CTO Configuration Guide. Eaton Ferrups Ferrups 60Hz RM Series

Similar documents
Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

Product Snapshot. Powerware 5125 Family Uninterruptible Power System. Introducing the expanded Powerware 5125 family of UPSs.

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Eaton LanSafe Power Management Software

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Axxium - iseries (AS/400) Integration

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

QuickSpecs. HP 480/277 Volt Solutions. Overview

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Model #: SMART2200CRMXL

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Dell Smart-UPS 1,500 3,000 VA

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

Powerware Enclosure Solutions Product Focus

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

Smart-UPS On-Line 230 V

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Wireless Networks and Power Quality

Power Quality Solutions up to 40 kva. UPS product catalogue

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Powerware Relay-Serial Card User s Guide

Powerware series. Eaton 9155 UPS kva

PowerGem Pro Uninterruptible Power Supply

Distributing Power to Blade Servers

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

QuickSpecs. Compaq Uninterruptible Power Systems M ODELS

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Agilent 4339B/4349B High Resistance Meters

Galaxy VM. Three-phase power protection. schneider-electric.com

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

Uninterruptible Power Supply

Agilent 4338B Milliohm Meter

Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course Tripp Lite.

Release Notes: PowerChute plus for Windows 95 and Windows 98

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Rack Power Distribution

Eaton epdu Data Center Product Catalog

emcomp s.r.o. G E D ig ita l E n e rg y Stolní záložní zdroje VICTRON GE Digital Energy ML/Match - Pluggable single phase line-interactive UPS

LAP ENERGIA PARA DATACENTERS

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

Internet Office 500VA Tower Standby 120V UPS with USB port

Eaton epdu. Intelligent and flexible power distribution

PE8216/PE8324. Energy Intelligence Solutions

Rack Power Distribution. Worldwide

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Compaq Rack Options and Accessories. Monitors and Keyboards

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

46120-F0 Solar Energy Training System

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

R5000 Uninterruptible Power System (UPS) Overview

Powerware 5110 UPS User s manual

Agilent E5063A ENA Series Network Analyzer

R5000 Uninterruptible Power System (UPS) Overview

10000HXL31/15000HXL31/20000HXL31

Powerware series. Eaton 9155 UPS kva

High-Efficiency AC Power Distribution for Data Centers

BC Pro UPS System Standby UPS System

Panduit Infrastructure Management Software for Data Centers and Enterprises

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

TrueAlarm Fire Alarm Systems

SMART Board interactive whiteboard system projectors

Phase Modular Finally the benefits of Modular ups are for all

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

Eaton NetWatch v5.0 NetWatch on Microsoft Hyper-V server 2008 Installation and configuration guide

PowerCommand iwatch 100 Remote Network Monitoring

HP Port Switches Quick Setup Guide

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

Remote Monitoring and REC 501 Control Unit Product Guide

remote monitoring system Compass RMS remote monitoring system

Power Commander Power Distribution Units from Wiremold/Legrand offer

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

RT5kVA and RT6kVA 3U Rack or Tower Uninterruptible Power Supplies Product Guide

MAJORSINE Power Inverter

NGSS Data Consolidator (DC)

The Different Types of AC Power Connectors in North America

Agilent 87421A/87422A Power Supply

Comparison SMART Board Interactive Whiteboard Systems. Models SB600i2, SB600i3 and SB685ix

IBM 11000VA LCD 5U Rack Uninterruptible Power Supply IBM System x at-a-glance guide

Transcription:

CTO Configuration Guide Eaton Ferrups Ferrups 60Hz RM Series FER5GDE July,, 203

Table of Contents Ferrups CTO Worksheet..2 Ferrups 60Hz Rackmount Series Quick Reference Sheet.. 3 Ferrups CTO Details FES.4kVA...4k- FER2.kVA 2.k- FER3.kVA 3.k- FER7kVA 7k- Additional Ferrups External Options 4 Voltage Matching Transformers Connectivity Options Software

Configuring Your FERRUPS UPS FERRUPS must be ordered using a Configure To Order (CTO) Number that reflects the cabinet style, VA rating, voltages, runtime, and other options pertaining to the FERRUPS configuration. As you select the options needed, they will become part of the CTO number. Sample CTO Number: RI000AA0A0A0A0A. External battery packs, bypass switches and other external options should be ordered as separate items. The UPS CTO Worksheet UPS CTO Order Code List Price Discount Net Price Base Unit R_ Input / Output Voltage Battery and Battery Charger Internal Maintenance Bypass Switch Input Connection Output Connection Internal Options Complete UPS CTO Number R_ External Battery Pack Battery Pack Selected: UPS Subtotal Other External Battery Options Selected: External Maintenance Bypass Switch External Maintenance Bypass Switch Selected: Other External Options Note: Eaton offers a complete line of Power Distribution Units (PDUs). Please contact your sales representative or visit our website, powerquality.eaton.com and www.epdu.com details. 2 Sub Total Freight Insurance Tax/Duty Quote Total

Ferrups 60Hz Rackmount Series Quick Reference Note: Not all options are available on each base unit. Options restrictions exist. Please consult information in this guide for further detail. RI 0 0 0 A A0A0A0A0 A Base Unit (-2) RC =.4kVA RH = 2.kVA RI = 3.kVA RK = 7.0kVA Input/Output Voltage (3) 0 = 20V in; 20V out = 208V in; 20/208V out 2 = 208V in; 20/240V out 3 = 240V in; 20/240V out 6 = 240V in; 240V out Internal Bypass (5) 0 = None Input (6) A = Hardwired B = 5-5P C = 5-20P D = 5-50P J = L5-30P K = L6-20P L = L6-30P Output (7-4) Type Qty A= None- HW 0 B= 5-5R Duplex C= 5-20R Duplex 2 E= 6-20R Duplex 3 G= L5-5R Duplex H= L5-20R I= L5-30R K= L6-20R L= L6-30R Battery / Battery Charger (4) 0 = Standard Battery/ Standard Charger 3 = Setup for Internal w/o Battery/ Std Charger 4 = External Battery/ Standard Charger 5 = External Battery/ 0A Charger Enter receptacle types alphabetically, followed by the qty desired, and complete necessary digits with A0 Internal Options (5) A = None B = AVR/ DVR (recommended for PFC loads) Q = Neutral to ground bond removal (shipboard) R = Neutral to ground removed & AVR/DVR 3

FES.4kVA CTO Configuration Guide Ferrups.4kVA 60Hz Rackmount General Specifications Capacity:.4kVA/.0kW Dimensions: 0.5 (6U) x 9 x 2.25 Input Voltage: 20V (HxWxD) 267mm x 483mm x 540mm Output Voltage: 20V Weight (with batteries ): 50 lb / 68 kg Weight (without batteries): 98 lb / 45 kg See Eaton Ferrups Rackmount Series 60Hz Datasheet (LTP0224) for additional product specification.. Weights are approximate for standard batteries, option 0 for digit 4. Base Unit Digits -2 Base Model, Frequency, Cabinet Style CTO Order Code Base Price FER.4kVA, 60 Hz Rackmount RC $5,988 Input / Output Voltage Digit 3 Input Voltage Output Voltage CTO Order Code Base Price 20 20 0 $0 Battery and Battery Charger Digit 4 Battery Configuration Battery Charger CTO Order Code Option Price 4 minute internal (36m half load) standard 0 $437 Set up for internal (less batteries) standard 3 $08 Internal Maintenance Bypass Switch Digit 5 Internal Maintenance Bypass Switch CTO Order Code Option Price No internal maintenance bypass switch option available 0 $0 External maintenance bypass switch available for hardwired systems. Order desired maintenance bypass switch as a separate line item on your order. See page.4k-2. Input Connection Digit 6 Input Voltage Selected Input Connection CTO Order Code Option Price Hardwired A $0 Any 5-5P w/6 Line Cord B $24 Hardwired input requires hardwired output.4k -

FES.4kVA CTO Configuration Guide Output Connection Digits 7-4 Designated by 8 digits within the unit CTO number. These eight digits allow selection of the type and quantity of receptacles. Output Voltage Required Output Connection CTO Order Code Option Price 20 volt Hardwired A0A0A0A0 $0 20 volt 5-5R Duplex B2A0A0A0 $00 Hardwired output requires hardwired input Internal Options Digit 5 Internal Options CTO Order Code Option Price No other option A $0 AVR (recommended when loads contain PFC power supplies) B $85 Neutral to Ground bond removal (For Shipboard Use) Q $25 Neutral to Ground bond removal and AVR (For Shipboard Use) R $0 External Options External bypass switches and other external options are not a part of the CTO number and will need to be ordered as separate line items. Some external options require that the UPS be configured for use with the option. More options are listed in the Additional External Options section of this guide. External Maintenance Bypass Switches (Recommended for hardwired units) UPS Input Voltage Switch Type Order Number List Price MBB (Make Before Break) BPE0MBBA $63 20 MBB, with AS/400 (iseries) Option BPE0MBBASA $657 Bypass Switch must be mounted on the wall near the UPS..4k - 2

FER2.kVA CTO Configuration Guide Ferrups 2.kVA 60Hz Rackmount General Specifications Capacity: 2.kVA/.5kW Dimensions: 0.5 (6U) x 9 x 26.25 Input Voltage: 20V (HxWxD) 267mm x 483mm x 667mm Output Voltage: 20V Weight (with batteries ): 220 lb / 00 kg Weight (without batteries): 6 lb / 53 kg See Eaton Ferrups Rackmount Series 60Hz Datasheet (LTP0224) for additional product specification.. Weights are approximate for standard batteries, option 0 for digit 4. Base Unit Digits -2 Base Model, Frequency, Cabinet Style CTO Order Code Base Price FER2.kVA, 60 Hz Rackmount RH $6866 Input / Output Voltage Digit 3 Input Voltage Output Voltage CTO Order Code Base Price 20 20 0 $0 Battery and Battery Charger Digit 4 Battery Configuration Battery Charger CTO Order Code Option Price 24 minute internal (58m half load) standard 0 $70 Set up for internal (less batteries) standard 3 $26 set up for external battery pack standard 4 $0 Includes External Battery Connector. Order desired external battery pack as a separate line. See page 2.k-3. Internal Maintenance Bypass Switch Digit 5 Internal Maintenance Bypass Switch CTO Order Code Option Price No internal maintenance bypass switch option available 0 $0 External maintenance bypass switch available for hardwired systems. Order desired maintenance bypass switch as a separate line item on your order. See page 2.k-2. Input Connection Digit 6 Input Voltage Selected Input Connection CTO Order Code Option Price Hardwired A $0 20 volt 5-20P w/6 Line Cord C $39 Hardwired input requires hardwired output 2.k -

FER2.kVA CTO Configuration Guide Output Connection Digits 7-4 Designated by 8 digits within the unit CTO number. These eight digits allow selection of the type and quantity of receptacles. Output Voltage Required Output Connection CTO Order Code Option Price 20 volt Hardwired A0A0A0A0 $0 (3) 5-5R Duplex B3A0A0A0 $50 (3) 5-20R Duplex (UL) C3A0A0A0 $50 Hardwired output requires hardwired input with maximum of two output connections Internal Options Digit 5 Internal Options CTO Order Code Option Price DVR B $0 Neutral to Ground bond removal and DVR (For Shipboard Use) R $25 External Options External battery packs, bypass switches and other external options are not a part of the CTO number and will need to be ordered as separate line items. Some external options require that the UPS be configured for use with the option. More options are listed in the Additional External Options section of this guide. External Battery Packs Runtime Full/Half Battery Charger Required Order Number List Price h4m/3h54m Standard Battery Charger re $4,428 2h50m/6h37m Standard Battery Charger 2re $7,685 UPS must be ordered set up for external battery pack. See page 2.k-. External Battery Accessories Option Order Number List Price External Battery Connector Extension (72 ) Also recommended for third-party external battery configurations. BCS-008 $24 External Maintenance Bypass Switches (Recommended for hardwired units) UPS Input Voltage Switch Type Order Number List Price MBB (Make Before Break) BPE0MBBA $63 20 MBB, with AS/400 (iseries) Option BPE0MBBASA $657 Bypass Switch must be mounted on the wall near the UPS. 2.k - 2

FER3.kVA CTO Configuration Guide Ferrups 3.kVA 60Hz Rackmount General Specifications Capacity: 3.kVA/ 2.2kW Dimensions: 0.5 (6U) x 9 x 26.25 Input Voltage: 20, 208, 240 V (HxWxD) 267mm x 483mm x 667mm Output Voltage: 20, 20/208, 20/240, Weight (with batteries ): 238 lb / 08 kg 240, 27/240 V Weight (without batteries): 38 lb / 63 kg See Eaton Ferrups Rackmount Series 60Hz Datasheet (LTP0224) for additional product specification.. Weights are approximate for standard batteries, option 0 for digit 4. Base Unit Digits -2 Base Model, Frequency, Cabinet Style CTO Order Code Base Price FER3.kVA, 60 Hz Rackmount RI $7,622 Input / Output Voltage Digit 3 Input Voltage Output Voltage CTO Order Code Base Price 20 20 0 $0 208 20/208 $50 208 20/240 2 $50 240 20/240 3 $50 240 240 (International Models) 6 $50 Battery and Battery Charger Digit 4 Battery Configuration Battery Charger CTO Order Code Option Price 4 minute internal (35m half load) standard 0 $695 Set up for internal (less batteries) standard 3 $26 set up for external battery pack standard 4 $0 Includes External Battery Connector Order desired external battery pack as a separate line. See page 3.k-3. Internal Maintenance Bypass Switch Digit 5 Internal Maintenance Bypass Switch CTO Order Code Option Price No internal maintenance bypass switch option available 0 $0 External maintenance bypass switch available for hardwired systems. Order desired maintenance bypass switch as a separate line item on your order. See page 3.k-4. Input Connection Digit 6 Input Voltage Selected Input Connection CTO Order Code Option Price Any Hardwired A $0 20 volt 5-50P w/6 Line Cord D $90 L5-30P w/6 Line Cord J $77 208 or 240 volt L6-20P w/6 Line Cord K $77 L6-30P w/6 Line Cord L $77 Hardwired input requires hardwired output 3.k -

FER3.kVA CTO Configuration Guide Output Connection Digits 7-4 Designated by 8 digits within the unit CTO number. These eight digits allow selection of the type and quantity for up to four different types of receptacles. Three output slots available with line cord input connection. For multiple quantities of one receptacle type, enter the type once with the total quantity (ex: B2 not BB). Always enter the receptacle types alphabetically (ex: BC not CB). If hardwire output is desired, select type A, quantity 0 for all four receptacle types (ex: A0A0A0A0). If fewer than three types of receptacle are selected, complete the remaining receptacle digits with A0 (ex: BCA0A0). Output Voltage Required Output Connection CTO Order Code Option Price Type Qty per Panel Any Hardwired A 0 $0 20 volt 5-5R Duplex B $50 Choose up to three panels 5-20R Duplex (UL) C $50 208, or 240 volt Choose up to three panels 6-20R Duplex E $75 L5-5R Duplex G $75 20 volt Choose up to three panels L5-20R H $75 L5-30R I $75 208, or 240 volt L6-20R K $75 Choose up to three panels L6-30R L $75 Receptacle Output Connection CTO Order Code A 0 Hardwire Output Connection CTO Order Code A 0 A 0 A 0 A 0 Hardwired output requires hardwired input Internal Options Digit 5 Internal Options CTO Order Code Option Price DVR B $0 Neutral to Ground bond removal and DVR (For Shipboard Use) R $25 3.k - 2

External Options FER3.kVA CTO Configuration Guide External battery packs, bypass switches and other external options are not a part of the CTO number and will need to be ordered as separate line items. Some external options require that the UPS be configured for use with the option. More options are listed in the Additional External Options section of this guide. External Battery Packs Runtime Full/Half Battery Charger Required Order Number List Price 57m/2h27m Standard Battery Charger re $4,428 h4m/4h03m Standard Battery Charger 2re $7,685 UPS must be ordered set up for external battery pack. See page 3.k-. External Battery Accessories Option Order Number List Price External Battery Connector Extension (72 ) Also recommended for third-party external battery configurations. BCS-008 $24 External Maintenance Bypass Switches (Recommended for hardwired units) UPS Input Voltage Switch Type Order Number List Price 20V MBB (Make Before Break) BPE0MBBA $63 MBB, with AS/400 (iseries) Option BPE0MBBASA $657 208V BBM (Break Before Make) BPE02BBMA $865 BBM with AS/400 (iseries) Option BPE02BBMASA $904 240V MBB (Make Before Break) BPE02MBBA $865 MBB with AS/400 (iseries) Option BPE02MBBASA $904 Bypass Switch must be mounted on the wall near the UPS. 3.k - 3

FER7kVA CTO Configuration Guide Ferrups 7.0kVA 60Hz Rackmount General Specifications Capacity: 7.0kVA/ 5.0kW Dimensions: 9.25 (U) x 9 x 26.25 Input Voltage: 208, 240 V (HxWxD) 489mm x 483mm x 540mm Output Voltage: 20/208, 20/240, 240 Weight (with batteries ): N/A Weight (without batteries): 330 lb / 50 kg See Eaton Ferrups Rackmount Series 60Hz Datasheet (LTP0224) for additional product specification.. Weights are approximate for standard batteries, option 0 for digit 4. Base Unit Digits -2 Base Model, Frequency, Cabinet Style CTO Order Code Base Price FER7kVA, 60 Hz Rackmount RK $5,879 Input / Output Voltage Digit 3 Input Voltage Output Voltage CTO Order Code Base Price 208 20/208 $0 208 20/240 2 $0 240 20/240 3 $0 240 240 (International Models) 6 $0 Battery and Battery Charger Digit 4 Battery Configuration Battery Charger CTO Order Code Option Price set up for external battery pack standard 4 $0 set up for external battery pack 0 amp internal upgrade 5 $270 Order desired external battery pack as a separate line. See page 7k-3. Internal Maintenance Bypass Switch Digit 5 Internal Maintenance Bypass Switch CTO Order Code Option Price No internal maintenance bypass switch option 0 $0 External maintenance bypass switch also available for hardwired systems. Order desired maintenance bypass switch as a separate line item on your order. See page 7k-3. Input Connection Digit 6 Input Voltage Selected Input Connection CTO Order Code Option Price Any Hardwired A $0 7k -

FER7kVA CTO Configuration Guide Output Connection Digits 7-4 Designated by 8 digits within the unit CTO number. These eight digits allow selection of the type and quantity for up to three different types of receptacles. Up to three output slots available. For multiple quantities of one receptacle type, enter the type once with the total quantity (ex: B2 not BB). Always enter the receptacle types alphabetically (ex: BC not CB). If hardwire output is desired, select type A, quantity 0 for all four receptacle types (ex: A0A0A0A0). If fewer than three types of receptacle are selected, complete the remaining receptacle digits with A0 (ex: BCA0A0). CTO Order Code Option Price Output Voltage Required Output Connection Type Qty per Panel Any Hardwired A 0 $0 5-5R Duplex B $50 20 volt 5-20R Duplex (UL) C $50 208 or 240 volt 6-20R Duplex E $75 20 volt 208 or 240 volt L5-5R Duplex G $75 L5-20R H $75 L5-30R I $75 L6-20R K $75 L6-30R L $75 Receptacle Output Connection CTO Order Code A 0 Hardwire Output Connection CTO Order Code A 0 A 0 A 0 A 0 Hardwired output requires hardwired input Internal Options Digit 5 Internal Options CTO Order Code Option Price DVR B $0 Neutral to Ground bond removal and DVR (For shipboard use) R $25 7k - 2

External Options FER7kVA CTO Configuration Guide External battery packs, bypass switches and other external options are not a part of the CTO number and will need to be ordered as separate line items. Some external options require that the UPS be configured for use with the option. More options are listed in the Additional External Options section of this guide. External Battery Packs Runtime Full/Half Battery Charger Required Order Number List Price 2m/33m Standard Battery Charger EBPS4.3R $4,35 0 Amp Battery Charger Upgrade Optional Order battery charger as part of UPS. See page 7k-. External Maintenance Bypass Switches (Recommended for hardwired units) UPS Input Voltage Switch Type Order Number List Price 208, 220 volt BBM (Break Before Make) BPE02BBMA $865 BBM with AS/400 (iseries) Option BPE02BBMASA $904 240 volt MBB (Make Before Break) BPE02MBBA $865 MBB with AS/400 (iseries) Option BPE02MBBASA $904 Bypass Switch must be mounted on the wall near the UPS. 7k - 3

Additional Ferrups External Options Voltage Matching Transformers 208V in 20/240V out (required for applications using MBB bypass with source voltage of 208V) Transformer Description For use with Ferrups models: Order Number List Price 7.5kVA Transformer RK (7kVA) TRN-0239 $2,3 Connectivity Option Order Number List Price Hand-held Remote Control Panel with Cable RCK-0007 $363 IBM AS/400 (iseries) Interface Kit UPS w/o maintenance bypass switch IPK-000 $24 Serial RS-232 CheckUPS Cable DB25M to DB9F INT-0035 $ 63 BestLink SNMP/WEB Adapter 6750225-00 $349 Software Arriving bundled with every Ferrups UPS is the Eaton Intelligent Power Software Suite. The software suite includes links to LanSafe and NetWatch software. Eaton s latest release of our free LanSafe software is fully supportive of the Ferrups product line. Ferrups customers can use LanSafe to deliver comprehensive UPS support including graceful, remote shutdown of UPS systems and network monitoring tools via a serial connection. The most recent release of LanSafe software is available for download on our website powerquality.eaton.com. NetWatch Clients UPS software enables users to shutdown a server or workstation and acts as a network-monitoring tool through the BestLink SNMP/WEB Adapter that monitors and controls it. During an extended power outage, the SNMP/WEB adapter informs all registered NetWatch Clients that it is time to shut down their respective operating systems, thus preparing them for the removal of AC power. Ferrups products are also compatible with the Eaton PowerXpert Software, geared toward end users with mostly Eaton power distribution products such as switchgear, UPSs, breakers, PDUs, RPPs, meters, and relays amongst others. PowerXpert has web based views including Trend Viewer, Layout Manager and Quality Manager Modules. Additionally, the CheckUPS Software Suite is available for download under legacy software at powerquality.eaton.com. This product remains in Eaton's portfolio and is still used in a number of applications but is not under further development. For more information on Eaton software products, visit powerquality.eaton.com/support/software-drivers 4

UNITED STATES 8609 Six Forks Road Raleigh, NC 2765 U.S.A. Toll Free:.800.356.5794 Or 99.872.3020 powerquality.eaton.com www.eaton.com CANADA Ontario: 46.798.02 LATIN AMERICA Argentina: 54..4343.6363 Brazil: 55..366.8500 Mexico: 52.55.5488.5252 EUROPE/MIDDLE EAST/AFRICA Denmark: 45.3686.790 Finland: 358.94.52.66 France: 33..602.7400 Germany: 49.784.666.0 Italy: 39.02.66.04.05.40 Norway: 47.23.03.65.50 Sweden: 46.8.598.940.00 United Kingdom: 44.753.608.700 ASIA PACIFIC Australia/NZ: 6.2.9878.5000 China: 86.2.636.5599 HK/Korea/Taiwan: 852.2745.6682 India: 9..2649.944 to 8 Singapore/SEA: 65.6829.8888 Powerware and ABM are trade names, trademarks and/or service marks of Eaton Power Quality Corporation or its subsidiaries and affiliates. All other trademarks are property of their respective owners. 2007 Eaton Corporation All Rights Reserved PDF Only Configuration Guide July, 203