SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data



Similar documents
SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

ProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Biopharmaceutical Glycosylation Analysis

Aiping Lu. Key Laboratory of System Biology Chinese Academic Society

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Introduction to Proteomics 1.0

Mass Spectrometry Based Proteomics

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

MarkerView Software for Metabolomic and Biomarker Profiling Analysis

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Mass Frontier 7.0 Quick Start Guide

Proteomics in Practice

Application Note # LCMS-66 Straightforward N-glycopeptide analysis combining fast ion trap data acquisition with new ProteinScape functionalities

ProteinPilot Report for ProteinPilot Software

Error Tolerant Searching of Uninterpreted MS/MS Data

Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests

Tutorial for Proteomics Data Submission. Katalin F. Medzihradszky Robert J. Chalkley UCSF

ProSightPC 3.0 Quick Start Guide

Mass Frontier Version 7.0

Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012.

MS/MS analysis of Polyphenols

Research-grade Targeted Proteomics Assay Development: PRMs for PTM Studies with Skyline or, How I learned to ditch the triple quad and love the QE

Choices, choices, choices... Which sequence database? Which modifications? What mass tolerance?

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics

NUVISAN Pharma Services

Laboration 1. Identifiering av proteiner med Mass Spektrometri. Klinisk Kemisk Diagnostik

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Challenges in Computational Analysis of Mass Spectrometry Data for Proteomics

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Electrospray Ion Trap Mass Spectrometry. Introduction

A Streamlined Workflow for Untargeted Metabolomics

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Waters Core Chromatography Training (2 Days)

MASCOT Search Results Interpretation

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

MassHunter for Agilent GC/MS & GC/MS/MS

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Analyst 1.6 Software. Software Reference Guide

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

La Protéomique : Etat de l art et perspectives

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

L. Yu et al. Correspondence to: Q. Zhang

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Global and Discovery Proteomics Lecture Agenda

TECHNICAL BULLETIN. ProteoMass Peptide & Protein MALDI-MS Calibration Kit. Catalog Number MSCAL1 Store at Room Temperature

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Analyst Software

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Background Information

Electrospray Mass Spectrometry of Tris-acetylacetonatochromium(III)

Application Note # MT-90 MALDI-TDS: A Coherent MALDI Top-Down-Sequencing Approach Applied to the ABRF-Protein Research Group Study 2008

NIST Standard Reference Database 1A

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis

Correlation of the Mass Spectrometric Analysis of Heat-Treated Glutaraldehyde Preparations to Their 235nm / 280 nm UV Absorbance Ratio

Metabolomics Software Tools. Xiuxia Du, Paul Benton, Stephen Barnes

flexanalysis User Manual

Pesticide Analysis by Mass Spectrometry

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

Master course KEMM03 Principles of Mass Spectrometric Protein Characterization. Exam

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

WATERS QUANTITATIVE ANALYSIS solutions

Standard Mixture. TOF/TOF Calibration Mixture. Calibration Mixture 1 (Cal Mix 1, 1:10) Calibration Mixture 1 (Cal Mix 1, 1:100)

Pep-Miner: A Novel Technology for Mass Spectrometry-Based Proteomics

Application Note # MT-103 FAST-SRM: A new Single Reaction Monitoring Method for Fast, Targeted Drug Distribution Testing in Tissue Sections

LC-MS/MS for Chromatographers

13C NMR Spectroscopy

Contents. Preface to the Second Edition List of Contributors XIII

Mass Spectrometry. Overview

Authenticity Assessment of Fruit Juices using LC-MS/MS and Metabolomic Data Processing

What Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model?

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Session 1. Course Presentation: Mass spectrometry-based proteomics for molecular and cellular biologists

Agilent G2721AA/G2733AA Spectrum Mill MS Proteomics Workbench

MALDI-MS Product overview 1 Company Instrument Benchtop (j/n)

Mass Spectrometry Signal Calibration for Protein Quantitation

Investigating Biological Variation of Liver Enzymes in Human Hepatocytes

1 Genzyme Corp., Framingham, MA, 2 Positive Probability Ltd, Isleham, U.K.

Xcalibur Versions

Transcription:

SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data Automated Data Interpretation for Glycan Characterization Jenny Albanese 1, Matthias Glueckmann 2 and Christof Lenz 2 1 AB SCIEX, USA and 2 AB SCIEX, Germany The analysis of carbohydrates is of great importance in modern biochemistry and is often tackled using various analytical techniques, including mass spectrometry. However, the structural analysis of carbohydrates by mass spectrometry is not routine and often requires tedious, time consuming manual spectral interpretation. Additionally, the analysis requires the knowledge of various carbohydrate sequences, anomeric linkages between the monosaccharides and their fragmentation patterns under different experimental conditions such as permethylation, reducing end modifications, adducts used, and the ionization mode. Here, we present novel software for the characterization of carbohydrates. SimGlycan Software predicts the structure of a glycan from the MS/MS data acquired by mass spectrometry, facilitating the study of glycosylation and post translational modifications. It supports MS/MS profiles of both glycopeptides and released glycans and can deduce carbohydrate and glycan composition and structure directly from low and high energy CID MS/MS data. SimGlycan accepts experimental MS/MS data generated by all AB Sciex mass spectrometers, including the 4000 QTRAP System, QSTAR Elite System, and the 4800 Plus MALDI TOF/TOF Analyzer. SimGlycan matches these Figure 1. Matching, Scoring and Glycan Ranking. SimGlycan Software verifies the monosaccharide composition of the unknown glycan using diagnostic ions calculated for various glycans in the database. A composition score is calculated for every candidate entry. Further, a branching score is calculated to identify the linkages and branching patterns of the unknown glycan using the internal and cross ring cleavages of theoretical glycans. The glycan with the highest composition and branching scores should reflect the actual structure. experimental MS/MS data with its own database containing theoretical fragmentation of over 8,000 glycans and generates a list of probable glycan structures. Each structure is scored to reflect how closely it matches the experimental data (Figure 1). SimGlycan provides for every probable glycan result, the glycan fragments, structure, sequence, composition, glycan mass, class, reaction, pathway, enzyme and other database links, allowing easy access to all published glycan information without referring to multiple sources. Key Features of SimGlycan Software Imports experimental MS/MS data generated by all AB SCIEX mass spectrometers and can be launched directly from Analyst QS 2.0 and Analyst 1.5 Software using the companion software feature. Matches glycan MS/MS data with its own database of theoretical fragmentation of over 8,000 glycans by using a proprietary ranking and scoring algorithm. Database can be searched using ID, sequence, composition or mass. References other biological information for the probable glycan structures such as glycan class, reaction, pathway and enzyme. Structural analysis of glycopeptides can be performed by specifying the sequence or mass of the attached peptide moiety. Enables searching for glycans with chemical derivatives used for reducing end modifications even if the derivative is not available in the program s database. p 1

Materials and Methods MALDI Sample Preparation: Carbohydrate samples in different concentrations were prepared using DHB matrix (20 mg/ml in deionized water). Dried droplets were prepared with carbohydrate solutions at concentrations of 10-4 to 10-5 mol/l. Mass Spectrometry: Samples were analyzed using the 4800 Plus MALDI TOF/TOF Analyzer in reflector mode. Positive ion MS/MS data of sodiated ions were collected using 2kV collision energy and air or Argon as collision gas. Operating pressure of ion source was 10-7 Torr. For the 4000 QTRAP System, MS/MS and MS 3 experiments were performed using a NanoSpray Source (800 V) and medium nanospray needles (Protana). Samples were sprayed from water:methanol (1:1, v:v). Positive ion spectra were obtained with added sodium acetate. MS/MS spectra were acquired from N-linked glycans at 1000 amu/sec. The MS/MS and MS 3 collision and excitation energies were set to be appropriate for the mass of the compounds. The Q1 resolution was low to allow transmission of the isotopic envelope from each ion and the declustering potential (30 V) was low to prevent insource decay. Figure 2. SimGlycan Software User Interface. The search results window of SimGlycan software provides an intuitive user interface for data review. In the upper pane, search results from a high energy CID MS/MS spectrum are displayed. In the lower pane, the glycan information is listed. The Glycan Structure button provides the sequence and linkage information. An example of a glycopeptide search is shown below that. The Glycan Fragments button provides the sequence, m/z, and theoretical glycosidic and cross ring fragment ions. These can be further searched by name, mass or m/z value. p 2

SimGlycan Settings: SimGlycan accepts experimental m/z and intensity values (MS/MS data) of glycans. The following settings were used for the data: Precursor ion tolerance of 1 Da, precursor ion m/z as indicated on the figures, spectrum peak m/z tolerance of 0.2 Da, no glycan derivatization, ion mode was MALDI positive for the 4800 Plus MALDI TOF/TOF Analyzer and ESI positive for the 4000 QTRAP System, and the adduct was sodiated carbohydrates as [M+Na]+. Intuitive User Interface for Efficient Data Review The interface is organized such that important information is at the user s finger tips (Figure 2). The navigation window on the left makes it easy to move from one MS/MS spectrum to the next within each project. Search results are displayed in two panes: the results display pane and the glycan information pane. The Glycan Structure button displays the glycan structure along with its sequence. If glycopeptide MS/MS data are used for prediction, then clicking the Glycan Structure button shows the molecular structure of the glycan along with the specified peptide sequence/mass, including any modifications. On clicking the Glycan Fragment button, a list of glycan fragments is displayed. Specific fragments can be searched by name, mass or m/z value. Data Processing of Carbohydrates and Glycopeptides with SimGlycan Software In addition to being easy to use, SimGlycan software is extremely flexible for importing and exporting data. SimGlycan accepts MS/MS or MS3 data in text format or Microsoft Excel format containing m/z and intensity. It directly imports data from the 4000 QTRAP System, QSTAR Elite System and the 4800 Plus MALDI TOF/TOF Analyzer. For files containing multiple spectra such as LC/MS/MS experiments, the user decides on the glycan or glycopeptide spectrum of choice in the acquisition software and then selects the data file and specific spectrum within SimGlycan software. SimGlycan then imports a peak list from this particular spectrum. To search and score carbohydrate MS/MS or MS 3 data, simply fill in all the required parameters, precursor ion m/z, precursor ion m/z error tolerance, and spectrum peak m/z error tolerance. Other key settings included Glycan Derivatization, Reducing Terminal, Ion mode, and Adduct. For glycopeptide interpretation, the workflow is similar except the Reducing Terminal field is not applicable and additional parameters are employed such as peptide mass, sequence, and peptide modification (Figure 3). The results are viewed in the Search Result tab. Selecting the MS/MS Annotation tab will display matched m/z values in blue and unmatched m/z values in yellow. The Plot Mass Spectrum button creates an MS/MS spectrum of all matched and unmatched fragment ions (Figure 4). A comprehensive glycan search report can be generated for lab notebooks, publication, or sharing information with colleagues. The report includes the glycan characteristics such as the identification, sequence, name, composition, mass, precursor ion m/z, class, reaction, and pathway, along with a graphical view of the glycan and its possible theoretical fragments (Figure 5). SimGlycan can save search results at any desired location by selecting the Export Results option. The results are exported to any supported file format for printing or further processing. Figure 3. Carbohydate and Glycopeptide Search Parameters. The Search and Score window displays the required parameters for a carbohydrate search. An example of data input for a MALDI MS/MS spectrum containing sodium adducts is shown. In the case of a glycopeptide search, additional peptide information is required. p 3

Figure 4. Search Results and MS/MS Annotation of m/z 1485.8 Precursor Generated by the 4800 Plus MALDI TOF/TOF Analyzer. Dragging the mouse over each annotated peak displays the fragment ion label using the nomenclature of Domon and Costello 1. Figure 5. Generate Report and Report View. The Generate Report window provides a variety of display and reporting options. p 4

4800 Plus MALDI TOF/TOF Analyzer for Carbohydrate Analysis Because of its large mass range, high sensitivity, and soft desorption and ionization, MALDI time of-flight (MALDI-TOF) mass spectrometry is widely used in the molecular weight determination of underivatized oligo- and polysaccharides 2,3. Since the introduction of the post-source decay (PSD) technique for MALDI TOF mass spectrometers, several studies concerning the PSD analysis of oligosaccharides have shown that much information can be obtained by MALDI-PSD-TOF experiments 4,5. PSD (metastable or unimolecular decay) spectra of sodiated ions from neutral carbohydrates are dominated by glycosidic and internal cleavages, providing information related to sequence and branching; however, a lack of abundant cross-ring cleavages limits the linkage information that can be deduced from such experiments. Cross-ring fragmentation can be induced by high energy collision-induced dissociation (CID) on MALDI TOF/TOF instruments 6,7. Figure 6 shows a comparison at different instrument conditions (Collision induced dissociation (CID) vs. metastable decay) and their SimGlycan results for each MS/MS spectrum of Maltoheptaose [M+Na] +, m/z 1175.3. As shown in Figure 6, higher energy CID provides cross-ring fragmentation and allows the assignment of the correct linkage, whereas PSD alone incorrectly identifies the glycan as a branched carbohydrate. Figure 6. Comparison of Different Fragmentation Techniques. The top pane shows PSD fragmentation and the middle and bottom panes show true high energy CID using different collision gases. As shown, the CID spectra generate important cross ring fragments that allow full characterization of the saccharide sequence and linkage. p 5

4000 QTRAP System for Carbohydrate Analysis QTRAP systems are hybrid triple quadrupole linear ion trap mass spectrometers and are unique in their ability to perform post translational modification (PTM) discovery experiments. Coupling the triple quadrupole scan functions (precursor ion scan, multiple reaction monitoring- MRM) with the high sensitivity ion trap MS/MS and MS 3 scans enables sensitive and selective experiments to be performed on glycan structure and connectivity. Figure 7 shows MS/MS and MS 3 data for a Neutral N-glycan. The major singly and doubly charged ions in the presence of sodium acetate were [M + Na] +. The SimGlycan Software search results of the fragment data obtained from both the MS/MS and MS3 spectra lead to the correct glycan identification. An MS 3 spectrum helped to confirm the glycan ID (Figures 7, 8). Figure 7. Glycan Spectra Generated by the 4000 QTRAP System. (Top) Glycan MS/MS m/z 1663.5+. (Bottom) Glycan MS 3 m/z 1663.5+ > 1036.4+. Fragment ions produced in the MS 3 spectrum helped to confirm the glycan sequence identification. QSTAR Elite System for Carbohydrate Analysis Figure 8: Search Results for 4000 QTRAP System Neutral N-Glycan Data. The top search result is the correct identification. Shown in the inset is the glycan structure for the top result. MS 3 data helped to confirm the identity of the glycan. QSTAR Systems (hybrid quadrupole TOF instruments) equipped with a NanoSpray Source can be successfully employed for glycan analysis, performing MS/MS experiments in positive ion mode and delivering additional structural information in negative ion mode8. Additionally, the omaldi 2 Source allows rapid MS detection of the intact mass and fast compositional analysis of the glycans by MS/MS. The combination of exoglycosidase digests with a QSTAR system allows complete glycan structure analysis in a relatively short period (hours) with small amounts of material (picomoles)9. Exoglycosidases produce highly specific glycosidic bond cleavages that are sensitive to the linkage, the stereochemistry, and even the configuration of the anomeric carbon. This workflow involves digestion of the oligosaccharide with defined exoglycosidases, followed by analysis of the digestion products. The sequence of the oligosaccharide and the specific linkages between the individual sugar moieties are deduced from the pattern of observed carbohydrate fragments and the specificity of the enzymes. SimGlycan Software can predict possible glycans IDs, which can be further confirmed by the MS profiles of sequential exoglycosidase digests. p 6

Conclusions SimGlycan Software is a powerful program for the analysis of carbohydrates in general and glycans in particular. For every probable glycan structure, SimGlycan provides glycan fragments, structure, sequence, composition, glycan mass, class, reaction, pathway, enzyme and other database links. All the possible glycan structures are ranked based on SimGlycan's proprietary search and scoring algorithm. In high energy MALDI CID MS/MS spectra generated by the 4800 Plus MALDI TOF/TOF Analyzer, a considerably greater number of fragments are found for the fragmentation of carbohydrates in comparison to other mass spectrometry fragmentation techniques. Although this could complicate any type of manual interpretation, it permits acquisition of more information on linkage position and points of branching, allowing the automated search routine in SimGlycan Software to correctly identify and characterize glycans. In contrast, the QSTAR Elite and 4000 QTRAP Systems generate low energy CID spectra. For the 4000 QTRAP System, a comparison was performed between collision cell MS/MS and ion trap MS/MS mode and the fragment ions observed were found to be very similar. The major fragments were B- and Y- type glycosidic cleavages with small amounts of cross-ring fragments defining linkage. Because of the unique instrument configuration in the QTRAP system, the MS/MS spectra do not show the low mass cut-off experienced by 3D-ion traps. Subsequent MS3 fragmentation spectra were obtained with good signal/noise allowing mechanistic studies to be performed on the diagnostic fragments to confirm a predictive SimGlycan search result. In addition, the use of negative ions generated by either a QSTAR or QTRAP system give very specific fragmentation and details of the fine structure of the glycans (data are not shown). References 1. Domon, Costello. Glycoconj. J. 5 (1988) 397-409. 2. Karas, Bachmann, Bahr, Hillenkamp. Int. J. Mass Spectrom. Ion Processes 1988; 78: 53. 3. Garozzo, Spina, Sturiale, Montaudo, Rizzo. Rapid Commun. Mass Spectrom. 1994; 8: 358. 4. Spengler, Kirsch, Kauffmann, Lemoine. J. Mass Spectrom. 1995; 30: 782. 5. Kauffmann, Chaurand, Kirsch, Spengler. Rapid Commun. Mass Spectrom. 1996; 10: 1199. 6. Mechref, Novotny, Krishnan. Anal. Chem. 2003, 75: 4895. 7. Spina, Sturiale, Romeo, Impallomeni, Garozzo, Waidelich, Glueckmann, Rapid Commun. Mass Spectrom. 2004, 18, 392-398. 8. Harvey, Thomas-Oates, Thomas, Waidelich, Main, Lenz, Hornshaw. ASMS2004. 9. Colangelo, Orlando. Anal. Chem., 1999, 71, (7), pp 1479 1482. *Founded in 1994, PREMIER Biosoft is a group of computer scientists and molecular biologists dedicated to producing cutting-edge intuitive software for the molecular biologist. The goal of the company is to study the most recent innovations in molecular biology and translate them into software products that aid biologists. Additional information about PREMIER Biosoft International is available at http://www.premierbiosoft.com. For Research Use Only. Not for use in diagnostic procedures. 2010 AB SCIEX. The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners. AB SCIEX is being used under license. Publication number: 1038410-01 p 7