ETNALC Installation Manual



Similar documents
CONNING DISPLAY (Box -Pc)

ESD Plastic light pallet Doc. Num. N x 800 x 150 mm Doc. Part 001 Doc. Ver. 01. Contents

Butt Fusion Welding of HDPE Pipes Work Procedure

GK Packing System Welding Instructions

LarsLap model C for cutting, milling grinding and lapping seats and flanges on globe, safety and control valves

AMPSEAL* Automotive Plug Connector and Header Assembly

TARIFF CODE and updates standard

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

High Strain Dynamic Load Testing of Drilled Shafts

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

MGB Chrome Bumper Conversion

Transducer Installation

NATIONAL INSTITUTE OF BIOLOGICALS

Guidelines for Earthquake Bracing of Residential Water Heaters

Bypass level indicator With magnetic display Model BNA

Flash Butt Welding Machines

Direct steam injection humidifiers

Installation Instructions

HORIZONTAL INSTALLATION

Installation Instructions

BB-18 Black Body High Vacuum System Technical Description

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

Rack installation instructions

Munchkin Heat Exchanger Maintenance

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Appendix A - Values of rb_response with Windows 95, Windows NT and MS-DOS. Appendix B - Error Messages of the SEND/RECEIVE Functions

How To Use An Akua Magnetic Lime Scale Preventing Device

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Installation Instructions For Slider Casement Air Conditioners

Specifications sheet PIXIS. Mini LED spot

COIL PAC. Subec AB, Sprängarvägen 16, Saltsjö-Boo, Sweden, Tel.: , Fax: , info@subec.se

PARTNERS and RESPONSABILITIES

18. SKATES, PLATFORM HAND TRUCKS, LIFTING TABLES AND HAND TROLLEYS

PS6500 Storage Arrays Rack Mount Instructions

GPD Rubber Press Seals

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Series 510 Submersible Level Transmitters

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

Rack Installation Instructions

19 DYNAmax Free Standing Server C A B I N E T s

Shunt lock function 3066

19 DYNAmax Free Standing Server C A B I N E T s

1. Description. 2. List of Accessories included A B C F G H

1.1 DIMENSIONS AND WEIGHT PAG LOAD CENTRE FOR LIFTING PAG STORAGE CONDITIONS PAG. 2

Packaged Terminal Air Conditioner Wall Sleeve Installation

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

\ srl High Technology Gear Reducers and Cardan Shafts CERTIFIED QUALITY SYSTEM: UNI ISO EN 9001:2008 ICIM 2779/2; IQNET N. IT UNIVERSAL SHAFT

Installation instruction CASAFLEX - Connecting piece DN 100

Accessories for GF and RA machines

DIE SETS - MACHINED PLATES ACCORDING TO DRAWING CONTENTS

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

I BEAM TRACK INSTALLATION

EUROTUBO DELTALAB 4. PETRI DISHES AND LOOPS

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

TELESCOPE Motorized Lighting Suspension

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Quick Connect Boxes Inside Gloveboxes

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS


Removable Aluminium posts

Toroidal Conductivity Sensor

SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List

Field Welding Inspection Guide

Machine Documentation BELKI Oil Separator type 301

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Guidelines for Earthquake Bracing Residential Water Heaters

Sliding and Folding Door Fittings Sliding Door Accessories

Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers

LIEBERT VNSA Installation Sheet

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Machine needle shut-off nozzle type-a

Spare Parts List Activ A 12OV Activ A 15OV Activ A 20OV Activ A 25OV

Manual piston sampler...m 11

SERIES 238 WINDOWS. NOTE: Read instructions completely before attempting any installation.

OPERATING INSTRUCTIONS

ASTM A860/A860M-09 Standard Specification for Wrought High Strength. Ferritic Steel Butt Welding Fittings. 1. Scope :- 2. Reference Documents :-

Installation Instructions

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

HOW TO MAKE A MOTOR BRACKET

RPV - RP - RA air handling units

Robot Welding Torch System

Repair of a Hull 15 m below the Waterline

Chapter2. Installation

Brochure EX

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

FRAME DOOR OPENING, DOOR AND SIDE PANEL OUTER

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

TYPE APPROVAL CERTIFICATE

Flue Installation. High Efficiency Condensing Boilers

all VAC LIFT ALL-VAC-LIFT Phone Redstart Street Fax

Rules for Classification and Construction Additional Rules and Guidelines

Transcription:

Combo Tank Aluminium ETNALC Installation Manual SKIPPER Electronics AS Telephone: +47 23 30 22 70 Enebakkveien 150 Telefax: +47 23 30 22 71 P. O. Box 151, Manglerud E-mail: support@skipper.no 0612 Oslo, Norway Co. reg. no: NO-965378847-MVA www.skipper.no Document no: DM-BETNALC-SA Rev 1320

Weitergabe sowie vervielfältigung dieser unterlage, verwertung und mitteilung ihres inhaltes nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu schadenersatz. Copying of this document, and giving it to others and the use or communication of contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. Toute communication ou reproduction de ce document, toute exploitation ou communication de ou son contenu sont interdites, sauf autorisation expresse. Tout manquement à cette règle est illicite et expose son auteur au versement de dommeges et intèrèts. Sin nuestra expresa autorización, queda terminantemente prohibida la reproducción total o parcial de este documento, asì como su uso Indebido y/o su exhibición o comunicación a terceros. De los infractores Se exigirá el correspondiente resarcimiento de daños y perjuicios. Page 2 of 12

Contents 1. General information... 4 2. Combo Aluminium Tank Ø 160 mm... 6 3. Aluminium Welding Procedure... 7 4. Cable Pipe for Aluminium Tank... 8 5. Transducer Mounting... 9 6. DL 270 in 160 mm Aluminium Combo Tank...10 7. 50 khz in 160 mm Aluminium Combo Tank...11 8. EML224 in 160 mm Aluminium Combo Tank...12 Page 3 of 12

1. General information The SKIPPER ETNALC Combo Tank Aluminium is used for installation of: 1. Echo Sounder transducer type (24, 38, 50 and 200 khz). Optional Ice/Sand protection for same. 2. DL850 Doppler Log. 3. EML224 Speed Log. Caution! Be aware that the sensor/transducer contains high precision parts and therefore proper handling when mounting is essential for the final result. When handling the Tank, all lifting devices must be attached on the outside of the Tank. It is very important to not insert any chains, wire, rope or any other device into the Tank chamber. This to avoid damaging and any kind of pollution of the Tank The SKIPPER ETNALC Combo Tank Aluminium is delivered final assembled. The parts necessary for the sensor and transducer mounting will be found packed with the sensor/transducer. First of all, it must be decided where the Tank should be installed. Normally, this will be in the fore part of the ship, in the centerline, or as close to the centerline as possible. Optimal system operation is achieved by fitting the sensor/transducer as deep as possible on the hull. The active surface of the sensor must be installed with front face a maximum of +/-1 degree to the ships horizontal plane. (Speed Logs) The active surface of the transducer must be installed with front face a maximum of +/-7 degree to the ships horizontal plane. (Echo Sounder). Do not mount sensor/transducers close to the bow thruster propeller outlets, or aft of other hull installations (outlets, vents or other protruding details) who may create aeration or turbulence. It is necessary to select a part of the hull that is submerged and free from turbulence and aeration under all load and speed conditions, and to avoid positions where air is trapped in heavy weather. If a flat, horizontal section is not available for the sensor/transducer fitting, the shipyard must construct a suitable bed. Welding seams in this area should be smoothed and rounded off, in order not to create turbulence or aeration at speed. Protect the active element of the transducer/sensors during transport and installation, and do not paint the surface. Page 4 of 12

Important Sensors for Speed Log and Echo Sounder are delivered with a fixed cable. Needed attention must be taken to allow easy replacement/pulling of new cable during maintenance. SKIPPER Electronics AS will recommend installation positions if GA-drawings (General arrangements), lines drawings and frame drawings are made available for study. Condition. The welding to hull structures and structural support of the items may be subject to separate approval by classification societies for each installation on board a ship. Standard welding practice, methods and procedures should be observed, but may vary. (See welding notes). WELDING NOTES! All bottom parts and flanges for welding are precisely machined parts. During welding of these parts to the ship s hull plates, careful attention must be paid to avoid construction strain on the bottom parts and flanges. Let parts cool down during welding. Over heating may change fit and form and result in non-conformity with intended sensor/ transducer. Welding to thick hull steel plates will exert high stress on bottom parts and flanges. Especially care must be taken during welding of stainless steel flanges. Work must be performed by a qualified and certified welder. Page 5 of 12

2. Combo Aluminium Tank Ø 160 mm 100217 Page 6 of 12

3. Aluminium Welding Procedure 1 RevNo Revision note 2 3 4 Date Signature Checked A Max 1 for Speed Logs Max 7 for Echo Sounders 30 cm 30 cm Ahead A Max 20 Flush Flush Protruding Utstikkende Build a streamlined blester around the tank B B ALUMINIUM WELDING PROCEDYRE C Welding Wire: ALMg4.5Mn or equal (1.0) - 1.2 mm Welding Gas: Argon 4.6 or Misio n 99.99 Gas flow: 16-19 L/min. 1 135-140 A 2 155-220 A C D 1 2 DEGREASE ALUMINIUM CAREFULLY Brush with Stainless Steel Brush within 30 min. prior to welding. Preheat with Propan Gas thickest part min. 130. No pendulous movment during welding. No Airdraft during welding at welding Position. All Materials: DnV, GL or equal Certificates. Welder qualification: Valid Certificate for the specified thickness and welding Positions. DnV, GL or equal. D E 60 Observe proper grinding of outer Hull welding. Sveis på utsiden av bunn må planslipes. SVEISEPROSEDYRE FOR ALUMINIUM Sveisetråd: AlMg4,5Mn eller tilsv. (1,0) - 1,2 mm Dekk-gass: Argon 4,6 eller Mision 99,99. Gassflyt: 16-19 L/min. 1 135-140 A 2 155-220 A AVFETT ALUMINIUMEN FORSIKTIG Børst med rustfri stålbørste innen 30 min. før sveising. Forvarm med propangass tykkeste del min. 130 C. Ingen pendling under sveising. Luftdrag i sveiseområdet må unngås. Materialer: DnV, GL eller tilsv.sertifikater. Sveiseoperatørs kvalifikasjoner: Gyldig sertifikat for spesifisert tykkelse og sveiseområde. DnV, GL eller tilsv. E F Itemref Quantity Title/Name, designation, material, dimension etc Article No./Reference Designed by Checked by Approved by - date File name Date Scale A.Matre 2007.11.19 SKIPPER Electronics AS 1 Installation and welding guidance for Tranducer Tank- Alu. TCA-2041-Rev-01 Edition 2013.05.15 4 Sheet 1/1 F Page 7 of 12

1 RevNo Revision note Yard Supply 4. Cable Pipe for Aluminium Tank 2 3 Date 4 Signature Checked A Watertight junction box must be sited for easy access in explosion-safe place, over max. waterline. A Aluminium Pipe, min. 35 mm diam. Inside. Wall thickness: - Minimum10 mm B C Fixing Clamp Festeklammer Yard Supply Fixing Clamp Festeklammer Max. 25x Pipe diam. 500 mm above the highest possible water line Quality of material: - Stated in Veritas Rules Pt.2 Ch.2 Metallic Materials Sec.9 The Pipe to be welded before pulling the Cable. Expanding possibilities must be arranged. Maximum distance between Pipe Clamps, 25x Pipe diam. ************ Vanntett koplingsboks plasseres på ikke eksplosjonsfarlig, lett tilgjengelig sted, over maks. vannlinje. Aluminiumsrør innv. diam. min. 35 mm. Veggtykkelse: Minimum 10 mm. Materialkvalitet: - Se Veritas regler Pt.2 Ch.2 Metallic Materials Sec.9 Røret sveises inn med tilstrekkelig ekspansjonsmulighet, før kabelen trekkes. Maks. klammeravstand på røret, 25x rørdiam. B C Ø35 D D E E F Itemref Designed by A.Matre Quantity SKIPPER Electronics AS 1 Title/Name, designation, material, dimension etc Checked by Approved by - date File name Article No./Reference Date 2007.12.03 Revision 00 Scale Cable pipe for transducer tank aluminium TCA-2075 Draw. Edition 2013.05.15 4 Sheet 01 F Page 8 of 12

5. Transducer Mounting Page 9 of 12

6. DL 270 in 160 mm Aluminium Combo Tank 02 01 0.2 mm. 1 1 04 6 01 02 04 Page 10 of 12

7. 50 khz in 160 mm Aluminium Combo Tank 02 08 05 04 06 01 03 07 Page 11 of 12

8. EML224 in 160 mm Aluminium Combo Tank 01 02 04 Page 12 of 12