UltraLITE. Centralized Emergency Lighting Inverters MODEL ELU



Similar documents
LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Uninterruptible Power Supply

Eaton 93PM UPS Where aesthetics meet intelligence.

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

MAJORSINE Power Inverter

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

LAP ENERGIA PARA DATACENTERS

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

PowerGem Pro Uninterruptible Power Supply

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Model #: SMART2200CRMXL

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

TOSHIBA G /100/160/225 kva

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Specification Requirements DBL 700MX and 1000MX Series UPS

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Eaton 93PM UPS Efficient. Scalable. Innovative.

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Galaxy VM. Three-phase power protection. schneider-electric.com

Internet Office 500VA Tower Standby 120V UPS with USB port

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Smart-UPS On-Line 230 V

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

Power Quality. Uninterruptible Power Supply

SG Series UPS kva three phase 400 Vac

Back-UPS Pro 1300/1500 Installation and Operation

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Application Note: Emergency Battery Backup System (EBBS) Solutions for the XIM Platform

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

SECTION DETECTION AND ALARM

Liebert PPC Second Generation Power Distribution Cabinet

United Security Products Automatic Dialers are a NEW BREED of Security

BC Pro UPS System Standby UPS System

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

SWITCHGEAR. EGP Switchgear

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

Tough Decision: On-Line or Line-Interactive UPS?

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Square D Powerlink G3 Lighting Control Systems

High Bay Occupancy Sensor Selection Guide

User Manual 1K/2K/3K Online UPS

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Technical Data. back-up time in minutes 100% load % load

Online UPS. PowerWalker VFI 1000R/1U

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

Installation and Operation Back-UPS 1250, 1300, 1500

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

Transfer Equipment Controls

UNINTERRUPTIBLE POWER SUPPLY (UPS)

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

A project to optimise quality and energy efficiency must include metering

Assembled in Florida, USA.

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

Fire Pump Controllers Remote Alarm Panels

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

SECTION STATIC UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Thyristor-controlled power supplies and battery chargers

IBM 11000VA LCD 5U Rack Uninterruptible Power Supply IBM System x at-a-glance guide

Eaton 93PM UPS Efficient. Scalable. Innovative.

Phase Modular Finally the benefits of Modular ups are for all

Internet Office UPS System Standby UPS for PCs, workstations and more

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

R5000 Uninterruptible Power System (UPS) Overview

Intelligent Power Distribution in the Data Center

Transcription:

1.5 kw 14 kw SINGLE PHASE UltraLITE MODEL ELU Centralized Emergency Lighting Inverters True no-break system, with regulated output and transient voltage protection for LED lighting, electronic ballasts, as well as all other existing and future lighting applications. Meets NFPA 101, 111, NEC, IBC and local codes. Applications: Schools / Universities / Dormitories Security / Public Address Systems Arenas / Stadiums Subways / Mass Transit Parking Structures / Garages Hospitals / Clinics Office Buildings Shopping Malls Airport Terminals Casinos / Resorts Hotels / Motels Apartment Buildings Correctional Facilities UL 924 Listed / C-UL Listed to CSA C22.2 No. 141-10 UL 1778 Listed / C-UL Listed to CSA C22.2 No. 107.1-01

EMERGENCY LIGHTING REQUIREMENTS The UltraLITE, Model ELU = Life Safety Apart from the existing emergency lighting codes, many U.S. cities and states have adopted legislation that requires buildings with 5 or more units of occupancy to have a centralized emergency lighting system, where single-point operation controls a facility s many smaller circuits, and all testing and record-keeping of the emergency power equipment is performed from one location. Meeting stringent requirements in construction and performance, Controlled Power Company s self-diagnostic, self-testing, UltraLITE centralized emergency lighting inverters are UL 924 listed as Emergency Lighting Equipment and Auxiliary Power Supplies, as well as NFPA compliant as Life Safety Equipment. The UltraLITE offers more security and versatility to meet illumination requirements, and is the perfect complement for all life safety and lighting applications the universal solution. Our inverter technology effectively maintains critical equipment with extended brownout protection, tight voltage regulation, and power conditioning. Tight voltage regulation assures that facility egress lumens are maintained 100% at emergency lighting fixtures, in all modes of operation, and also extends ballast, LED driver, and lamp life. Normally Off Emergency Lights Zone Sensing Normal Lighting Panel Major Advantages Of The UltraLITE, Model ELU Design Flexibility Using existing fixtures for emergency lighting and egress assures compliance with minimum illumination code requirements. Extensive combinations of input and output voltages, timed off bus with remote command on control, automatic battery testing, and control device override options make the UltraLITE one of the most versatile and dependable lighting inverter systems in the market. Single Point Operation / Maintenance One central inverter controls many smaller circuits. Cost-effective, single-point operation provides a common battery pack, and enables all maintenance to be performed and records to be logged from a single location. Additional benefits include: Egress lighting integrity test. Hot-swappable battery replacement. Standard internal bypass. Maintenance-free, standard 15-year pro-rated batteries. Premium Power And Voltage Regulation Maintains proper operating voltage for HID and high-pressure sodium lighting, as well as electronic ballast and LED lighting, resulting in: Voltage sag and surge protection. Longer wire runs without upsizing the wire. Regulated voltage source minimizes voltage drop. Less-frequent replacement of ballast, LED drivers, and lamps. Facility egress lumens are maintained 100% (will not diminish) over the full 90 minutes of emergency power. Generator-Compatible The UltraLITE is listed UL924 Auxiliary Power Supplies, and is suitable to provide uninterrupted back-up power until a generator starts. Even with an extremely distorted input waveform, the output of the UltraLITE delivers a clean sinewave, with no more than 3% THD, without switching to batteries. This feature also extends ballast, LED driver, and lamp life. Reduced Utility Expense Energy conservation continues to be a prevalent issue. The UltraLITE provides several energy-saving solutions without compromising life safety requirements. Use of our optional ZoneSaver-2, emergency lighting control unit : Allows for local control of emergency lighting fixtures to reduce / eliminate unnecessary night-light circuits and always on lighting loads. Allows for automatic bypassing of the local control device during NFPA-mandated test periods. Provides multiple, independent zone sensing abilities to reduce / eliminate unnecessary multiple-floor and multiple building-wing illumination. (Refer to the illustration to the left.) ZoneSaver-2 All of these advantages result in the best reliability and net performance of your lighting system! UltraLITE 2 April 2015. Controlled Power Company. Intellistat TS, ZoneSaver-2 and NetMinder are trademarks of Controlled Power Company.

SYSTEM DESCRIPTION & SPECIFICATIONS Controlled Power Company engineers and manufactures the industry s highest quality centralized emergency lighting inverters, capitalizing on 4 decades of expertise. We have an enviable reputation for quality, which is reflected in the design, workmanship, and performance of our products. Providing a seamless transfer to back-up power for your emergency lighting system, the UltraLITE is compatible with all fixtures including LED, HID, metal halide, high-pressure sodium, quartz / mercury vapor, halogen, fluorescent, and incandescent lighting applications. The voltage regulation and performance characteristics of the UltraLITE offer a significant advantage over competing products. Features & Benefits Uninterrupted, regulated, continuous sinewave output for use with normally on lighting fixtures and exit lamps. Standby output for use with normally off emergency lighting fixtures. Pulse width modulation and IGBT technology provide tight output voltage regulation. Delivers highly-filtered, regulated, and spike-free power to emergency lighting fixtures and Life Safety devices. True, online double-conversion topology provides conditioned, regulated power and 100% reliability to emergency lighting loads. Auxiliary input command. High-speed static bypass. System approved for 42k AIC rated source. Variable-range logic provides added security during deep brownout conditions, without battery consumption thus assuring that the batteries will be at full capacity for a power outage. Field-modifiable distribution. Short-circuit protected. NEMA 1 enclosure. Generator-compatible. 4-stage, temperature compensating smart charge. Optional control device override (wall switch, occupancy sensor, dimmer, etc). Optional zone sensing. Optional remote status panel and automatic phone dialer. Optional network connectivity. Safety UL 924 listed Emergency Lighting Equipment UL 924 listed Auxiliary Lighting and Power Equipment UL 1778 listed Uninterruptible Power Supplies C-UL listed to CSA C22.2 No. 141-10 Emergency Lighting Equipment C-UL listed to CSA standard C22.2 No. 107.1-01 General Use Power Supplies CCMC Approval # 13428-R (Canadian Construction Materials Centre) NFPA 101, NFPA 111, NEC, and local codes Product Specifications Input Operating Voltage Range: +12%, -30% typical, load-dependent without battery usage Input Frequency: 60 Hz, ± 2.5% Input Current Harmonic Distortion: <5% THD Input Power Factor Correction: >.99 PF Output Sine Wave Voltage: Typical 3% output THD with linear load Output Regulation: Typically better than ± 1.5% Output Circuit Breaker Pole Spaces Available: Without Trip Indicator Alarm / Light: 20 With Trip Indicator Alarm / Light: 10 Standard Unit Operating Temperature: UL and C-UL 1 listed as 0 C to 40 C. Total System MTBF: Approx. 100,000 hours Audible Noise: < 50 db Noise Attenuation: 2 Common Mode: 120 db Transverse Mode: 70 db 1 C-UL listed to CSA C22.2 No. 141-10 Emergency Lighting Equipment at 20 C to 40 C. 2 Models supplied with isolation transformer. Standards ANSI / IEEE C62.41 Category B3 NFPA 101 NFPA 111 Stored Electrical Energy Emergency and Standby Power Systems. Meets SEPSS / ECE / Level 1 and Level 2 criteria for types O, U, A, B, and 10; and Classes up to and including Class 1.5 NFPA 70 National Electric Code FCC Class A limits, 47 C.F.R. Part 15, Subparts A, B IEC 555 3

STANDARD COMMUNICATIONS & DIAGNOSTICS Display Monitor & Diagnostics The UltraLITE s full-featured monitoring system includes: Self-test diagnostics. Automatic battery test. Audible alarms. Protected ON / OFF switch. Push-to-test. The UltraLITE also has a full complement of indicators: Percent load. High / low / normal input voltage. On battery. Percent of battery. Check battery. Bypass status. Alarm status. Communications & Diagnostics Integral status and alarm panel. Remote communications via alarm signals or RS232. Batteries Integral 90 minute, maintenance-free batteries. Automatic, pre-programmed battery testing, including self-diagnostics. Small footprint and self-contained batteries maximize floor space. Rapid recharge, per UL 924 requirements. Simplified Maintenance For Centralized Lighting Single-point operation. One central inverter controls many lighting circuits. Centralized system significantly reduces man-hours required for monthly testing. All testing and record-keeping are performed from one location. Secure bypass switch allows for uninterrupted bypass of the inverter to utility power for any maintenance situation. Eliminates vandalism potential that exists with wall-pack emergency lighting systems. Besides its cooling fans, the UltraLITE has no mechanical or moving parts. Front-access to standard input breaker, bypass switch, and optional output distribution circuit breakers. Low cost of ownership resulting from: high inverter efficiency, lower maintenance, and optional control device override. 4

OPTIONAL COMMUNICATIONS & DIAGNOSTICS Advanced Digital Monitoring The Intellistat TS TM (Available for 4.2 kw - 14 kw, all models and 3 kw - 3.5 kw, excluding 208/120V and 240/120V models) The user-friendly Intellistat TS monitor provides quick, full-access to all of the inverter s features, allows all programming to be done directly from the touchscreen display, and provides complete system diagnostics and testing. A color, TFT, high resolution touch-screen display indicates all the electrical parameters, as well as the functional status of the inverter. The touch-screen display allows the entry of the date / time values, system setpoints, and password information into the monitor, without the need for an external computer and cable. The Intellistat TS s features include: LCD display of all electrical parameters. NFPA-compliant automatic battery testing / logging. User-programmable automatic system testing. System alarm annunciation. Audible alarm with alarm silence. Alarm status display. Programmable alarm set-points. Date and time display. Auto-logging of test results and abnormal events. Multi-layer password protection. Programmable local interfaces. Logs up to 50 events. Non-volatile clock and memory. Remote monitoring capabilities. Optional reporting of test results via fax / e-mail / voice / webpage. Optional status notification via e-mail / cell-phone. Monitored Parameters The Intellistat TS monitors the following parameters and inverter status indicators: Input voltage. Output percent load. Output voltage. Output frequency. Output current. Battery voltage. Output VA. Battery charger current Output watts. Percent battery time remaining. Output power factor. Alarms & Status The Intellistat TS announces many alarms, including the following: High / low input voltage. Low battery warning. High / low output voltage. Low battery shutdown. High output VA (overload). Battery test in progress. *Low output VA. Auto battery test failed / passed. High / low output frequency. Off bus status. High / low battery voltage. DC charger fail / DC open. High battery charger current. Output circuit breaker open. System normal.. REPO shutdown. General alarm. System in static bypass. System on battery. System in manual bypass. * User-programmable limit referenced during automatic battery testing, to verify integrity of egress lighting. The color touchscreen display on the Intellistat TS provides all electrical parameters, inverter status, programmable inverter and battery testing, and data-logging. Optional NetMinder communications allow for remote monitoring and reporting. For more details, see the Optional NetMinder Communications description on Page 7. Egress Lighting Integrity Test To satisfy NFPA-mandated periodic and annual requirements, the Intellistat TS automatically initiates the testing of all life safety circuits, regardless of egress lighting design ( always on or normally off ). The Intellistat TS then compares power consumption during the test period with user-defined load capacity, analyzes the data, and advises if service is required. During these NFPA-mandated tests, a test activated contact may be used to activate one or more remotely installed ZoneSaver-2 emergency lighting control units. When activated, the ZoneSaver-2 will feed emergency power to egress lighting that is normally off, or dimmed / turned off via a local control device. This option allows for automatic testing of the locally controlled life safety circuit and the ZoneSaver-2 control unit. Automatic System Tests The Intellistat TS automatically performs a userdefined (date and time) 5-minute system test every 30 or 90 days. It also performs user-defined (date and time) 30-, 60-, or 90-minute, or 2- or 4-hour annual system tests. For all of these tests, the Intellistat TS logs the test results with date and time, as well as a pass or fail indication. Manual System Tests The Intellistat TS also allows the user to manually invoke a user-defined system test for 30-, 60-, or 90- minutes, as well as 2- or 4-hours. A 1-minute or 5-minute manual test is also available for spot inspections. 5

DESIGN FLEXIBILITIES & PROVEN SOLUTIONS The UltraLITE offers design flexibilities which are not provided with competing lighting inverters: Multi-Voltage Capabilities (Figure 1) The UltraLITE is a power factor corrected, uninterruptible, double-conversion system, with a static transfer switch for maximum reliability. An internal make-before-break bypass switch maintains the proper output voltage in bypass, even dual output voltage configurations. The UltraLITE accepts and distributes the industry s broadest range of voltages, from 120 VAC 600 VAC. UL 924 Auxiliary Lighting and Power Equipment (Figure 2) In addition to being UL 924 listed with 90 minutes as Emergency Lighting Equipment, the UltraLITE is UL 924 listed with other battery runtimes as Auxiliary Lighting and Power Equipment. When provided with 10-15 minutes of battery, the UltraLITE is the perfect complement to generator-based emergency lighting systems. The UltraLITE provides uninterruptible, regulated power to critical lighting systems and other life safety related equipment. Additionally, for uncompromised personal safety, critical "always on" lights remain illuminated, and the generator synchronization delay is eliminated. Remote Input Command (Figure 3) Allows the monitoring of multiple locations and events within the emergency lighting system, and may be activated by a signal from any specified monitoring point. If an unacceptable condition exists at one or more of the locations being monitored, the open contact energizes the Normally Off bus, thus illuminating the Normally Off emergency lights. Likewise, when normal conditions are restored, the Normally Off bus is de-energized, and the emergency lights return to their Normally Off state. (Figure 1) (Figure 2) (Figure 3) Egress Light Circuit (Always ON) Egress Light Circuit (*Normally OFF) *Energized during loss of input power or alarms 1-4. Local Control Device Override (Figure 4) The UltraLITE allows for user control of emergency egress lighting. This includes (but is not limited to) occupancy sensors, wall switches, and dimmer switches. Not only is this approach more reliable, it also saves money because it reduces costly always on circuits. (Figure 4) - Zone Sensing (Figure 5) The most cost-effective emergency lighting applications allow for independent activation of Normally Off fixtures in multi-floor or multi-use facilities. The UltraLITE uses ZoneSaver-2 TM to monitor normal lighting circuit panels for each floor / zone. Loss of power at the normal lighting circuit panel, or activation by the inverter s periodic or annual test active contact, energizes the emergency lighting for that floor / zone only. (Figure 5) - 6

INVERTER OPTIONS & CABINET CONFIGURATIONS The UltraLITE offers a variety of special options: Normally Off Bus Provides standby power to normally off emergency lamps, at the same or different voltage than normally on emergency lamps. When utility power is lost or voltage is inadequate, emergency power is supplied to normally off lights, providing a safe means of egress. Timed Normally Off Bus Functions the same as the Normally Off Bus (above), but differs in that the Transfer ON and Return OFF times for the bus are programmable. This programmable feature is especially useful to prevent nuisance activation of emergency lighting during short-term power disturbances. Additionally, the return delay provides sufficient time for standard HID lighting recovery, factory-set at 15 minutes. Automatic Phone Dialer Plugs into the communications port of the inverter, and can be programmed to notify personnel of alarm conditions. This small device can dial up to four (4) phone numbers (land, cell, pager); and records and delivers a custom voice message.. Output Distribution Circuit Breakers Meeting the need for flexible power distribution, circuit breakers can be added, subtracted, or moved without any complex mounting techniques. Output circuit breakers can be configured to supply power to different lighting loads at different voltages. Front-access to the standard input breaker and the optional output distribution circuit breakers is through a lockable drop-down panel door. Optional NetMinder Communications The NetMinder s series of adapters integrate the UltraLITE into a BACnet/IP or BACnet MS/TP, Ethernet TCP/IP, MODBUS TCP, or MODBUS RS485 network with a specific IP address for Ethernet connected systems. The NetMinder provides remote monitoring of the inverter status, battery test pass/fail results, alarm conditions, and electrical measurements via a web browser, without the need for any external software. Remote notification of alarms and status are available via SNMP, e-mail, and network broadcast messaging. Temperature and humidity sensing interface are also available. Front Access Design The UltraLITE has a compact, space-saving footprint, and front access to accelerate installation, testing, and maintenance procedures. Standard, 15-year pro-rated batteries are either self-contained or in a user-friendly battery cabinet with easy-access lift-off doors. The footprint illustrations below assume unity power factor and 90 minutes runtime. Consult factory for additional front access cabinet configurations using alternative runtimes. OUTPUT RATING INVERTER (A) BATTERY (B) 7.5kW - 10kW 29 W x 24 D 36 W x 24 D 12.5kW - 14kW 36 W x 27 D 1.5kW - 3.5kW 4.2kW - 7kW 7.5kW - 14kW 72 80 80 36 24 36 24 (A) W (B) W D 7

PRODUCT SELECTION GUIDE MODEL NUMBER GUIDE PRODUCT INPUT OUTPUT FREQ kva / kw MONITOR BATTERY DISTRIBUTION OFF BUSS ELU - Lighting Inverter A=120 J=277 L=208/120 G=240/120 V=347 D=480 E=600 A=120 J=277 Y=277/120 L=208/120 G=240/120 V=347/120 NOTE: Consult factory for output distribution options. X=60Hz Lighting Inverters 1.5 kw 2.2 kw 3 kw 3.5 kw 4.2 kw 5 kw 6 kw 7 kw 7.5 kw 8.5 kw 10 kw 12.5 kw 13.5 kw 14 kw 0=Standard 1=Intellistat TS S=90m N=None or UPS Battery Option 0=None 1=Yes 0=None 1=Off Bus T=Timed Off Bus ELU MODEL NUMBERS UL 924 MODELS kva / kw WEIGHTS (LBS) 1 WEIGHTS (LBS) 1 WEIGHTS (LBS) 1 WEIGHTS (LBS) 1 FULL LOAD STANDBY MODE INPUT - OUTPUT VAC INPUT - OUTPUT VAC INPUT & OUTPUT VAC INPUT - OUTPUT VAC BTU S / HOUR 2 BTU S / HOUR 3 60 Hz 60 Hz 60 Hz 60 Hz 120-120 277-277 208/120V 480-240/120V 277-277/120 347-347/120 240/120V 600-240/120V 480-277 480-277/120 600-347/120 ELU-**X-1.5kW-1S ** 1.5 898 1081 na na 511 128 ELU-**X-2.2kW-1S ** 2.2 898 1081 na na 750 188 ELU-**X-3kW-1S ** 3 1073 1256 1073 na 1023 256 ELU-**X-3.5kW-1S ** 3.5 1073 1256 1073 na 1194 298 ELU-**X-4.2kW-1S ** 4.2 1459 1645 1459 1645 2005 358 ELU-**X-5kW-1S ** 5 1548 1734 1548 1734 2387 426 ELU-**X-6kW-1S ** 6 na 2254 2004 2254 2864 512 ELU-**X-7kW-1S ** 7 na 2254 2004 2254 3342 597 ELU-**X-7.5kW-1S ** 7.5 na 2808 2630 2808 3581 639 ELU-**X-8.5kW-1S ** 8.5 na 2898 2648 2898 4058 725 ELU-**X-10kW-1S ** 10 na 3298 3048 3298 4774 853 ELU-**X-12.5kW-1S** 12.5 na 4124 3684 4124 5967 1065 ELU-**X-13.5kW-1S** 13.5 na 4134 3694 4134 6445 1151 ELU-**X-14kW-1S** 14 na 4576 4136 4576 6684 1194 VOLTAGE CONFIGURATIONS **X = Input - Output VAC, 60 Hz AA = 120-120 JJ = 277-277 JY = 277-277/120 LL = 208/120-208/120 GG = 240/120-240/120 VV = 347-347/120 DG = 480-240/120 DJ = 480-277 DY = 480-277/120 EG = 600-240/120 EV = 600-347/120 Output KVA / kw 1.5 kw - 5 kw 1.5 kw - 14 kw 3 kw - 14 kw 4.2 kw - 14 kw Notes: Each model includes 90 minutes back-up time, per UL 924 Emergency Lighting Equipment. Battery runtimes other than 90 minutes are available under UL 924 Auxiliary Lighting and Power Equipment consult factory. Models are also listed UL 1778 and C-UL Uninterruptible Power Supplies. Consult factory for specific applications and runtimes. 1 Cabinet weights include the weight of batteries for standard 90 minutes runtime. Battery weights vary according to desired runtimes consult factory for runtimes other than 90 minutes. 2 BTU s are typical at rated load. Consult factory for maximum BTU s / hour ratings on specific models. 3 Standby BTU s represent emergency lighting loads that are normally off or turned off via a local control device, used together with a UL 924 listed bypass relay. Stated BTU s for 120V, 208/120V, and 240/120V models. Consult factory for standby BTU s on other models. Represented by: 1955 Stephenson Hwy. Troy MI 48083 www.controlledpwr.com email: info@controlledpwr.com Phone: (248) 528-3700 Fax: (248) 528-0411 Call Toll Free: (800) 521-4792 All information and data within this brochure are subject to change without notice. Copyright April 2015. Controlled Power Company. ELU-009-0415