AC500. Software Description. Scalable PLC for Individual Automation. Installation of the AC500 Control Builder PS501



Similar documents
TSX ETZ Configuration of your computer for TSX ETZ direct connection by serial link. Eng V1.0

SYNERGY CONFIGURATION SOFTWARE AND HARDWARE SETUP V /02

Release Notes OPC-Server V3 Alarm Event for High Availability

1. Requirements for Network Installation on 840D

Chapter 3 Software Installation

Chapter 2 Installation

VCI - Virtual CAN Interface VCI-V2 Installation Manual

Installing the Gerber P2C Plotter USB Driver

82341C HPIB Installation and Troubleshooting Windows 95 and Windows NT CE, GC, LC and A/D ChemStation, Version A.05.0x and A.06.0x

End-User troubleshooting guide For Sentinel SuperPro/UltraPro and Sentinel Hardware Keys

How To Install The Safenet-Inc.Com Software On A Pc Or Mac Or Macintosh (For A Powerpoint) With A Powerline (For Windows) Or Ipad (For Mac) With The Safetime (For Pc

WPA-LON Series WPA-LON-1. Application. Model Chart WPA-LON-2 WPA-LON-3. Adapter Card Software

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

Appendix C I/O Hardware Installation

SOFTWARE INSTALLATION INSTRUCTIONS

Serial ATA 2 Ports PCI Host

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Software Manual Virtual COM for USB Driver / Configuration Tool

GE Healthcare Life Sciences UNICORN Administration and Technical Manual

Title Page. Installation Guide. PowerChute plus Version for Windows 95

Iridium Extreme TM Satellite Phone. Data Services Manual

Installing MPU-401 Compatible Cards in Windows 95

FANUC Open CNC. Setup procedure for Windows 95/NT 4.0

Chapter 1 Downloading Images to Your Computer (Windows)

File Management Utility. T u t o r i a l

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

Serial ATA RAID PCI. User's Manual

DeviceNet Communication Card

drive atapi User s Guide Operating Your Zip Drive Zip Tips Iomega Tools Software Special Information for Windows NT, Windows 95, and Windows/DOS

Promise FastTrak 100-Lite RAID Controller

SA-9600 Surface Area Software Manual

Maintaining the Content Server

Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright Lismore Software Systems, Ltd. All rights reserved.

Operating Instructions Serial Monitor ROBERT RIELE GmbH & Co KG

2-Serial/1-Parallel Port PCI Adapter RC303 User Manual

User s Guide for version 5 Page

Config software for D2 systems USER S MANUAL

RDC-7 Windows XP Installation Guide

NEC Versa Dock Important Information. Updating the BIOS. Before Docking for the First Time. Windows 95 and 98. Note

Contents. Hardware Configuration Uninstalling Shortcuts Black...29

3. Installation for Windows 95/98/NT4. 1. Introduction

Installation Instruction STATISTICA Enterprise Small Business

Galileo Print Manager

How to install the RTL8029 PCI Adapter Boot Rom for Windows95

Centurion PLUS CPC4 Download Guide

Promise RAID Function

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Wireless LAN g USB Adapter

Installing ABACUS ELECTRICS USB Optical Probes under Windows 7

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

DUKANE Intelligent Assembly Solutions

Printer Support Guide. FedEx Ship Manager Software

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

GETTING STARTED. Please turn to the correct section for your operating system

GW-7552 PRIFIBUS/MODBUS GATEWAY

Operating Instructions

CashFlow Programming Module CPM

13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES

ISK 200 Driver Installation

Moxa Device Manager 2.3 User s Manual

CANON FAX L360 SOFTWARE MANUAL

WindO/I-NV2 Utility Pass-Through Tool

SQL Server 2008 R2 Express Edition Installation Guide

Installing the Microsoft Network Driver Interface

Topaz Installation Sheet

WinPFT File Transfer Utility (Catalog No ND7)

Operating Instructions

Installing PowerLink on Windows 7 64-bit

Centran Version 4 Getting Started Guide KABA MAS. Table Of Contents

CODESOFT Installation Scenarios

General FAQ s E-Pos Systems.

Guide to Installing BBL Crystal MIND on Windows 7

PCI/PXI ETHERNET ADAPTERS

Chapter 25 Backup and Restore

VERITAS Backup Exec TM 10.0 for Windows Servers

SOFTWARE INSTALLATION MANUAL

Host Connectivity Kit PVCAM for PI Cameras Installation

Low Profile Ultra ATA-133 RAID PCI Host

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

Inmagic ODBC Driver 8.00 Installation and Upgrade Notes

PnP Driver Installation

Secure Perfect RAID Recovery Instructions

System Requirements. Hiro H50113

SAPIP GUI INSTALLATION. Table of Contents

PAMS Technical Documentation NHM 7 Series Transceivers. Service Software & Concepts

Korosi Monitoring System (KMS) Software Manual

User Installation Guide for SAS 9.1 Foundation for 64-bit Microsoft Windows

HL2170W Windows Network Connection Repair Instructions

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

ScanWin Installation and Windows 7-64 bit operating system

Installation Guide: Delta Module Manager Launcher

Dual Ports Serial PC Card User Manual

64-Bit Compatibility with Micromeritics Applications

Windows 95 Revision B Installation Instructions

Matisse Installation Guide for MS Windows. 10th Edition

USB PC Adapter V4 Configuration

GERBER EDGE USB-to-Parallel Option Kit

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

Transcription:

Software Description AC500 Scalable PLC for Individual Automation Installation of the AC500 Control Builder PS501 CM572 PM581 DC532 AX522

Contents Installation of the AC500 Control Builder 1 Contents of the CD of the Control Builder PS501 V1.x... 2 1.1 The CD menu... 2 1.2 The installation menu of the Control Builder PS501... 3 1.2.1 Order of sequence of the installation... 4 1.2.2 Installation of the Control Builder... 4 1.2.3 Installation of the Fieldbus Configurator SYCON.net... 5 1.3 Deinstallation of the Software... 5 1.3.1 Deinstallation of the Control Builder... 5 1.3.2 Deinstallation of the Fieldbus Configurator SYCON.net... 6 2 Notes regarding the settings of the serial PC interface... 7 2.1 Settings of the serial interface under Windows 2000... 7 3 Installation of ARCNET cards... 9 3.1 Overview of supported ARCNET cards... 9 3.2 Installation of ARCNET cards under Win2000 / XP... 9 3.2.1 SH ARC PCI - ARCNET card for PCI bus under Win2000 / XP... 9 3.2.2 SH ARC PCMCIA - ARCNET-PCMCIA card under Win2000 / XP... 10 3.2.3 SH FARC E3 [K] - ARCNET-Karte for ISA bus under Win2000 / XP... 11 4 Index... 14 V3 AC500 Installation Control Builder 1 PS501 AC500 / Issued: 08.2005

1 Contents of the CD of the Control Builder PS501 V1.x 1.1 The CD menu If "Autorun" is set for the CD-ROM drive on your PC, the CD-ROM menu is opened automatically. Otherwise, you can start it by executing the file "CD_Menu_V5x.exe" which is located in the root directory of the CD-ROM. For instance, select "Start" -> "Run" and then enter "[X]:\CD_Menu_V5x.exe" (where [x:] is the CD-ROM drive) to execute this file. The following menu is displayed: You can switch the user interface language by selecting the desired language from the "Please select language" list box. The CD-ROM contains the following menu pages: Read me first contains the "README_Vxx.TXT" file and the file "Content_CD_Vxx.TXT" which provides an overview of the contents of the Control Builder PS501 CD. Installation PS501 opens the installation menu. Documentation contains the complete AC500 / PS501 hard- and software documentation. V3 AC500 Installation Control Builder 2 PS501 AC500 / Issued: 08.2005

Examples contains an overview of example projects delivered with the CD-ROM. Internet Link Using this button you can access the ABB Internet site. Where to find us contains an overview of ABB STOTZ-KONTAKT GmbH sales offices. Click on the corresponding buttons to open the menu pages. By clicking on "Main menu" you can return to the title page at any time. Clicking the "Exit" button closes the CD-ROM menu. Buttons with gray labelling are not available in the present version. 1.2 The installation menu of the Control Builder PS501 The installation menu of PS501 is opened by clicking the button "Installation PS501". The following menu page is displayed: Clicking on "Read me for installation" displays the readme file containing additional information regarding the installation of the software. A short documentation of all example projects is opened by clicking on "Overview of examples". V3 AC500 Installation Control Builder 3 PS501 AC500 / Issued: 08.2005

Clicking the button "Documentation of examples" opens the documentation overview for the example projects. There you can access the individual documentations. The button "Readme Control Builder" displays the file "Readme_Vxx.txt" (or "Inhalt_CD_Vxx.txt") containing important notes for Version V.x.x. Buttons with gray labelling are not available in the present version. 1.2.1 Order of sequence of the installation The following installation menus are available: 1. Step 1: Installation of the Control Builder software 2. Step 2: Installation of the Fieldbus Configurator software SYCON.net 3. Opt. 1: Installation of the documantation If you require all components, carry out the installation following the order given above (steps 1-3). If only the programming software is required, you just have to install of the Control Builder (step 1). During the installation of the programming software, the communication drivers and the OPC server are installed as well. If the programming software 907 AC 1131 is installed and you encounter communication problems with an AC31/series 90 controller, you can use the button "907 AC 1131 / series 90 drivers for Win2000/XP" to install the communication drivers for the 907 AC 1131 V5.1 software. 1.2.2 Installation of the Control Builder The installation setup is started by clicking the button "Step 1: Installation Control Builder PS501". Follow the instructions given during the setup process. Caution: Administrative rights are required to install of the Control Builder software. The following system requirements must be fulfilled: - Windows 2000 or Windows XP - Internet Explorer 4.01 ("Version 4.72.2106.7" or higher) Registry: HKEY_LOCAL_MACHINE\Software\Microsoft\Internet Explorer\Version Not for Windows XP: If an error message regarding the Microsoft XML Parser appears during installation under Windows 2000, execute the file "msxml3.exe" located in the following directory on the CD: [x]:\cd_ac500\files_v10 By default, the Control Builder PS501 software is installed to the following directory: or C:\Programme\3S Software\CoDeSys V2.3\ C:\Program Files \3S Software\CoDeSys V2.3\ The installation includes all required files as well as the standard libraries, the OPC server and the communication drivers (gateway and driver dlls). V3 AC500 Installation Control Builder 4 PS501 AC500 / Issued: 08.2005

The target system files (TSP = Target Support Package) are installed to the following directory: C:\Programme\Gemeinsame Dateien\CAA-Targets\ABB_AC500\ or C:\Program Files \Common Files\CAA-Targets\ABB_AC500\ (See also System Technology CPUs/Target Support Package). Caution: If programming via ARCNET shall be used (possible as of Control Builder V2.0), the ARCNET card has to be installed first. The installation of the ARCNET driver is not performed automatically and is described in chapter "3.2 Installation of ARCNET cards". The drivers are located in the following directory of the CD: [X]:\CD_AC500\Dateien_Vxx\ARCNET (refer to chapter "Installation of ARCNET cards"). 1.2.3 Installation of the Fieldbus Configurator SYCON.net The installation setup is started by clicking the button "Step 2: Installation Fieldbus Configurator SYCON.net". Follow the instructions given in the setup. Caution: Administrative rights are required to install the Fieldbus Configurator software. By default, the Fieldbus Configurator software SYCON.net is installed to the following directory: or C:\Programme\Hilscher GmbH\SYCONnet\ C:\Program Files\Hilscher GmbH\SYCONnet\ installiert. The modules master data files (GSD files) for the PROFIBUS master coupler have to be installed to the following directory:. or C:\Programme\Hilscher GmbH\SYCONnet\ABBPBGenericSlaveDTM\GSD\ C:\Program Files\ Hilscher GmbH\SYCONnet\ ABBPBGenericSlaveDTM\GSD\ 1.3 Deinstallation of the software 1.3.1 Deinstallation of the Control Builder When uninstalling the Control Builder PS501 software you first have to exit the software and the gateway. In order to close the gateway, click with the right mouse button on the CoDeSys icon in the task bar of the operating system and select "Exit". If you also want to uninstall the target system files (TSP = Target Support Package), you have to uninstall these files prior to the uninstallation of the Control Builder software. To do so, execute the program "InstallTarget.exe" located in the same directory as CoDeSys.exe, highlight the entry "ABB STOTZ KONTAKT GmbH" in the right-hand window and then click on "Remove". V3 AC500 Installation Control Builder 5 PS501 AC500 / Issued: 08.2005

To uninstall the software in Windows 2000: Select "Start" => "Settings" => "Control Panel". Double click to open "Add or Remove Software". Highlight the entry "CoDeSys for Automation Alliance". Click on the "Remove" button and confirm the uninstall confirmation dialog with "Yes". All files and directories created during installation are deleted. If you have modified any directories and / or their content, these directories are not deleted. 1.3.2 Deinstallation of the Fieldbus Configurator SYCON.net When uninstalling the SYCON.net field bus configurator software you first have to exit the software and the gateway. In order to close the gateway, click with the right mouse button on the CoDeSys icon in the task bar of the operating system and select "Exit". To uninstall the software in Windows 2000: Select "Start" => "Settings" => "Control Panel". Double click to open "Add or Remove Software". Highlight the entry "ABB SYCON.net". Click on the "Remove" button and confirm the uninstall confirmation dialog with "Yes". All files and directories created during installation are deleted. If you have modified any directories and / or their content, these directories are not deleted. V3 AC500 Installation Control Builder 6 PS501 AC500 / Issued: 08.2005

2 Notes regarding the settings of the serial PC interface 2.1 Settings of the serial interface under Windows 2000 If the message "Communication error, logging out" is displayed when logging in via the serial interface, please check the connection between PLC and PC and the communication parameters in the menu "Online" / "Communication Parameters". If the connecting cables and the communication parameters are ok, please check the following settings for the serial interface. Settings for COM(x) under Windows 2000 (COM1 shown as an example): Select "Start" => "Programs" => "Accessories" => "System Tools"=> "System Information" and then select: "Hardware Resources": -> Conflicts/Sharing: no entry for COM1 -> I/O: 0x03F8-0x03FF Communications Port (COM1) Status: OK -> IRQs: 4 Communications Port (COM1) "Components" => "Ports" => "Serial (View/Simple)": Name: COM1 Status: OK.. (View/Advanced) Settable Baud Rate: True Settable Data Bits: True Settable Flow Control: True Settable Parity: True Settable Parity Check: True Settable Stop Bits: True... Baud Rate: 9600 Bits/Byte: 8 Stop Bits: 1 Parity: None Busy: 0... IRQ Number: 4 I/O Port: 0x03F8-0x03FF Driver: C:\winnt\system32\drivers\serial.sys "Software Environment" => "Drivers (View/Advanced)" Name = Serial Description = Serial port driver File = c:\winnt\system32\drivers\serial.sys Type = Kernel driver Started = True Start Mode = System State = Running Status = OK Error Control = Ignore Accept Pause = False Accept Stop = True V3 AC500 Installation Control Builder 7 PS501 AC500 / Issued: 08.2005

Select "Start" => "Settings" => "Control Panel" => double click on "System" =>. In the "Hardware" tab of the "System Properties" dialog select "Device Manager" and then double click on "Ports" => "Communications Ports (COM1)". In the "General" tab: -> Device Status = This device is working properly. -> Device Usage = Use this device (enable). "Port Settings": Bits per second = 9600 Data bits = 8 Parity = None Stop bits = 1 Flow control = None => "Advanced": Check the checkbox 'Use FIFO buffers' Receive Buffer: high Transmit Buffer: high COM Port Number: COM1 "Drivers" tab => "Driver details" => "Driver files": c:\winnt\system32\drivers\serenum.sys c:\winnt\system32\drivers\serial.sys "Resources" tab: Input/Output Range = 03F8-03FF Interrupt request = 04 Check the checkbox 'Use automatic settings' Conflict device list: No conflicts; V3 AC500 Installation Control Builder 8 PS501 AC500 / Issued: 08.2005

3 Installation of ARCNET cards 3.1 Overview of supported ARCNET cards Note: Support of ARCNET cards is available as of version V2.x. The following ARCNET cards are available for the programming of AC500 PLCs in the integrated ARCNET coupler. ARCNET card SH FARC E3 (K) (with COM20022) Bus type Operating system Driver file (on SoHard website) ISA Win2000/XP W2K_RAW_DRIVER_V0518.zip..\ARCNET\Win2000 SH ARC PCI PCI Win2000/XP W2K_RAW_DRIVER_V0518.zip..\ARCNET\Win2000 SH ARC PCMCIA with SH KOAX-PCMCIA PCMCIA Win2000/XP W2K_RAW_DRIVER_V0518.zip..\ARCNET\Win2000 Driver Farc.sys Farc.sys Farc.sys The current card drivers can be downloaded from the SoHard website. The driver versions listed in the "Driver file" column were tested. 3.2 Installation of ARCNET cards under Win2000 / XP 3.2.1 SH ARC PCI - ARCNET card for PCI bus under Win2000 / XP Driver files: Internet: W2K_RAW_DRIVER_V05xx.zip CD V5.x:..\CD_Menu\Files_V5x\ARCNET\Win2000\farc.sys (sharcraw.inf) packed: W2K_RAW_DRIVER_V0517.zip Driver after installation:..\winnt\system32\drivers\farcpci.sys Installing the card: Proceed as follows to install the ARCNET card: 1. Delete the possibly existing old ARCNET driver (V4.xx). To do so, delete the following path in the registry: HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\farc (or farc66) 2. Reboot the PC afterwards. 3. Copy the driver without any subdirectory to a floppy disk. 4. Shut down the operating system of the PC and then switch the computer off. 5. Install the ARCNET card to a PCI slot. 6. Reboot the PC. The card is automatically detected since it supports PnP. The message "Found new Hardware / Network controller -> Please wait" is displayed. The "Hardware Wizard" is executed. This may take some time. 7. After the "Found..." message is displayed, click on "Have Disk" and select: "A:\sharcraw.inf" and "Next". The driver is going to be installed. 8. Reboot the PC. V3 AC500 Installation Control Builder 9 PS501 AC500 / Issued: 08.2005

9. Select "Start => Settings => Control Panel => System => Hardware => Device Manager" and then "SoHard ARCNET / SH ARC PCI (RAW)". 10. In the "Properties", change the DriverAccessName from FARCPCI to FARC. 11. Reboot the PC. Uninstalling the card: Proceed as follows to remove the ARCNET card: 1. Select "Start => Settings => Control Panel => System => Hardware => Device Manager". 2. Select "SoHard ARCNET / SH ARC PCI (RAW)". 3. Select "Delete". 4. Shut down the operating system of the PC and then switch the computer off. 5. Remove the card and restart your PC. Tips and tricks: The following notes will help you, if the communication does not work properly after the installation. 1. The card SH ARC PCI requires PCI version V2.10 and hardware level V1.1. 2. Test program for the drivers: The program arcread.exe is supplied together with the drivers. Start it from a DOS shell using the following command: arcread farc 254<ENTER> The driver will either be started or a corresponding error message will be displayed! 3. LED indication: If the driver is activated correctly and no ARCNET cable is connected, both LEDs should flash (on/off time approx. 1 s). If only the green LED flashes, the interrupt has failed! 4. If necessary, use another PCI slot. 3.2.2 SH ARC PCMCIA - ARCNET-PCMCIA card under Win2000 / XP Driver files: Internet: W2K_RAW_DRIVER_V05xx.zip CD V5.x:..\CD_Menu\Files_V5x\ARCNET\Win2000\farc.sys (sharcraw.inf) packed: W2K_RAW_DRIVER_V0517.zip Driver after installation:..\winnt\system32\drivers\farcpcmcia.sys Installing the card: Proceed as follows to install the ARCNET card: 1. Delete the possibly existing old ARCNET driver (V4.xx). To do so, delete the following path in the registry: HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\farc (or farc66) After this, reboot the PC. 2. Copy the driver without any subdirectory to a floppy disk. 3. Shut down the operating system of the PC and then switch the computer off. 4. Install the ARCNET card to a PCMCIA slot. V3 AC500 Installation Control Builder 10 PS501 AC500 / Issued: 08.2005

5. Reboot the PC. The card is automatically detected since it supports PnP. The message "Found new Hardware / Network controller -> Please wait" is displayed. The "Hardware Wizard" is executed. This may take some time. 6. After the "Found..." message is displayed, click on "Have Disk" and select: "A:\sharcraw.inf" and "Next". The driver is going to be installed. 7. Reboot the PC. 8. Select "Start => Settings => Control Panel => System => Hardware => Device Manager" and then "SoHard ARCNET / SH ARC PCMCIA (RAW)". 9. In the "Properties" change the DriverAccessName from FARCPCMCIA to FARC. 10. Reboot the PC. Uninstalling the card: Proceed as follows to remove the ARCNET card: 1. Select "Start => Settings => Control Panel => System => Hardware => Device Manager". 2. Select "SoHard ARCNET / SH ARC PCMCIA (RAW)". 3. Select "Delete". 4. Shut down the operating system of the PC and then switch the computer off. 5. Remove the card and restart your PC. Tips and tricks: The following notes will help you, if the communication does not work properly after the installation. 1. Verify that the IRQ and/or the I/O range are not assigned twice. To do so, select "Start => Settings => Control Panel => Network => Network Adapter => Resources". 2. Test program for the drivers: The program arcread.exe is supplied together with the drivers. Start it from a DOS shell using the following command: arcread farc 254<ENTER> The driver will either be started or a corresponding error message will be displayed! 3. If the error message..59 (E_FARC_NO_NEXTID) is displayed, the selected interrupt has failed. In this case you should change between master PIC (IRQ 0-7) and slave PIC (IRQ 8-15). IRQ 5 or IRQ 7 should work in almost every case. 4. LED indication: If the driver is activated correctly and no ARCNET cable is connected, both LEDs should flash (on/off time approx. 1 s). If only the green LED flashes, the interrupt has failed! 3.2.3 SH FARC E3 [K] - ARCNET card for ISA bus under Win2000 / XP Driver files: Internet: W2K_RAW_DRIVER_V05xx.zip CD V5.x:..\CD_Menu\Files_V5x\ARCNET\Win2000\farc.sys packed: W2K_RAW_DRIVER_V0517.zip Driver after installation:..\winnt\system32\drivers\farc0.sys V3 AC500 Installation Control Builder 11 PS501 AC500 / Issued: 08.2005

Installing the card: Proceed as follows to install the ARCNET card: 1. Delete the possibly existing old ARCNET driver (V4.xx). To do so, delete the following path in the registry: HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\farc (or farc66) After this, reboot the PC. 2. Determine a free IRQ and I/O range (16 bytes), e.g. by selecting "Start => Programs => Accessories => System Tools => System Information => Hardware Resources". 3. Shut down the operating system of the PC and then switch the computer off. 4. On the card, set the I/O range and the interrupt IRQ according to the enclosed documentation. Note: The following settings are set ex works: I/O-Address = 120 hex IRQ = 10 KOAX mode 2.5 MHz 5. Install the ARCNET card to an ISA slot. 6. Reboot the PC. 7. Copy the driver without any subdirectory to a floppy disk. 8. Select "Start => Settings => Control Panel => System => Hardware => Hardware Wizard => OK". 9. Select "Choose a Hardware device" and "Add new device" and then confirm with "Next". 10. A new hardware component is searched. This may take some time. Since the card does not support PnP, the message "Does not find any new devices on your computer" is displayed. 11. Select "Other devices" and click on "Have disk". 12. Insert the floppy disk and confirm with "OK". The message "Install from disk" is displayed. 13. Select "A:\tsharcraw.inf" and confirm with "OK". The driver is going to be installed. 14. Enter the following card properties: Controller: COM20022 DriverAccess: FARC (is entered automatically) IRQ: Free IRQ determined in step 2 I/O Address: Free I/O range determined in step 2 15. Confirm with "Ready" and "Close" and answer the message dialog with "Yes" to resart the PC. Uninstalling the card: Proceed as follows to remove the ARCNET card: 1. Select "Start => Settings => Control Panel => System => Hardware => Device Manager". 2. Select "SoHard ARCNET / SH FARCxx (RAW)". 3. Select "Delete". 4. Shut down the operating system of the PC and then switch the computer off. 5. Remove the card and restart your PC. V3 AC500 Installation Control Builder 12 PS501 AC500 / Issued: 08.2005

Tips and tricks: The following notes will help you, if the communication does not work properly after the installation. 1. Verify that the IRQ and/or the I/O range are not assigned twice. To do so, select "Start => Settings => Control Panel => System => Hardware => Device Manager => SoHard ARCNET => SH FARCxx". 2. The interrupt must be enabled for ISA in the BIOS. 3. Test program for the drivers: The program arcread.exe is supplied together with the drivers. Start it from a DOS shell using the following command: arcread farc 254<ENTER> The driver will either be started or a corresponding error message will be displayed! 4. If the error message..59 (E_FARC_NO_NEXTID) is displayed, the selected interrupt has failed. In this case you should change between master PIC (IRQ 0-7) and slave PIC (IRQ 8-15). IRQ 5 or IRQ 7 should work in almost every case. 5. LED indication: If the driver is activated correctly and no ARCNET cable is connected, both LEDs should flash (on/off time approx. 1 s). If only the green LED flashes, the interrupt has failed! V3 AC500 Installation Control Builder 13 PS501 AC500 / Issued: 08.2005

Index C I N Contents of the CD of the Control Builder PS501 V1.x 2 Installation of the ARCNET cards 9 Notes regarding the settings of the serial PC interface 7 V3 AC500 Installation Control Builder 14 PS501 AC500 / Issued: 08.2005

Manual No.: 2CDC 125 018 M0201 ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Postfach 10 16 80 69006 Heidelberg, Germany Telephone (06221) 701-0 Telefax (06221) 701-240 Internet http://www.abb.de/stotz-kontakt E-Mail desst.helpline@de.abb.com