1. EXTERNAL ALARM MESSAGE



Similar documents
CNC MILLING MACHINE TROUBLE SHOOTING. 1. Trouble Shooting. No Trouble Solution. 1.Check the air pressure

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

101 COMM. FAILURE WITH MOCON/MOCON MEMORY FAULT

HIGH PRODUCTION DUAL DRIVE HORIZONTAL MACHINING CENTER

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

A.3 ALARMS (SERIAL SPINDLE)

DC-8706K Auto Dial Alarm System

REMOTE CONTROL MANUAL

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

How To Control A Car Alarm On A Car With A Remote Control System

USER S MANUAL HSC-24A

Fire Alarm Control Panel. Family. Operating Manual

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Fig 3. PLC Relay Output

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

PANASONIC TROUBLE SHOOTING GUIDE

IQAN MDM Operation Manual

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM

DUGARD. Machine Tools Since Dugard 700L Series Heavy Duty CNC Lathes.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

A/C-HEATER SYSTEM - AUTOMATIC

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

Hydraulic Trouble Shooting

CONTINUOUSLY VARIABLE TRANSMISSION (CVT)

14. Troubleshooting Guide

Pos. Qty. Article Descripiton Price /

Signature and ISX CM870 Electronics

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

Conventional Fire Detection and Extinguishant Control System Specification

6. Diagnostics for A/C System Malfunction

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

SAMSUNG Machine Tools

CNC LASER MACHINE (AMNC-F) ALARM LISTS

Electronic Manual Gearbox

How To Set Off An Alarm On A Car With A Car Alarm On It

AUTODIALLER / QUICKDIALLER - SA132

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

2.1 FOR Series 15i Servo Alarm TROUBLESHOOTING 2.ALARM NUMBERS AND BRIEF DESCRIPTIONS. Alarm No. SVM PSM Description Remarks

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

SAMSUNG Machine Tools

LAND ROVER MANUAL CONTENTS APPLICATIONS GENERAL OPERATION SPECIAL FUNCTIONS REMOTE CONTROL PROGRAMMING

1R / 4-BUTTON SERIES

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

GSM HOME SECURITY SYSTEM

WE-350 Series ¼ Turn Electric Actuator

Manual for Fire Suppression & Methane Detection System

Trouble shooting for die cast machine. customer service department of L.K Group

500r+ Installation and User Guide

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

Thermo Top - Troubleshooting Tree

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

MELDAS is a registered trademark of Mitsubishi Electric Corporation. Other company and product names that appear in this manual are trademarks or

Lebanese University Faculty of Engineering II. Final year project. Electrical Engineering Degree. Hady Zeinoun Antoine Zeidan. Cut to length line

Troubleshooting Guide for Jacks Down LED Lights

[9] TROUBLE CODE LIST

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Home Security Alarm System

Streaming Potential System (SPT1000, SPD1000)

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

GSM home alarm system s manual

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC

i ChatterBox! Motorcycle Security

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Fault Diagnosis and Maintenance for CNC Machine. Based on PLC

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

Business/ Home GSM Alarm System

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

OPL BASIC. Dosing System for Professional Laundry machines. Contents

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

ELECTRICAL WIRING (R.H. DRIVE VEHICLES)

Six-defense zone Display Alarm System. User Manual

Failure code manual. content

Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.

Operating Instructions. Single Loop Controller EC48 & EC96

Using your LED Plus keypad

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. FCC ID NOTICE

Electronic Pressure Switch EDS 3000

About Your System NOTE: What is included: Options and Accessories:

WRG EVENT CODE LISTING

UBM-W SERIES CNC HORIZONTAL BORING & MILLING MACHINE. CNC Double Column Machining Center UDM series

SECURITY SYSTEM ADP-CAN

Electro-Pneumatic Bus Door Control Mechanism

Table of Contents. General Operation 2. Air Blast Cleaning System 3. Setup 4. Changing Ticket Bags 5. Loading Printer Paper 6. Tower Light Status 7

Diagnostic Trouble Code (DTC) Charts

*.ppt 11/2/ :48 PM 1

SC-32 CNC LATHE OPERATION MANUAL

Dyeing Programmer DP - 01

CNC Milling Engraving machine G4030A Instruction manual

GSM Home Alarm System User Manual.

Business/Home GSM Alarm System. Installation and User Manual

DUGARD. DUGARD Machine. Dugard Heavy Duty Vertical Machining Centres. Machine Tools That Create Solutions Since Tools

Transcription:

. EXTERAL ALARM MESSAGE 00 SAFET DOOR EED CLOSE! ALARM 00 Is the safety door closed? Close the safety door. Is the window closed? Close the window. The diagnostic X8.=0. The limit switch (-A27) for the safety door or the window detects incorrectly. Please adjust it. 2. The limit switch (-A27) for the safety door or the window is defective. Please replace it. Press the RESET key. ED 8-2

003 SPIDLE MOTOR ALARM! ALARM 003. Please check the alarm number from C or the LED alarm number that displayed by spindle AMP. Please call for service 8-3

004 SPIDLE GEAR SHIFT ALARM! ALARM 004 Press the RESET button. 5 Is the machine with gear box? D57= D57=0 Consult Chap2 5.2 set. During maintenance? K4.7= Shift the gear box to HI (or LO) by execute Sxxxx. Shift to HI Shift to LO Is the gear HI solenoid valve O? (-306) Is the gear LO solenoid valve O? (-305) 2 3 4 Is the gear HI limit switch O? DG X5.6=0 X5.5= (S-302) Is the gear HI limit switch O? DG X5.6= X5.5=0 (S-303) 4 ED 8-4

2 3. In HI output DG3.0= 3.=0 In LO output DG 3.= 3.0=0 6 6 Cause: Condition error. Please command S-code again. 5 Cause:. The wiring of solenoid valve is poor contact. Please check the wiring. 2. The solenoid valve is defective. Please replace it. 3. The relay is defective. Please replace it. 5 4 Cause:. The limit switch for gear HI/LO detects incorrectly. Please adjust it. 2. The limit switch is defective. Please replace it. 5 8-5

005 ATC OT READ! (FOR ATC 24T 30T 32T 40T) ALARM 005 Change to the JOG mode Press the POT vertical button and release it to make the POT to the vertical position. Is the POT in the vertical position? DG 2.5= DG X6.2= X6.3=0 4 2 3 Is the Z axis at the tool change position? The diagnosis 7.0=(absolute) Keep to press manual ATC button Refer to ALM09 until cycle START button flashing. Start ATC change by press the cycle START button. 5 8-6

5 Is ATC start to change? DG 2.4= Is the ATC in the position after ATC change finish? 2 3 Press the POT vertical button and release it to make the POT to the horizontal position. Is the POT in the horizontal position? Press the EMG button and release it. 6 The diagnosis X6.2=0 X6.3= DG 2.6= 4 2 3 Press the RESET button Make sure the SPIDLE TOOL (The diagnosis D440) and EXT TOOL (The diagnosis C2) number are correct. ED 8-7

2 3 Cause:. The solenoid valve is defective. Please replace it. 2. The wiring of the solenoid valve is poor contact. Please check the wiring. 3. MAG locked. Please check it. 4. Parts interference. Please check it. Cause:. The button is defective. Please replace it. 2. The wiring of button is poor contact. Please check the wiring. 3. Condition error. Please reset again. 4 6 Cause: The limit switch is defective. Please replace it. The limit switch detects incorrectly. Please check it. Cause:. The limit switch for ARM detects incorrectly. Please check it. (ARM HOME X6.5, ARM BRAKE X6.4, TOOL U/CL COFIRM X6.6) 8-8

007 TF 0 COMMAD ERROR! ALARM 007 Wrong T command. Press the RESET key. Modify the T command 0 < T. ED 008 TF IS OTHIG I TOOL BOX! ALARM 008 Wrong T command. Press the RESET key. Correct the T command. ED 8-9

009 SERVO MOTOR ALARM! ALARM 009 Please close C power than open. Please check PMM MSG massage and consult Chap5 Appendix F eliminate. 00 SERVO MOTOR BATTER ALARM! ALARM 00 Please check PMM MSG massage and consult Chap5 Appendix F eliminate. ED 8-0

0 MAG (C0) SETTIG ERROR! ALARM 0 Press the RESET key. Set the diagnostic C0 with the total tool amount of the magazine. Consult Chap2 5.2 setting. End 02 POT (C2) SETTIG ERROR! ALARM 02 Press the RESET key. Set the diagnostic C2 with the tool no. on the standby pot. Consult Chap2 5.2 setting. End 8-

03 DOUBLE TOOL DETECTIO! ALARM 03 Press the RESET key. Check the standby pot no. equaling to the tool no. on the spindle. Set the correct pot no. (C2) Consult Chap2 5.2 setting. Remove the tool from the pot Try tool change M6 Txx again. Is the alarm still there? End. The sensor (S404) for tool detection is defective. Please replace it. 2. The sensor for tool detection is poor connected. Please check it. 8-2

04 SP. ORI ALARM! ALARM 04 Press refer to the parameter list attached with the machine to correct the C parameters o.4000~4099. Press the RESET key. Execute the M9 command of spindle orientation. Is the alarm still there? End 8-3

05 MOTOR OVERLOAD! ALARM 05 Please check the following motors whether there is overlod or fuse blown.. Motor of coolant pump (-F23) 2. Motor of chip conveyor (-F27, -F28) 3. Fuse on Lubricating unit (-A204) 4. Fuse on oil-air lubricating unit (-F239) 5. Motor of oil skimmer (-F234) 6. Motor of pump for coolant through spindle (-F200) 7. Motor of hydraulic unit (-F222) 8. Motor of pump for floor flushing (-F232) 9. Motor of spindle cooler (-A207) Solve the cause of overload. Press the resetting device on the overload relay Press the RESET key. End 8-4

06 SP. TOOL (D440) SETTIG ERROR! ALARM 06 Set the diagnostic D440 with the tool no. on the spindle. Consult Chap2 5.2 setting. Press the RESET key. End 08 M6 WITHOUT TF ALARM! ALARM 08 Modify the format of program as M6 Txx End 8-5

09 M6 SWAP POSITIO MISSED! ALARM 09 Press the RESET key. Is the function of automatic ATC position return used? (The unction for PMC axis) Is the spindle at the ATC position? Set diagnostic K.0= Please exectute the command of ATC position return before automatic tool change ATC. Is the servo motor incremental or absolute type? K2.2= is the incremental type. Wrong setting for the ATC position. Please refer to the following table to modify the parameter setting.. ATC position detection error, please adjust LS. (-S3) 2. ATC position LS damage please change the LS. (-S3) End 8-6

Roller gear type ATC Type Simple disk type Cam type of Roller gear type (Z axis for ATC Parameter (crank driving) single cycle (3 axes for ATC position ) position ) 24 X 0 0 0 ATC position. 0 0 0 ATC position. Z 0 0 0 ATC position. 696 0 0 0 697 3 0 0 2 698 3 3 3 3 6936 0 0 0 X coordinate of ATC position +250. 6937 The 2nd ATC position +250. 0 0 coordinate of ATC position +250. 3968 The st ATC position +250. 250 250 Z coordinate of ATC position +250. 6956 0 0 0 X coordinate of ATC position 250. 6957 The 2nd ATC position 250. 0 0 coordinate of ATC position 250. 6958 The st ATC position 250. -250-250 Z coordinate of ATC position 250. 800 X 0 0 0 0 0 0 Z The setting value varies according to the machine model. If the machine is with ISC system, all setting values of the ATC position must be the coordinate value multiplying 0 times. 8-7

020 SP.COOLIG LUBRICATIG SSTEM FAILED! ALARM 020 Is the spindle with oil-air lubrication or oil cooler? Set the diagnostic K3.0=. Is there oil cooler? Is the oil cooler with enough oil? Oil level of the oil cooler is too low. Please fill oil. (-A207) Is there oil-air lubrication? Diagnostic K8.2=?.Oil-air is too much. The amount needs to be adjusted 2. Wiring of the temperature switches (-F244, -F245) is poor contact. Please check the wiring. 3. The spindle motor is out of order. Please solve the cause.. The detector for oil level of the oil cooler (-A207) detects incorrectly. Pleae check it. End 8-8

02 TOOL MEASURE ALARM ALARM 02 Is it overtravel during tool length measurement? 2 Under the HADLE mode, move the spindle apart from the probe. Press lightly the detecting switch of the prober to get the red lamp lighting on. Diagnostic X7.4=0?. The cable for the element of the probe is poor connection or broken. Please check and replace the cable. 2. Some element of the probe (-A206) is defective, please replace the probe. Press lightly the detecting switch of the probe to check whether the returning signal (X4.7) is actuated.. The cable for the element of the probe is poor connection or broken. Please check and replace the cable. 2. Some element of the probe (-A206) is defective, please replace the probe. Press the RESET key. 2 End 8-9

022 TOOL LIFE EXHAUST ALARM 022 Counting of tool used (time or times) has been reached. Consult Chap4 5. setting. Press the RESET key. End 8-20

023 MAG OT IPOSITIO! 2 ALARM 023 Press the RESET key Is the POT in the horizontal position? The diagnosis X6.3= Is the magazine in the position? Change to the JOG mode 7 The diagnosis X6.3= Press the POT vertical button and release it to make the POT return to the horizontal position. Change to the JOG mode Is the POT in the horizontal position? Press the MAG CW/CCW button and release it to make the MAG rotate one 4 Is the MAG motor start? DG 2.6= 5 Is the MAG motor stop? 6 Cause:. The button of POT vertical is defective. Please replace it. 2. The wiring of POT vertical button is poor contact. Please check the wiring. 3 2 8-2

3 4. The wiring of the solenoid valve for POT H is poor contact. Please check the wiring. 2. The solenoid valve for POT H is defective. Please replace it. 3. The relay (K48, K49) damage. Please check it. 2 5 DG X6.3= Cause:. The limit switch for POT H detects incorrectly. Please check it. 2.The limit switch for POT H is defective. Please replace it. 2 2 The diagnosis 4.7= 6 Cause:. The MCC or relay of MAG Cause: CW/CCW is defective. Please. The wiring of MAG CW/CCW replace it. button is poor contact. Please check the wiring. 2. The wiring of MCC or relay for 2. The button of MAG CW/CCW MAG CW/CCW is poor contact. is defective. Please replace it. Please check the wiring. 3. The MAG motor is overload or damage. Please check it. 7 DG 4.7= DG C2 = at the present tool number Press the EMG button Cause:. The limit switch for MAG counter is defective. Please replace it. 2. The limit switch for MAG counter detects incorrectly. Please adjust it. 3.The relay (K404 K405) of MAG CW/CCW contacts incorrectly or damage. Please check it. 8-22

024 STC TEMP FAILED! ALARM 024 Press the RESET key Please check the signal of STC temperature card in the electrical cabinet. Finish. o 24V power input 2. STC temperature card is broken Please call for service 8-23

026 JIG EED CLAMP! ALARM 026 Is there optional JIG function? Set keeprelays K4.4=0 (M54 M55) K4.=0 (M56 M57) Is there APC function? Jig must be clamping during spindle rotation. 3 Press the RESET key. Do jig clamping by pressing the JIG CLAMP UCLAMP button or execute the command of jig clamping under the AUTO mode. Execute the command of spindle rotation. Is the alarm still there? 2 End 8-24

2 Is the jig clamped? Set timers T8=500 (M54 FIISH TIME) T20=500 (M55 FIISH TIME) T22=500 (M56 FIISH TIME) T24=500 (M57 FIISH TIME) Are limit switches used for detecting jig clamping unclamping?. Some limit switch on the jig is defective. Please replace it. (-S25, -S26, -S27, -S28) 2. Some limit switch on the jig detects incorrectly. Please adjust it. (-S25, -S26, -S27, -S28). The relay for jig is defective. Please replace it. (-K233, -K234, -K238, -K239) 2. The solenoid valve for jig clamping is defective. Please replace it. (-22, -23, -24, -25) 3. The wiring for the solenoid valve is poor contact. Please check the wiring. (-22, -23, -24, -25) 4. Some hydraulic pipe for jig clamping is clogged. Please clean the pipe or replace it. 8-25

3 Jig must be clamping during spindle rotation. Is there optional JIG function on the pallet A? Set keeprelays K4.4=0 (M54 M55) K4.=0 (M56 M57) Is there optional JIG function on the pallet B? Is the pallet A in the machining area? 4 Press the RESET key. Under the MDI or AUTO mode, execute the command for jig clamping (M54 M56) to do jig clamping. 6 Execute the command of spindle rotation. Is the alarm still there? End 5 8-26

5 Is the jig in the machining area clamping? Set timers T8=500 (M54 FIISH TIME) T20=500 (M55 FIISH TIME) T22=500 (M56 FIISH TIME) T24=500 (M57 FIISH TIME) Are limit switches used for detecting jig clamping unclamping?. Some limit switch on the jig is defective. Please replace it. (-S25, -S26, -S27, -S28) 2. Some limit switch on the jig detects incorrectly. Please adjust it. (-S25, -S26, -S27, -S28). The relay for jig is defective. Please replace it. (-K233, -K234, -K238, -K239) 2. The solenoid valve for jig clamping is defective. Please replace it. (-22, -23, -24, -25) 3. The wiring for the solenoid valve is poor contact. Please check the wiring. (-22, -23, -24, -25) 4. Some hydraulic pipe for jig clamping is clogged. Please clean the pipe or replace it. 6 8-27

4 Press the RESET key. Under the MDI or AUTO mode, execute the command for jig clamping (M58 M60) to do jig clamping. 7 Execute the command of spindle rotation. Is the alarm still there? End 2 8-28

027 AIR PRESSURE FAILED ALARM 027 Is the pressure of air source enough? Regulate the pressure of air source. Press the RESET key. Is the alarm still there? End. Wiring for air pressure detector(-a203) is incorrect. Please check the wiring. 2. Air pressure detector (-A203) isdefective. Please replace it. 8-29

028 ATC (D52) SETTIG ERROR ALARM 028 Is there magazine unit? ` Consult Chap2 5.2 setting. (D52) Re-start the machine. Make sure D52=99. End 8-30

029 SP TOOL CLAMPIG FAILED! ALARM 029 Press limit switches (S304, S305) for tool clamping and check whether the diagnostic X5.=.. The limit switch for tool clamping is defective. Please replace it. 2. The limit switch detects incorrectly. Please adjust it. 3. The wiring for limit switch is poor contact. Please check the wiring. 4. The wiring of rowed cable for CC is poor contact. Please check the rowed cable. End 8-3

030 MAG (D5) SETTIG ERROR! ALARM 030 Is there magazine unit? ` Consult Chap2 5. setting. (D5) Re-start the machine. Make sure D52=99. End 8-32

03 TOOL SEARCHIG FAILED ALARM 03 Tool searching cannot be finished in the defined time limit. Does the magazine rotate?. The limit switch for pot horizontal (S40) is defective. Please replace it. 2. The limit switch for pot horizontal detects incorrectly (X6.3). Please adjust it. 3. The wiring for pot horizontal is poor contact. Please check the wiring. 4. The contact of relay (K404,2.2) Execute the T command.. The limit switch (S40) for pot counter is defective. Please replace it. 2. The limit switch for pot counter detects incorrectly (X7.0). Please adjust it. 3. The wiring of limit switch for pot counter is poor contact. Please check the wiring Is the alarm still there? End 8-33

032 AUTO DOOR FAILED ALARM 032 The automatic door open close works over the set time limit. Timer T2=xxxx Refer to the article regarding setting Re-set the timer T2. 2 Is the automatic door closed? Diagnostic.6=. The limit switch (-S20, -S202) for automatic door is defective. Please replace it. 2. The limit switch (-S20, -S202) for automatic door detects incorrectly. Please adjust them. 2 Diagnostics X8.= X8.0=0 Press the RESET key. Execute the command of automatic door open close (M0 M). Is the alarm still there?. The automatic door gets interference. Please remove the obstacle. 2. The air pressure for the automatic door is too low. Please enlarge the pressure of the air source. 3. The solenoid valve (-207, -2) for automatic door is defective. Please replace it. 4. The wiring of the solenoid valve (-207, -2) for automatic door is poor contact. Please check the wiring 5. The relay (-K268, -K269) for automatic door is defective. Please replace it. 2 2 End 8-34

033 PAEL SETTIG ERROR! ALARM 033 Consult Chap2 5.2 setting. (D50). Re-start the machine. End 8-35

034 SPIDLE TOOLS OVERLOAD! ALARM 034 Press the RESET key Is the spindle tool broke or damaged The settings in spindle overload delay time (T48) is tool short, please refer to the timer setting of Chap2 5.. Change tool ED 8-36

035 WORKPIECE PROBER ERROR! ALARM 035 Press the RESET key Is the signal of prober and receiver are out off measure range? The diagnosis X7.7= Cause:. Is the prober or receiver broken? (-A206) 2. The wiring of prober and receiver is poor contact. Please check the wiring. Adjust the position of receiver. Setting the prober on spindle then move the z axis, make sure the signal can receive in full travel. ED 8-37

036 OIL AIR LUBE ERROR! ALARM 036 Is the oil level of the oil-air lubricating system too low? DG X5.7=? Is the air pressure for the oil-air lubricating system not enough? End Regulate the air pressure (referring to the mechanical maintenance manul). The pressure switch (-A203) is defective or poor contact. Please replace or check the wiring. 8-38

037 DC24V POWER SUPPL ERROR! ALARM 037 DC24V Power supply damage or wrong error, please change or check wiring. Press the RESET key. End 046 WORKPIECE PROBE LOW BATTER! ALARM 046 Cause: Workpiece probe battery life is too low or defective. Please change it. Press the RESET key ED 8-39

049 APC DOOR OP CL APC ARM TPE (TPE 3) (K4.6=, APC WITHOUT DOOR) ALARM 049 5 Diagnostics X3.= Close X3.0= Open Is the APC door opened? The APC door close is not finished in the defined time limit. 2 Is the APC door closed? 3 2 8-40

2 3. The limit switch (S536) for APC door open is defective. Please replace it. 2. The wiring of the limit switch for APC door open is connected incorrectly or circuit broken. Please check it and replace the broken one.. The limit switch (S537) for APC door close is defective. Please replace it. 2. The wiring of the limit switch for APC door close is connected incorrectly or circuit broken. Please check it and replace the broken one.. The solenoid valve (K50, K502) for APC door is defective. Please replace it. 2. The wiring of the solenoid valve for APC door is connected incorrectly or circuit broken. Please check it and replace the broken one. Diagnostic X3.= Close Press the RESET key. 3 Execute the command M9 M92 again. Is the alarm still there? End 5 8-4

049 APC DOOR OPE CLOSE FAIL β6 TPE(TPE 4) (K4.6=, APC WITHOUT DOOR) ALARM 049 5 Diagnostics X3.= Close X3.0= Open APC door close is not finished in the defined time limit. Is the APC door opened? 2 Is the APC door closed? 2 Select the JOG mode and press the APC DOOR OPE button. Is the APC door Closed? Diagnostics 6.= 6 3 4 8-42

2 3. The limit switch (S536) for APC door open is defective. Please replace it. 2. The wiring of the limit switch for APC door open is connected incorrectly or circuit broken. Please check it and replace the broken one.. The limit switch (S537) for APC door close is defective. Please replace it. 2. The wiring of the limit switch for APC door close is connected incorrectly or circuit broken. Please check it and replace the broken one.. The solenoid valve (K50, K502) for APC door is defective. Please replace it. 2. The wiring of the solenoid valve for APC door is connected incorrectly or circuit broken. Please check it and replace the broken one. 5 6 4 Diagnostic X3.= Close Press the RESET key. 2. The solenoid valve (K50, K502) for APC door is defective. Please replace it. 2. The wiring of the solenoid valve for APC door is connected incorrectly or circuit broken. Please check it and replace the broken one. End 5 8-43

050 TABLE CLAMP UCLAMP FAIL! ALARM 050 Is the EMERGEC STOP button released? Table clamping unclamping is not finished in the defined time limit. 2 Diagnostic 6.6= Diagnostic 6.7= Is the table is clamped? Is the table is unclamped? 5 3 5 4 8-44

3 4 5. The limit switch (S538) for table clamping is defective. Please replace it. 2. The wiring of the limit switch for table clamping is connected incorrectly or circuit broken. Please check it and replace the broken one. 3. The limit switch for table clamping detects incorrectly. Please adjust it.. The limit switch (S539) for table unclamping is defective. Please replace it. 2. The wiring of the limit switch for table unclamping is connected incorrectly or circuit broken. Please check it and replace the broken one. 3. The limit switch for table unclamping detects incorrectly. Please adjust it.. The solenoid valve (K504, K505) for table clamping unclamping is defective. Please replace it. 2. The wiring of the solenoid valve for table clamping unclamping is connected incorrectly or circuit broken. Please check it and replace the broken one. 2 Is the table is unclamped? Please release the EMERGEC STOP button.. 3 Please execute the command M85 to do table clamping.. Diagnostics X3.3= X3.4=0 3 Press the RESET key. End 8-45

05 APC Z AXIS EED RETE! ALARM 05 Execute zero return of the Z axis. Press the RESET key. End 8-46

054 APC SWAP TIME EXCEED ALARM 054 The APC pallet change is not finished in the defined time limit. Check limit switches. Pallet A - Locating pin locked (X3.7) 2. Pallet A - Locating pin unlocked (X4.0) 3. Pallet B - Locating pin locked (X4.) 4. Pallet B - Locating pin unlocked (X4.2) 5. Table clamping (X3.3) If anyone is defective, please replace it. Check solenoid valves. Table clamping (6.6), unclamping (6.7) 2. APC door open (6.0), close (6.) 3. Pallet A - Locating pin locked (7.) 4. Pallet A - Locating pin unlocked (7.0) 5. Pallet B - Locating pin locked (7.2) 6. Pallet B - Locating pin unlocked (7.3) Execute the command of pallet change. Is the alarm still there? End 8-47

057 ATC OT READ (FOR SIMPLE DISK TPE 20T) ALARM 057 Is the Z axis at the ATC position? Diagnostic F7.0= (Absolute type of servo motor) Please refer to the ALM09 to solve the problem. Is the magazine close to the spindle? Diagnostics X6.2=, X6.3=0 Select the JOG mode and press the TOOL UCLAMP button to do spindle tool unclamping. Before the magazine returns the standby position, make sure no tool will drop down. Or, remove tools on spindle or magazine. Is the spindle tool unclamped? 3 Diagnostics X5.2=, X5.=0 9 7 Select a manual mode to move the Z axis toward the positive direction until the Z axis getting the signal of interlock.f70.7= (Absolute type of servo motor). The limit switch (S305, S307) for spindle tool clamping unclamping is defective. Please replace it. 2. The limit switch for spindle tool clamping unclamping detects incorrectly. Please adjust it. 2 8-48

2 Press the EMERGEC STOP button and release it. Is the spindle tool clamped? Diagnostic 2.7 = 0 8 Diagnostics X5.=, X5.2=0 9 3 Select the JOG mode and press the MAG BACKWARD button to retract the magazine to the standy position. Does the magazine go backward? Diagnostic 2.3= Diagnostics X6.2=0, X6.3= 6 5 4 Set the spindle tool no. at the adress D440. Try commands M6 Txx again. 0 8-49

6 5 4. The limit switch (S404) for magazine backward is defective. Please replace it. 2. The limit switch for magazine backward detects incorrectly. Please adjust it.. The magnetic switch (K29) for magazine backward is defective. Please replace it. 2. The wiring of the magnetic switch for magazine backward is poor contact. Please check the wiring. 3. The magazine is jammed. Please repair it. The MAGAZIE BACKWARD button (S65) is defective. Please replace it. 2. The wiring of the MAGAZIE BACKWARD button is poor contact. Please check the wiring. 3. Conditions are not satisfied. Please check the setting. 7 8 Diagnostic 2.7=. The solenoid valve (32) for tool clamping unclamping is defective. Please replace it. 2. The wiring for tool clamping unclamping is poor contact. Please check the wiring.. The TOOL UCLAMP button (S638) is defective. Please replace it. 2. The wiring of the TOOL UCLAMP button is poor contact. Please check the wiring. 3. Conditions are not satisfied. Please check the setting. 0 Is the alarm still there? End 8-50

058 ATC DOOR OT CLOSES! (FOR DC ALARM 058 Press the RESET key 2 Execute the M78 command for close the ATC door Is ATC door close? The diagnostic 5.=. The ATC door gets DG X0.= interference. Please remove the obstacle. 2. The air pressure for ATC Cause:. The limit switch for ATC door is defective. Please replace it. (-S233) 2. The limit switch for ATC door detects incorrectly. Please adjust it. (-S233) 2 ED Is the alarm still there? door is too low. Please enlarge the pressure of the air source (-A203). 3. The solenoid valve is defective. Please replace it. (-40) 4. The wiring of the solenoid valve is poor contact. Please check the wiring. (-40) 5. The relay for POT is defective. Please replace it. (-K255) 2 8-5

059 TOOL MEASURE COVERS OT OPE! ALARM 059 Press the RESET key Execute the M20 command for open the tool measure cover Is the cover open? DG 4.5= (-20) Cause:. The limit switch for tool measure cover is defective. Please replace it. 2. Tool measurement is defective DG X.2= (A202) Cause:. The solenoid valve for tool measure cover is defective. Please replace it. (-20) 2. The wiring of the solenoid valve for tool measure cover is poor contact. Please check the wiring. (-20) 3. The relay for POT is defective. Please replace it. (-K228) ED 8-52

060 JIG CW/CCW OVERTIME! ALARM 060 Modify the setting of JIG CW/CCW timer consult Chap2 5. setting (T66) Is the alarm still there? ED Cause:. The limit switch for JIG CW/CCW is defective. Please replace it. 2. The limit switch for JIG CW/CCW detects incorrectly. Please adjust it. 8-53

06 M6 POT V ERROR! ALARM 06 Confirm the ATC type. Consult Chap2 During maintenance? K4.7= 4 Re-command M6 Is POT vertical? ED 8-54

The diagnostic 2.5=(-4) 4 Is POT vertical? DG X6.2= 4 Cause:. The POT gets interference. Please remove the obstacle. 2. The air pressure for POT is too low. Please enlarge the pressure of the air source (-A203). 3. The limit switch (-S4) for POT vertical is defective. Please replace it. 4. The limit switch for POT vertical detects incorrectly. Please adjust it. 5. Please check the wiring and signal. Cause:. The solenoid valve (-4) for POT is defective. Please replace it. 2. The wiring of the solenoid valve (-4) for POT is poor contact. Please check the wiring. 3. The relay (-K49) for POT is defective. Please replace it. 4 8-55

062 M6 ARM L.S ERROR! ALARM 062 Confirm the ATC type. Consult Chap2 During maintenance? K4.7= Re-command M6 Check the limit switch for ATC reference point, brake and spindle tool clamping/unclamping are correct. Cause:. The limit switch (-S46 S42 S45) is defective. Please replace it. 2. The limit switch detects incorrectly. Please adjust it. 3. Please check the wiring and signal. ED 8-56

063 M6 SPIDLE UCLAMP ERROR! ALARM 063 During maintenance? K4.7= Re-command M6 DG 2.7= Is the spindle tool unclamped? DG X5.= (-S306) ED Cause:. The air pressure for spindle tool clamping/ unclamping is too low. Please enlarge the pressure of the air source (-A203). 2. The limit switch (-S306) for spindle tool clamping/ unclamping is defective. Please replace it. 3. The limit switch for spindle tool clamping/ unclamping detects incorrectly. Please adjust it. 4. Please check the wiring and signal. Cause:. The solenoid valve (-302) for spindle tool clamping/ unclamping is defective. Please replace it. 2. The wiring of the solenoid valve (-302) for spindle tool clamping/ unclamping is poor contact. Please check the wiring. 3. The relay (-K32) for spindle tool clamping/ unclamping is defective. Please replace it. 8-57

064 M6 SPIDLE CLAMP ERROR! ALARM 064 During maintenance? K4.7= Re-command M6 DG 2.7=0 Is the spindle tool clamped? Cause: DG X5.= (-S304). The solenoid valve (-302) for spindle tool clamping/ unclamping is defective. Please replace it. Cause: 2. The wiring of the solenoid valve. The air pressure for spindle tool (-302) for spindle tool clamping/ clamping/ unclamping is too low. Please unclamping is poor contact. Please enlarge the pressure of the air source check the wiring ED (-A203). 2. The limit switch (-S306) for spindle 3. The relay (-K32) for spindle tool clamping/ unclamping is defective. tool clamping/ unclamping is defective. Please replace it. Please replace it. 3. The limit switch for spindle tool clamping/ unclamping detects incorrectly. Please adjust it. ` 4. Please check the wiring and signal. 8-58

065 OE TF COMMAD! ALARM 065 Enter T code instruct again. 068 IVERTER BREAKDOW ALARM ALARM 068 Inverter breakdown alarm check the LED displayed code of inverter Please refer to the inverter operation manual (maintain-error-reason-solution) for trouble shooting. ED 8-59

07 STC TEMP ERROR! ALARM 07 Press the RESET key Please check the signal is correct or not of STC temperature card in electrical cabinet. STC temperature sensor has been broken. Please call for service. Is the ALARM 07 still displaying Finish Please call for service 8-60

072 SP. TEMP ERROR! ALARM 072 Press the RESET key. Is the ALARM 072 still displaying Finish Press the RESET key after 0 minutes. Finish 8-6

073 SP. EED WARM UP! ALARM 073 Press the RESET key. Following the C process to run the warming up program. Continue working process after the warming up program completed. 8-62

900 PLEASE TUR OFF POWER! Please turn off the power ED 8-63