THE WALL-MOUNT TM HEAT PUMPS - (HZ) Models: WH2 to WH2 Hz Heating Capacities:, to 5, BTUH Cooling Capacities:, to 5, BTUH Green Refrigerant R-A The Bard Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements. Engineered Features Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. Most models feature multispeed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standard on all models. Heat Pump Compressor: Scroll Compressors are standard on all ½ to 5 ton models. Eliminates need for crankcase heater. Phase Rotation Monitor: Standard on all phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. R-A Refrigerant: Designed with R-A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 2 EPA requirements. Liquid Line Filter Drier: Standard on all units. Protects system against moisture. Galvanized 2 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on, beige textured enamel, which allows it to withstand hours of salt spray tests per ASTM B7-. Foil Faced Insulation: Standard on all units. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or toggle disconnect switch. Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages are factory or field installed for all ½ through 5 ton models. Features easy slide-in field assembly with various BTUH outputs. Condenser Fan and Motor Shroud Assembly: Slide out for easy access. Filter Service Door: Separate service door provides easy access for filter change. One Inch, Disposable Air Filters: Are standard equipment. Optional one inch washable filters available and filter racks permit the addition of 2" pleated filter. Factory or field installed. Solid State Electronic Heat Pump Control: Provides efficient, or minute defrost cycle. A thermistor sensor, speed up terminal for service and minute defrost override are standard on the electronic heat pump control. High & Low Pressure Switches are Auto- Reset: Standard on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Five Minute Compressor Time Delay: Short cycle protection is standard. Built into the heat pump control. Emergency Heat Circuit: Permits continuous operation of the system. Barometric Fresh Air Damper: Standard on all units. Allows up to % outside fresh air. Built-in Circuit Breakers: Standard on all electric heat versions of single and three phase (2/2 volt) equipment. Toggle disconnects are standard on all electric heat versions of three phase ( volt) equipment. Slope Top: Standard feature for water run-off. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Top Rain Flashing: Standard feature on all models. Ventilation System Packages All packages are designed to meet your specific ventilation requirements utilizing one of six ventilation options for the product. The ventilation package is mounted within the unit eliminating the need for an exterior mounted hood or damper assembly on the unit. All assemblies can be factory installed, installed in the field at time of installation or as a retrofit system after installation. Standard - Barometric Fresh Air Damper Optional - Motorized Fresh Air Damper Optional - Blank off Plate Optional - Commercial Room Ventilator w/exhaust CRV - Spring Return CRVP - Power Return Optional - Economizer with Exhaust Optional - Energy Recovery Ventilator Complies with efficiency requirements of ASHRAE/IESNA.-2. Certified to ANSI/ARI Standard -2 for SPVU (Single Package Vertical Units). Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL 5/CSA 22.2 No. 2-5, Fourth Edition. Commercial Product - Not intended for Residential application. Form No. S- Supersedes S- Page of
Capacity and Efficiency Ratings MODELS WH2 W2H2 WH2 WH2 W2H2 WH2 WH2 Cooling BTUH, 2, 2,, 2,, 5, EER.5..2.... High Temp Heating (7F) BTUH, 2, 2, 5, 2,, 5, COP....... Low Temp Heating (7F) BTUH,, 7, 2,, 2, 2, COP. 2. 2. 2. 2. 2. 2. Capacity is certified in accordance with ANSI/ARI Standard -2. EER = Energy Efficiency Ratio, COP = Coefficient of Performance and are certified in accordance with ANSI/ARI Standard -2. Specifications -/2 through Ton MODELS WH2-A W2H2-A W2H2-B W2H2-C WH2-A WH2-B WH2-C WH2-A WH2-B WH2-C Electrical Rating Hz 2/2-2/2-2/2 - - 2/2-2/2 - - 2/2-2/2 - - Operating Voltage Range 7-7- 7- -5 7-7- -5 7-7- -5 Compressor--Circuit A Voltage 2/2 2/2 2/2 2/2 2/2 2/2 2/2 Rated Load Amps.2/7. 2.7/5.2./.. 2./../.7 5.5.7/../2. 5.5 Branch Circuit Selection Current. 5.2...2. 5.7... Lock Rotor Amps / / 5/5 2 77/77 7/7 2/2 / Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Fan Motor & Condenser Fan Motor--HP--RPM /5 - /5 - /5 - /5 - /5 - /5 - /5 - /5 - /5 - /5 - Fan Motor--Amps.2.2.2..5.5..5.5. Fan--DIA/CFM " - " - " - " - 2" - 2 2" - 2 2" - 2 2" - 2 2" - 2 2" - 2 Blower Motor & Evap. Blower Motor--HP-RPM-SPD /--2 /-- /-- /--2 /--2 /--2 /--2 /--2 /--2 /--2 Blower Motor--Amps.... 2.2 2.2. 2.2 2.2. CFM Cooling & E.S.P. w/filter (Rated-Wet Coil) -. -. 2 -.2 -.2 -. -. -. -. -. -. Filter Sizes (inches) STD. x x x x x x x x Shipping Weight --LBS. x x x x x x x x x x x x Specifications -/2 through 5 Ton MODELS W2H2-A W2H2-B W2H2-C WH2-A WH2-B WH2-C WH2-A WH2-B WH2-C Electrical Rating Hz 2/2-2/2 - - 2/2-2/2 - - 2/2-2/2 - - Operating Voltage Range 7-7- -5 7-7- -5 7-7- -5 Compressor--Circuit A Voltage 2/2 2/2 2/2 2/2 2/2 2/2 Rated Load Amps./2.5./.5..5/2.2./.7. 2.5/. 2./5. 7. Branch Circuit Selection Current 2... 2.. 7. 2. 5.7 7. Lock Rotor Amps 7/7 / / / / / Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Fan Motor & Condenser Fan Motor--HP--RPM-SPD / - - 2 / - - 2 / - - 2 / - - 2 / - - 2 / - - 2 / - - 2 / - - 2 / - - 2 Fan Motor--Amps 2.5 2.5. 2.5 2.5. 2.5 2.5. Fan--DIA/CFM 2" - 2 2" - 2 2" - 2 2" - 2 2" - 2 2" - 2 2" - 2 2" - 2 2" - 2 Blower Motor & Evap. Blower Motor--HP-RPM-SPD /2-7-2 /2-7-2 /2-7-2 /2-7-2 /2-7-2 /2-7-2 /2-7-2 /2-7-2 /2-7-2 Blower Motor--Amps......... CFM Cooling & E.S.P. w/filter (Rated-Wet Coil) -. -. -. 55 -.2 55 -.2 55 -.2 7 -. 7 -. 7 -. Filter Sizes (inches) STD. 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x Shipping Weight --LBS. 55 55 55 55 55 55 5 5 5 Form No. S- Supersedes S- Page 2 of
Ventilation System Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the factory, or field-installed at a later date. BAROMETRIC FRESH AIR DAMPER - BFAD STANDARD The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door and allows outside ventilation air, up to % of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. Adjustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required. Barometric Fresh Air Damper Motorized Fresh Air Damper BLANK OFF PLATE - BOP OPTIONAL A blank off plate is installed on the inside of the service door. It covers the air inlet openings, which restricts any outside air from entering the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. MOTORIZED FRESH AIR DAMPER - MFAD OPTIONAL The motorized fresh air damper is internally mounted behind the service door and allows outside ventilation air, up to % of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The two position damper can be fully open or closed. The damper blade is powered open by a 2VAC motor with spring return on power loss. The damper can be controlled by indoor blower operation or can be field connected to be managed based on building occupancy. NOTE: The above vent systems are intake only without built-in exhaust capability. Building will likely require separate field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. Balancing dampers in the return air grille may be required to achieve specified amount of outdoor air intake. COMMERCIAL ROOM VENTILATOR - CRV OPTIONAL The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to 5% of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper. Commercial Room Ventilator The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. Two versions available (except on.5 and 2-Ton models). The CRV and CRVS are power open - spring return on power loss, and CRVP is power open and power close. Complies with ANSI/ASHRAE Standard 2. Ventilation for Acceptable Indoor Air Quality. Economizer ECONOMIZER ECONWM-Series OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. ECONWMT Equipment Building versions have extended " air intake hood to deliver up to % of cooling rated airflow. ECONWMS Standard versions have " air intake hood to deliver up to % of cooling rated airflow. Standard Features: Fully modulating Honeywell Direct Drive Hi-Torque Actuator No linkage required Simple single blade design Positive shut-off with non-stick gaskets Electronic DB and/or Enthalpy sensors depending upon version Honeywell JADE electronic economizer module with precision settings and diagnostics DB or Enthalpy economizer versions available WALL-MOUNT ENERGY RECOVERY VENTILATOR - ERVF OPTIONAL The wall-mount energy recovery ventilator (ERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by ANSI/ASHRAE Standard 2.. The ERV allows from 2 to 5 CFM (depending upon model) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 7% during summer and % during winter conditions. Energy Recovery Ventilator The ERV consists of a unique rotary energy recovery cassette that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The ERV is designed to be internally mounted behind the service door in the W**A, W**H or W**L model wall-mount units. It can be built-in at the factory or field installed as an option. ERVF-* and ERVF-*5 can be independently adjusted for intake and exhaust rates. Form No. S- Supersedes S- Page of
Commercial Room Ventilator Performance Data - CRV-2 W & W2 TOTAL AND VENTILATION AIRFLOW 7 5 Total Air ESP Total Air.5 ESP Total Air. ESP Vent Air ESP Vent Air.5 ESP Vent Air. ESP Airflow (cfm) 2 A B C D E F Vent Position Commercial Room Ventilator Performance Data - CRVS- and CRVP- W & W HIGH SPEED TOTAL AND VENTILATION AIRFLOW W & W LOW SPEED TOTAL AND VENTILATION AIRFLOW 2 7 7 5 Total Air ESP Total Air.5 ESP Total Air. ESP Vent Air ESP Vent Air.5 ESP Vent Air. ESP 5 Airflow (cfm) Airflow (cfm) 2 2 A B C D E F Vent Position A B C D E F Vent Position Total Air ESP Total Air.5 ESP Total Air. ESP Vent Air ESP Vent Air.5 ESP Vent Air. ESP Form No. S- Supersedes S- Page of
Commercial Room Ventilator Performance Data - CRVS-5 and CRVP-5 2 2 7 5 2 7 5 W2 & W HIGH SPEED TOTAL AND VENTILATION AIRFLOW W HIGH SPEED TOTAL AND VENTILATION AIRFLOW Total Air ESP Total Air.2 ESP Total Air. ESP Vent Air ESP Vent Air.2 ESP Vent Air. ESP 22 2 2 7 5 2 7 5 Airflow (cfm) 2 A B C D E F Vent Position 2 A B C D E F Vent Position W2 & W LOW SPEED TOTAL AND VENTILATION AIRFLOW W LOW SPEED TOTAL AND VENTILATION AIRFLOW 7 5 2 7 5 2 A B C D E F Vent Position Total Air ESP Total Air.2 ESP Total Air. ESP Vent Air ESP Vent Air.2 ESP Vent Air. ESP Total Air ESP Total Air.2 ESP Total Air. ESP Vent Air ESP Vent Air.2 ESP Vent Air. ESP Airflow (cfm) Airflow (cfm) 5 2 7 5 2 A B C D E F Vent Position Total Air ESP Total Air.2 ESP Total Air. ESP Vent Air ESP Vent Air.2 ESP Vent Air. ESP Airflow (cfm) Form No. S- Supersedes S- Page 5 of
Performance and Application Data- ERVF-*2 SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS DB/2 WB) Ambient O.D. VENTILATION RATE -- CFM 2% EFFICIENCY VENTILATION RATE -- 2 CFM % EFFICIENCY VENTILATION RATE -- 2 CFM % EFFICIENCY DB/WB F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL 5 7 5 7 2 2 2 2 2 22 727 727 727 727 727 727 5 5 5 5 5 2 5 2 2 2 2 2 2 7 5 5 5 7 5 5 5 5 5 5 5 5 2 7 57 727 7 72 72 72 72 72 72 72 7 55 2 2 2 2 2 2 2 2 2 5 5 5 5 5 5 5 5 5 5 5 2 2 2 2 2 2 2 5 2 5 5 7 5 5 5 5 5 5 5 5 5 5 7 5 7 57 727 7 5 5 5 5 5 5 5 57 5 2 5 5 2 2 2 2 2 2 2 72 2 7 5 5 2722 2722 2722 2722 2722 2722 2722 2 2 77 7 5 5 5 5 5 5 5 5 5 5 7 2 7 5 7 7 57 727 7 25 7 225 225 225 225 225 225 225 5 5 5 2 2 2 2 2 2 2 2 5 5 2 2 2 2 2 2 2 7 5 7 5 5 27 27 27 27 27 27 27 5 2 7 5 7 7 7 7 7 7 7 27 572 57 727 7 22 22 22 22 22 22 22 5 2 7 5 5 5 5 5 5 5 2 25 5 5 2 2 2 2 2 2 2 7 5 5 7 2 7 5 2 5 5 5 5 5 5 55 7 5 5 7 7 7 7 7 557 2 727 7 2 2 2 2 2 2 5 5 5 2 57 5 5 5 5 277 5 7 5 2 2 5 5 5 5 7 2 7 2 5 5 5 5 ERVF-*2 2-Ton Winter Heating Performance Ambient O.D. CFM 7% EFF. (INDOOR DESIGN CONDITIONS 7 F DB) VENTILATION RATE 2 CFM % EFF. 2 CFM % EFF. DB/ F VLT HR VL VLT HR VL VLT HR VL 5 5 5 2 27 72 2 2 2 2 5 55 5 27 5 5 27 2 22 77 5 5 5 2 2 7 5 5 5 55 5 5 2 5 2 72 5 2 555 5 5 257 55 7 22 57 72 2 72 72 2 5 27 5 5 2 27 72 77 2 2 5 5 2 2 5 5 5 2 2 2 22 5 5 5 2 5 5 5 27 5 575 7 7 7 2 2-5 2 5 5 2 55 2 22-2 5 5 5 72 7 LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent Form No. S- Supersedes S- Page of
Performance and Application Data- ERVF-* SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS DB/2 WB) Ambient O.D. VENTILATION RATE -- CFM 2% EFFICIENCY VENTILATION RATE -- 2 CFM % EFFICIENCY VENTILATION RATE -- 2 CFM % EFFICIENCY DB/WB F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL 5 7 5 2 2 2 2 2 2 22 55 5 5 5 5 5 5 72 2 7 7 7 7 7 2 7 5 5 5 5 5 2 7 5 2 72 2 7 22 77 2 5 2 7 7 7 7 7 7 7 727 2 57 5 5 5 5 5 5 5 5 5 5 2 5 2 7 7 7 7 7 7 7 7 7 7 7 5 7 5 2 2 7 22 7 5 5 5 5 5 5 5 227 577 7 2 5 2 72 72 72 72 72 72 72 575 2 2 57 2 2 2 2 2 2 2 52 2 5 2 5 5 5 5 5 5 5 5 2 7 7 5 5 5 5 5 5 5 77 2 5 7 5 2 2 2 5 7 22 7 2 2 2 2 2 2 2 7 25 2 5 2 5 5 5 5 5 5 5 5 27 5 2 57 22 5 2 5 2 5 5 5 5 5 5 5 5 7 22 7 7 22 22 22 22 22 22 22 77 5 2 5 7 5 2 2 2 2 2 2 2 2 27 7 7 22 7 272 272 272 272 272 272 272 2 5 2 5 2 5 5 5 5 5 5 5 5 2 5 2 57 22 22 22 22 22 22 22 255 7 5 2 27 27 27 27 27 27 27 5 2 2 7 7 5 5 5 5 5 5 5 5 2 7 5 7 2 2 2 2 2 2 2 2 22 7 2 5 555 2 5 2 7 5 5 5 5 5 77 7 2 57 5 2 2 2 2 2 7 5 2 2 22 5 5 5 5 5 5 5 2 7 55 77 77 77 77 77 7 5 5 7 5 7 7 7 2 7 2 2 7 2 7 57 5 57 5 2 22 2 22 55 55 ERVF-* -Ton Winter Heating Performance Ambient O.D. CFM % EFF. (INDOOR DESIGN CONDITIONS 7 F DB) VENTILATION RATE CFM 7% EFF. CFM 77% EFF. DB/ F VLT HR VL VLT HR VL VLT HR VL 5 2 2 5 5 2 5 2 2 5 2 2 27 27 2 55 2 5 2 5 2 5 2 72 55 5 5 5 22 5 27 7 2 5 55 2 72 2 5 27 27 5 7 2 7 2 5 7277 27 72 2 2 7 7 2 5 575 2 7 5 275 2 2 2 5 5 22 5 5 5 5 27 72 5 5 72 5 5 2 2 55 2 27 72 5 2 2 72 2 7 57 5 5 7 2 22 257 7 57 55 7-5 2 2 2 27 2 55 5-5 2 2 2 7 2 2 LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent Form No. S- Supersedes S- Page 7 of
Performance and Application Data- ERVF-*5 Ambient O.D. VENTILATION RATE -- CFM 2% EFFICIENCY SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS DB/2 WB) VENTILATION RATE -- 2 CFM % EFFICIENCY VENTILATION RATE -- 2 CFM % EFFICIENCY DB/WB F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL 5 5 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 25 5 5 5 25 2 5 25 2 72 72 5 25 2 72 72 5 25 2 25 2 2 2 2 2 5 5 5 72 72 72 72 72 72 72 72 72 72 2 2 2 2 22 27 7 22 2 27 5 72 5 22 22 2 2 77 77 2 77 77 2 2 7 7 2 5 5 2 27 57 2 27 77 77 77 77 77 77 77 77 7 7 7 7 7 5 5 5 5 5 2 27 57 25 5 7 7 57 2 2 77 7 7 272 2 27 77 2 77 2 2 77 2 2 77 2 2 77 2 5 5 77 2 5 2 2 5 5 5 5 5 5 2 2 2 2 577 2 772 2 77 2 2 2 2 222 7 2 2 5 2 5 5 77 5 7 2 2 77 5 7 55 55 77 5 7 77 5 7 272 272 5 7 2 7 2 2 2 2 2 2 55 55 55 55 55 272 272 272 272 272 7 2 22 5 7 5 77 27 7 2 2 557 2 7 2 72 72 2 25 2 25 2 25 2 25 2 2 25 25 2 25 25 72 72 72 2 2 2 2 2 2 2 2 2 5 2 2 5 5 7 5 2 5 72 7 5 2 5 25 25 57 57 557 527 527 57 557 57 557 57 557 27 27 57 557 5 557 527 527 527 527 527 27 27 27 27 27 5 5 5 5 7 5 22 7 2 557 ERVF-5* 5-Ton Winter Heating Performance Ambient O.D. 5 CFM % EFF. (INDOOR DESIGN CONDITIONS 7 F DB) VENTILATION RATE CFM % EFF. CFM 2% EFF. DB/ F VLT HR VL VLT HR VL VLT HR VL 5 2 2 5 2 2 22 72 5 2 77 2 7 5 55 72 52 5 2 5 5 5 72 777 5 5 5 5 72 2 2 2 2 5 5 2 2 2 72 77 5 7 2 2 2 2 2 55 2 22 7 2 27 2 27 7 7 2 72 5 5 22 2 2 2 2 2 2 5 27 2 5 222 22 72 2 2 2 22 52 2 7 5 5 5 272 2 22 2 72 7 2 272 25 22 57 22 5 2-5 5 2 72 2 577 2 2 7-777 2 22 5 2 2 LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent Form No. S- Supersedes S- Page of
NOTES Form No. S- Supersedes S- Page of
Electrical Specifications Standard Heat Pumps MODEL WH2-A, AZ A A W2H2-A, AZ A A W2H2-B, BZ B W2H2-C, CZ C WH2-A, AZ* A5* A* WH2-B, BZ* B B* WH2-C, CZ* C C* l C5 WH2-A, AZ* A5 A* m A5 WH2-B, BZ* B B* l B5 WH2-C, CZ* C C* l C5 W2H2-A, AZ A A5 A m A5 W2H2-B, BZ B B l B5 W2H2-C, CZ C C l C5 WH2-A, AZ A A5 A m A5 m A2 WH2-B, BZ B B l B5 l B WH2-C, CZ C l C5 WH2-A, AZ A5 A m A5 m A2 WH2-B, BZ B l B5 l B WH2-C, CZ C l C5 These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical Code (latest version), Article for power conductor sizing. CAUTION: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table regarding Ampacity Adjustment Factors when more than three () conductors are in a raceway. Maximum size of the time delay fuse or circuit breaker for protection of field wiring conductors. Maximum KW that can operate with the heat pump on is KW. Full heat available during emergency heat mode. Maximum KW that can operate with the heat pump on is KW. Full heat available during emergency heat mode. n Based on C copper wire. All wiring must conform to the National Electrical Code and all local codes. * Available factory-built only with top outlet supply as an option. IMPORTANT: Form No. S- Supersedes S- Page of Rated Volts & Phase 2/2-2/2-2/2- - 2/2-2/2- - 2/2-2/2- - 2/2-2/2- - 2/2-2/2- - 2/2-2/2- - No. Field Power Circuits or 2 or 2 or 2 or 2 or 2 or 2 or 2 or 2 or 2 or 2 or 2 2 or 2 or 2 or 2 or 2 2 j Minimum Circuit Ampacity 7 5 2 5 7 5 2 2 5 7 5 2 2 2 55 2 5 5 2 2 2 57 2 2 5 5 22 2 2 7 5 2 7 5 5 N/A 27 27 7 2 55 55 N/A 5 2 2 Single Circuit k Maximum External Fuse or Ckt. Brkr. 2 5 7 2 5 5 5 5 5 2 5 5 5 5 7 5 5 5 5 7 5 5 N/A 2 N/A 2 n Field Power Wire Size 2 2 2 2 N/A 2 2 N/A 2 n Ground Wire 2 j Minimum Circuit Ampacity k Maximum External Fuse or Ckt. Breaker Dual Circuit n Field Power Wire Size n Ground Wire Size Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B 2 5 2 5 2 5 2 While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses & conductor wires in accordance with the National Electrical Code & all local codes. 55 55 7 7 7 5 2 2 2 5 5 5 5 5 5 N/A 2 2 5 2 N/A 2 2
Electrical Specifications Dehumidification Models MODEL Rated Volts & Phase No. Field Power Circuits j Minimum Circuit Ampacity Single Circuit k Maximum External Fuse or Ckt. Brkr. l Field Power Wire Size l Ground Wire j Minimum Circuit Ampacity k Maximum External Fuse or Ckt. Breaker Dual Circuit l Field Power Wire Size l Ground Wire Size Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B W2H2DA, AZ A A 2/2- or 2 2 5 5 7 2 5 W2H2DB, BZ B 2/2-7 5 2 2 2 W2H2DC, CZ C - 2 2 5 WH2DA, AZ A5 A 2/2- or 2 27 7 5 2 WH2DB, BZ B B 2/2-7 7 5 WH2DC, CZ C C - 2 2 2 5 WH2DA, AZ A5 A 2/2- or 2 5 2 55 2 WH2DB, BZ B B 2/2-2 2 5 5 WH2DC, CZ C C - 2 2 5 W2H2DA, AZ A5 A 2/2- or 2 or 2 2 7 2 5 5 W2H2DB, BZ B B 2/2-2 55 5 W2H2DC, CZ C C - 2 27 2 2 2 WH2DA, AZ A5 A 2/2- or 2 or 2 5 2 5 WH2DB, BZ B B 2/2-2 7 5 5 5 WH2DC, CZ C - 27 2 2 2 WH2DA, AZ A5 A 2/2- or 2 or 2 7 2 WH2DB, BZ B 2/2-2 55 WH2DC, CZ C - 5 2 2 2 2 These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical Code (latest version), Article for power conductor sizing. CAUTION: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table regarding Ampacity Adjustment Factors when more than three () conductors are in a raceway. Maximum size of the time delay fuse or circuit breaker for protection of field wiring conductors. Based on C copper wire. All wiring must conform to the National Electrical Code and all local codes. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses & conductor wires in accordance with the National Electrical Code & all local codes. Form No. S- Supersedes S- Page of
Indoor Blower Performance - CFM at 2 or Volts ESP in H 2 O High Speed WH2 W2H2 WH2 / WH2 W2H2 / WH2 WH2 Low Speed Single Speed High Speed Low Speed High Speed Low Speed High Speed Low Speed. 2/ /7 2/ 5/5 5/5 5/ 5/ 22/2 /5. /5 75/ /5 /27 /5 77/5 55/5 2/ 5/.2 5/ 7/5 5/ / /5 5/55 5/ 2/ 5/2. 2/75 / 2/75 / 55/ 5/ 5/ /7 -/-. 75/5 5/55 75/5 / /5 7/ / 7/ -/-.5 5/55 5/ 5/55 5/7 -/- /5 -/- 5/ -/- Above data is with " standard throwaway filter and " washable filter. For optional 2" pleated filter - reduce ESP by.5 in. See installation instructions for maximum ESP information on various KW applications. Speeds marked bold above are Factory Connected. Electric Heat Table----Refer to Electrical Specifications for Availability by Unit Model Nominal KW KW At 2V () At 2V () At V (2) At V (2) -Ph Amps -Ph Amps Btuh KW -Ph Amps -Ph Amps...7,..,2 5. 5. 2. 7,5.. 2,7... 2,7.5 2.5 5,5. 7.2 2,7 5..,... 27,. 2. 2,7.. 2.7,77..7 2,..,77.2. 2,2...7, 7.5.,5 5. 5. 2.5. 5,5. 5..2, 5.. 5,5. 7. 7,...,.5 7.5,7. 2.7,.5 2. 5,5 2. 2..,2 5. 72. 5,5 () These electric heaters are available in 2/2V units only. (2) These electric heaters are available in V units only. Btuh KW -Ph Amps Btuh KW -Ph Amps Btuh Heater Packages - Field Installed Designed for adding Electric Heat to KW Units Circuit Breaker Standard on 2/2V Models Air Conditioner Models -A Models 2/2- ETL US & Canada Listed Toggle Disconnect Standard on V Models -B Models 2/2- -C Models - Heater Model # KW Heater Model # KW Heater Model # KW WH2 EHWH2A-AB EHWH2A-AB N/A N/A W2H2 EHW2H-AB EHW2H-AB EHW2H-BB EHWH2B-C WH2 EHWH-A5B EHWH-AB 5 EHWH-BB EHWH-BB EHWCA-C EHWCA-C EHWHA-C5 * 5 WH2 EHWH-A5B EHWH-AB EHWH-A5B * 5 5 EHWH-BB EHWH-BB EHWH-B5B * 5 EHWCA-C EHWCA-C EHWHA-C5 * 5 W2H2 EHWH-AB EHWH2-A5B EHWH2-AB EHWH2-A5B * 5 5 EHWH5-BB EHWH5-BB EHWH5-B5B * 5 EHWH2-C EHWH5A-C EHWH5A-C5 * 5 WH2 EHWH-AB EHWH2-A5B EHWH2-AB EHWH2-A5B * EHWH-A2B * 5 5 2 EHWH5-BB EHWH5-BB EHWH5-B5B * EHW5H-BB * 5 EHWH5A-C EHWH5A-C5 * 5 WH2 EHWH-A5B EHWH-AB EHWH-A5B * EHWH-A2B * 5 5 2 EHWH5-BB EHWH5-B5B * EHW5H-BB * 5 EHWH5A-C EHWH5A-C5 * 5 NOTE: Field installed heater packages are not approved for use with top supply opening models. * Not available for dehumidification models. Form No. S- Supersedes S- Page 2 of
Cooling Application Data - Outdoor Temperature F Model WH2 W2H2 WH2 WH2 W2H2 WH2 WH2 Return Air (DB/WB) /2 /7 5/72 /2 /7 5/72 /2 /7 5/72 /2 /7 5/72 /2 /7 5/72 /2 /7 5/72 /2 /7 5/72 Cooling Capacity F F 5 F F 5 F F 5 F F 5 F 2 F 7,,,, 22,,2 27, 2,7 2, 2,,5 2,5, 2,, 2,,5 2, 5, 2,,2 27,7 5,5 2,,5,2, 5, 5,,,2,,5 7, 2,, 5,,, 2,5 72,2,5 7,,,5, 2,7,,, 27,,,,7, 2,2, 2,7, 2,, 2, 7,5 27,, 27,, 5, 7,5, 55,,,,2 5, 7, 5,, 5, 2,7 5,2,,2 2,,2, 7,, 2,,5 2,,,, 2,, 2, 2,7 2, 2,, 2,5, 27,, 27, 2, 27,2,, 5,5,7,,,5 7,2,, 5,7 7,,, 57,7,2,, Below 5 F, unit requires a factory or field installed low ambient control. Return air temperature F. 5,,2 7,2,2,5, 2,, 2,, 27,,2 27, 2,, 2,, 22,, 2, 5,7 2,, 2,,7,2,7,2,, 2,,2 7,,2 5,,,, 5,,,2,, 2,, 2,, 2,7 2, 7,7 2, 7, 2, 7,5 2, 22, 2, 22,, 22,2,2,, 2,,5,, 2, 2, 2,7,7 2,, 5,, 5, 5,, 7,, 5,,,,,5 2, 5,7 2, 7,2 2,2, 7, 22, 7, 2,5, 2,7 2,7 2,7 22,, 2, 2,,2,,, 2,,,7, 2,2,,2,,,,,5,,,,, 5, 7, 2, 2,, 2,,,,, 2,5 7, 2,2,2 2, 2,2 27, 2,7 2, 2,7 27,5 2,5 2,, 5, 2,,2,,2, 2,,,, 2,, 5,7 2,7 2, 7,,7 7, 5,,,7,,,,,2 7,, 2,7, 22, 5, 22,2 2, 2, 2, 2,, 2, 2,, 2,, 2, 2,,,,, 2,, 2,5,5,,,5,7 5, 7, 7, 5,,7,,,,,7,7,7 5,7 2,, 2, 5, 2,,,2 2, 2,5, 2, 2, 2, 2,, 22,,,2 7,,, 2, 2,,7,,,, 7,,7,,,,,, 2,,2 2,5,2, 5,,, 2,2,5,, 2, 2,,, 2,5 22, 2, 2, 2,5 2,2 2, 2,,2, 7, 2,,2,2, 2,, 2,2,5,, 5,,, Capacity Multiplier Factors % of Rated Airflow - Rated + Total BTUH Sensible BTUH..5...2.5 Form No. S- Supersedes S- Page of
Heating Application Rating and Outdoor Temperature F * MODEL 5 5 2 5 5 5 55 F 5 F WH2 W2H2 WH2 WH2 W2H2 WH2 WH2 BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP BTUH WATTS COP,7,., 2,.2,2 2,.22, 2,. 5,,. 5,,5.,,2.,,5., 2,. 2,2 2,5. 5, 2,5.5,2,5.5,,2.5 2,2,.55 7,,.,7 2,.,2 2,5. 7, 2,. 2,,2.7 2,,7. 2,,.7,5,5.2, 2,5.,2 2,5. 2, 2,5 2. 2,,. 2,,7.5,,5.,5,5., 2,7. 7,7 2, 2. 2,5 2,7 2.,,7. 2,5, 2. 2,,2 2.5,2,5.5,7 2,7., 2, 2.2 22, 2,7 2.2 2,,7 2. 27,,7 2. 2,, 2. *7 F DB indoor return air at rated CFM includes defrost operation below 5.,,5 2. 5, 2,7 2., 2,5 2.2 2, 2,7 2.2 2,7,7 2.7 2,,77 2.,,5 2.,7,5 2.2 5,5 2,7 2. 2, 2,5 2. 2, 2,7 2. 27,, 2.2 2,,77 2.,, 2.,,5 2.55, 2,27 2.7 2, 2,7 2.5 2,5, 2.7,5, 2. 5,2, 2.5 2,2,5 2.55 5,, 2.5 22, 2, 2. 27,7 2, 2.,2,22.,, 2.,5,.2 5,7 5,5 2.5 7,,., 2,2.,2 2,.,,.2,7,2.2 5,,.27 5,2 5,7.,7,.27 2,7 2,. 2,2 2,.2,,5.,,2.7,,. 5, 5,2.,,7. 2, 2,5.,2 2,.,,.55,,. 5,,22., 5,. 2,2,72.2, 2,5.7,2 2,.5,,5.,2,7. 5,,27.77 7,2 5,. Form No. S- Supersedes S- Page of
Clearances Required for Service Access and Adequate Condenser Inlet Airflow MODELS LEFT SIDE RIGHT SIDE WH2, W2H2, WH2, WH2 5" 2" W2H2, WH2, WH2 2" 2" Minimum Clearances Required to Combustible Materials MODELS SUPPLY AIR DUCT FIRST THREE FEET CABINET WH2, W2H2 " " WH2, WH2 /" " W2H2, WH2, WH2 /" " Refer to the Installation Manual for more detailed information. Dimensions of W-H Basic Unit for Architectural & Installation Requirements (Nominal) MODEL WIDTH (W) DEPTH (D) HEIGHT (H) SUPPLY RETURN A B C B E F G I J K L M N O P Q R S S2 T WH2 W2H2. 7. 7.5 7.... 5... 2.5 2. 2. 2. 27. 2.. 22..55 5. 2. 2. 5. WH2 WH2.2 7. 7.5 7. 27.. 27.... 7. 2. 2. 2. 27. 2.. 22.. 5. 2. 2. 5. W2H2 WH2 2. 22.2.. 2. 5. 2...5.. 2. 2.. 2..7. 2...... WH2 2. 22.2.. 2. 5. 2...5.. 2... 2..7..... 2.. All dimensions are in inches. Dimensional drawings are not to scale. W Built In Rain Hood Pitch Heater Access Panel Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) Hood for ERV and ECONWMS models only D 2 7. 2. 2. A I Side Wall Mounting Brackets (Built In) Top Rain Flashing Shipping Location E O. Supply Air Opening B 2. R S S 5. F G Filter Access Panel Ventilation Air Condenser Air Outlet Standard flush vent " door for non-erv/ Econ. models " Low Voltage Hood for Electrical ECONWMT Entrance models. High Voltage Electrical Entrance Cond. Air Inlet J C K H Optional Electrical Entrances L M P Return Air Opening S S2 S2 T Front View Side View Drain N Q Back View Bottom Installation Bracket MIS- Not used when ECONWMT Economizers installed. Filter access is through the ECONWMT hood. k Optional top outlet (factory installed only) in place of standard front supply air opening for WH and WH models only. Form No. S- Supersedes S- Page 5 of
Heat Pump Wall-Mount Model Nomenclature MODEL NUMBER l CAPACITY - ½ Ton 2-2 Ton - 2½ Ton - Ton 2 - ½ Ton - Ton - 5 Ton W H 2 A X X X X X E Models WH2, W2H2 WH2, WH2 W2H2, WH2, WH2 Description HEAT PUMP REVISION SPECIALTY PRODUCTS (Non-Standard) For KW and circuit breakers (2/2 volt) or toggle disconnects ( volt) applications, insert Z in the KW field of the model number. Insert D for dehumidification with hot gas reheat. Not available for Model WH. Reference Form 7-57 for complete details. Ventilation Options Factory Installed Code No. VOLTS & PHASE A - 2/2// B - 2/2// C - // VENTILATION OPTIONS (See Table Below) Field Installed Part No. Factory Installed Code No. Field Installed Part No. Factory Installed Code No. Field Installed Part No. Barometric Fresh Air Damper - Standard X BFAD-2 X BFAD- X BFAD-5 Blank-Off Plate B BOP-2 B BOP- B BOP-5 Motorized Fresh Air Damper M MFAD-2 M MFAD- M MFAD-5 Commercial Ventilator - Spring Return w/exhaust V CRV-2 V CRVS- V CRVS-5 Commercial Ventilator - Power Return w/exhaust P CRVP- P CRVP-5 Economizer - Standard Versions, Enthalpy m S ECONWMS-E2B k S ECONWMS-EB k S ECONWMS-E5B k Economizer - Equipment Bldg., Enthalpy n W ECONWMT-E2B k W ECONWMT-EB k W ECONWMT-E5B k Economizer - Equipment Bldg., DB Temp n T ECONWMT-T2B k T ECONWMT-TB k T ECONWMT-T5B k Energy Recovery Ventilator - 2 Volt l R ERVF-A2 R ERVF-A j R ERVF-A5 j Energy Recovery Ventilator - Volt l R ERVF-C2 o R ERVF-C j R ERVF-C5 j Door Kit for ERVF (Required) N/A WMDK2- l N/A WMDK- l N/A WMDK5- l Intake and exhaust can be independently adjusted. Insert color to match unit ("X" = Beige; "" = Buckeye Gray; etc.) WMDK Door Kit must be ordered in addition to ERVF Assembly & color matched to unit ("X" = Beige; "" = Buckeye Gray; etc.) Partial Full Flow (% of Rated Cooling CFM). All ECONWMS versions have " deep intake hood. Full Flow (% of Rated Cooling CFM). All ECONWMT versions have " deep intake hood. o W2H2 Only. Heat Pump Control Modules All Models KW j COLOR OPTIONS X - Beige (Standard) - White - Buckeye Gray 5 - Desert Brown - Dark Bronze FILTER OPTIONS X - inch Throwaway (Standard) W - inch Washable P - 2 inch Pleated (MERV ) CONTROL MODULES (See Chart Below) COIL OPTIONS X - Standard - Phenolic Coated Evaporator 2 - Phenolic Coated Condenser - Phenolic Coated Evaporator and Condenser SUPPLY AIR OUTLET X - Front (Standard) T - Top (on WH2 & WH2 Models) Low Pressure Control High Pressure Control j Low Ambient Control and Relay k Start Kit l Start Kit m Outdoor Thermostat n Factory Installed Code Field Installed Part STD STD X N/A STD STD E CMH- STD STD Q CMH-A STD STD R - - - STD STD S - - - STD STD T - - - STD STD Field Installed CMC-5 l STD STD Field Installed SK STD = Standard Equipment The high & low pressure controls are auto reset. Operating circuit includes a lockout feature and is resettable from the wall thermostat. All low pressure controls use a timed bypass circuit to prevent nuisance tripping during low temperature start-up. The low ambient control includes an 2- (fan relay) and permits cooling operation down to F. PTCR start kit can be used with all -A single phase models. Increases starting torque 2-x. Not used for -B or -C three phase models. Do not use if SK is used. Start capacitor and potential relay start kit can be used with all -A single phase models. Increases starting torque x. Not used for -B or -C three phase models. Do not use if CMC-5 is used. The outdoor thermostat is adjustable from F to 5 F. It is suitable for use as a compressor cut-off thermostat. NOTE: Standard heat pump control board has a 5-minute compressor anti-short cycle timer. Form No. S- Supersedes S- Page of Bard Manufacturing Company, Inc. Bryan, Ohio 5 www.bardhvac.com Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S February, Supersedes S-