SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Similar documents
SIMATIC. ET 200S distributed I/O 2AI U ST analog electronic module (6ES7134-4FB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O IM151-1 STANDARD interface module (6ES7151-1AA05-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300

Part 1: User information SIMATIC ET 200B Distributed I/O Station Manual Part 2: Reference information Appendices EWA 4NEB c Edition 04

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual

Modular I/O System Analog and Digital Interface Modules

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Fieldbus slave modules with I/Os, DIO

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

SIMATIC HMI. WinCC flexible 2008 Getting Started - First-Time Users Getting Started. Printout of the Online Help 06/2008 A5E

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) SIMATIC. S7-1500/ET 200MP DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) Preface

Validity 1. Installation 2 SIMATIC. WinCC flexible Tag simulator Update 1. Readme

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application

SIMATIC. S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis. Introduction. Preparation. Learning units 3. Further information 4.

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

What ensures easy and fast wiring?

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

SIMATIC NET. Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs. Preface. Overview and general information on working with FCs and FBs

SIMATIC. SIMATIC Logon. User management and electronic signatures. Hardware and Software Requirements. Scope of delivery 3.

L5354 ControlNet Communications Interface

MINI MCR-SL-R-UI(-SP)

SIMATIC. Windows Automation Center WinAC Slot Version 4.0. Preface, Contents. Product Overview 1. Installing the CPU 41x-2 PCI.

SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Contents. Document information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3. Simatic. Readme. Readme


JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Product Datasheet P MHz RF Powerharvester Receiver

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

CQM1-SF200/CS1W-SF200

Creating the project and hardware. TIA Portal. SIMATIC Creating the project and hardware. Introduction to the TIA Portal 1. Creating a project

Inductive Proximity Sensors

SIMATIC. Open TCP/IP Communication via Industrial Ethernet. Contents Open TCP/IP Communication via Industrial Ethernet 1. Index.

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

ZC-24DO CANopen I/O Module: 24 Digital Outputs

NEW. EVEN MORE data acquisition and test stand automation

SIMADYN D Digital Control System. Interface module SE21.2. User Manual. Edition DK-Nr

CompactLogix Power Supplies Specifications

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

Information Server Documentation SIMATIC. Information Server V8.0 Update 1 Information Server Documentation. Introduction 1. Web application basics 2

T7560A,B,C Digital Wall Module

Patch management and security. updates SIMATIC. Process Control System PCS 7 Patch management and security updates. Preface 1

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

DB Administration COMOS. Platform DB Administration. Trademarks 1. Prerequisites. MS SQL Server 2005/ Oracle. Operating Manual 09/2011

IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

PCXpocket 440. Professional Digital Audio Card. User s manual. DU IS=A

SIMATIC. S Getting started with S Preface. Quick review 1. Installation 2. Create a simple latch circuit 3. Complete the user program 4

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection (V12.1) Preface 1. Virus scanner administration 2.

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

SIMATIC. PROFINET IO Getting Started: Collection. CPU PN/DP: Configuring PROFINET interface X2

Digital input modules

Automation Unit TM 1703 ACP Flexible automation and telecontrol

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Current Monitoring Kit

SIMATIC HMI. WinCC flexible Getting Started First Time User. Order number 6ZB5370-1CL02-0BA2. Edition 04/2006 A5E

Performing an automated installation

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

PCS0100en Persy Control Services B.V. Netherlands

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Installation guide H A. HSI hardwired system interface

Configuration limits for products of the SIMATIC NET PC Software V12 SIMATIC NET. Configuration limits for products of the SIMATIC NET PC Software V12

LC898300XA. Functions Automatic adjustment to the individual resonance frequency Automatic brake function Initial drive frequency adjustment function

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

DS Wire Digital Thermometer and Thermostat

Model SPDT Relays

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

SIMOTION. Supplement to the FM 350-1, FM and FM 352 Modules. Preface. Description 1. Function blocks of the FM 350-1

PCAN-ISA. CAN Interface for ISA. User Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

NOT RECOMMENDED FOR NEW DESIGNS

IRT Eurocard. Types DAX-3200

Short information Parameters are programmed via front-side membrane keypad

T0118 T2118 T3118. Instruction Manual

Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

Transcription:

SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation 4 Connecting 5 04/2007 A5E01076949-01

Safety Guidelines Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE Qualified Personnel Prescribed Usage Trademarks indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Note the following Disclaimer of Liability WARNING This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. Siemens AG Automation and Drives Postfach 48 48 90327 NÜRNBERG GERMANY Ordernumber A5E01076949-01 P 09/2007 Copyright Siemens AG 2007. Technical data subject to change

Preface Purpose of the manual This manual supplements the ET 200S Distributed I/O System Operating Instructions. General functions for the ET 200S are described in the ET 200S Distributed I/O System Operating Instructions. The information in this document along with the operating instructions enables you to commission the ET 200S. Basic knowledge requirements To understand these operating instructions you should have general knowledge of automation engineering. Scope of the manual This manual applies to this ET 200S module. It describes the components that are valid at the time of publication. Recycling and disposal Thanks to the fact that it is low in contaminants, this ET 200S module is recyclable. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste. Additional support If you have any questions relating to the products described in these operating instructions, and do not find the answers in this document, please contact your local Siemens representative. http//www.siemens.com/automation/partner The portal to our technical documentation for the various SIMATIC products and systems is available at http//www.siemens.com/automation/simatic/portal The online catalog and ordering system are available at http//www.siemens.com/automation/mall Manual, 04/2007, A5E01076949-01 3

Preface Training center We offer courses to help you get started with the ET 200S and the SIMATIC S7 automation system. Please contact your regional training center or the central training center in D - 90327, Nuremberg, Germany. Phone +49 (911) 895-3200. http//www.siemens.com/sitrain Technical Support You can reach technical support for all A&D projects using the support request web form http//www.siemens.com/automation/support-request Phone + 49 180 5050 222 Fax + 49 180 5050 223 For more information about our technical support, refer to our Web site at http//www.siemens.de/automation/service Service & Support on the Internet In addition to our documentation services, you can also make use of our comprehensive online knowledge base on the Internet. http//www.siemens.com/automation/service&support There you will find Our Newsletter, which constantly provides you with the latest information about your products. The right documentation for you using our Service & Support search engine. The bulletin board, a worldwide knowledge exchange for users and experts. Your local contact for Automation & Drives in our contact database. Information about on-site services, repairs, spare parts. Lots more can be found on our "Services" pages. 4 Manual, 04/2007, A5E01076949-01

Table of contents Preface... 3 1 Properties... 7 1.1...7 2 Parameters... 11 2.1 Parameters...11 3 Diagnostics... 13 3.1 Diagnostics using LED display...13 3.2 Error types...14 4 Analog value representation... 15 4.1 Introduction...15 4.2 Analog value representation for measuring ranges with SIMATIC S7 with 2AO U HF...15 4.3 Output ranges...16 4.4 Effect on analog value representation...17 4.4.1 Effect of the supply voltage and the operating state on analog output values...17 4.4.2 Effect of the value range on the 2AO I ST analog output...18 5 Connecting... 19 5.1 Connecting analog outputs...19 Index... 21 Manual, 04/2007, A5E01076949-01 5

Table of contents 6 Manual, 04/2007, A5E01076949-01

Properties 1 1.1 Properties 2 outputs for current output Output range ± 20 ma, resolution 13 bits + sign 4 to 20 ma, resolution 13 bits Isolated from the load voltage L+ Extended temperature range from 0 to 50 C with vertical installation General terminal assignment Note Terminals 4, 8, A4, A8, A3 and A7 are only available at specified terminal modules. Terminal assignment for 2AO I ST (6ES7135-4GB01-0AB0) Terminal Assignment Terminal Assignment Notes 1 QI0 5 QI1 QIn Current analog output, Channel n 2 n.c. 6 n.c. Mana Ground of the module 3 Mana 7 Mana n.c. Not connected (max. 30 V DC can be connected) 4 n.c. 8 n.c. AUX1 Protective-conductor terminal or potential bus (freely usable up to 230 VAC) A4 AUX1 A8 AUX1 A3 AUX1 A7 AUX1 Manual, 04/2007, A5E01076949-01 7

Properties 1.1 Usable terminal modules TM-E15C26-A1 (6ES7193-4CA50- TM-E15S26-A1 (6ES7193-4CA40- TM-E15N26-A1 (6ES7193-4CA80- Usable terminal modules for 2AO I ST (6ES7135-4GB01-0AB0) TM-E15C24-A1 (6ES7193-4CA30- TM-E15S24-A1 (6ES7193-4CA20- TM-E15N24-A1 (6ES7193-4CA70- TM-E15C24-01 (6ES7193-4CB30- TM-E15S24-01 (6ES7193-4CB20- TM-E15N24-01 (6ES7193-4CB70- TM-E15C23-01 (6ES7193-4CB10- TM-E15S23-01 (6ES7193-4CB00- TM-E15N23-01 (6ES7193-4CB60- Spring terminal Screw-type terminal Fast Connect Block diagram Figure 1-1 Block diagram of the 2AO I ST 8 Manual, 04/2007, A5E01076949-01

Properties 1.1 2AO I ST Technical data (6ES7135-4GB01-0AB0) Dimensions and weight Width (mm) 15 Weight Supports isochronous operation Approx. 40 g Module-specific data Number of outputs 2 Cable length Shielded Max. 200 m Parameter length Address space Rated load voltage L+ (from the power module) No 7 bytes 4 bytes Voltages, currents, potentials Reverse polarity protection Yes Electrical isolation Between the channels and backplane bus Yes Between the channels and load voltage Yes Between the channels No Permissible potential difference Between MANA and the central grounding point (Uiso) Insulation tested Current consumption 24 VDC 75 VDC / 60 VAC 500 VDC From the power supply L+ Max. 150 ma Power dissipation of the module Diagnostics function Max. 2 W Status, interrupts, diagnostics Group error Red "SF" LED Diagnostic functions readable Yes Resolution (including overshoot range) Cycle time Settling time Analog value generation ± 20 ma/13 bits + sign 4 to 20 ma/13 bits Max. 1.5 ms For resistive load 0.1 ms For capacitive load 0.5 ms For inductive load 0.5 ms Substitute values can be applied Yes Manual, 04/2007, A5E01076949-01 9

Properties 1.1 Crosstalk between the outputs Operational limit (in the entire temperature range, with reference to the output range) Basic error limit (operational limit at 25 C with reference to output range) Temperature error (with reference to the output range) Suppression of interference, limits of error Min. -40 db ± 0,5 % ± 0,3 % ± 0.01 %/K Linearity error (with reference to the output range) ± 0,02 % Repeatability ± 0,05 % (in steady state at 25 C with reference to output range) Output ripple (with reference to output range, ± 0,02 % bandwidth 0 to 50 khz) Data for selecting the actuator Output range (rated value) ± 20 ma 4 to 20 ma Load resistance Max. 500 Ω For inductive load 1 mh Open circuit voltage 18 V Destruction limit against voltages/currents applied from outside Voltage at the outputs to MANA Max. 15 V continuous; 75 V for max. 1 ms (sampling ratio 120) Current Max. 50 ma DC Connection of actuators Two-wire connection Yes Four-wire connection No 10 Manual, 04/2007, A5E01076949-01

Parameters 2 2.1 Parameters Table 2-1 Parameters for analog output module 2AO I ST Range of values Default setting Applicability Group diagnostics (parameter Disable assignment error, internal error) Enable Diagnostics Wire break 1 Disable Enable Response to CPU/master No output current or voltage STOP Substitute a value Keep last value Type/range of output Deactivated 4 to 20 ma ± 20 ma Substitute value 2 To 65,535 (value range must lie within the nominal range) 1 No diagnostics detection between -1.1852 ma and +1.1852 ma. Disable Module Disable Channel No output current or voltage Module 4 to 20 ma Channel ± 20 ma 0 ma Channel 4 to 20 ma 4 ma 2 If there is no voltage being supplied to the interface module or COMPACT module but the supply to the analog output modules continues, the substitute values that have been assigned parameters are output. Substitute values must be within the nominal range. You can assign values from -27,648 to +27,648 as parameters (when assigning parameters using the GSD file). Manual, 04/2007, A5E01076949-01 11

Parameters 2.1 Parameters 12 Manual, 04/2007, A5E01076949-01

Diagnostics 3 3.1 Diagnostics using LED display LED display 1 1 Batch error (red) Status and error displays Event (LED) SF On Cause No configuration or incorrect module plugged in. No load voltage.present There is a diagnostic message. Remedy Check the parameter assignment. Check the load voltage. Evaluate the diagnostics. Manual, 04/2007, A5E01076949-01 13

Diagnostics 3.2 Error types 3.2 Error types Analog output module error types Table 3-1 Error types 16D Error type Meaning Remedy 10000 Parameter assignment error Module cannot use the parameter for the channel Inserted module does not match the one configured. Incorrect parameter assignment. 9D 01001 Error Internal module error has occurred (diagnostic message on channel 0 applies to the entire module). 6D 00110 Open circuit Line to the final controlling element interrupted. Correct the configuration (align actual and set configuration). Correct the parameter assignment (wire break diagnostics only parameterized for the permitted measuring ranges). Replace the module. Correct the process wiring. 14 Manual, 04/2007, A5E01076949-01

Analog value representation 4 4.1 Introduction Electronic modules with analog outputs With the electronic modules with analog outputs, digital values set by a controller can be converted to a corresponding analog signal (current) in an analog output module and used to control suitable actuators (setpoint input for speed controllers, temperature controllers and similar). 4.2 Analog value representation for measuring ranges with SIMATIC S7 with 2AO U HF Analog value representation With the same nominal range, the digitized analog value is the same for input and output values. Analog values are represented in two's complement. The following table shows the analog value representation for the analog electronic modules. Table 4-1 Analog value representation (SIMATIC S7 format) Resolution Analog value Bit number 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Significance of the bits S 2 14 2 13 2 12 2 11 2 10 2 9 2 8 2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0 Sign The sign (S) of the analog value is always in bit number 15 "0" + "1" Manual, 04/2007, A5E01076949-01 15

Analog value representation 4.3 Output ranges Output value The following table shows the representation of the binary analog values and the corresponding decimal and hexadecimal representation of the units of the analog values. The table below shows the 11, 12, 13, and 15-bit resolutions + sign. Each analog value is entered left-aligned in the ACCU. The bits marked with "x" are set to "0". Table 4-2 Output values (SIMATIC S7 format) Resolution in bits Units Analog value Decimal Hexadecimal High byte Low byte 11+S 16 10H S 0 0 0 0 0 0 0 0 0 1 x x x x 12+S 8 8H S 0 0 0 0 0 0 0 0 0 0 1 x x x 13+S 4 4H S 0 0 0 0 0 0 0 0 0 0 0 1 x x 15 + sign 1 1H S 0 0 0 0 0 0 0 0 0 0 0 0 0 1 4.3 Output ranges Output ranges for current ± 20 ma Table 4-3 SIMATIC S7 format Output range ± 20 ma Output range ± 20 ma Decimal Units Hexadecimal 0 > 32511 > 7EFFH Overflow 23,5150 32511 7EFFH 20,0007 27649 6C01H 20,0000 27648 6C00H 14,9980 20736 5100H Nominal range - 14,9980-20736 AF00H - 20,0000-27648 9400H - 20,0007-27649 93FFH Underrange - 23,5160-32512 8100H < - 23,5160 < -32512 < 8100H Underflow Overshoot range Range 16 Manual, 04/2007, A5E01076949-01

Analog value representation 4.4 Effect on analog value representation Output ranges for current 4 to 20 ma Table 4-4 SIMATIC S7 format Output range 4 to 20 ma Output range Units 4 to 20 ma Decimal Hexadecimal 0 > 32511 > 7EFFH Overflow 22,8100 20,0005 32511 27649 7EFFH 6C01H Overshoot range 20,0000 4,0000 3,9995 0 27648 0-1 -6912 6C00H 0H FFFFH E500H Nominal range Underrange 0 < -6913 < E4FFH Underflow Range 4.4 Effect on analog value representation 4.4.1 Effect of the supply voltage and the operating state on analog output values The output values of the analog modules are dependent on the supply voltage for electronics and on the operating state of the PLC (CPU of the DP master). This is illustrated by the table below. Table 4-5 Relationship between the analog output values for the operating state of the PLC (CPU of the DP master) and the supply voltage L+. Operating state of the PLC (CPU of the DP master) POWER ON POWER ON POWER OFF - RUN STOP Supply voltage L+ on ET 200S (power module) L+ present Output value of the electronic module with analog outputs PLC values Until first value output After startup, a signal of 0 ma or 0 V is output. Dependent on the parameter "CPU/master STOP" L+ missing - L+ present Dependent on the parameter "CPU/master STOP" L+ missing - L+ present Dependent on the parameter "CPU/master STOP" L+ missing - Manual, 04/2007, A5E01076949-01 17

Analog value representation 4.4 Effect on analog value representation 4.4.2 Effect of the value range on the 2AO I ST analog output The way electronic modules respond to analog outputs depends on where the output values fall within the value range. This is illustrated by the table below. Table 4-6 Response of the analog modules, depending on where the analog output value falls within the range of values Output value falls in... Nominal range Over-/underrange Overflow Underflow Prior to parameter assignment, or incorrect parameter assignment* Output value in SIMATIC S5/S7 format Value from DP master Value from DP master 0-signal 0-signal 0-signal * With product version 1 of the 2AO I ST, the following applies If the configured substitute value is outside the nominal range, a diagnostic message for a parameter assignment error is registered and the SF LED lights up. In this status the output values transferred from the DP master are output at the analog output modules. 18 Manual, 04/2007, A5E01076949-01

Connecting 5 5.1 Connecting analog outputs Introduction This chapter describes the factors to consider when connecting the analog outputs. Cables for analog signals You should use shielded and twisted-pair cables for the analog signals. This reduces the effect of interference. You should ground the shield of the analog cables at both ends. If there are differences in potential between the cable ends, an equipotential bonding current that may interfere with the analog signals will flow across the shield. In this case, you should only ground the shield at one end of the cable. Analog output modules In the case of the analog output modules there is generally galvanic isolation Between logic and backplane bus. Between the load voltage and MANA. Manual, 04/2007, A5E01076949-01 19

Connecting 5.1 Connecting analog outputs 20 Manual, 04/2007, A5E01076949-01

Index 2 2AO I ST analog electronic module Block diagram, 8 Properties, 7 Technical data, 9 Terminal assignment, 7 A Analog output modules Error types, 14 Analog output modules in SIMATIC S7 format, 16 B Basic knowledge requirements, 3 C Cables for analog signals, 19 D Disposal, 3 L LED display, 13 M Measuring ranges with SIMATIC S7, 15 O Output ranges, 16 Output value, 16 R Recycling, 3 Response of the analog modules, 17 During operation, 17 When faults occur, 17 S Scope Manual, 3 Service & Support, 4 I Internet Service & Support, 4 T Technical Support, 4 Training center, 4 Manual, 04/2007, A5E01076949-01 21

Index 22 Manual, 04/2007, A5E01076949-01