Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier



Similar documents
BARRIER LIFT SYSTEM 2 BARRIER LIFT SYSTEM

Hydraulic Control Solutions

WE-350 Series ¼ Turn Electric Actuator

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Oil and Coolant Circulating Heating System. Model - OCSM

HERZ-Thermal Actuators

JUBILEE TECHNICAL TRAINING CENTRE TAKORADI POLYTECHNIC 2015 TRAINING PROGRAMMES

INDEX 1. GENERAL INFORMATION SYSTEM COMPONENTS OPERATING INSTRUCTIONS MAINTENANCE... 18

Diesel Engine Driven Generators Page 1 of 6

1 ELGOTEAM ADVANCED SECURITY SYSTEMS Bi-directional spike barrier. Bi-directional spike barrier Customer Information packet

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

1300 MAXTRAK SPECIFICATION

Marine Generating Sets 3.7 to 50 kva

A U T O M O T I V E L I F T S

Electronic Control Devices The European Product Catalogue 2007

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

understanding medium frequency induction melting furnace and its components

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Specification. Safelift Overhead Travelling Cranes

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Designed for multi-injector endurance testing, the

COMMISSIONING OF HVAC SYSTEMS

RS Security Co., Ltd. RS Security Co., Ltd is specialized in physical access control turnstiles;

PLM series Permanent load lifting magnets

SECTION MORTUARY REFRIGERATORS

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

ECOCIAT. Domestic hot water heat recovery unit

Ticket Reader with real time clock and magnetic encoding

garage door operators

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

1x90 TONS TENSIONERS TECHNICAL PROPOSAL. 1 X 90 Tons 30 m/min Tensioners TECHNICAL PROPOSAL JOB 08/ /02/2008 Basic proposal PP GM SB

DIESEL FUEL CONDITIONING

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

VEHICLE SPEED CONTROL SYSTEM

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Commercial Gas Furnace Upflow

Standard offering (pumps)

DIGITUS Network & Server Cabinets. UNIQUE Series

Group TRAFFIC MANAGEMENT SPECIALIST ACCESS WAY SOLUTIONS CREATIVE SOLUTIONS TO COMMON CHALLENGES. Products

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

LIFT CONTROL SYSTEMS CATALOGUE 2007

Morgue refrigeration unit

Electrical Safety Products

Power consumption (kw)

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

GTEC transfer switch open transition

Wynn s Extended Care

GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS

Conventional Fire Detection and Extinguishant Control System Specification

LIFT CONTROL SYSTEMS CATALOGUE 2007

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Automatic Fire Fighting Monitors

Cooking at the Speed of light!

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

your total solution provider

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed.

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Magnum Mobile Generator MMG55 Specifications

Butterfly Valves PN 6/10/16 for flanged connection

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

CO2 Alarm. Operation. Application

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

COMPLETE SOLUTIONS FOR MAGNETIC MEDIA MANAGEMENT V660 HDD

Electric Flow Boiler

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

High Security Heavy Duty Shredders VZ Perfect shredding and high performance in DIN security levels 4 and 5

MODEL HSR-007 Direct Drive Rolling Steel

ELECTRIC CENTRAL HEATING FLOW BOILER

A sophisticated design for a demanding field. prima series

ITEM DESCRIPTION SPECIFICATION TENDER OFFER

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

LIEBERT VNSA Installation Sheet

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Heavy-Duty Lube and Fuel Truck Sales Tool

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Fisher 377 Trip Valve

GPD 506/P5 Start-up Procedure and Checklist

m a n u a l t é c n i c o

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

FAIRBANKS NIJHUIS FIRE PUMPS.

SUSPENSION AND STEERING OVERVIEW

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

MANAGEMENT SOLUTION (P.A.M.S.)

Advanced Fencing and Security Technologies Ltd

Adaptive Cruise Control System Overview

Transcription:

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational requirements of the EB950 CR Armstrong HSLAB for use in high security environments. Each system will be comprised of a number of HSLAB s with associated Control Systems and Access Control Equipment. The EB950CR is a specialised blocking system for use in circumstances where foundations cannot be provided in the roadway. B. Barrier Unit B.1 Barrier Construction The Barrier is to be constructed using a heavy steel plate cabinet housing the hydraulic power unit and ram. This power unit will raise and lower a steel arm constructed of a substantial steel section with stiffener plates fully welded to the top and bottom of the arm. The rotation will be facilitated by a heavy steel cross- with the rotation shaft secured through Nylocross self lubricating bearings, shaft secured through Nylocross self lubricating bearings. The Barrier is to be mounted on a support plate which is attached to one of a pair of barrier arm support posts (one on both sides of the roadway). The arm is to be fitted to a moveable joint which will slide, under impact, into hooks on the barrier arm support posts thereby locking the arm in position. In addition to this, the sliding joint will remove the impact forces from the barrier cabinet and drive unit ensuring that when the sliding joint is reset, the system will remain operational. On impact, the forces exerted on the Barrier arm should be transmitted through the substantial support posts and into the re-enforced foundations. The Barrier should be designed to absorb / withstand impacts from both US and European manufactured vehicles taking into account the varying weight distribution of both styles. B.2 Barrier Height The height of the segment when in the closed (lowered) position, as measured from the top of the arm frame, will be a minimum of 900mm in accordance with BS6571 part 4 to minimise the possibility of site penetration and to ensure that higher chassis vehicles are restrained. 1

B.3 Barrier Width The width of the barrier arm will be between 3,000mm and 5,000mm to suit site conditions. B.4 Finish The Barrier cabinet and arm are to be finished with an anti-corrosion paint. C. Hydraulic System (HPU) C.1 Operation The HPU will consist of a heavy duty motor driving a hydraulic pump which will actuate, via a manifold and set of electrically operated valves, an hydraulic ram. The Barrier arm will be driven both up and down by the double acting hydraulic ram to ensure positive action at all times without reliance on gravity for operation. C.2 Hydraulic ram The double acting hydraulic ram fitted to the Barrier incorporates with an over centre valve which will stop the arm from lowering if damage is sustained to the hydraulic hoses. For safe maintenance, the hydraulic ram must be accessible from the road surface when the Barrier is in the fully lowered position. C.3 Limit Switches Proximity limit switches will be fitted to provide raised and lowered signalling to the control system. The switches will be M18 sized inductive type with no moving parts and have a minimum IP rating of IP68. C.4 Motor The heavy duty motor used in the HPU will be a 3ph, 230v unit with a power rating sufficiently sized to allow for continuous operation (100% duty cycling). An inverter system is to be provided to enable a graduated acceleration and deceleration at the Barriers raised and lowered limits. The motor should be protected by a thermal / magnetic trip device mounted in the inverter system. 2

C.5 Hydraulic Reservoir The hydraulic oil will be contained in a steel reservoir which is to be sized to allow sufficient oil cooling necessary for 100% duty cycling of the blocker. If the system is to be used in extremely low temperatures then an immersion tank heater can be added to maintain the minimum oil temperature for operation. C.6 Power fail conditions A hand pump / release will be provided to enable the manual raising and lowering of the blocking segment in the event of electrical power failure. C.7 Casing The Barrier cabinet will have fully lockable doors to the front of the cabinet for ease of access. Vents can be fitted into the cabinet if required to allow good air circulation maintaining the ambient temperature. D. Control System D.1 Main Processor The HPU will be controlled by a central programmable logic controller (PLC) which will accept inputs from the access control system, barrier monitoring equipment and hydraulic pack and output signals to the HPU control valves, back indication system and external signalling. The PLC controller shall be sized to suit site requirements but should have 8 inputs and 6 outputs as a minimum. The initial PLC programming shall be to suit specific client and site requirements however reprogramming of the system must be easily undertaken and password protected access to the program must be provided to the client with the relevant program ladder diagram. All relays will be properly mounted and all interconnecting cabling must be in suitable containment running to terminal strips. D.2 Voltage The main system input voltage is to be 230v 1phase 50-60Hz supply with the control system operating at 24V SELV provided from an internally mounted power supply. D.3 Casing The control system will be housed in a general purpose IP65 rated housing with a power isolation switch mounted externally for safety. The housing will be located inside the main Barrier cabinet and should give easy access to all electrical components for connection, maintenance and programming. 3

E. Access Control E.1 Remote Control Panel Each HSLAB will come with its own remote control panel which will be comprised of push buttons to raise, lower and emergency stop the equipment. E.2 System Interfacing The control system will be capable of accepting inputs from every major type of access control including but not limited to Swipe card readers, proximity card readers, inductive loop systems, RF transmitter equipment and biometric readers. The system must be able to interface with other equipment (by other manufacturers) to create an interlock. F. Performance F.1 Manufacturers Experience The manufacturer of the HSLAB will have a minimum of 15 years experience in the manufacture, installation and maintenance of this type of equipment and must be a member of a recognised Professional Trade Association. F.2 Testing The HSLAB design must fully comply with CE regulations and an actual full scale crash test must have been carried out by a qualified independent testing agency with the HSLAB remaining fully operational after the impact. The test will have consisted of the impact of a roadworthy and fully laden vehicle weighing 7,500Kg (16,500 pounds) travelling at 50 Kph (30 mph) into a single HSLAB. The impact testing must have been carried out in accordance with PAS 68 and exceed the DoS test standard SD-STD-2.01 Rev A class K12/L3. In addition, the HSLAB will be able to cause sufficient damage to a 7500 kg vehicle travelling at 50kph so as to destroy the front suspension and main drive train of the vehicle rendering it inoperative. F.3 Speed of operation Standard operation speed will be between 8 and 12 seconds for either raising or lowering. In normal operation the HSLAB shall be capable of operating at 150 cycles per hour (100% duty cycling at 12 second settings) and must have been satisfactorily factory tested in a continuous run of 1,200 cycles. 4

G. QA G.1 Equipment Testing The manufacturer will have fully tested the HSLAB, Control System and Access Control equipment prior to despatch. These tests will be fully traceable to each unit despatched and must be transparent. The QA testing will include dimensional checks, workmanship quality and finish as well as full operational testing. Once fully tested, the HSLAB will be fitted with a nameplate bearing the manufacturers details, serial number and test date. The manufacturer s quality system must be certified to ISO 9001. G.2 Despatch The HSLAB will be packed ready for despatch with cardboard sheeting strapped to the outer casing for protection. The structure will be substantial enough to enable lifting from either below or above without incurring damage or warping. Two full sets of operation and maintenance manuals will be provided with the equipment to include site specific program, wiring and installation drawings (additional manuals should be available at a nominal cost). H. Disclaimer This type of equipment is designed for high security use and while it is possible to integrate a number of safety features into the system design, it is generally better to provide adequate traffic calming measures, signage, area illumination and traffic lights to warn users of the potential hazard. Avon Barrier Corporation Ltd can provide information on safety systems to suit most sites / applications on request. It is strongly recommend that advice is taken from relevant security or safety engineers with regard to the system design, alternatively Avon Barrier Corporation would be pleased to provide such information contact our Security Department at our UK offices. 5

I. Procurement Source The EB950CR Armstrong High Security Lift Arm Barrier can be purchased from the following sources: Avon Barrier Corporation Ltd 149 South Liberty Lane Ashton Vale Bristol BS3 2TL UK Tel +44 117 9535252 Fax +44 117 9535373 Email sales@avon-barrier.co.uk 6