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX 5

3 Connect the Fibre Channel Adapter to the Subsystem Controller (Cont d) Single Controller, One Server Dual Controller, One Server Single Controller, Two Servers Dual controller, Two Servers 6 Quick Setup Guide

4 Turn on the Subsystem Power Connect the Hub to an AC Power Outlet Connect one end of the hub ac power cord to the hub. Connect the other end of the ac power cord to an ac outlet. Turn on the Storage Subsystem Power Connect one end of the storage subsystem cabinet ac power cord to the cabinet ac receptacle. AC POWER SWITCH FUSE AC RECEPTACLE Connect the other end of the power cord to an ac outlet. Push in the 1 side of the cabinet ac power switch. When the RESET LED on the HSG80 controller blinks at a rate of once per second the storage subsystem is ready to operate. Turn on the Server Compaq StorageWorks RA8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX 7

5 Install the StorageWorks Software on the HP Host Machine Install the StorageWorks Software Insert the storage subsystem CD ROM in the CD ROM drive. Mount the CD ROM with the command mount /dev/dsk/c1t2d0 /directory Change to the directory cd /tmp Extract the file archive with the command tar xvf /directory/swcc/agent/stm83_hp.tar ******************************************* * Enterprise Storage Management (steam) * * Agent and SCSI pass-through driver * * Installation Script * ******************************************* 1. For StorageWorks SCSI subsystems connected to a 28696A FWD SCSI Adapter, install the SCSI passthrough driver and re-boot the system. 2. Install Agent for all HP-UX systems. 3. Exit NOTE If you are using HP MC/ServiceGuard software and want to install it automatically into a MC/ServiceGuard package and configure the Command Console, refer to Section 2.5 of the RA8000/ESA12000 HSG80 Solution Software V8.3 for HP UX Installation Reference Manual. Execute the installation script./install.sh Choose option 2 in the Installation Script menu to install the StorageWorks software. Follow the text based prompts and enter appropriate information. NOTE For detailed installation information refer to Section 2, Installing the Command Console Agent On Your Host, in the RA8000/ESA12000 HSG80 Solution Software V8.3 for HP-UX Installation Reference Manual. 8 Quick Setup Guide

6 Install and Launch the StorageWorks Command Console (SWCC) Client on the PC Install the SWCC Client Insert the storage subsystem CD ROM in the CD ROM drive. Run File Manager or Windows Explorer. Navigate to the folder drive_letter:\swcc\client Choose Intel client; then double click on Setup. When the setup wizard appears follow the instructions to complete the installation. Launch the Client Click on the Windows taskbar Start button. Move the pointer to Programs > Command Console > HSG80 Storage Window; click on HSG80 Storage Window to display the Connection Selection dialog box. Click on the Network (TCP/IP) button and OK to display the Connect Network (TCP/IP) dialog box. Enter the HP host IP name; then click Detect Subsystems. Client searches and finds the storage subsystems connected to your HP host and displays them in the Subsystem Name text box. Select a storage subsystem and click the Connect button; after two to three minutes the Storage Window is displayed. Compaq StorageWorks RA8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX 9

7 Verify Controller Properties Display Devices in the Devices Windowpane Click on Storage in the Storage Window menu line. SWCC finds installed drives and displays them in a grid by CHANNEL and SCSI TARGET ID number. Verify Properties Double-click on a controller icon in the Storage Window; the Controller Properties screen is displayed. Click on the tabs of the Controller Properties screen successively and confirm that the following values are set: General tab Allocation class: 0 SCSI version: SCSI 2 Cache tab Cache flush time (seconds): 10 Respond to internal cache battery condition: selected Communications LUN tab Confirm that the SWCC virtual LUN is enabled. gjgjggjdfj 10 Quick Setup Guide

8 Configure a Storageset Click on Storage in the Storage Window menu selection line and select Add Virtual Disk to begin Step 1 of the Add Virtual Disk Wizard. Click the Striped parity device group (RAID 3/5) radio button; click Next> for Step 2. Select the devices you want to include in the virtual disk by clicking on the disks listed in the Available storage windowpane; as you select a disk it is added in the Selected devices windowpane. Click Next> for Step 3. Compaq StorageWorks RA8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX 11

8 Configure a Storageset (Cont d) Select the capacity for the virtual disk. You can select the maximum capacity or create partitions by selecting only a portion of the available maximum. If you create partitions, complete all steps for this partition; then access the Wizard again, make the same choices and create anothr partition. Click on the box Save controller configuration to virtual disk. Click Next> for Step 5. Click Next> for Step 4. 12 Quick Setup Guide

8 Configure a Storageset (Cont d) Step 5 recaps your choices; if you are not satisfied, you can return to the applicable Wizard step using the Back button. When you are satisfied with your choices click Finish. When you return to the Storage Window you see the virtual disk you created illustrated in the Virtual disks windowpane. The hourglass on the disk icon indicates the Storageset is being initialized. The drives you used to create the RAIDset are highlighted in the Devices windowpane. Compaq StorageWorks RA8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX 13

Congratulations! You have now completed all the steps required to create an initial hardware configuration for your controller. For more information about using the SWCC software on the HP UX host refer to RA8000/ESA12000 HSG80 Solution Software V8.3 for HP UX Software Installation Guide. For more information about using the SWCC software on the Windows host refer to the Command Console User s Guide. COMPAQ recommends that you verify and record your configuration for future reference. Copyright Compaq Computer Corporation, 1998 All Rights Reserved StorageWorks is a trademark of Compaq Computer Corporation Windows is a registered trademark of Microsoft Corporation All other trademarks and registered trademarks are the property of their respective holders. AA RFBCA TE PRINTED IN USA 387373 001