TETRIS 1000. High Impedance Active Probe. Features:

Similar documents
TETRIS 1000 / High Impedance Active Probe Order-No: Features:

1.5 GHz Active Probe TAP1500 Datasheet

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Current Monitoring Kit

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

Current Monitoring Kit QUICK START GUIDE

User's Guide. True RMS Industrial Multimeter

Output Ripple and Noise Measurement Methods for Ericsson Power Modules

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Reading: HH Sections , (pgs , )

How To Sell A Talan

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

K817P/ K827PH/ K847PH. Optocoupler with Phototransistor Output. Vishay Semiconductors. Description. Applications. Features.

AMP CO Plus Insert for Cat. 6 A Applications

Achat 212 H-SUB passive subwoofer. user manual

AutoRanging Digital MultiMeter

Achat 110 M passive full-range speaker. user manual

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Digital input modules

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Model CS 64 Mini-DIN Cable and Adaptor

Agilent 4339B/4349B High Resistance Meters

Kit Watt Audio Amplifier

Features. Modulation Frequency (khz) VDD. PLL Clock Synthesizer with Spread Spectrum Circuitry GND

CELO5. User & Installation Manual.

Spin Semiconductor FV-1 Reverb IC PN: SPN1001. Delay Memory DSP CORE. ROM and Program Control PLL. XTAL Drvr XTAL. Spin.

4N25 Phototransistor Optocoupler General Purpose Type

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z

i410/i1010 AC/DC Current Clamp

TGF3015-SM. Applications. Product Features. Functional Block Diagram. General Description. Pin Configuration

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

Fluke 3000 FC Series Test Tools Technical Data

AN3353 Application note

NI USB-5681 RF Power Meter Specifications

Ultra640 SCSI Measured Data from Cables & Backplanes

Achat 208 HL / 208 HR passive mid-range speaker. user manual

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

TISP9110LDM Overvoltage Protector

Application Note TMA Series

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

PS25202 EPIC Ultra High Impedance ECG Sensor Advance Information

40 V, 200 ma NPN switching transistor

Optocoupler, Phototransistor Output, with Base Connection

DVT913 TV CHANNEL CONVERTER

Directory chapter 04

Comparison of Vector Network Analyzer and TDA Systems IConnect Generated S-Parameters

HSD High Speed Data interconnection

IFS SP-PoE Splitter User Manual

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PRODUCT SPECIFICATION

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Inductors in AC Circuits

TISP4600F3, TISP4700F3 OBSOLETE

T Substation Maintenance and Commissioning Test Equipment

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

Supertex inc. HV Channel High Voltage Amplifier Array HV256. Features. General Description. Applications. Typical Application Circuit

Technical Note Series

High Speed Infrared Emitting Diode, 870 nm, GaAlAs Double Hetero

Features. Applications. Transmitter. Receiver. General Description MINIATURE MODULE. QM MODULATION OPTIMAL RANGE 1000m

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Description. Dimensions. Features. precision works better

This document is available at FAL-ANT-1. GSM/DCS/GPS antenna (with Fakra-SMB connectors) Description. Version 1.

RFI/EMI TELEPHONE FILTERS

MAXIMUM LOAD CURRENT 1 A SN SERIES

Datasheet. PoE Adapters. Provides Earth Grounding and Surge Protection. Helps Protect Against ESD Events. Powers Ubiquiti PoE Devices

iva Cable & Antenna Analyzer

Fluke 3000 FC Series Test Tools Technical Data

VOLUME AND TONE CONTROL - PREAMPLIFIER K8084


Oscilloscope Probes and Probe Accessories

Inductive sensor NI10-M18-Y1X-H1141

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

Coupling/Decoupling Networks (CDN)

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

This document lists specifications for the NI PXIe-4139 (NI 4139) precision system sourcemeasure

UMEC International Corporation

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

MASW TB. GaAs SPST Switch, Absorptive, Single Supply, DC-4.0 GHz. Features. Pin Configuration 1,2,3,4. Description. Ordering Information

Four quadrant diode front end module for the Virgo Linear Alignment 3/ 30 mw, plus configuration

High Common-Mode Rejection. Differential Line Receiver SSM2141. Fax: 781/ FUNCTIONAL BLOCK DIAGRAM FEATURES. High Common-Mode Rejection

CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE

Instructions A Amp AC/DC Current Probe

I STAR COMPUTER CO., LTD

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams

TISP4500H3BJ Overvoltage Protector

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Transcription:

High Impedance Active Probe Features: High Input Impedance Interchangeable Spring Tips Contacts adjacent Pins in 2,54 mm Pitch Useable with any 50 Ω Measuring Instrument The TETRIS active probe is a manufacturer independent measurement system, which can be used with any oscilloscope having 50 Ω input. Its small size and useful accessories are designed to make any measuring task easy. System- dependency is known to be an issue in many work places and laboratories, not only concerning measurement instruments and accessories. With a standalone power supply and relying on 50 Ω input only, PMK probes are independent from the measuring instruments as such. The small housing and the distinctive T-shape of the TETRIS probe head make contacts in 2.54 mm pitches especially easy, as multiple TETRIS 's probes can contact adjacent pins simultaneously. Connections to smaller parts are achieved either by an IC contacting system or famous clamps also available at PMK and partly enclosed in the standard scope of delivery. The choice for an active probe instead of a low-z passive one is simple, because passive probes, with their relatively high input capacitance, load the signal source already at frequencies above 100 khz. The TETRIS active probe offers high input impedance into the GHz-range.

This datasheet supersedes all previously published material. Specifications that are not marked as quaranteed are published as general information to the user. The instrument should have warmed up for at least 20 minutes and the environmental conditions must not exceed the specified limits of the probe. Note that specifications are subject to change without notice. Electrical Specifications Attenuation Ratio 10:1 ± 2 % at DC Voltage Coefficient 0.00025 % / V at DC Input Voltage (max) 20 V Probe Bandwidth 1.0 GHz (-3 db) System Bandwidth (1) 600 MHz (-3 db) Input Dynamic Range ±8 V Maximum Input Voltage and Dynamic Range The TETRIS Active Probe is secured against static overvoltage. Applying voltages above the ones stated here may damage or the destroy the amplifier at the Probe Tip. 100 Input Voltage vs. Frequency TETRIS 1000 / 1500 / 1500 Voltage [V] AC peak Voltage [V] AC peak 10 Maximum Input Voltage Dynamic Measuring Range Make sure to comply with the max. Input Voltages stated here to avoid errors of linearity and damage to the probe. 1 1M 10M 100M Frequency [Hz] [Hz] 1G 10G (1) Connected to oscilloscope with an Input Impedance greater than 500 MHz 2

Typical Input I Impedance TETRIS 1000 1M Ersatzschaltbild Tastkopf 100k R1 C1 R2 C2 Z [Ohm] Z [Ohm] 10k 1k C1= 1,0 nf R1= 3 C2= 0,88 Note pf that R2= the 1 MΩInput Impedance of the Probe decreases as the Frequency of the Applied Signal increases. 1 1 10 100 1k 10k 100k 1M 10M 100M Frequency [Hz] 1G Electrical Characteristics Input Resistance (system) 1 MΩ (± 1 %) Input Capacitance (system) 0.9 pf Input Coupling of the Measuring Instrument 50 Ω AC / DC Mechanical Characteristics Weight (probe only) Cable Length 48 g 1.3 m 3

Environmental Specifications Altitude operating up to 2000 m non-operating up to 15000 m Temperature Range operating 0 C to +50 C non-operating -40 C to +71 C Maximum Relative Humidity operating 80% relative humidity for temperatures up to +31 C, decreasing linearly to 40 % at +50 C Accessories for TETRIS Active Probes Tetris Active Probes support a vast number of accessories. From different Tips & Pins over Leads and Adapters to popular Clips you might know from other applications. Most of them are found in the standard scope of delivery marked (x) in the table below. Differing in quantity from the sets being sold seperately, (x) states the number of individual accessories enclosed. See illustrations on the following page for clarification or ask our sales department for detailed information on the part in question. Probe Tips Set 5 Spring Tips (1) 890-800-001 Set 5 Solid Tips (1) 890-800-000 L-In Adapter (1) 890-50-800 Ground Connectors Ground Blade (1) 018-291-103 Z-Ground (1) 890-400-800 10 self-adhesive Cu-Pads (2) 890-100-150 Set 10 PCB Adapter (1) 890-700-108 Set 25 PCB Adapter 890-700-258 Ground Leaf (1) 890-291-105 Ground Leads Ground Lead 6 cm (1) 890-400-801 Ground Lead 12 cm (1) 890-400-802 Ground Lead 90 5 cm (1) 890-400-803 Ground Lead 90 10 cm (1) 890-400-804 Sprung Hooks Pico Hook black (1) P25-0 Pico Hook red (1) P25-2 Micro Clips 1 Pair QFP IC-Clips short 890-502-000 1 Pair QFP IC-Clips long 890-502-130 Adapters Y-Lead Adapter (1) to 0.8 mm sockets 890-720-800 Y-Lead Adapter to open Leads 3 cm 890-720-813 Y-Lead Adapter to open Leads 6 cm 890-720-816 Miscellaneous Marker Bands 4x4 Colors (1) 890-020-916 Tetris Accessory Set 899-180-000 Power Supply PS-01 (1) 889-000-001 4

TETRIS 1000 Accessories for TETRIS Active Probes 890-700-108 Set 10 PCB Adapter 890-700-258 Set 25 PCB Adapter 890-400-800 Z-Ground 018-291-103 Ground Blade 890-291-105 Ground Leaf 890-100-150 10 self-adhesive Cu-Pads (2x2 cm) 890-020-916 Marker Bands 4x4 Colors 890-800-001 Set 5 Spring Tips 890-800-000 Set 5 Solid Tips 890-500-800 L-In Adapter 890-502-130 QFP IC-Clips long to 0.5 mm pitch (1 pair yellow/green) 890-400-801 Ground Lead 6 cm 890-720-800 Y-Lead Adapter to 0.8 mm Sockets 890-400-802 Ground Lead 12 cm 890-502-000 QFP IC-Clips short to 0.5 mm pitch (1 pair yellow/green) 890-720-816 Y-Lead Adapter to open Leads 6 cm 890-400-803 Ground Lead 90 5 cm P25-2 /-0 Pico Hook red / black 890-720-813 Y-Lead Adapter to open Leads 3 cm 890-400-804 Ground Lead 90 10 cm

WEEE/ RoHS Directives PMK electronic products are classified within the WEEE/ RoHS* category list as monitoring and control equipment (category 9). Category 9 products are exempt from the restrictions under the scope of the RoHS directive. Your help and efforts are required to protect and keep clean our environment. Therefore return any electronic product at the end of its life either to Service Department of PMK Mess- und Kommunikationstechnik GmbH or take care of separate WEEE collection and professional WEEE treatment yourself. Do not dispose as unsorted municipal waste. * EC Directives: WEEE Directive 2002/96/EC Waste Electrical and Electronic Equipment RoHS Directive 2002/95/EC Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment Safety Information To avoid personal injury and to prevent fire or damage to this product or products connected to it, review and comply with the safety informations stated in the manual before using this product. Be aware that if you use this probe assembly in a manner not specified the protection this product provides may be impaired. Only qualified personnel should use this probe assembly. Manufacturer PMK Mess- und Kommunikationstechnik GmbH Königsteiner Str. 98 65812 Bad Soden, Germany Internet: www.pmk.de Tel: +49 (0) 6196 5927-930 E-Mail: sales@pmk.de Fax: +49 (0) 6196 5927-939 Revision C - March 2014 6