1 Thru-the-wall AIR CONDITIONERS 2009 COOL ONLY HEAT PUMPS ELECTRIC HEAT
2 THRU-THE-WALL 27 sleeve Friedrich thru-the-wall air conditioners are ideal for new construction, retrofits and remodels 8,000 to 15,800 BTU/h COOLING 8,100 to 11,000 BTU/h HEATING EERs up to 10.5 cool only / heat pumps / cool w/electric heat The Most Energy Efficient Solid-side Air Conditioner Chassis installs into existing 27 sleeves DIGITAL CONTROLS FEATURE REMOTE CONTROL 24-HOUR TIMER MONEY SAVER FEATURE SMART FAN ANTIMICROBIAL FILTER 5 ENERGYSTAR models Sleeve Dimensions Friedrich WSC Sleeve Fedders A Sleeve Fedders B Sleeve* Height (inches) 16 3/4 16 3/4 16 3/4 Width (inches) Depth (inches) 16 3/4 16 3/4 19 3/4 Units are shown installed in WSC sleeve (sold and shipped separately) *Installation in Fedders B sleeve requires a baffle kit. See BAK accessory under accessories.
3 THRU-THE-WALL 26 sleeve universal fit THRU-THE-WALL units mount flush with exterior walls for a sleek appearance, as well as unobstructed window views. (Wallmaster WSC sleeve shown with architectural grille. Uni-fit grille has different appearance.) 8,000 to 13,000 BTU/h COOLING 3,850 to 11,200 BTU/h HEATING EERs up to 9.6 cool only, cool w/electric heat - Universal Fit for Easy Replacement Chassis installs into existing 26" sleeves DIGITAL CONTROLS FEATURE (cool only models) REMOTE CONTROL 12-HOUR TIMER MONEY SAVER FEATURE Sleeve Dimensions White- Friedrich USC Sleeve Amana Carrier (51S Series) Fedders/ Emerson/ Friedrich WSC Emerson/ Fedders GE/ Hotpoint Whirlpool Westinghouse/ Frigidaire/ Carrier (52F Series) Height (inches) 15 17/ /8 16 7/8 16 3/4 15 3/4 15 5/8 16 1/2 15 1/4 5 ENERGYSTAR models Width (inches) 25 7/ / / /8 25 1/2 Depth (inches) 16 23/ /8 18 5/8 16 3/4 or 19 3/ /8 17 1/8 or 23 16, 17 1/2 or 22 Units are shown without USC sleeve (USC sleeves sold and shipped separately)
4 27 Sleeve Exterior Grilles IMPORTANT: Installation Accessories (27 sleeve models only) DK / Drain Kit Installed at the back of the unit and allows for attachment to permanent condensate disposal system, if disposal is necessary or desired. SB / Sub Base Used as a base for the unit when it is desired to place the cord and receptacle within the installation, or simply as a base for the unit when mounted low in the wall. IDK / Internal Drain Kit New construction applications where a condensate drain system has been built into the wall interior. BAK / Baffle Adapter Kit Necessary when installing in a sleeve deeper than 16 3/4" deep, such as Fedders B sleeve (19 3/4" deep). 16 3/4" Fedders B 19 3/4 26 Sleeve Exterior Grilles STANDARD GRILLE Ships with USC sleeve REPLACEMENT GRILLE Ships with US/UE chassis IMPORTANT: Sleeve/Chassis Dimensions Model Height Width Depth WALLMASTER WSC Sleeve Chassis UNI-FIT Depth with Front Minimum Extension Into Room Minimum Extension Outside Thru-the-wall Finished Hole Height Width Max. Depth 16 3/4" 27" 16 3/4" 23" 7 1/2" 9/16" 17 1/4" 27 1/4" 15 5/16" 15 3/4" 26 1/2" 21" 22 USC Sleeve 15 1/2" 25 7/8" 16 3/4" 20 1/2" 1/2" 15 3/4" 26 1/8" 16 1/4" US Chassis 14 3/8" 24" 20 1/8" 3 3/4" UE Chassis 14 3/8" 24 5/8" 19 5/8" 3 1/2" IMPORTANT: 8 8 IMPORTANT: Sleeves are sold and shipped separately to accommodate new construction and replacement requirements
5 DIGITAL CONTROLS with REMOTE Commercial & Residential Applications When should you install a solid side sleeve? SOLID SIDE wall sleeve allows for installation in thick exterior walls where the installation of room air units with side vents would effect performance and may even void the warranty. ROOM AIR CONDITIONER Blocked side vents restrict air flow FRIEDRICH THRU-THE-WALL Solid-side sleeve (no side vents) can be installed flush with exterior wall.
6 Specifications ENERGY STAR models Model Cooling Capacity BTU/h Heating Capacity BTU/h Volts Rated Cooling Amps Cooling Watts Heating Amps Heating Watts Energy Efficiency Ratio EER Moisture Removal Pints/Hr. Room Side Air Circulation Sleeve Weight Lbs. Ship/Net WALLMASTER WS08B10A WSC 97/93 WS10B10A WSC 107/103 WS14B10A WSC 116/112 WS10B30A 10000/ / / / / WSC 105/101 WS13B30B 12500/ / / / / WSC 113/109 WS16B30A 15800/ / / / / WSC 123/119 WE10B33C 10000/ / / / / / / / WSC 107/103 WE13B33C 12500/ / / / / / / / WSC 115/111 WE16B33C 15800/ / / / / / / / WSC 125/121 WY10B33C 10100/ / / / / / / / WSC 111/107 WY13B33C 12500/ / / / / / / / WSC 120/116 UNI-FIT US08B10A USC 77/73 US10B10B USC 82/78 US10B30A 10000/ / / / USC 82/78 US12B10B USC 84/80 US12B30C 11500/ / / / USC 84/80 US14B30A 13000/ / / / USC 88/84 UE08A13B USC 77/73 UE10A33B 10000/ / / / / / / USC 82/78 UE12A33C 11500/ / / / / / / USC 84/80 WallMaster Heat Pump heating information (shown in red) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red) indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model. WALLMASTER HEAT PUMP HEATING PERFORMANCE Change-over from heat pump operation to resistance operation on models indicated is automatic at a preset outside ambient temperature of approximately 35 F. Calculate the heat loss of the space to be heated. As long as the heat loss does not exceed the resistance heating capacity rating of the unit, the heating performance will be satisfactory. Note: all models will produce condensate. If condensate disposal is desired, an optional drain kit is available. DEFROST CONTROL: Initiated at 20 F (outdoor coil temperature) and terminated at 43 F (outdoor coil temperature). During defrost, the compressor stops and the electric heat starts, then operates with the fan to maintain indoor comfort. Below 43 F, the unit remains in electric heat mode. During electric heat mode, the unit will achieve the following ratings: 11000/9100 BTU/h, 16.0/14.7 amps, and 3550/2950 watts. DEFROST DRAIN: Drain automatically opens at approximately 50 F to prevent condensate from freezing inside drain pan. Plug Face/ Circuit Rating WallMaster Model Number Uni-Fit Model Number Circuit Rating Breaker or T-D Fuse Plug Face (NEMA#) Power Cord Length (ft.) Wall Outlet Appearance WS08B10A, WS10B10A, WS14B10A US08B10A, UE08A13B US10B10B, US12B10B 125V - 15A 5-15P 6 WS10B30A, WS13B30B, WS16B30A US10B30A, US12B30C, US14B30A 250V - 15A 6-15P 4 WE10B33C, WE13B33C, WE16B33C, WY10B33C, WY13B33C UE10A33B, UE12A33C 250V - 20A 6-20P 4 Power cords are located on front left of WallMaster models and on front right of Uni-Fit models. As an ENERGY STAR partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR models ( ) meet the ENERGY STAR guidelines for energy efficiency. Friedrich Air Conditioning Co. P.O. Box 1540 San Antonio, TX (800) fax (210) TTW-09 (1-09) Printed in USA
26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.
T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R
Room Air Conditioners
Room Air Conditioners Commercial Quality Design TOUGH l DURABLE l COOL COOLING ONLY HEAT PUMP ELECTRIC HEAT Exceptional energy efficiency Simple to use electronics Remote control convenience Q U A L I
tough. durable. friedrich.
tough. durable. friedrich. ROOM AIR CONDITIONERS 2003 LINE EST. 1883 Dear Friedrich, I wanted to say thank you for producing a VERY durable room air conditioner. The other night, my daughter asked me to
SINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
ROOM AIR CONDITIONERS
ROOM AIR CONDITIONERS www.friedrich.com QUALITY COOLING ONLY HEAT PUMP ELECTRIC HEAT Rugged, commercial-grade components. Heavy gauge steel cabinets. State-of-the-art manufacturing. Engineered to perform
PACKAGED TERMINAL AIR CONDITIONERS
PACKAGED TERMINAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT www.friedrich.com 3 fan speeds heating and cooling FEATURES Comfort & Dehumidification Maintenance & Installation Features
SPECIFICATIONS. Cooling Capacity BTUH 5,200. Approx. Sq. Ft. Cooling 100-150 EER 9.7 Heating Capacity BTUH N/A (electric)
Table of Contents The full range of Comfort-Aire products for the Room Air market is presented in this catalog. Products are grouped into categories for your convenience and each section is color-coded,
Single Package Vertical Air Conditioners. Vert-I-Pak
Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better
Installation Instructions
READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle
KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU
GENERAL PURPOSE (ORDINARY) LOCATION Custom Controls provides the petro-chemical and offshore industries with HVAC equipment of the highest quality and reliability on the market at an economical price.
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Single Zone LCD Thermostat Operating Instructions
Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
ROOM AIR CONDITIONERS
ROOM AIR CONDITIONERS Q U A L I T Y WINDOW / TRU-TE-WALL / PORTABLE CONTENTS WIC PRODUCT IS BEST FOR YOUR NEEDS? PAGE 3 Window Air Conditioners FIND TE BEST MODEL FOR YOU PAGE 4 PRODUCTS PAGES 5-14 ACCESSORIES
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
Energy Efficiency. Energy Efficient Home Cooling:
Energy Efficiency Energy Efficient Home Cooling: Choosing an air conditioning system is an important decision. A poor choice may be costly to purchase and operate and yet fail to provide the desired cooling
SECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
Thru-the-wall. Air Conditioners and Heat Pumps. 115-Volt: WS08, WS10, WS12 230-Volt: WS10, WS13, WS15, WE10, WE13, WE15, WY09, WY12 920-007-16 (5-10)
Installation and Operation Manual Thru-the-wall Air Conditioners and Heat Pumps WallMaster 115-Volt: WS08, WS10, WS12 230-Volt: WS10, WS13, WS15, WE10, WE13, WE15, WY09, WY12 920-007-16 (5-10) Your Safety
ECO-AIR AIR CONDITIONING www.northamericanhvac.com
INDEX ACCESSORIES INSTALLATION... 3-7 LINE SETS... 3-7 GEOTHERMAL... 3-8 WIRING CABLE... 3-8 CIRCULATOR PUMPS (PRO-TECH MODEL)... 3-9 DC INVERTER SINGLE ZONE HEAT PUMP... 3-6 DC INVERTER TECHNOLOGY...
FTQ. Daikin Inverter Ducted Heat Pump
FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
I N T R O D U C I N G. COMMERCIAL GRADE DURABILITY with BUILT-IN, 7 DAY PROGRAMMABLE THERMOSTAT
R O O M A I R C O N D I T I O N E R S I N T R O D U C I N G COMMERCIAL GRADE DURABILITY with BUILT-IN, 7 DAY PROGRAMMABLE TERMOSTAT Q U A L I T Y The room air conditioners preferred in the most demanding
PACKAGED TERMINAL AIR CONDITIONER (PTAC) / PACKAGED TERMINAL HEAT PUMP (PTHP) AND ACCESSORY INSTALLATION INSTRUCTIONS
PACKAGED TERMINAL AIR CONDITIONER (PTAC) / PACKAGED TERMINAL HEAT PUMP (PTHP) AND ACCESSORY INSTALLATION INSTRUCTIONS PTAC/PTHP AND ACCESSORY SAFETY... PLANNING THE INSTALLATION... Typical Unit Components...
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
FTXS. Wall Mount Heat Pump or Cooling Only
FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both
2010 Duct-Free Splits Line Card
2010 Duct-Free Splits Line Card Right Product for the Right Application 2010 Duct-Free Splits Right Product for the Right Application 1:1 2:1 to 4:1 9-24K High Walls 18-24/36/42/60K High Wall, Cassette,
Fan Speed. Auto Swing. Fan. Only. Saver. Temp. Dry. Timer. Power. Mode CP06 CP08. Fan. Speed. Auto Swing. Only. Saver. Temp. Dry. Timer. Power.
Cool Dry Mode Temp Fan Speed Timer 0n/0ff Money Saver Mode 0F hr Fan Cool Only Dry Temp Auto Swing Power 0F Fan Speed hr Timer 0n/0ff Money Saver Fan Only Auto Swing Power CP06 CP08 200 Congratulations!
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
innovative comfort solutions
engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,
Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Pipe Freeze Protection Heating Cable Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord & Plug Thermwire-Comp Refrigeration
Important Safety Information. Operating Instructions The Controls on Your Zoneline Care of Product
Zoneline Heat Pump Model 5100 Series Zoneline Owner s Manual Important Safety Information 3 Operating Instructions The Controls on Your Zoneline Care of Product 4 Installation Instructions Important Electrical
Geyser-R Heat pump water heater Installation manual
Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed
Greensource iseries HY Model Unitary Air Handler/Fan Coil
Engineering Submittal Sheet Overview Model Nomenclature HY 035 00-1 HY - HYDRONIC AIR HANDLER NOMINAL CAPACITY IN THOUSANDS OF BTUH VOLTAGE DESIGNATION 1 = 208-230/1/60 ELECTRIC HEAT KW 00 - NO ELECTRIC
Air Conditioners and Heat Pumps. 115-Volt: WS08C10A, WS10C10A, WS12C10A 230-Volt: WS10C30A, WS13C30A, WS15C30A. 115-Volt: WE10C33A, WE13C33A, WE15C33A
Temperature Cooler Warmer Only Speed Saver Timer Operation Service Manual 2010 Thru-the-wall Air Conditioners and Heat Pumps WallMaster Cool Power Fan Fan Heat Money Start Stop Set Hr. WallMaster R-410A
AROS SMART WINDOW AIR CONDITIONER
AROS SMART WINDOW AIR CONDITIONER Part of the Quirky + GE collection of smart products, Aros is an app-enabled air conditioning unit that reacts to its surroundings to save you Time, Energy & Money. TABLE
FHQ. Ceiling Suspended Heat Pump or Cooling Only
FHQ Ceiling Suspended Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FHQ ceiling suspended SkyAir systems are ideal for applications without false ceilings. Installed from the structure, this
SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03
Domestic Air Conditioner SERVICE MANUAL Model HW-05LN03 Feature Anti-mold filter Mechanical control Easy clean filters Slide chassis 4-way airflow direction 2 cool settings, 2 fan settings Serial Number:
WINDOW AIR CONDITIONER INSTALLATION AND OPERATION
WINDOW AIR CONDITIONER INSTALLATION AND OPERATION CATALOG NO. PRODUCT CODE WH12ZM 420-0074 950-0053-revA 11-09-06 Page 1 of 20 TABLE OF CONTENTS AIR CONDITIONER SAFETY.2 NORMAL CARE & MAINTENANCE.3 INSTALLATION
VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water
2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation
Timer 0n/ 0ff. Mode. Dry. Dry Money Saver. Auto Swing. Fan Speed. Power. Temp CP10 CP12. Timer. Mode. Money Saver. Auto Swing. Fan Speed. Power.
Mode Fan Only Cool Fan Speed Dry Timer 0n/ 0ff Money Saver Mode Timer 0n/ 0ff Fan Only Cool Dry Money Saver Fan Speed CP0 CP2 20 7 Congratulations! Thank you for choosing Friedrich. Your Friedrich unit
Low Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
ARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
Ductless Mini-Split Systems. Comfort... where you need it, when you need it
Ductless Mini-Split Systems Comfort... where you need it, when you need it Ductless mini-splits THE COMFORT SOLUTION Ductless mini-split systems are a great solution to a wide variety of installation challenges,
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Installation and Operating Instructions
E-TAC (GB Series) Packaged Terminal Air Conditioner / Heat Pump 7,000 --- 15,000 Btuh Installation and Operating Instructions NOTE TO EQUIPMENT OWNER: Thank you for purchasing a Gree E-TAC. Please read
Comfort... where you need it, when you need it. Ductless Mini-Split Systems
Comfort... where you need it, when you need it Ductless Mini-Split Systems Comfort... it s what we re all about At Comfort-Aire, we re in the business of making you comfortable, whether at home, work,
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
OPERATING & MAINTENANCE MANUAL. Packaged Terminal Air Conditioner (PTAC) World Class Comfort.
OPERATING & MAINTENANCE MANUAL Packaged Terminal Air Conditioner (PTAC) World Class Comfort. OPERATING & MAINTENANCE MANUAL PACKAGED TERMINAL AIR CONDITIONER (PTAC) WELCOME Congratulations on your selection
Installation, Operation, & Maintenance Manual
R10C/H R20C/H R35C/H R45C/H R80C/H R90C/H Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Heat Pump (PTHP) The Right Fit for Comfort Straight cooling nominal capacities 9,000 12,000 15,000 18,000
FCQ. Roundflow Cassette Heat Pump or Cooling Only
FCQ Roundflow Cassette Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FCQ roundflow cassette SkyAir systems are ideal for open plan applications where variances in temperature and airflow
Owner s Manual. Important Safety Information. Operating Instructions The Controls on Your Air Conditioner Care of Product
Models: ABN08 ABP10 ABN10 ABV10 Air Conditioner Owner s Manual Important Safety Information 3 Operating Instructions The Controls on Your Air Conditioner Care of Product 4 Installation Instructions Important
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
AROS SMART WINDOW AIR CONDITIONER
AROS SMART WINDOW AIR CONDITIONER Part of the Quirky + GE collection of smart products, Aros is an app-enabled air conditioner that reacts to its surroundings to save you time, energy and money. TABLE
TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402
TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE
Cabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
READ AND SAVE THESE INSTRUCTIONS. INSTALLATION AND WIRING MUST BE IN ACCORDANCE WITH CEC, NEC AND LOCAL ELECTRICAL CODES.
16EC SERIES UPFLOW PACKAGED TERMINAL AIR CONDITIONERS Electric Heating and Cooling Unit Cooling - Only Unit INSTALLATION & OPERATION MANUAL IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. INSTALLATION AND
Air-Conditioning Buying Guide
Air-Conditioning Buying Guide Buying a new air-conditioning system is a big decision. This Air-Conditioning Buying Guide can help you make the right choice, save energy and money. Shop with confidence
0150506194 C Limited 2nd through 5th Year Functional Parts Warranty During the 2nd through 5th year,haier will provide functional parts which prove to be defective due to workmanship
Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03
Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible
Gree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
Room Air Conditioner Installation and Operating Manual
Room Air Conditioner Installation and Operating Manual EPA DOE KStar KQ08E10 Registering Your Room Air Conditioner Model information can be found on the name plate located on the side of the unit near
FBQ. DC Duct Heat Pump or Cooling Only
FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat
Split System Cooling Product Data
Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess
MAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
AIR CONDITIONING and HEAT PUMP PRODUCTS
AIR CONDITIONING and HEAT PUMP PRODUCTS February 2015 The History of Panasonic Air Conditioning The Panasonic Air Conditioning Group has grown into a global company through its continuous quest for product
PORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION
SASO 2663 :2014 ENERGY LABELLING AND MINIMUM ENERGY PERFORMANCE REQUIREMENTS FOR AIR-CONDITIONERS
SASO 2663 :2014 (SASO 2663/2012 including the modifications approved in Saudi Council Board No../2014) ENERGY LABELLING AND MINIMUM ENERGY PERFORMANCE REQUIREMENTS FOR AIR-CONDITIONERS ENERGY LABELLING
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
French Door Refrigerator E23BC78IPS professional series
French Door Refrigerator E23BC78IPS professional series 23 CU. FT. COUNTER-DEPTH FRENCH DOOR REFRIGERATOR Custom Temp Drawer Enjoy the ultimate in versatility with 9 preset selections including White/Sparkling
Packaged Terminal Air Conditioners & Heat Pumps
Packaged Terminal Air Conditioners & Heat Pumps October 2000 Introduction The new Trane packaged terminal air conditioners (PTACs) and heat pumps are ideally suited for offices, apartments, hotels, motels
PTAC Selection Guide. Optimize your spend with the right PTAC equipment!
PTAC Selection Guide Optimize your spend with the right PTAC equipment! The Direct Supply Difference Direct Supply Equipment & Furnishings understands the challenges of securing equipment for your communities.
Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications
Mini-Split Air Conditioners and s for Residential and Light Commercial Applications 3 TABLE OF CONTENTS FEATURES Mini-Splits Defined... 4 Individual Zoning... Comfort Solution... 8 Energy Efficient...
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY
Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY Designed and built with the commitment to high-quality craftsmanship you expect from American Standard, our ductless
Troubleshooting Your Refrigerator
Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.
REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:
7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: [email protected] Website: www.centrair.ca
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4 & 5 Ton 2-Stage Wall Mount Heat Pumps AND W38H, W43H, W49H and W61H Single Stage Wall Mount
Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify
Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2
Care and Cleaning Air Filters...11 Base Pan...10 Outdoor Coils...10 Room Cabinet and Case...10 Vent Filter...10
ge.com Zoneline Air Conditioners Safety Instructions...........2 Operating Instructions Air Direction.................4 Auxiliary Controls...........5 9 Controls.....................3 To Remove the Room
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
AIR CONDITIONER & HEAT PUMP SERVICE MANUAL
AIR CONDITIONER & HEAT PUMP SERVICE MANUAL AL This Service Manual is the result of the dedication of The Dometic Corporation and its engineers to providing service people the necessary instructions for
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
LOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
Split System Heat Pump Product Data
Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]
REMOTE CONTROL MANUAL
REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read
TABLE OF CONTENTS UNIT FEATURES OPERATING INSTRUCTIONS. 230V 20 Amp. 120V 15 Amp Figure 1. LCDI Power Cord Figure 2
THROUGH THE WALL ROOM AIR CONDITIONER WITH OPTIONAL ELECTRIC HEAT INSTALLATION INSTRUCTIONS RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. ATTENTION INSTALLING PERSONNEL As a professional installer you
AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS
AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS FOR AC135, AC150, AC135HP, AC150HP, ACRG12, ACTH12 RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: