AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT



Similar documents
How To Analyze Pesticide Levels In Lemon Oil

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

AppNote 10/2012. Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages KEYWORDS

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

AppNote 2/2012. Determining Phenolic Compounds in Whisky using Direct Large Volume Injection and Stir Bar Sorptive Extraction KEYWORDS ABSTRACT

Expectations for GC-MS Lab

AppNote 7/2009. Analysis of Drugs of Abuse using Automated Disposable Pipette Extraction and LC/MS/MS KEYWORDS ABSTRACT

RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH

Thermal Desorption Unit TDU

AppNote 6/2011. Determination of Pain Management Drugs using Automated Disposable Pipette Extraction and LC-MS/MS KEYWORDS ABSTRACT

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

AppNote 4/2014. Prep-and-Shoot : The Completely Automated Workfl ow for the Hydrolysis and Analysis of Urine Samples by LC/MS/MS.

AppNote 1/2008. Automated Disposable Pipette Extraction of Pesticides from Fruits and Vegetables KEYWORDS ABSTRACT

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Alignment and Preprocessing for Data Analysis

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Determination of N-cyclohexyl-diazeniumdioxide (HDO) containing compounds in treated wood using GC-MS

Analysis of Liquid Samples on the Agilent GC-MS

Pesticide Analysis by Mass Spectrometry

MarkerView Software for Metabolomic and Biomarker Profiling Analysis

Background Information

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

SCION SQ Series GC-MS

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Setting up a Quantitative Analysis MS ChemStation

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Building Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

Analysis of Phthalate Esters in Children's Toys Using GC-MS

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

MassHunter for Agilent GC/MS & GC/MS/MS

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

A Streamlined Workflow for Untargeted Metabolomics

Noise reduction of fast, repetitive GC/MS measurements using principal component analysis (PCA)

Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012.

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Signal, Noise, and Detection Limits in Mass Spectrometry

WHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS. HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE

Aromatic plants: from extraction to analysis

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

FORENSIC TOXICOLOGY LABORATORY OFFICE OF CHIEF MEDICAL EXAMINER CITY OF NEW YORK. VOLATILES ANALYSIS by GCMS HEADSPACE ANALYSIS

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Chemical Analysis of Chardonnay Wines: Identification and Analysis of Important Aroma Compounds

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies

Agilent 7697A Headspace Sampler Data Sheet

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Analyzing Small Molecules by EI and GC-MS. July 2014

How To Test For Contamination In Large Volume Water

A Study on the Variability of Fresh Diesel from Service Station in Kota Bharu Using GC-MS and PCA

Weight Loss Determined from Mass Spectrometry Trend Data in a Thermogravimetric/Mass Spectrometer System

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

[ Care and Use Manual ]

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Turning HTE Agilent LC/MS Data to Knowledge in 1hr

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Thermo Scientific ConFlo IV Universal Interface

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Integrated Data Mining Strategy for Effective Metabolomic Data Analysis

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Chemical analysis service, Turner s Green Technology Group

Chemical Profiling and Differential Analysis of Whiskies Using Orbitrap GC-MS

Fast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

MassLynx 4.1 Getting Started Guide

Multivariate Chemometric and Statistic Software Role in Process Analytical Technology

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Multifunctional Autosampler AOC-6000 C146-E272A

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Quick Start Guide Chromeleon 7.2

AMD Analysis & Technology AG

GC-xt. The most flexible GC /GC-MS liquid sample injector

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M

Authenticity Assessment of Fruit Juices using LC-MS/MS and Metabolomic Data Processing

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Waters Core Chromatography Training (2 Days)

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Thermo Scientific SIEVE Software for Differential Expression Analysis

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Transcription:

AppNote 6/2003 Analysis of Flavors using a Mass Spectral Based Chemical Sensor Vanessa R. Kinton Gerstel, Inc., 701 Digital Drive, Suite J, Linthicum, MD 21090, USA Kevin L. Goodner USDA, Citrus & Subtropical Products Lab, 600 Ave S, NW Winter Haven, FL 3388, USA KEYWORDS Flavors, chemsensor, chemometrics, principal component analysis ABSTRACT Development of flavor formulations can be a challenging task. Individual components of different flavor formulations can be varied in composition and quantity depending on the final product desired. For example, if a new formula needs to be developed that matches a certain target a series of trial formulations can be developed and a method that compares samples is needed. A technique widely used in flavor analysis is gas chromatography coupled with mass spectrometry (GC/MS). The output, a total ion chromatogram (TIC), can be challenging to compare between many samples. This technique can also be time consuming with sample analysis between 30-60 min/ sample. In order to simplify the comparison and decrease analysis times, a mass spectrometry based chemical sensor was investigated. The chemical sensor consists of an x, y, z robot autosampler that is capable of sampling headspace, solid phase

microextraction (SPME) or liquids. The autosampler is directly coupled to a mass spectrometer without a GC which results in MS analysis times of 1-3 min/ sample. Multivariate data analysis is then applied to the samples mass spectral fingerprint and comparison of samples profiles can be easily done with exploratory data analysis. Different flavor formulations were easily compared against each other by visual inspection of their fingerprint projections into a three-dimensional principal component space. These results were validated by running the same samples with a GC/MS instrument. The GC/MS data was also analyzed in the same manner as the MS-only data and compared. Overall, the fast and easy to interpret output of the chemical sensor was found to be an advantage over the traditional GC/MS analysis. EXPERIMENTAL Eight different lime and lemon flavor formulations were provided by a customer. Six replicas of each flavor were analyzed using 7.5 ul aliquots. The aliquots were placed in 10 ml vials which were crimped and equilibrated for 15 minutes at 60 C before static headspace sampling. Since the GERSTEL ChemSensor does not use a column for a separation prior to the mass selective detector (MSD), the entire headspace of each sample is introduced into the MSD. The mass spectrum of each of the eight flavor samples was acquired in 1.20 minute runs in the scan mode using the GERSTEL ChemSensor (Figure 1 GERSTEL ChemSensor, Gerstel). The carbon dioxide peak (from the air in the sample) and the ethanol peaks were avoided by scanning from 48 m/z to 160 m/z range. INTRODUCTION Nowadays new flavors appear in a great variety of food products. For example, coffee, teas, yogurts, etc can be purchased in many different flavors. The chemical analysis of these new and exotic flavors can be demanding. A traditional approach widely used in the flavor industry is the use of Gas Chromatography/Mass spectrometry (GC/MS). Although, GC/MS is a reliable technique, the analysis times can be long (30-60 minutes) and its output (a total ion chromatogram, TIC) can be difficult to compare when many samples are analyzed. In order to simplify the comparison and decrease analysis times, a mass spectrometry based chemical sensor was used in this study. Mass fingerprints were used for comparison instead of the traditional TICs. The chemical sensor used in the static headspace mode provides high sample throughput. The autosampler is directly coupled to a mass spectrometer without a GC which results in MS analysis times of 1-3 min/ sample. Multivariate data analysis is then applied to the samples mass spectral fingerprints and comparison of samples profiles can be easily done with exploratory data analysis such as principal component analysis (PCA). The same data analysis that is applied to the Chem- Sensor data can also be used to examine traditional GC/MS data. This is accomplished by using special macros (ChemSensor macros, Gerstel) that create the samples fingerprints by adding all the scans present in the TIC. The resulting two-dimensional data set can be analyzed with multivariate software. Figure 1. GERSTEL Headspace ChemSensor. All the eight flavor samples were also analyzed using a GC (6890, Agilent Technologies) coupled to a MSD (5973, Agilent Technologies). This instrument was equipped with a Thermal Desorption autosampler (TDS A, Gerstel). The samples were diluted 10,000 fold and extracted for one hour with stir bar sorptive extraction; SBSE (Twister, Gerstel). The two data matrices, one for the static HS and another one for SBSE, were created using ChemStation DA with Gerstel macros. For multivariate data analysis Pirouette 3.11 and InStep 2.11 were used. Both data AN/2003/06-2

sets were mean-centered and normalized before creating the PCA and SIMCA models RESULTS AND DISCUSSION Static Headspace analysis. The entire headspace volatiles of each of the 8 flavor samples were sampled and a characteristic fingerprint mass spectrum was obtained. For example, Figures 2 and 3 represent the TIC and MS obtained for formulations #1 and #8 respectively. From these two figures it can be seen that each flavor sample has a characteristic mass spectrum. Similar results were observed with the mass spectrum from the rest of the flavors formulations. 93 7000000 6000000 160000 120000 68 5000000 80000 79 4000000 40000 53 107 121 136 3000000 m/z--> 60 80 100 120 140 160 2000000 1000000 Time--> 0.20 0.40 0.60 0.80 1.00 Figure 2. TIC and MS of flavor formula #1 obtained with GERSTEL Headspace ChemSensor. 180000 93 160000 140000 160000 120000 59 73 79 67 121 136 120000 80000 55 105 100000 40000 80000 m/z--> 60 80 100 120 140 160 60000 40000 20000 Time--> 0.20 0.40 0.60 0.80 1.00 Figure 3. TIC and MS of flavor formula #8 obtained with GERSTEL Headspace ChemSensor. AN/2003/06-3

Figure 4 contains the mass spectra line plot of all 8 formulations used for developing the chemometric models. A closer look of the profile is seen in the inset that shows how the different flavor samples have different ion abundance and therefore different mass spectral fingerprints. These results also indicate excellent sample reproducibility since each band represents 6 replicas for each sample. 60 20 40 Response 10 Response 0 67 82 m/z 87 20 0 67 87 m/z 107 127 147 Figure 4. Normalized MS data for the eight different flavor samples. Exploratory data analysis was carried out with principal component analysis (PCA). Exploratory analysis indicates if the data is appropriate for building a classification model. PCA searches for correlations among all m/z abundances simultaneously and extracts linear combinations of highly correlated m/z abundances (principal components, or PCs) that describe the greatest amount of sample variability. In this particular data set, 95 % of the variance was captured within the first three PCs. A PCA scores plot is shown in Figure 5, in this plot close distance between points indicates close similarities in the samples mass spectra. For example, formulas #1, #4, #3 and #6 cluster close together which suggests similar chemical composition. On the other hand, samples far away from others such as formula #2 indicate very unique composition. A close examination of the mass spectrum of this sample (light green trace, Figure 4) indicates differences in ion abundances compared to the other samples. Inspection of Figure 5 also indicates very little differences between formulas #1 and #4. AN/2003/06-4

Factor1 Factor2 #7 #5 #8 Factor3 #6 #2 #3 #1 & #4 Figure 5. Projection of flavor samples into the space of the first three principal components with data acquired using the GERSTEL Headspace ChemSensor. One chemometric model was created with the above data. Soft-independent-modeling-class-analogy (SIM- CA) uses PCA to model the shape and position of the samples. An acceptance region is then created for each different type of class. SIMCA models also provide interclass distances between samples, these distances are reported in Table 1. The larger the interclass distance between two groups, the better separated the groups. As a rule of thumb, interclass distance of 3 or greater indicates good separation between the samples. Interclass distance of less than 3 indicates small differences between the samples. For this analysis, it can be seen that the smallest interclass distance is between flavors #1 and #4 with a value of only 6.4. Table 1. Interclass distances. #1 #3 #4 #6 #1 0.0 24.6 6.4 7.2 #3 24.6 0.0 34.2 24.3 #4 6.4 34.2 0.0 11.3 #6 7.2 24.3 11.3 0.0 AN/2003/06-5

Twister analysis. All the eight flavors were also analyzed using Twister extraction. The resulting chromatograms for the eight samples indicated some differences between them. A PCA scores plot for the GC/MS flavors is shown in Figure 6. It can be seen in this figure that the clustering is similar to the one obtained with static HS. For example, formulas #1 and #4 cluster very tight, which can also be seen in Figure 5. Figure 7 contains a TIC overlay of formulas #1 and #4, both in replicas. It can be seen from Figure 7 that the chromatograms for formulas #1 and #4 match very closely. These results are in agreement with the results obtained with the GERSTEL ChemSensor. #5 Factor1 #7 #2 #8 Factor3 #3 Factor2 #6 #1 & #4 Figure 6. Projection of flavor samples into the space of the first three principal components with data acquired using Twister extraction and GC/MS. AN/2003/06-6

2.5e+07 2e+07 1.5e+07 1e+07 5000000 Time--> 6.00 8.00 10.00 12.00 1000000 750000 500000 250000 Time--> 11.80 12.00 12.20 12.40 12.60 12.80 13.00 Figure 7. Overlay chromatograms of flavor #1 and flavor #4 acquired using Twister extraction and GC/MS. The biggest advantage of using the GERSTEL Chem- Sensor instead of the Twister GC/MS analysis lies in the time savings. For example, the analysis of 50 samples required 4 hours using the Chemsensor, while a single Twister GC/MS run was 30 minutes. CONCLUSIONS Differences between 8 different formulations were detected using a mass spectral based chemical sensor with static headspace introduction. Results were validated using traditional GC/MS with SBSE-Thermal Desorption introduction. Advantages of using the chemical sensor include fast sample throughput and easy to interpret results. For this particular application, flavor formula #1 was found to be very similar to flavor formula #4. This result was also confirmed by the flavor supplier. AN/2003/06-7

GERSTEL GmbH & Co. KG Eberhard-Gerstel-Platz 1 45473 Mülheim an der Ruhr Germany +49 (0) 208-7 65 03-0 +49 (0) 208-7 65 03 33 gerstel@gerstel.com www.gerstel.com GERSTEL Worldwide GERSTEL, Inc. 701 Digital Drive, Suite J Linthicum, MD 21090 USA +1 (410) 247 5885 +1 (410) 247 5887 sales@gerstelus.com www.gerstelus.com GERSTEL AG Wassergrabe 27 CH-6210 Sursee Switzerland +41 (41) 9 21 97 23 +41 (41) 9 21 97 25 swiss@ch.gerstel.com www.gerstel.ch GERSTEL K.K. 1-3-1 Nakane, Meguro-ku Tokyo 152-0031 SMBC Toritsudai Ekimae Bldg 4F Japan +81 3 5731 5321 +81 3 5731 5322 info@gerstel.co.jp www.gerstel.co.jp GERSTEL LLP Level 25, North Tower One Raffles Quay Singapore 048583 +65 6622 5486 +65 6622 5999 SEA@gerstel.com www.gerstel.com Information, descriptions and specifications in this Publication are subject to change without notice. GERSTEL, GRAPHPACK and TWISTER are registered trademarks of GERSTEL GmbH & Co. KG. GERSTEL Brasil Av. Pascoal da Rocha Falcão, 367 04785-000 São Paulo - SP Brasil +55 (11)5665-8931 +55 (11)5666-9084 gerstel-brasil@gerstel.com www.gerstel.com.br CERTIFIED QM-SYSTEM ISO 9001 IS O C E RTIFIC AT E 9 0 0 1:2 0 0 8 N O. D 0086 Copyright by GERSTEL GmbH & Co. KG Awarded for the active pursuit of environmental sustainability