SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:



Similar documents
Heating, air-conditioning, cooling

Series description: Wilo-Yonos MAXO-D

Series description: Wilo-Yonos MAXO

Catalogue Wilo- Stratos PARA

Series description: Wilo-Star-Z

MEMBRANE VACUUM MINI PUMPS

Series description: Wilo-Drain TC 40

HERZ-Thermal Actuators

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

Conlift1, Conlift2, Conlift2 ph+

Electric Rotary Actuator - On/Off or programmable control actuator

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

ECOCIAT. Domestic hot water heat recovery unit

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Designed for multi-injector endurance testing, the

Multistage high-pressure multistage centrifugal pumps

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX Q [US gpm]

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Electric Flow Boiler

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Freezers - Ultrafreezers. Platilab & Irilab Series

RRV934. Multi-controller. Synco living

Digital inductive conductivity transmitter

ELECTRIC CENTRAL HEATING FLOW BOILER

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

The conditions below apply to the curves shown on the following pages.

DRAIN PUMPS. Synchronous Drain Pumps DPS / DPO

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Hydraulic Control Solutions

SWIMMING POOL HEAT PUMP Owners Manual

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Butterfly Valves PN 6/10/16 for flanged connection

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

PM734F - Technical Data Sheet Winding 28

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Standard offering (pumps)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Data sheet ECC 12 and 22

Oil and Coolant Circulating Heating System. Model - OCSM

EC medium pressure axial fans. The effi cient system solution.

Transformer oil cooler ALFA A02

york air-conditioning products Residential & VRF News 2015

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM. Serial number: Year: --- Page 1

KONRAD. Hybrid Fancoil Series

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

3/2- and 2/2-way cartridge valve type BVE

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

SPEED CONTROL SYSTEM

SIR INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

Energy Saving ECM Motors and Fans Ventilation Catalogue

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Diesel Engine Driven Generators Page 1 of 6

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

SJT / SJM / SJP Large Vertical Pumps

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

4 Posiflow Proportional Solenoid Valves

CRN A-F-G-E-HQQE 3x400D 50 HZ

A S Y N C H R O N O U S M O T O R S

SIGMA GROUP a. s. Divize průmyslová čerpadla

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Laing industrial pumps

Refrigeration Compressed Air Dryer Buran Ultrapulse

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

USER S MANUAL HSC-24A

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

2- and 3-port valves with flanged connections, PN 10

38 Series - Relay interface modules A

Diesel Generating Set

MOLECULAR DRAG PUMPS MDP SERIES

Flush-mounted room thermostats

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

4" SUBMERSIBLE PUMPS

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Transcription:

OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning H m APPLICATIONS SIRIUX SXE For accelerated water circulation for heating or cooling, with optimization of circulator operating point. Central heating, urban heating, commercial or industrial installations; cooling circuits. Air-conditioning systems New, old (renovated) installations or extensions. Circulating pumps recommended for facilities fitted with thermostatically controlled cocks. Qm /hr SIRIUX-- SIRIUX D-- N.T. -/ENG. Éd/-

DESIGN Hydraulic part Single or double body with flanges. D internal plotting of the volute casing and impeller for maximum optimization of the hydraulic performances. An impeller seal between the pump body and the impeller improves performances further by limiting the internal recycling of the fluid. The pump body is fully cataphoresis coated to ensure corrosion resistance. Motor V Hz single-phase Wet rotor motor; bearing bushes lubricated by the fluid pumped. E.C.M. (Electronically Commuted Motor) synchronous motor, equipped with a permanent magnet rotor. The stator s rotating magnetic field is generated by the electronic switching of the coils. This rotating field creates a continuous torque through attraction between the rotor s opposite magnetic poles, controlling its position (synchronous motor). This ensures the optimum performance of the motor, whatever its speed. The wet rotor and the windings are separated by a composite, and therefore completely amagnetic, sleeve, to reduce motor losses. SXE with AC motor BENEFITS Energy savings High efficiency circulators, with optimization of the operating point. Energy savings of up to % compared to a traditional circulator. All-purpose These circulators are compatible with all types of heating, air-conditioning and refrigeration systems. The standard version covers a fluid temperature range from C to + C. Noise control Eliminating of whistling and hydraulic noises in the thermostatically controlled cocks. Automatic adapting of speeds to the system s needs. Reliability - Fully automatic operation requiring neither draining nor servicing. A double filter system prevents solid particles from getting into the rotor chamber. A rotating seal between the impeller and the flange limits water exchanges with the motor to the bare minimum. Filter - Circulators shut down via the on/off control start up for a few moments once a day to prevent blocking due to a long period of inactivity. - The electronic modules have a non-volatile memory for data storage. The setpoints are protected in the case of a power cut. - Single or double circulators equipped with IF modules (optional, one IF module per motor) allow many control or remote monitoring functions. Ergonomics Easy electrical connections and adjustments facilitated by direct access via the control module s front panel. The position of the display on the LCD screen may be adjusted according to the position of the control module. STANDARD CONSTRUCTION Main parts Material Pump body FGL Impeller Composite (PPS % GF) Shaft Chromium steel (X Cr) Bearing bushes Metal impregnated carbon SIRIUX with EC motor Speed: to rpm Mains voltage: ph, V ± % Frequency: Hz Insulation class: F ( C) Protection index: IP CEM compliance: EN - emission EN -- immunity EN -- Protection differential (FI) All current FI protection differentials compliant with EN - are permitted. These differential circuit breakers are identified by ou. Filter IDENTIFICATION SIRIUX - SIRIUX - D - - High eff. circulator Single pump or D: double pump Nominal diameter (ND) of suct/dis. flanges Head (in dm) at nominal flow MIN SUCTION LOAD (MWC) according to the operating temperature Fluid temperature Siriux Siriux D - - - - - - - C 9 C C

CONNECTIONS Option: IF modules FITTING OPERATION On vertical or horizontal pipes the motor shaft must always be horizontal. L N PE SSM or DP - V Ext. Off or DP - V SBM DP - V Ext. Min. In terminal boxes L N: mains connection, V Hz single-phase current PE: earth SSM: dry contact for fault indicator (normal closed, open by default). Max load: A V AC On IF modules (optional) DP: double pump (or single pump) management - V: analogue input for external control signal Ext. Off: remote on-off (through external contact) SBM: dry contact for operating state indicator (contact usually open; closed if in operating state) Ext. Min: remote operating or curve (through external contact)

OPERATING PRINCIPLE The heating or air-conditioning needs of a building vary according to whether it is day or night, but also during the day according to changes in the outside temperature, etc., and even from one point of the building to another as the thermostatically controlled cocks or -way valves are closed. The self-regulated circulator automatically adjusts its rotation speed according to the mains network s loss of load, in order to maintain a minimum electricity consumption (ECM technology) and a low operating noise level. The circulator s properties are adjusted automatically according to the heating or cooling needs of the system. Manual adjustment Parameterization of basic functions, i.e.: - ON/OFF; - control mode, P constant, P variable - and speed adjustment; - automatic adjustment on minimum speed. Constant pressure With this regulation mode, electronic control maintains the constant differential pressure of the circulating pump whatever the flow rate, depending on the predefined pressure instruction. Variable pressure With this regulation mode, the electronic control allows reducing the differential pressure (manometric head) in case of flow reduction, depending on the predefined differential pressure instruction. Speed adjustment The speed may be adjusted manually to a constant value between and rpm. Automatic idling The considerable development of day/night adjustment installations has produced hourly or thermostatically regulated boilers, but not by the adjustment of circulating pumps, which consume energy accelerating cold water circulation. External control (with IF module) This control mode deactivates controlling by the control module. It provides the following functions by means of a - V analogue signal: - remote adjusting of the setpoint P constant remote adjusting of the setpoint P variable - remote adjusting of the speed between the min speed and the max speed - external on-off Double circulators Equipped with two IF (InterFace) units, the Siriux benefits from the following extra functions: Duty/Stand-by The flow requested is provided by a single pump, the other pump starting up in case of fault on first pump or after hours of actual operation of the latter. Cascade operation At minimum load, only the pump in service operates. The backup pump triggers when radiators request a higher flow rate. From this point (switchover point), the nominal speed of the two pumps increases synchronously in case of need. After hours of actual operation, there is built-in (automatic) changeover of the master pump which becomes slave. This function increases energy saving as compared to usual operation in parallel by avoiding numerous locking/ triggering. (See working curves in cascade opposite). Additional functions (IF modules) There are three types of IF module: - IF module Ext. Off - IF module SBM - IF module Ext. Min. with common functions and dedicated function. Modules Ext. Off SBM Ext. Min Functions Double pump management - V analogue input Remote on/off Operation indicator Remote operation Remote monitoring In addition, a dry contact (open by default) allows the remote monitoring of any operating incident (e.g. through a BMS).

OPERATING PRINCIPLE CURVE Operation in P constant Operation in P variable Operation in automatic idling H H n H min P constant mode Operation area not used Electronic control maintains constant the differential pressure produced by the pump at the differential pressure value of Hn instruction, up to the curve of operating data through the authorized flow rating. Q H H n / H n H min P variable mode Additional savings compared with constant P mode Electronic control modifies linearly the differential pressure value between Hn and / Hn instruction to be met by the pump. Differential pressure value of H instruction increases or decreases according to the flow. Q Starting temperature (C ) Power input Température départ/heures This device enables making up to % additional saving as compared to operation in P constant. When the heating facility reaches a certain low temperature, the circulator runs on a constant reduced speed until a new rise in temperature. (%) Power input Operation in synchronized cascade P (kw),,, Usual cascade Cascade with performance optimization CONTROLS n [/min] nmax, nmin,, Qm /hr Switchover point Aus U[V] Remote controlling of the speed by a - V signal Operation in cascade of a SIRIUX fitted with two IF units. At equivalent flow rate, the circulator automatically uses the curve of least power. (Ex: SIRIUX - - D p-c - H n = m). H [m] H max H min Aus U[V] Remote controlling of the differential head by a - V signal

TABLE OF FUNCTIONS Manual functions Pump On/Off Choice of regulation mode (P-c, P-v, regulator) Adjusting of the differential pressure setpoint Manual adjusting of the speed Adjusting of the display s position Automatic day/night adjusting Automatic functions Continuous P-c speed adjusting Continuous P-v speed adjusting Motor thermal protection, with automatic activation Anti-blocking function (long period of inactivity) Day/night switching SIRIUX SIRIUX-D External control functions Remote fault indicator Remote On/Off with IF module Remote operation with IF module Remote operating indicator with IF module - V control input for remote speed adjusting with IF module - V control input for remote setpoint adjusting with IF module Signaling and display functions LCD display to display the pump data (orientable) Error codes Fault signaling indicator light Double pump ( x single pump) management Duty/stand-by mode (automatic switching in the case of a fault/changing of the pump according to time) Cascade mode (switching on/off at peak loads for optimized energy consumption) with IF modules with IF modules Choose the appropriate IF module With IF modules

SIRIUX - AND SIRIUX-D - HYDRAULIC PERFORMANCES SIRIUX- ~ V - ND SIRIUX- ~ V - DN ND Qm /hr Qm /hr m m m m m m m Qm /h,,,, m Qm /h,,,, SIRIUX-D- ~ V - ND pump ON SIRIUX-D- ~ V - ND pump ON Qm /hr Qm /hr m m m m m m Qm /hr m m pump in operation see SIRIUX- Qm /hr pump in operation see SIRIUX-

SIRIUX - AND SIRIUX-D - HYDRAULIC PERFORMANCES SIRIUX- ~ V - ND SIRIUX- ~ V - ND Qm /hr Qm /hr m m m m m m m Qm /hr Qm /hr 9 SIRIUX-D- ~ V - DN pump ON 9 SIRIUX-D- ~ V - DN pump ON Qm /h Qm /h m m m m m Qm /hr m m pump in operation see SIRIUX- pump in operation see SIRIUX- Qm /hr

SIRIUX - AND SIRIUX-D - HYDRAULIC PERFORMANCES SIRIUX- ~ V - ND SIRIUX- ~ V - ND Qm /hr Qm /hr m m m m m m m m Qm /hr m m m m m Qm /hr m SIRIUX-D- ~ V - ND pump ON SIRIUX-D- ~ V - ND pump ON Qm /hr Qm /hr m m m m m m m m pump in operation see SIRIUX- Qm /hr Qm /hr m m pump in operation see SIRIUX- m m m 9

SIRIUX - AND SIRIUX-D - HYDRAULIC PERFORMANCES SIRIUX- ~ V - ND SIRIUX- ~ V - ND Qm /hr Qm /hr m m m m m m Qm /hr Qm /hr 9 9 SIRIUX-D- ~ V - ND pump ON 9 9 SIRIUX-D- ~ V - ND pump ON Qm /hr Qm /hr m m m m m Qm /hr m m pump in operation see SIRIUX- Qm /hr pump in operation see SIRIUX-

SIRIUX - AND SIRIUX-D - HYDRAULIC PERFORMANCES 9 SIRIUX- ~ V - ND 9 SIRIUX- ~ V - ND Qm /hr Qm /hr Qm /hr m m m m m m m m Qm /hr SIRIUX-D- ~ V - ND pump ON SIRIUX-D- ~ V - ND pump ON Qm /hr Qm /hr Qm /hr m m m m m pump in operation see SIRIUX- Qm /hr m m m pump in operation see SIRIUX-

SIRIUX - AND SIRIUX-D - HYDRAULIC PERFORMANCES SIRIUX- ~ V - ND SIRIUX- ~ V - ND Qm /hr Qm /hr m m m m m m m Qm /hr m m m m m Qm /hr 9 SIRIUX-D- ~ V - ND pump ON 9 SIRIUX-D- ~ V - ND pump ON Qm /hr Qm /hr Qm /hr m m m m m m m pump in operation pump in operation see SIRIUX- see SIRIUX- Qm /hr m m m m m

SIRIUX - HYDRAULIC PERFORMANCES SIRIUX- ~ V - ND SIRIUX- ~ V - ND Qm /hr Qm /hr m m m m m Qm /hr m m m m Qm /hr

FEATURES a) Packaging Supplied packaged with flange gaskets and bolts, without counterflanges (optional). ELECTRICAL DATA AND DIMENSIONS b b a a b) Maintenance Replacing of motor unit and electronic module. RECOMMENDED ACCESSORIES NP / weldable round counterflanges Isolation valves: IF modules - SBM - or Ext. Off - or Ext. l l l l FLANGES Ø D Ø kl Ø kl Ø d DN Pg, Pg9 Pg b b b b n x d L n x d L DN ØD Ød ØkL/kL nxdl/dl mm mm mm St. x mm Siriux - 9/ x/9 Siriux - / x/9 Siriux - / x/9 Siriux - 99 / x/9 Siriux - 99 / x/9 Siriux - 99 / x/9 Siriux - / x/9 l l Pg, Pg9 Pg l a a Order a a a i i i i i b b b b b P Speed P I cable gland Reference mm mm mm mm mm mm mm mm mm mm mm mm mm W tr/min W A Siriux -,, - -,-, x/x9/x, Siriux -,, - -,-, x/x9/x, Siriux - 9,, - -,-, x/x9/x, Siriux -,, - -,-, x/x9/x, Siriux - 9,, - -,-, x/x9/x, Siriux - 9,, - -,-, x/x9/x, Siriux - 9,, - -,-, x/x9/x, Siriux D - - -,-, x/x9/x, Siriux D - 99 - -,-, x/x9/x, Siriux D - - -,-, x/x9/x, Siriux D - - -,-, x/x9/x, Siriux D - 9 - -,-, x/x9/x, Siriux D - 9 - -,-, x/x9/x,

NOTES

NOTES bd de la République - Espace Lumière - Bât. - Chatou Cedex - France Tél. : + () - Fax. : + () 9 - www.salmson.com