COMPARISON OF DIFFERENT HVAC SYSTEMS IN MULTI- STOREY APARTMENT BUILDINGS IN HELSINKI



Similar documents
Horizontal ventilation units

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

Energy Efficient HVAC-system and Building Design

Mechanical and Natural Ventilation

Energy savings in the residential area are essential in

HVAC Processes. Lecture 7

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Crawl space heat and moisture behaviour

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

HEATING, VENTILATION & AIR CONDITIONING

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Combi Unit Genius. The energy efficient Building Service Centre

Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program

How To Get A Passive House

The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

Which filter class for supply air is required in a typical HVAC system?

Halton - Achieving Energy Efficiency in School Design

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

All the best brands all under one roof

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

Information paper 20. Prepared by: David Clark. book:

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

OptiNet Applications. A Review of the Unique Requirements for a Facility Monitoring System. White Paper Series

IEQ-15 Air Distribution System

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

Martin Krus, Klaus Sedlbauer, Herbert Sinnesbichler

Lesson 36 Selection Of Air Conditioning Systems

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses

How To Design A Room Air Conditioning System

GREEN BAY AREA PUBLIC SCHOOL DISTRICT Board Policy Manual ENERGY MANAGEMENT

INDOOR AIR QUALITY ASSESSMENT

Whole House Dehumidification for Occupant Comfort and Energy Savings

White Paper Nest Learning Thermostat Efficiency Simulation for France. Nest Labs September 2014

Preliminary Final Proposal

Residential Duct Systems for New and Retrofit Homes

RESNET National Rater Test Study Guide Outline

Scope of Work. See for resources available

Get the FACTS about SEER and Deliver Better Customer Value

ECHO System for Basements

AQUACIAT2 HYBRID THE COMPACT DUAL-ENERGY SOLUTION HEAT PUMP & GAS BOILER. Cooling and heating capacities of 45 to 80 kw AVAILABLE 2 ND QUARTER OF 2014

Air Conditioning, Heating and Refrigeration (HVAC) Technology Diploma

Molds and mildew are fungi that grow

VENTILATION RATES AND IAQ IN EUROPEAN STANDARDS AND NATIONAL REGULATIONS

Energy audit in Finland

DK2 IEA. Replacing mechanical ventilation with natural ventilation at Enghøjskolen school in Denmark

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

Energy Efficiency HOSPITALITY.

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

A Roof Integrated Solar Heating System Without Storage

Mistrale. Fusion Terminal

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

Variable Air Volume - VAV

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Heating and Ventilation

WORKER PERFORMANCE AND VENTILATION: ANALYSES OF TIME-SERIES DATA FOR A GROUP OF CALL-CENTER WORKERS

ASTACEA4 Inspect complex/central air conditioning systems

for K-12 School Buildings

Application of Building Energy Simulation to Air-conditioning Design

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Delivering exceptional performance and Ecovalue. Ecocent

Installation, operation and maintenance manual TX 35A

The Finnish Classification of Indoor Environment and Material Emissions

Passive & Active Design

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

BCA Green Mark for Restaurants

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS -

Draft UCL Heating, Cooling and Ventilation Policy

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

WATER DAMAGE INVESTIGATION. Massachusetts Department of Public Utilities 1 South Station Boston, Massachusetts

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

Climotion ensures a better climate. Better comfort and lower costs in all buildings. Bosch Energy and Building Solutions

How to choose a heat pump and use it wisely

CEN/TC 156. pren Date: CEN/TC 156. Secretariat: BSI ICS: Descriptors:

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

Energy Efficiency. Bars & RestauRants.

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

Transcription:

Proceedings of Healthy Buildings 2000, Vol. 2 675 COMPARISON OF DIFFERENT HVAC SYSTEMS IN MULTI- STOREY APARTMENT BUILDINGS IN HELSINKI Mikko Saari 1, Juhani Laine 1, Sami Karjalainen 1 and Klaus Hamström 2 1 Technical Research Centre of Finland (VTT), VTT Building Technology, Finland 2 Housing Production Bureau of Helsinki (ATT), Finland ABSTRACT Good indoor air quality can be ensured most economically with an apartment based supply and exhaust air ventilation system with heat recovery. This paper describes an in-situ comparison study of four different buildings and HVAC systems. The main tasks were to study the energy consumption, indoor environment and operation of the mechanical systems. The air quality was good in all buildings with mechanical supply and exhaust air ventilation systems. Most complaints of inadequate ventilation as well as the highest CO 2 concentration and relative humidity were measured in the building with a centralized exhaust air ventilation system. The measured district heating energy consumption of three of the buildings was 47-49 kwh/m³, while the consumption of the building with apartment based mechanical supply and exhaust air ventilation system with heat recovery was only 36 kwh/m³ (30 % lower). The electricity consumption of the fans was twice as high in centralized ventilation units as in apartment based units. KEYWORDS: air change rate, costs, energy, heating, ventilation system, residential, heat recovery INTRODUCTION The objective of this study was to compare four different buildings and HVAC systems in practice and to determine the best solutions for the City of Helsinki to utilize when designing new apartment buildings. The main tasks were to study the energy consumption and indoor environment. [1] METHODS Four multi-storey apartment buildings (Abraham Wetter Street, Herttoniemi Harbour, Castle Builder's Corner and Ship Bay Arc) built by the Housing Production Bureau of Helsinki were studied for a period of two years in 1995-1997. The study focused on the functioning of HVAC-systems, the energy consumption of the buildings, the indoor climate of the apartments, the need of maintenance as well as the opinions of the occupants. The buildings were located in the Herttoniemi area in Helsinki and had district heating. Three of the buildings used traditional water based radiators for heating and one building used ventilation heating. The oldest building was built in 1989 and had a mechanical exhaust air ventilation system with common ducts. One of the more recently built buildings (1995) had apartment based supply and exhaust air ventilation units with heat recovery. The two other newer buildings had centralized supply

676 Design and operation of HVAC systems and exhaust air ventilation units with heat recovery. The building with ventilation heating had a runaround water-glycol heat exchanger for heat recovery. It also had energy efficient windows to keep the energy consumption low. Figure 1 shows the principle of the heating and ventilation systems in each building. 1. Abraham Wetter Street: water based radiators and a mechanical exhaust air ventilation system with common ducts. 3. Castle Builder's Corner: water based radiators and centralized supply and exhaust air ventilation units with heat recovery. 2. Herttoniemi Harbour: water based radiators and apartment based supply and exhaust air ventilation units with heat recovery. 4. Ship Bay Arc: ventilation heating system and centralized supply and exhaust air ventilation units with heat recovery.

Proceedings of Healthy Buildings 2000, Vol. 2 677 Figure 1. Schematic of the heating and ventilation system in different buildings. The consumption of heating energy and electricity was monitored monthly during the two year study. The indoor climate was monitored in four randomly selected apartments in each building for a two week intensive period. During the same period, the operation of the heating and ventilation systems were monitored. Average exhaust air flows of the ventilation systems were measured once in 1995. A questionnaire study for opinions of the inhabitants was carried out once in 1997. Maintenance costs were monitored by a service company. RESULTS A summary of the results of the buildings is presented in Table 1. Table 1. Comparison of results of the different buildings. Feature 1 Abraham Wetter Street 2 Herttoniemi Harbour Building 3 4 Castle Builder's Ship Bay Corner Arc Building volume, m³ 17 290 25 563 17 110 26 050 Apartment area, m² 4 174 5 262 3 782 5 678 Construction year (construction cost, /m²) 1989 (n.a.) 1995 (988) 1995 (1 146) 1995 (1 147) Heating system Water based radiators Water based radiators Water based radiators Ventilation heating Ventilation system Mechanical exhaust Apartment based supply and exhaust Centralised supply and exhaust Centralised supply and exhaust Temperature efficiency of the heat 0 50 35-45 40-45 Average 3. Castle indoor Builder's temperature, Corner: Cwater based 23.1 radiators 22.6 4. Ship Bay Arc: 22.7ventilation heating 22.7 system and Acceptable and centralised indoor temperature, supply and % exhaust of theair ventilation centralised supply and exhaust air ventilation answers units with heat recovery. 59 38 units with heat 58recovery. 49 Ventilation coefficient, 1/h 0.59 0.70 0.90 0.95 Exhaust air flow, dm³/s/person 10.5 12.0 16.7 18.6 General ventilation insufficient, % of the answers 15 12 12 9 Ventilation insufficient while cooking, % of the answers 61 Occupant control 47 36 Window opening used, % of the answers 86 81 69 80 Average carbon dioxide level, ppm 909 545 521 594 Relative humidity in winter, % 39.6 26.0 25.7 22.8 Absolute humidity difference (indoor-outdoor), g/kg 4.5 1.4 1.8 1.7 District heating energy, kwh/m³/year 49 36 48 47 Electricity of fans, kwh/apartment/year 260 680 1 090 1 360 Specific electricity of fans, kw/(m³/s) *) 1.0 2.2 2.8 3.7 Energy cost, /m²/month 0.86 0.90 1.10 0.98 Usage and maintenance, /m²/month 0.048 0.083 0.075 0.053

678 Design and operation of HVAC systems Cost of changing air filters in ventilation units, /apartment/change None 10 7 10 *) Specific electricity of fans is the total electricity effect divided by the total exhaust air volume flow.

Proceedings of Healthy Buildings 2000, Vol. 2 679 Indoor climate and air quality The average indoor air temperatures in the buildings were 22.6-23.1 C even though the design temperature was 21 C. The opinions of the occupants did not vary significantly between the four buildings. Most of the occupants were happy with the indoor temperature, but almost half of them indicated draught from time to time. More than 60 % were satisfied with the indoor air humidity in three of the buildings. Only 47 % were satisfied with the indoor air humidity in the building with ventilation heating (Ship Bay Arc). The buildings with mechanical exhaust air ventilation (Abraham Wetter Street) and the apartment based ventilation (Herttoniemi Harbour) had the largest number of complaints (46 %) of poor indoor air quality. The fewest complaints came from the building with ventilation heating (Ship Bay Arc), which had the highest ventilation rate. The buildings with mechanical exhaust air ventilation and apartment based ventilation had the largest number of occupants detecting odors. The building with ventilation heating had the lowest odor detection, where up to 71 % said that there were no odors at all. In all buildings, regardless of the HVAC-system, window opening was frequently used. The building with mechanical exhaust air ventilation (Abraham Wetter Street), which represents the current building practice showed the weakest results in ventilation and indoor air quality. Here, the indoor air humidity compared to the outdoor air humidity was approximately three times higher than in the other buildings. At night, the bedrooms had a maximum carbon dioxide concentration of 1400 ppm, which is about twice as high as the concentration in the other buildings. High carbon dioxide concentrations indicates that the concentration of other harmful contaminants may be high as well. High humidity may cause mould problems. In the building with mechanical exhaust air ventilation the exhaust air flows were typically only half of the recommended values as stated in the Finnish building code, whereas in the buildings with centralized supply and exhaust air ventilation systems the air flows corresponded to the default values in the code. Apartment based supply and exhaust air ventilation showed exhaust air flow rates that were about 20 % lower than the recommended values because the occupants were able to adjust the apartment based ventilation according to their demands. The quality of the indoor air was still as good as that with centralized ventilation systems. Energy consumption The building with apartment based ventilation (Herttoniemi Harbour) used the smallest amount of district heating energy. The district heating energy consumption in the building with apartment based ventilation building was 36 kwh/m³, whereas the annual consumption in the other buildings was 47-49 kwh/m³. If the exhaust air flows in the building with mechanical exhaust air ventilation would continuously have been as required by the building code, the district heating energy consumption would have been about 59 kwh/m³, which is 10 kwh/m³ more than the measured consumption. The apartment based ventilation saved district heating energy because the ventilation could be demand controlled, and also because the heat recovery was efficient. The electricity consumption of fans was the smallest in the buildings with mechanical exhaust air ventilation (Abraham Wetter Street) and apartment based ventilation (Herttoniemi Harbour). Energy and maintenance costs

680 Design and operation of HVAC systems The building with apartment based ventilation (Herttoniemi Harbour) had the best combination of good indoor climate and low energy costs. Even though the lowest energy bill was reported in the building with mechanical exhaust air ventilation (Abraham Wetter Street) the energy savings were a result of a ventilation rate well below the design value, and thus the indoor air quality was quite poor. The energy bill was 5 % higher in the building with apartment based ventilation and 10-30 % higher in the buildings with centralized supply and exhaust air ventilation. The difference between the lowest and highest energy bill was 0.24 /m²/month (20 000 per year). The total maintenance costs were lowest with exhaust air ventilation (0.048 /m²/month), whereas with centralized ventilation the costs were 0.053-0.075 /m²/month and with apartment based ventilation the cost were 0.083 /m²/month. CONCLUSIONS The research shows that the inherent problems with mechanical exhaust air ventilation systems have not been solved. The main problem is that the flow of outdoor air into building cannot be controlled in the rooms due to the uncontrollable pressure difference between indoor and outdoor air, which is caused by differences in indoor and outdoor air temperature, the stack effect (especially in multistorey buildings), wind, external and internal air leaks due to poor construction and open windows. Other problems are draught, dirty outdoor air entering the building and poor sound insulation. Multi-storey apartment buildings should have a well planned mechanical supply and exhaust air ventilation system with heat recovery in order to guarantee energy efficiency and a good and controllable indoor climate and air quality. The ventilation systems were left with many faults already during planning and implementation. Most of the faults were due to the malfunctioning of complicated regulators and control devices. The faults were not detected during delivery due to incomplete tests. Simpler systems, fewer mechanical components, avoiding to build parallel systems and cost reduction are central aims in functional housing engineering as well as in achieving a good and controllable indoor climate. The heat recovery from the exhaust air should be more efficient and the energy consumption of fans is too high and needs to be lowered. Without special training and detailed instructions, the maintenance staff is not able to control and maintain modern HVAC-systems and the proper functioning of the system cannot be guaranteed. According to the research results, ventilation heating is suitable in a modern well thermally insulated multi-storey building. The heat demand per apartment is so low that it is unnecessary to build a separate heat distribution system inside each apartment. Ventilation, however, is always inevitable. The building with ventilation heating was heated with heating coils in the supply air ducts in each apartment. Here, the supply air flows can normally be dimensioned according to the ventilation need because the heat demand is so low. ACKNOWLEDGEMENTS

Proceedings of Healthy Buildings 2000, Vol. 2 681 The comparison study was conducted in co-operation with the Housing Production Bureau of Helsinki, Roihuvuoren Kiinteistöt Oy (the service company), consulting engineers, manufacturers of heating and ventilation equipment and the Technical Research Centre of Finland. The study was funded by the Housing Production Bureau of Helsinki, the Technical Research Centre of Finland and the Technology Development Centre of Finland (TEKES). REFERENCE 1. Laine, J., Karjalainen, S. & Saari, M. A comparative HVAC-study of multi-storey apartment buildings by the Housing Production Bureau of Helsinki City (in Finnish), 1998. 60 p. + app. 75 p.