EMO T. Thermal actuator for heating, ventilation and air conditioning systems



Similar documents
HERZ-Thermal Actuators

Thermostatic Actuators

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Automatic control equipment for HVAC systems

Technical catalogue convectors POLAND 2012

3/2-way Solenoid Valve, direct-acting, NC or NO

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Low-H2O valves Y EARS

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Thermostats. Technical information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Infrarot-Bewegungsmelder IP44

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RRV934. Multi-controller. Synco living

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Digital input modules

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Adjustable room thermostat for heating only or cooling only systems

Butterfly Valves PN 6/10/16 for flanged connection

Data sheet ECC 12 and 22

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

How To Use A Flowmeter

Electric Rotary Actuator - On/Off or programmable control actuator

Thermistor motor protection

E-STOP relays, safety gate monitors

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Valve range. To be precise.

Solenoid valves Type EVU

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Proportional pressure regulators VPPE

T5000 T000 LCD Digital Fan Coil Thermostat

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

RY2 miniature industrial relays

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

G1/4 Q8. Standard with biased position

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Actuator-Sensor-Interface

servo-controlled 3-WaY vacuum solenoid valves WiTH

System 8. ü ( System 8

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Series 8146/5-V37 and Series 8150/5-V37

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Mikrotherm. Manual radiator valves. To be precise.

ACS-30-EU-EMDR-10-MOD

15 Series - Electronic step relay and dimmer. Features SERIE

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

HDA

1. Geo Vertical 2. Geo Horizontal

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

4/2-Way Pneumatic Solenoid Valve

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Product and Application Description

picomax The Pluggable Connection System

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

AMTRON E-30 Compact heat and cooling meter

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Directory chapter 04

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Common Features of Electromechanical Switches

Heating Controller. Building Technologies HVAC Products

Product and functional description

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Contact expansion modules

Powers Controls TH 192 S Single Temperature Room Thermostat

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

J TB/TW Temperature limiter, temperature monitor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Redundancy Module QUINT-DIODE/40

Relés e Contatores de Estado Sólido SIRIUS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Contact expander modules

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

PNOZsigma - Base units

2- and 3-port valves with flanged connections, PN 10

Electronic Control Devices The European Product Catalogue 2007

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Power Thyristor TS3 (SP) 3ph. Installation Guide

Drayton Digistat +2RF/+3RF

Cable Plug acc. to DIN EN , Form A

Data sheet Thermostatic sensors type RA 2000

Type overview. Technical data

Transcription:

EMO T Thermal actuator for heating, ventilation and air conditioning systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEEING ADVANTAGE

EMO T Description The EMO T thermal actuator is a twopoint actuator for connecting to room temperature controllers with a two point output, e.g. HEIMEIE room thermostats or Thermostat P. Models with 30 V (with built-in overvoltage protection 4 kv) and 4 V operating voltage, each currentless closed (NC) or opened (NO), enable a versatile application in heating, ventilation, and air conditioning systems. EMO T has an electrically heated expansion system which is secured against overtravel. The pressure power within the closed range is adapted for thermostatic valve bodies with soft valve discs. It is maintenance-free and functions without noise. Depending on the model, in a currentless status, EMO T holds the valve closed (NC model) or open (NO model). The attractively designed body of the EMO T is constructed of a white (AL 9016), heat-resistant, shock-proof plastic. The EMO T is designed to be installed on all HEIMEIE thermostatic valve bodies and three-way valves. Its compactness also makes it suited to installations in manifolds cabinets. Assembly EMO T 30 V model (NC) 1. Varistor. PTC heating element 3. Spring 5. Expansion system Wide range of uses due to versatility of available models Functional dimensions Built-in overvoltage protection guarantees security of operation (with 30 V model) eliable, silent and maintenance-free Model with theft protection Elegant design

Function Closed when currentless (NC model) Initiating operating voltage heats up the expansion system of the actuator. After the time lag, a uniform opening process ensues. If the voltage is cutoff, the actuator closes via the cooling of the expansion system after the time lag. Open when currentless (NO model) Initiating operating voltage heats up the expansion system of the actuator. After the time lag, a uniform closing process ensues. If the voltage is cutoff, the actuator opens via the cooling of the expansion system after the time lag. Note When conducting a performance test, be sure to check the time response (time lag)! Opening and closing times are dependent on the ambient temperature. Action chart NO max.,5 mm NO: 10 N NC: 95 N NC ; I I 0 ~1min. ~1min. ~ 3 min. ~ 3 min. Application The EMO T thermal actuator can be installed in temperature and/or timerelated -point control systems in, for example: Heating installations For floor, ceil, and radiator heating systems for individual room temperature control or group control in: apartments, conference rooms, storage rooms, schools, etc. For reverse switching, mass flow control, etc. Ventilation installations For room temperature control, e.g. controlling the flow of hot water through the air heaters. Air conditioning systems For room temperature control, e.g. regulating the flow of cold water from fan-coil units, ceil cooling systems, etc. Connection diagram N L 30 V/4 V AC/DC EMO T L max. (see planning notes) 3

Technical data 30 V 4 V Operating voltage: - Frequency 30 V AC/DC (+10%/-15%) 0 60 Hz 4 V AC/DC (+5%/-10%) 0 60 Hz Power draw (continuous operation): - when operating 3 W (VA) 90 W (VA) 3 W (VA) 9 W (VA) Stroke:,5 mm,5 mm Pressure power: NO 10 N / NC 95 N NO 10 N / NC 95 N Close and open time: ~3 min. ~3 min. Type of protection: - horizontal installation - vertical standing installation EN 6059 IP 4 IP 43 EN 6059 IP 4 IP 43 Protection class: ; II, EN 60730 ; II, EN 60730 Overvoltage protection: Varistor - Body, colour: PC (shock-resistant), white AL 9016 PC (shock-resistant), white AL 9016 Connection cable: 1 m *), x 0,75 mm 1 m *), x 0,75 mm CE certification (EMV / NS): EN 55014-1, EN 60730--14 EN 55014-1, EN 60730--14 Ambient temperature (in operation): 0 C 50 C 0 C 50 C Medium temperature: max. 100 C (1 F) max. 100 C (1 F) Storage temperature: -0 C +70 C (-4 F +158 F) -0 C +70 C (-4 F +158 F) Mounting: fits all HEIMEIE thermostatic valve bodies and three-way valves Max. permissible differential pressure with closed valve: See prospectus for thermostatic valve body; three-way reversing valve; three-way mixing valve; control valves for floor heating systems Article numbers Art. No. 30 V Currentless closed (NC) 1831-00.500 Currentless closed (NC) with theft protection using security ring 1831-00.530 Currentless open (NO) 1835-00.500 4 V Currentless closed (NC) 1841-00.500 Currentless open (NO) 1845-00.500 Dimensions ø47 63 ø5,7 M 30 x 1,5 1 mm = 0,0394 inch 4

Planning notes 4 V transformer dimensioning For operation with 4 V low voltage, a transformer is required which is in compliance with EN 60335 and possesses sufficient capacity. For dimensioning transformer performance, the value for the operating phase needs to be taken into account. The same applies to the layout of switching contacts of room temperature controllers. Minimum transformer power delivery results from: the sum of the take-up of the 4 V EMO T (in the operating phase) in addition to the sum of the take-up capacities of Thermostat P. oom temperature controllers (art. no. 1946/48-00.500) need not be taken into account. Calculation example: ea. Thermostat P 4 V (art. no. 194-00.500) at 1.5 VA each = 3 VA 6 ea. EMO T 4 V (art. no. 1841/45-00.500) at 9 VA each = 54 VA Total of take-up = 57 VA ( minimum transformer power delivery) Selected transformer = 63 VA 4 V protective low voltage With the required protective low voltage (SELV based on DIN VDE 0100) a safety isolating transformer in compliance with EN 6074 must be used. Length of cable In order to maintain the declared opening times for the actuators, the voltage loss (depending on length of cable and cross section) in the operating phase on the supply lines to the actuators may not exceed 4%. For general dimensioning with copper lines, use the following standard formula: L max. = l / n L max.: max. length of cable in [m] (see connection diagram) l: table value in [m] n: number of actuators Line: Type/name Cross section: A l for each model: 30 V 4 V Note: Application; comparison [mm ] [m] [m] LiY/twin flexible rod 0,34-4 only for 4 V; corresponds to ø 0.6 mm Y()/bell wire 0,50-35 only for 4 V; model Y() x 0.8 H03VVF/PVC mains cable 0,75 494 53 not to be concealed under plaster NYM/house wiring cable 1,50 988 106 also for NYIF 1.5 mm NYIF/flat webbed house wire,50 1646 177 also for NYM.5 mm Calculation example Goal: max. length of cable L max. Given: Voltage U = 4 V Conductor cross section A = x 1.5 mm Value in table l = 106 m Number of actuators n = 4 Solution: l max. = l / n = 106 m / 4 = 6,5 m 5

Accessories Connecting to other brands Adapter for mounting the EMO T on valve bodies of other manufacturers. Threads M 30 x 1.5 factory standard. Danfoss A 970-4.700 Danfoss AV 9800-4.700 Danfoss AVL 9700-4.700 Vaillant (Ø 30 mm) 9700-7.700 TA (M 8 x 1,5) 9701-8.700 Herz 9700-30.700 Markaryd 9700-41.700 Comap 9700-55.700 Oventrop (M 30 x 1,0) 9700-10.700 Giacomini 9700-33.700 Ista 9700-36.700 otex 9700-3.700 Uponor (Velta) - Euro-/Kompakt distributor 9700-34.700 or return valve 17 Uponor (Velta) - Provario distributor 9701-34.700 Connecting to radiators with integrated valves Adapter for mounting the EMO T with M 30 x 1.5 connection on thermostatic insert for Series or Series 3 clamping joint. M 30 x 1.5 threading, factory standard adiator manufacturers: thermostatic head prospectus Serie 9703-4.700 Serie 3 9704-4.700 Trafo-Station Connection diagram Transformer station The transformer station is a 4 V lowvoltage transformer in accordance with EN 60335 in a protective insulation and a shock-proof plastic body. It is used as a power supply for actuators and room temperature controllers. oom temperature controllers (max. 10 room temperature controllers 4 V or Thermostat P 4 V) may be connected to the output terminals in conjunction with a maximum of 10 EMO T 4 V, in random assignment, depending on installation conditions. It is also possible to connect thermal actuators which are currentless open or closed. The transformer station is protected at the output and line ends by standard fine-wire fuses. Art. No. 1600-00.00 Application example bath entrance child kitchen parents living room = oom thermostat or Thermostat P 6

Technical data Operating voltage: 30 V AC (+ 6% / 15%); 50 / 60 Hz; 60 VA Output voltage: 4 V AC (+ 5% / 10%); 50 / 60 Hz Power output: max. 56 VA (in continuous operation) Output connections: max. 10 actuators and 10 room temperature controllers or 10 Thermostat P (see connection diagram/application example) Length of cable Ø max. values see Planning notes Type of protection: IP on EN 6059 (depending on installation requirements) Safety class: II, EN 60335 Body, -color: ABS (shock-proof), light grey based on AL 7035 Power supply connection: plug-in device; 1 m; x 0.75 mm with European plug Connector terminal: clamping area max..5 mm CE certification (EMV / NS): EN 55014-1, EN 55014- / EN 60335-1 Ambient temperature: 0 C 60 C (3 F 140 F) in operation Mounting: Mounted to wall; cable fed from below Dimensions: 00 mm x 10 mm x 90 mm 7

Technical data 30 0 300 00 3000 000 10 0,0 0, 05 0, 03 0, 04 0, 05 0, 06 0, 0 7 0, 0 8 0, 1 0, 15 0, 15 0, 0, 5 0, 3 0, 4 0, 5 0, 6 0, 7 0, 8 1, 0 1, 5 1, 5, 0, 5 3, 0 4, 0 5, 0 100 1000 5 50 500 3 30 300 0 00 1 10 100 0,5 5 50 Δp [kpa] 0,3 0, 0,1 1 3 5 10 0 30 50 100 00 300 500 1000 000 ª 1 K vs value The kvs value of a valve indicates the volume flow for a completely open valve with a pressure loss of 1.0 bar. Standard formula for water medium: = œ / ( Δp) Symbols and units of measure Valve characteristic in m 3 /h œ Flow volume in m 3 /h Δp Pressure loss in bar Calculation example 1 Target: -value for determining valve Given: Mass flow ª = 3 kg/h Pressure loss Δp v = 34 mbar Solution: -value from diagram: 0,175 m 3 /h Selected: thermostatic valve body V-exact Presetting: 3 see thermostatic valve body prospectus) Calculation example Target: Δp thermostatic valve body Given: standard thermostatic valve body DN 10 straight form -value = 1,5 m 3 /h Mass flow ª = 130 kg/h Solution: Δp valve from diagram: 11 mbar 3 Δp [mbar] 30 0 10 Δp [mm WS] The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by TA Hydronics without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.tahydronics.com. 300-18.483 03.011 partner in your country www.tahydronics.com