1. Geo Vertical 2. Geo Horizontal
|
|
|
- Roy Farmer
- 10 years ago
- Views:
Transcription
1 Geo Vertical 2. Geo Horizontal
2 Geo Vertical 2. Geo Vertical with towel rail 3. Geo Vertical with cover plate
3 Geo Vertical 47
4 Geo Vertical Dimensions Connections Range GEVW_Geo Vertical Wall Code: 1 number = flow 2 number = return Vertical convection shafts (Model 180x60) E /2" 25.0 F G D 1 8 Standard connection Code 18 Connection 18 or C H Top end connection Ordering code: specify code 45 or 54 instead of 18. Insert pipe included without surcharge. Has to be mounted in the return. Always mount an air vent on the central heating system. GEVW_Geo Vertical Wall cover plate E G 1/2" Single point connection Ordering code: specify code 11 or 88 instead of 18. Always use a diffusion tube of min. length of 40 cm. No surcharge. Electro heating Standard code 18, and order an electric element. 6.0 K G 1/2" Dimensions in cm H C D E F G K Mixed Standard code 18. Order an electric element type mixed. - Fit the T-piece together with the electrical heating element for connection to the central heating wet system. - Never isolate the radiator from the expansion system, in other words never cut off the return of the radiator. Not standard connection without surcharge.
5 Outputs Geo Vertical H /65/ /70/ s o /65/ /70/ s o code height length colour conn. ORDERING CODE : GEVW XXX /18 Standard delivery - connection 18 underneath - stainless steel wall fixings. - chrome-plated air vent and drain cock 1/2 - plugs and screws Standard colours: - white light grey black sand Geo Vertical H Output measured in accordance with EN442, at a water temperature of 75/65 and a room temperature of 20 C (ΔT=50). C
6 Options Insert pipe for top end connection Towel-rail CO D E H r a d i a to r 50 insert pipe CODE H radiator 2.7 G 1/2" 1.45 Use PFTE or flax Will be delivered without surcharge if the top end connection code is indicated (45 or 54 instead of 18). Electro heating G 1/2" CODE H Type WATTS 0.9 Brushed stainless steel. Can be mounted at different heights % electric mixed (incl. 2 extended T-pieces) % electric mixed (incl. 2 extended T-pieces) Cover plate CODE opening radiator Pressure relief valve Adaptor right left none right left none Connection electric element - Fit the electric heating element vertically in the socket 1 or 8. The pressure release valve which is included should be fitted into socket 4 or 5, (3 bar). - Do not switch the radiator on before filling it completely with water. - Fill up with water after the first total heating up of the radiator. Price includes - cover plate in brushed stainless steel (1) - 2 chrome-plated extended T-pieces (2) - 2 drain cocks (3) - shortened coupling (4) /55 6 Cover plate including valves: see connection sets & valves For more information see Technical info. Extended T-piece CO D E TPCE co l o u r chrome For mixed application, connection at the side or the back.
7 Geo Horizontal 53
8 Geo Horizontal Dimensions GEHW_Geo Horizontal Wall Range / 120 / 140 / 160 / 180 ca ca Connections - supplied completely pre-mounted - including right handed connection with Jaga valve - chrome-plated TRV head - extension pipe - flexible hoses 1/2 ( 60 cm) for connection to the wall 60
9 Outputs Geo Horizontal code height length colour conn. ORDERING CODE : GEHW XXX /18 H /65/ /70/ s Standard delivery - build in ow-h2o heat exchanger - flexible hoses 1/2 (=60 cm) for connection to the wall - extended air vent and drain cock 1/2 - plugs and screws - Jaga valve with Deco thermostatic head chrome and extension pipe Standard colours: - black sand Geo Horizontal H Options ockshield 1/2 90, connection to the wall CODE 2.4 1/2" nickle-plated 1/2" 3 Output measured in accordance with EN442, at a water temperature of 75/65 and a room temperature of 20 C (ΔT=50).
10 1 1.Geo Mosis 56
11 Geo Mosis 59
12 Geo Mosis Dimensions MOSW_Mosis Wall Connections 60 Brushed stainless steel shelf Granulated natural stone washbasin Mirror Return CH M24 male thread Flow CH, M24 male thread Built-in Vola mixer tap H Granulated natural stone radiator Decorative screws, to be removed for attaching Vola accessories Hot water 1/2 female thread Cold water 1/2 female thread Drain ø 4 cm ATTENTION: flow always on the right hand side! Brushed stainless steel towel rail 90 Vola drainage pipe and overflow with stainless steel guard Pre-installed pipework with central connection underneath Connection to the floor with installation template included. Installation template 16 Chrome-plated Deco thermostatic head Washbasin connection and radiator connection (with installation template for connection to floor) Cover plate in brushed stainless steel
13 Outputs Geo Mosis code height length colour conn.position mixer tap ORDERING CODE : MOSW /MM / H /65/ /70/ Standard delivery - Mosis with built-in connections for the radiator and the washbasin, lockshield, thermostatic valve and chrome-plated thermostatic head - ockshields for sanitary connections - shields for warm and cold water - built-in Vola mixer tap - washbasin made from granulated natural stone - Vola drainage pipe / overflow with stainless steel guard - simple assembly and connection system - brushed stainless steel tablet - brushed stainless steel towel rail - mirror with fixings - installation template for connections to the floor, with brushed stainless steel guard - stainless steel wall fixings, incl. screws and plugs - chrome-plated air vent 1/8 H 61 Geo Mosis Standard colour: - black 603 The mixer tap, the tablet and the towel rail can be mounted left or right: add to the code / (left) or /R (right). Options Vola options CODE description Vola soap dish Vola soap dispenser Vola tooth brush holder with glassoo Output measured in accordance with EN442, at a water temperature of 75/65 and a room temperature of 20 C (ΔT=50).
1. Taboe Sani 2. Taboe 3. Taboe Freestanding
1 2 3 1. Taboe Sani 2. Taboe 3. Taboe Freestanding 72 1 2 1. Taboe Sani Single 2. Taboe Sani Double 74 Taboe Sani 75 Taboe Sani Dimensions TSSW_Taboe Sani Single Wall Connections Code: 1 number = flow
new Twine & Pinch A tribute to the traditional column radiator Eyecatchers From design to art 2009 Ex
new Twine & Pinch A tribute to the traditional column radiator Eyecatchers From design to art 2009 Ex The information in this price list is correct at the time of printing. Jaga reserves the right to change
new Eyecatchers From design to art 2008 Ex
new Eyecatchers From design to art 2008 Ex The information in this price list is correct at the time of printing. Jaga reserves the right to change product specification at any time in line with our policy
Low-H2O valves Y EARS
Low-O valves 0 Y EARS Pre-settable valves Why a balancing thermostatic radiator valve? Due to the application of the specially designed Jaga and Jaga Danfoss pre-settable Trv s, the flowing water amount
Brochure 2012-2013.EX
VERTIGA Brochure 2012-2013.EX VERTIGA The new benchmark for design at super-low water temperatures The ultimate expression of form and function. Vertiga combines the power of Jaga Top Performers, the efficiency
Itho Products for Hot and Boiling water. product-
Itho Products for Hot and Boiling water product- 2 This booklet provides additional information on the range of hot and boiling water appliances by Itho. The data will allow you to determine which product
Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction
The space saving solution.
10 KICKSPACE KICKSPACE. Over 70% of people think that they would benefit from additional kitchen space (ICM Research 2012) Kitchen kindly supplied by Second Nature kitchens - www.sncollection.co.uk The
How To Buy A Designo Grille
anal ompact anal Plus 1 2 3 1. omplete anal Plus underfloor unit 2. Heat exchanger and inside finish of the duct in dark grey 3. Enlarged range of grilles anal Plus Operating principal Options Flexible
AT FIRST SIGHT Important informations
Technical catalogue AT FIRST SIGHT Important informations TIPS FOR USING THIS GUIDE Our new technical catalogue includes now all important information you will need for planing or call for tenders. Every
Operators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
Universal items. Universal items 19.1
Universal items Universal items 19.1 Universal items Accessories / Fittings 04909 Grab bar with integrated shelf 010000 chrome-plated 1 126.50 01514 Towel hook 010000 chrome-plated 1 14.30 55 26 32 86
Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.
The Townhouses Park View Place A A Compass House A T T T Royal Wharf Gardens Endeavour House T A A Thameside House T Sienna House A A A A T Apartments Townhouses River Thames Compass House Compass House
Technical catalogue convectors POLAND 2012
Technical catalogue convectors POLAND 2012 index convectors review...3 Narbonne...4 Narbonne VT... 10 Narbonne V... 16 Narbonne V VT... 20 mounting distances for Narbonne...26 mounting distances for Narbonne
SF15K SF05KSS, SF10KSS
Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water
112039.00 224500 EMERGENCY PLUMBING FIXTURES
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following emergency plumbing fixtures: 1. Emergency showers. 2. Eyewash equipment. 3. Eye/face wash equipment. 4. Hand-held drench hoses. 5. Combination
Stove-boiler for solid fuels 12-30 KW Directions for use and assembling
Stove-boiler for solid fuels 12-30 KW Directions for use and assembling February 7, 2012 Contents 1 Technical data 2 1.1 Boiler properties TEMY PLUS 12-30 KW......................... 3 1.2 On Product............................................
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
Axor ShowerCollection with Philippe Starck Information & inspiration for professionals
Axor ShowerCollection with Philippe Starck Information & inspiration for professionals ConTenTS 04 The principle 10 The planning examples 35 The installations 43 The product overview 50 The references
Brochure 2012-2013.EX
CLIMA CANAL Brochure 2012-2013.EX CLIMA CANAL Complete climate control and high power Heating, cooling, ventilation. Despite it s modest size, clima canal is a powerful heating, cooling and ventilation
STABITHERM INSTALLATION & SERVICE BOOKLET
STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
1. Description. 2. List of Accessories included A B C F G H
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to
Planning Guide for Accessible Bathrooms AS1428.1-2009 including Amdt 1-2010, ambulant and complimentary items. Sydney Melbourne Brisbane Auckland
Sydney Melbourne Brisbane Auckland BACKRESTS RBA4150!SERIES BACKREST RBA4150!111 STAINLESS STEEL BACKREST RBA4150-101 Straight Arm Backrest RBA4150-201 Bent Arm Backrest Concealed mounting fl anges and
Shower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
Light Duty Commercial Electric Water Heater
Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and
Installation guide Nordic mixer taps. Before installing read this guide first
Installation guide Nordic mixer taps Before installing read this guide first Introduction Installation, maintenance and warranty The Nordic Twintaps are our latest innovation for your kitchen a boiling-water
Frequently Asked Questions
What is a Thermostatic Radiator Valve? TRVs sense the air temperature around them and regulate the flow of water through the radiator which they are fitted to. They do not control the boiler.they should
Installation Instructions
Installation Instructions S50-310 (Semi-Circular) S50-311 (Circular) Accu-Zone Infrared Control Conversion Kit for Terrazzo & Stainless Steel Classic Washfountains (Non-sectional) Table of Contents Pre-Installation
STOVE-BOILER FOR SOLID FUELS Directions for use and assembling
STOVE-BOILER FOR SOLID FUELS Directions for use and assembling Sadrºaj 1 Technical data 2 1.1 Boiler properties TEMY PLUS P 25............................. 3 1.2 On Product............................................
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters
Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters When water is heated, it naturally expands and allowance has to be made for this. Vented water heaters usually
Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: [email protected], Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Old people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.
nursing homes. SPECIAL SOLUTIONS. Security and comfort for every stage of life. 401 Model: Eurotrend Care wash basin EN 32, DIN 18024-2 and 18025-2 11-96 (, EN 14688) 1 without overflow, pre-punched tap-hole,
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home
Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email [email protected] Web www.morcoproducts.co.uk Retrofit or Upgrade a Water Heater in a Caravan
Assembly and instructions
Assembly and instructions Franke Minerva 3-in-1 Kettle Tap Retain for reference NB: For use only with Franke Heating Tank INTRODUCTION The Kettle Tap is suitable for dispensing boiling water (100 C) and
EMO T. Thermal actuator for heating, ventilation and air conditioning systems
EMO T Thermal actuator for heating, ventilation and air conditioning systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEEING ADVANTAGE EMO T Description The EMO T thermal
SERVICE MANUAL Order No.WH0911S001V0
SERVICE MANUAL Order No.WH0911S001V0 Electrical Water Heater Model No. FCD-JTSA50-III FCD-JTSA60-III FCD-JTSA70-III FCD-JTSA80-III! WARNING This service information is designed for experienced repair technicians
Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480
Installation and Service Instructions for use by heating contractors Neutralization System Part no. 7441823 Grünbeck part no. 410480 Safety and Installation Requirements Please ensure that these instructions
Instructions for designing heating systems.
Instructions for designing heating systems. In order to obtain the required effect, a lower consumption, a smaller quantity of impurities and improved comfort, heat and domestic hot water installations
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
swimming pool accessories
76 swimming pool accessories 77 Dolphin pool cleaners Dolphin Plus Battery Cordless pool cleaner with lithium ion battery Cleans the pool in 1.5 hours Special programs Clogged filter bag indicator Incl.
CHECKLIST C ACCESSIBLE TOILETS CHECKLIST
CHECKLIST C ACCESSIBLE TOILETS CHECKLIST These guidelines relate to accessible toilets for use by visitors. Different considerations may apply where accessible toilets are to be used by employees. All
IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.
QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your
A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.
SECTION 224500 - EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S
*1756202470* 17562.0247.0 REV3 06/09 2012 Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S Issue Table description Issue n. of pages Overall view 06/2009 1 C.h.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
Isotemp Basic, Slim/B & Slim Square
Isotemp Basic, Slim/B & Slim Square Water heater Installation and operating instructions Indel Marine S.r.l. Zona Artigianale sn IT-61019 S. Agata Feltria (PU) Italy Tel. 39 0541 848 030 Fax 39 0541 848
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G
Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G EN 215-1 HD 1215-2 Application RA 2910 built-in sensor RA 2920 tamperproof RA 5062 remote sensor temperature adjuster RA-FN
This section gives you some helpful information and tips on running your home and the equipment in it.
67 This section gives you some helpful information and tips on running your home and the equipment in it. Electricity Fuse board (electrical consumer unit) Make sure you know where your fuse board is and
PRISLISTE SANITARY WARE FURNITURE WELLNESS FAUCETS ACCESSORIES. Veiledende forbrukerpriser gjeldende fra 01.01.2015
PRISLISTE Veiledende forbrukerpriser gjeldende fra 01.01.2015 2015 SANITARY WARE FURNITURE NO WELLNESS FAUCETS ACCESSORIES CONTENT Important information List of conventional signs II II SANITARY WARE Colours
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50
CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.
CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
EcoSoft Water Softener. General Installation Guide
EcoSoft Water Softener General Installation Guide Planning Our Softener Installation Please observe any local or national regulations concerning the installation of your water softener. Check that there
THE PUSH-FIT SOLUTION FOR PLUMBING AND HEATING SYSTEMS
THE PUSH-FIT SOLUTION FOR PLUMBING AND HEATING SYSTEMS Speedfit Fittings are suitable for use with copper pipe. Included in this leaflet: Product Guide Trade Tips How Speedfit Works Making a Good Connection
Direct steam injection humidifiers
Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature
INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
Data sheet Thermostatic sensors type RA 2000
Thermostatic sensors type RA 2000 EN 215-1 RA 2990 RA 2992 RA 2920 RA 5060 RA 5074 Application The RA series is a comprehensive programme of radiator thermostats which covers all central and district heating
2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin
INSTRUCTION FOR ASSEMBLY 150x180 v Traditional sauna cabin 1. SAUNA PLAN 1800 LIGHT UNDER THE BENCH VENTILATION OUTLET UPPER BENCH 600 1500 LOWER BENCH 400 700 1656 956 HEATER 366 381 690 815 Light switch
Bypass level indicator With magnetic display Model BNA
Level measurement Bypass level indicator With magnetic display Model BNA WIKA data sheet LM 10.01 Applications Continuous level indication without power supply Indication of the level proportional to height
AIR PUMPS & ACCESSORIES
AIR PUMPS & ACCESSORIES Page Chapter 8 2 ECO-Oxy 3 ECO-Oxy 4 AIR Stones 5 AIR-Sets 6 Accessories 7 Pond Aerators 8 Spindrifter 9 OXY-Light 10 Spindrifter Bottom Drain Chapter 8 page 1 Chapter 8 page 1
Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.
Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1. Please read and understand these instructions before starting work. Please leave this leaflet
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
Thermostatic element RAVV for 2-way valves
Description / Application RAVV is a self-acting thermostatic element which can be combined with 2-way valve bodies RAV-/8, VMT-/8 or VMA 15. RAVV is used to control temperatures in small hot water cylinders
Electric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
Modus. Made in Italy dal 1958
Modus Made in Italy dal 1958 modus design architetto Paolo Bertarelli Finiture / Finishes Cromato / Chrome plated 52054 Monocomando per lavabo con scarico 1 1/4. Single-lever washbasin mixer with 1 1/4
Cylinder head gasket, replacement
"VCC065612 EN 20110604" 1(7) Cylinder head gasket, replacement Special tools: 999 5098 Disconnect battery earth lead Drain coolant Remove heat shield over exhaust manifold. (Only the two bottom bolts on
Complete units. Complete underfloor box for one Modul 45 socket and two data connection sockets. Complete service outlets
Complete underfloor box for one Modul 45 socket and two data connection sockets Screed height 105-165 mm In the field of complete service outlets, the GE 1 and GET 1 models are a universal, high-quality
INSTALLATION INSTRUCTIONS BL-8704
INSTALLATION INSTRUCTIONS BL-8704 EXPOSED BLACK LEVER THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1
FLEXCON EXPANSION VESSELS. Flamco FLEXCON 2-80. Flexcon. Expansion vessels FLEXCON 110 1000 FLEXCON M. Flamco FLEXCON V-B.
FLEXCON EXPANSION VESSELS Flamco 1 Flexcon Expansion vessels FLEXCON 2-80 FLEXCON 110 1000 FLEXCON M Flamco FLEXCON V- 2007 edition / UK Flamco Flexcon the first name in expansion vessels Flamco has over
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant
Geberit Mapress Catalogue 2008 / 2009. Valid from 1 April 2008
Geberit Mapress Catalogue 2008 / 2009 Vali from 1 April 2008 Mapress Stainless Steel Page 3 Mapress CrNi Steel Page 23 Mapress Stainless Steel silicone-free Page 25 Mapress Stainless Steel Gas Page 39
Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options
Flue Options Ace Finest Finest Gold Best 30/40/50/60 Best 80 Flue Options Flue Options Flue Options Flue Options B r i t i s h M a d e B o i l e r s Halstead have been manufacturing boilers in the UK since
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
FLASH TANK ECONOMIZER PRODUCT GUIDE
FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.
LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.
LK Wallbox UNI Push Only intended for LK PE-X Universal Pipe X. LK Wallbox UNI Push 16 Single Article no. 188 06 38 LK Wallbox UNI Push 20 Single Article no. 188 06 39 LK Distance template LK Wallbox UNI
Knürr Smaract. Knürr Smaract. CompactRack
CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.
5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013
ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 0 QUALITY 0 YEAR GUARANTEE Exclusively distributed by: Table of contents Panel radiators General / Guarantee Technical data and radiator dimensions
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
How To Build A Brugman Compact Radiator
THE ESSENCE TECHNICAL DOCUMENT 2010 OF WARMTH horizontal Standard compact 4 universal compact vertical Verti M Standard Verti M Compact horizontal piano universal compact vertical Verti M Piano mini piano
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+
Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric
SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL
SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.
Mikrotherm. Manual radiator valves. To be precise.
Manual radiator valves To be precise. Description HEIMEIER Mikrotherm manual radiator valves made of corrosion-resistant gunmetal, with white plastic hand wheel cap, tight-packed with protection film.
Qualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation
Qualification Guide BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation BPEC 600/5270/3 - Level 2 NVQ Diploma in Plumbing and Heating BPEC
WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST
0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL
Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems
Knürr CoolAdd The universal retrofit solution against overheating in server racks Rack & Enclosure Systems Knürr CoolAdd When cold air is no longer enough! Data centers are subject to constant changes:
